Search PubMed⌕ Search

Biomedical subjects

H Hashiba

Publications and source records attributed to H Hashiba.

41 records · Page 3Linked to original sources

[Clinical studies on PC-904 in biliary tract diseases (author's transl)].

The clinical effects of PC-904, a new semisynthetic penicillin, were studied in patients with biliary tract diseases, and the results were as follows: 1) PC-904 showed an average peak serum level of 40.7 +/- 11.6 microgram/ml 2 hours after an intravenous drip infusion of 1 g of the agent. The biliary level showed a peak value of 126.5 +/- 85.4 microgram/ml 2 hours to 3 hours after the infusion. 2) Isolated organisms from bile before the treatment were E. coli, Klebsiella, Proteus, Pseudomonas, Enterococcus and Bacteroides. MIC of PC-904 on 18 strains of isolated organisms was almost 6.25 microgram/ml or less. All isolated organisms except one strain of Klebsiella oxytoca disappeared after the treatment. 3) Six patients with cholelithiasis were medicated with PC-904 to prevent post-operative infections. The clinical effects were good in 4, poor in 1 and unknown in 1 case. 4) As to side effects no adverse reactions and allergic reactions were noted. Also no significant abnormalities of laboratory findings were observed.

Ampicillin↗

A method of tomographic imaging using a multiple pinhole-coded aperture.

High energy collimators in use today are limited with respect to resolution and efficiency. The multiple pinhole coded aperture (hereafter abbreviated as MPCA) is a method being considered to improve the above. In our study we conducted basic experiments with an MPCA using an Anger-type gamma-camera. Using this method, we were able to perform radioisotope imaging and radioisotope tomographic effect. We have studied the resolution, detection efficiency, and tomographic effects of the MPCA. We found that, in the MPCA, detection efficiency is proportional to the number of pinholes and resolution is dependent upon the pinhole diameter. This tomographic effect is of the same principle as the stretching-type tomography, images on both side of the desired image appearing as noise images, affecting the depth resolution. Using an MPCA with a pinhole diameter of 3 mm and 3 pinholes positioned in an equilateral triangular pattern measuring 7.8 cm on each side, we attained a depth resolution of 3 cm. Because the MPCA method involves complicated image processing, the resulting image contains a factor of 2n-2 (where n is the number of pinhole) of noise, affecting the depth resolution.

Radionuclide Imaging↗