Search PubMed⌕ Search

Biomedical subjects

H Harasaki

Publications and source records attributed to H Harasaki.

At least 37 records · Page 2Linked to original sources

Compliance effects on small diameter polyurethane graft patency.

Microporous compliance matched and noncompliant grafts were compared in a dog carotid artery interposition model. We fabricated 4 mm diameter sponge type polyurethane (Biomer) tubes 5 cm in length with a 0.5 mm wall thickness. The luminal surface was covered with a 50 microns coating of cross-linked gelatin. Compliance was measured in vitro and in vivo by volume and vessel diameter changes. Over a mean arterial pressure range of 55-155 mm Hg, the diameter changes of grafts and stump arteries were measured in situ using an ultrasonic Hokanson device. Compliance matched grafts were found to have the same in vitro compliance values as the natural canine carotid at a mean arterial pressure of 100 mm Hg. Compliance matched and noncompliant grafts had values of 10.3 +/- 1.3 and 0.9 +/- 0.1 x 10(-2) mm Hg, respectively. End to end arterial anastomoses were constructed between the graft and the host arteries. The use of synthetic grafts with matched compliance to the adjacent natural vessels has been advocated as the ideal solution to circumvent the problems of graft failure. These studies indicate that compliance values for compliance matched grafts decreased immediately after implantation (from 10.3 to 6.5 x 10(-2) %/mm Hg) and within 6 weeks decreased to 3.6 x 10(-2) %/mm Hg. The compliance values for noncompliant grafts remained constant throughout the test period. At autopsy all grafts showed a tightly adhered tissue capsule. The thickness of the anastomotic hyperplasia at the distal sites of compliance matched grafts was significantly different (P < .05) than that of the adjacent artery. The patency for compliant and noncompliant grafts was 64% and 50%, respectively. Evidence for polyurethane graft degradation was obtained by Fourier transform infrared spectroscopy and gel permeation chromatography analysis of patent explants. Compliance mismatch alone does not contribute to graft failure, however, material degradation, suture technique and/or capsule formation can play a contributory role although these were not tested directly.

Animals↗

Quantification of the edge effect in calcified bioprosthetic tissues.

In bioprosthetic tissue samples that had been implanted in the subcutaneous space of rats, and recurring pattern of calcification was observed. In this pattern, which we call the edge effect, the interior of the tissue is calcified and is surrounded and separated from the subcutaneous fluid by a zone that is free from calcification. The edge effect has been qualitatively described in the literature for subcutaneous implants and for valve leaflets, and it may be related to the mechanism of calcification for these materials. The thickness of the calcification free outer layer was quantified for glutaraldehyde treated bovine pericardium, glycerol treated bovine pericardium, glutaraldehyde treated human dura mater, and glycerol treated human dura mater. The edge effect values were found to be unique and consistent for each material type, and they were inversely related to the shrinkage temperatures and the calcium contents of the materials. It was determined that the chemical treatment was more important than the tissue type in determining the edge effect value.

Abdomen↗

Effects of stent design and serum cholesterol level on the restenosis rate in atherosclerotic rabbits.

We investigated the effect of serum cholesterol level and stent design on the restenosis rate within the stent after balloon angioplasty and stent implantation using atherosclerotic rabbits. Two types of nickel/titanium stents with gaps (open stent) and without gaps (closed stent) between the wire coils were implanted into the aorta of the rabbits 10 weeks after atherosclerosis had been induced using a standard high cholesterol diet and balloon abrasion. Each rabbit had an open stent and a closed stent implanted into the infrarenal abdominal aorta. Between these two stents a control segment of the aorta was treated with angioplasty alone. The animals were divided into two groups according to the diet protocol as follows: in group I (n = 9) a high cholesterol diet was stopped after stent implantation; in group II (n = 10) a high cholesterol diet was maintained after stent implantation. Digital subtraction angiograms were obtained every 4 weeks for up to 24 weeks and the narrowest diameter of the arterial segments within each stent and in the segment between stents was measured. The diameter narrowing within the closed stent was greater in the high cholesterol group compared with the low cholesterol group: 12 weeks (2.57 +/- 0.09 mm in group I vs 2.14 +/- 0.15 mm in group II, mean +/- S.E., p < 0.05); 16 weeks (2.55 +/- 0.09 mm vs 2.14 +/- 0.12 mm, p < 0.05); 20 weeks (2.59 +/- 0.06 mm vs 1.98 +/- 0.12 mm, p < 0.01); and 24 weeks (2.45 +/- 0.11 mm vs 2.01 +/- 0.11 mm, p < 0.05). No significant differences in the narrowest diameter of the arterial segments were observed between high and low cholesterol groups in the angioplasty alone areas or within the open stents. There was a significant difference in the narrowest diameter between stents with versus those without gaps (at 12, 16, and 20 weeks poststenting in group I and at 4, 8, 12, 16, 20, and 24 weeks in group II). Thus the stent with the least metal is correlated with less stenosis and intimal hyperplasia. From these data we conclude that both stent design and serum cholesterol are important factors for restenosis after stent implantation.

Angioplasty, Balloon, Coronary↗

Renal effects of multiple infusion of pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP) solution in dogs.

Pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP), which is made from out-dated human red blood cells by two major chemical modifications, namely pyridoxalation and conjugation with polyoxyethylene (POE), is currently under development as a physiological oxygen carrier. This study assessed the effects of PHP-88 solution, which contains 8% (wt/vol) each of hemoglobin (Hb) and maltose, on renal function when it was infused 3 times every other day into the intact circulation of 8 dogs (5 dogs for the PHP group and 3 for the control group; 20 ml/kg for the first infusion, and 10 ml/kg each for the second and third infusions, at the rate of 2.5 ml/h/kg). Serial determinations of glomerular filtration rate (GFR) and renal plasma flow (RPF) were carried out pre- and postinfusion for up to 3 months along with measurements of blood and urine analyses, urine output rate, fractional excretion of sodium (FES), and free water clearance (CH2O). The results showed that plasma colloid osmotic pressure (COP) elevated an average of 3.3 mm Hg (p = 0.0085), and GFR and RPF tended to increase by 13% (NS) and 38% (NS), respectively, immediately after the third infusion with PHP solution. Urine output rate increased during and after the infusion, and FES and CH2O also increased for 24 h after the infusion in both groups. Blood urea nitrogen, serum creatinine, and serum Na+ concentrations were not affected greatly by the infusions, but hematocrit was decreased by 8% in the PHP group, indicating approximately a 42% expansion of plasma volume. These changes were observed to return to their preinfusion levels by 1 week postinfusion. Renal histology of the PHP group obtained at 2 weeks postinfusion revealed vacuole formation in the proximal tubules which was not associated with any pathologic changes indicative of cell death or regeneration. In 4 out of 5 dogs at 3 months postinfusion (necropsy), the vacuoles were not present. Though urinary N-acetyl-beta-glucosaminidase (NAG) activity had significantly increased after infusion, it returned to the preinfusion level by 1 month postinfusion. No detrimental effect of vacuoles on the assessed renal tubular functions was confirmed in the present study. The results demonstrated that multiple infusions of PHP solutions were well tolerated in normal dogs, and the observed effects were conceived predominantly attributable to the physiological response of the kidneys to an oncotic load into the circulation, which produced plasma volume expansion.

Animals↗

Chronic in vivo function of a new ventricular assist device: the extracorporeal pulsatile assist device (EPAD).

An extracorporeal pulsatile assist device (EPAD) is a valveless, single-chambered, pneumatically-actuated blood pump composed of a graft conduit, connecting ring, bladder, and blowmolded housing. This allows a simple and quick surgical procedure and is easily actuated with a conventional intraaortic balloon pumping console if desired. To evaluate in vivo pump functions, the EPAD was tested in calves as a left ventricular assist device for 6-24 days. The EPAD was well synchronized to the natural heart beat up to 130 bpm in the counterpulsation mode with mild systemic heparinization (active clotting time: 200-250 seconds). Heart rate, coronary flow and cardiac output were not significantly changed by on-off testing. However, the pump showed promising diastolic augmentation (10.8% increase in the diastolic pressure time index) in these chronic animal experiments.

Animals↗

Effects of design geometry of intravascular endoprostheses on stenosis rate in normal rabbits.

To investigate the effects of gaps between the individual wire coils of a shape memory Nitinol alloy intravascular endoprosthesis, 20 stents with and without gaps were implanted transluminally into the infrarenal abdominal aortas of 10 normal rabbits after balloon angioplasty. Digital subtraction angiography (DSA) was done at 4, 12, 16, 20, and 24 weeks after stent implantation to examine the stenosis rate and major side branch patency. Stenosis rate within stents with gaps were significantly lower than those without gaps: 8.1 +/- 5.0% versus 15.0 +/- 6.8% at 12 weeks, 13.6 +/- 6.0% versus 26.0 +/- 9.4% at 24 weeks by DSA, p greater than 0.005 and p less than 0.01 respectively. The maximum and mean neointimal thickness measured histologically at the time of animal death correlated significantly to the narrowest diameter obtained from the DSA studies, (r = 0.84 and r = 0.79, respectively, p less than 0.01). Greater hyperplasia of the neointima was evident in the stented arterial segments with stents without gaps compared with those with gaps (83 +/- 22 versus 187 +/- 46 microns mean thickness, p less than 0.001). The patency rate of the side branches in the stented arterial segment was significantly (p less than 0.05) higher in stents having gaps. These results suggest that the placement of gaps between wire pitches reduced the neointimal thickness within stents and prevented the obstruction of arterial side branches.

Angioplasty, Balloon↗

Biodegradable pericardial implants for bladder augmentation: a 2.5-year study in dogs.

Bladder augmentation using biodegradable pericardial tissue was evaluated in canine bladders. Acetic acid and acetic anhydride treated pericardial tissue grafts were stored in 75% ethanol for 18 to 27 months before implant. Ten dogs weighing 20 to 25 kg. were subjected to a 50% partial cystectomy. After careful separation of the mucosa, bladder muscle and adventitial layers a pericardial graft volumetrically equivalent to the portion of the bladder removed was sutured to the bladder remnant in 2 layers. In 1 control dog the bladder was opened, 50% of the bladder was removed and the bladder was closed primarily. In another control dog the excised bladder was replaced with fresh chemically treated patch material that was never subjected to ethanol storage. Excretory urography and cystography were performed on all dogs. Urodynamics with filling pressures and bladder volumes measured before and after the operation at intervals of up to 36 months confirmed that adequate bladder capacity was achieved. There were no operative complications. Postmortem histological evaluations revealed a smooth epithelialized inner surface with no traces of any surface irregularities or suture lines. The bladder apex showed an intact epithelium and the absence of a smooth muscle layer. The biodegradable acetylated tissue provides an intact structural reservoir for urine and serves as a template for epithelial regeneration. This permits volumetric bladder enlargement while the graft is progressively reabsorbed with time.

Animals↗

Damage to erythrocytes from long-term heat stress.

1. Erythrocytes are known to haemolyse in vitro at 48-50 degrees C. We hypothesized that erythrocytes might be damaged at much lower temperatures if they are incubated for prolonged periods. Erythrocytes from healthy human donors (n = 7) were incubated at 37, 40, 42, 44, 46 or 48 degrees C for 4-48 h. The haemolytic percentage and osmotic fragility were then measured by a modification of the method of Parpart et al. 2. Significant haemolysis and increased fragility were not observed at any temperatures after incubation for 4 h. However, the haemolytic percentage increased after incubation for 24 h at 44 degrees C (9.1 +/- 4.9%, P less than 0.01), 46 degrees C (52.4 +/- 14.1%, P less than 0.01) and 48 degrees C (98.0 +/- 2.6%, P less than 0.01) and after incubation for 48 h at 42 degrees C (9.8 +/- 4.5%, P less than 0.01) when compared with the values before heating (1.1 +/- 0.9%). The osmotic fragility also increased after incubation for 24 h at and above 42 degrees C. 3. Although heat-induced haemolysis and an increase in fragility have not been known to occur below 48 degrees C, these were quite apparent after incubation for 24-48 h at only 42 degrees C. This suggests that with regard to thermal effects, it is important to consider not only the temperature but also the duration of heating.

Cells, Cultured↗

Effects of temperature on phagocytosis of human and calf polymorphonuclear leukocytes.

The in vitro effect of temperature on the phagocytic function of human and calf polymorphonuclear leukocytes (PMN) was studied. To observe the PMN phagocytic function (PPF) at various temperatures, PMN from healthy human and calf donors were incubated with serum-opsonized fluorescent latex particles (diameter 1.66 microns) at 25, 37, 40, 42, 44, or 46 degrees C for 1 h and then observed for their phagocytic activity by fluorescent microscopy. At 25, 40, and 42 degrees C, human PPF was not significantly different from that at 37 degrees C (87%, 89%, and 80% vs. 93%). At 44 degrees C, PPF was noticeably depressed (19%, p < 0.05) when compared to that at 37 degrees C. Next, to determine the critical temperature and duration of exposure that would irreversibly damage PPF, PMN were preincubated at 42, 44, or 46 degrees C for 5-30 min before being subjected to a standard phagocytosis assay at 37 degrees C. The human PPF was significantly depressed after 30 min at 44 degrees C (33%, p < 0.05) or 10 min at 46 degrees C (30%, p < 0.05). In conclusion, neither human nor calf PPF was significantly altered at and below 42 degrees C. In contrast, the PPF was irreversibly and time-dependently damaged when incubated at and above 44 degrees C.

Animals↗

Cardiovascular implant calcification: a survey and update.

Calcification of cardiovascular prosthetic implants is a common and important problem. This review provides an update based upon the Conference on Cardiovascular Implant Calcification held as part of the 13th World Congress of the International Society for Heart Research, 1989. A variety of cardiovascular prostheses are affected clinically by calcification, including bioprosthetic heart valves, aortic homografts and trileaflet polymeric valve prostheses. In addition, experimental studies have demonstrated calcification of artificial heart devices in ventricular assist systems in long-term calf studies. The pathophysiology of this disease process is incompletely understood. A common element between the various types of cardiovascular implant calcification is the localization of calcific deposits to devitalized cells and membranous debris. Prevention of cardiovascular implant calcification by either biomaterial modifications or regional drug therapy (controlled release) is being investigated.

Animals↗

Effects of single-dose infusion of pyridoxalated-hemoglobin-polyoxyethylene conjugate solution on canine renal function.

Pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP) is an acellular oxygen-carrying red blood cell substitute made from outdated human red blood cells. This study assessed the effect of PHP on renal function when PHP was infused with a clinically relevant dosage. A single dose of PHP that contains 8% wt/vol each of hemoglobin and maltose or an 8% maltose control solution was infused into the intact circulation of eight dogs (five dogs for PHP and three for the control; 20 ml/kg each, at the rate of 2.5 ml/h/kg for 8 h) in the awake state. Serial measurements of glomerular filtration rate (GFR) and renal plasma flow (RPF) were carried out before and after infusion for up to 2 weeks, along with determinations of urine volume flow rate, fractional excretion of sodium (FES), and free water clearance (CH2O). The results showed an elevation of plasma colloid osmotic pressure by an average of 4.4 mm Hg immediately postinfusion with PHP solution. An average 23% decrease in GFR, without notable changes in RPF immediately postinfusion, was observed in the PHP group; the value returned to the preinfusion level by 1 week postinfusion. Increases in parameters such as urine output, FES, and CH2O, which were more pronounced in the PHP group, were observed for 24 h after the infusion in both groups. Light microscopic examination of kidney specimens taken at 2 weeks postinfusion revealed a slight degree of vacuole formation in approximately 80% of the proximal tubules in the PHP group. The tubules were devoid of typical pathologic features of acute renal failure, and the vacuoles did not cause any observable changes in the assessed tubular functions.

Animals↗

Vascular stenting in normal and atherosclerotic rabbits. Studies of the intravascular endoprosthesis of titanium-nickel-alloy.

Percutaneous transluminal balloon angioplasty would be more effective if the rate of recurrent stenosis were reduced. To evaluate the prevention of restenosis after percutaneous transluminal angioplasty, intravascular endoprosthetic stents of titanium-nickel-alloy were implanted transluminally in seven normal and 21 atherosclerotic rabbits. In normal rabbits, a 3.5-mm diameter stent was implanted in the aorta and a 2.5-mm diameter stent in the right iliac artery, which were followed with serial angiograms from 6 weeks (n = 7) to 8 months (n = 4). There was a mean stenosis of 13.1% in the 2.5-mm and 13.6% in the 3.5-mm stent. There was no significant narrowing compared with the adjacent control segments of artery; histopathology showed a thin, fibrous neointima with smooth muscle cells. Each atherosclerotic rabbit was balloon dilated at two separate stenotic sites; each site was 2.0 cm in length. The aortic site (with 28.8 +/- 13.8% mean stenosis [+/- SD]) was dilated with a 3.5-mm balloon, and the iliac site (with 36.5 +/- 14.2% stenosis) was dilated with a 2.5-mm balloon. In each site, an intravascular stent of corresponding diameter and 7-mm length was implanted in one half of the dilated segment, assigned randomly, and the other half served as the angioplasty control. Angiographically observed restenosis rates and the corresponding histopathology were similar in the atherosclerotic segments that had angioplasty alone versus the atherosclerotic segments that had angioplasty plus stenting. The mean neointimal thickness in the aortas and iliac arteries, respectively, measured 247 +/- 181 microns (+/- SD) and 218 +/- 77 microns after 6 weeks (n = 8) versus 321 +/- 168 and 308 +/- 189 microns after 20 weeks (n = 5, p = NS). At 20 weeks follow-up, there was 29.1 +/- 29.8% (median, 16.4%) stenosis in the aortic stent versus 38.9 +/- 24.1% (median, 34.0%) stenosis in the percutaneous transluminal angioplasty control segment of aorta (n = 5, p = NS) and 81.4 +/- 25.5% stenosis in the iliac artery stent versus 89.3 +/- 15.3% stenosis in the PTA control segment of the right iliac artery (n = 5, p = NS). Comparing stenotic arterial segments treated with angioplasty alone with angioplasty plus intravascular stenting in the atherosclerotic rabbits showed that there was no significant difference in either the histopathologic changes or the restenosis rates.

Alloys↗

Conjugated human hemoglobin as a physiological oxygen carrier--pyridoxalated hemoglobin polyoxyethylene conjugate (PHP).

Problems associated with specific physiological properties of Hb-based blood substitutes, such as low P50, short plasma half-life and nephrotoxicity are still major issues to be addressed. Extensive investigations aimed at overcoming these problems have resulted in the preparation of pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP). PHP was developed from human hemoglobin by two major chemical modifications; pyridoxylation for the purpose of lowering the oxygen affinity (P50 of 19.5 +/- 1.2 mmHg), and coupling with polyoxyethylene (POE) to increase its molecular weight (to approximately 90 kdaltons). The circulating half-life of PHP is about 40 hours in dogs. Toxicological and physiological studies including renal function assessments have demonstrated that PHP does not have untoward effects on major organ functions. Its efficacy in transporting oxygen has been shown in ET and intracoronary perfusion, and in in vitro studies with sickle cells. Studies to date suggest that PHP is a promising candidate as a physiological oxygen carrier. In this paper the properties of PHP, its safety and efficacy aspects, and its potential as a clinical oxygen carrier are reviewed based on studies conducted in the Author's laboratory.

Animals↗

Radionuclide assessment of the natural heart ejection fraction before and after LVAD implantation.

Complete pressure unloading of the ventricles can preserve ischemically damaged myocardium. Most clinical left heart assist device (LVAD) systems used after ischemic injury of the heart apply atrial cannulation which does not ensure pressure unloading. In order to assess the effect of the implantation of an intracorporeal LVAD on the function of the natural heart, we determined the ejection fraction (EF) in four male Holstein calves (90-105 kg) before and after insertion of a Cleveland Clinic pneumatic LVAD. A gated blood pool scan was obtained with a gamma camera after injection of 40 mCi Tc-labelled albumin. The animals were restrained in a sling to avoid movement artifacts. All animals showed a drop of 65 +/- 12% to 42 +/- 14% EF in the first postoperative (p.o.) week. Left ventricular output did not maintain sufficient blood pressure as assessed by pump-off tests. Systolic blood pressure dropped from 122 +/- 6.5 mm Hg to 81 +/- 6 mm Hg without pump support on the morning of the first p.o. day. Apical coring and possible restrained heart movement by the implanted LVAD may lead to impaired myocardial function that renders the individual LVAD dependent until adaptative corrections take place.

Animals↗

Titanium-nickel intravascular endoprosthesis: a 2-year study in dogs.

Twelve 5-mm-internal-diameter intravascular endoprostheses of noncorrosive, shape-memory titanium-nickel (TiNi) alloy were delivered transluminally by catheter and implanted in the iliac (n = 10) and femoral (n = 2) arteries of six normal dogs for either 1 or 2 years in order to evaluate the implantation technique and long-term effects. The patency rates were as follows: at 1 month, 92% (11/12); at 1 year, 100% 11/12 widely patent; 1/12 recanalized); and at 2 years, 100% (3/4 without stenosis; 1/4 with 20% stenosis). No migration, erosion, inflammation, surface thrombus, or stenosis of the side branches was seen; an absence of untoward angiographic and histopathologic effects was detected at 1 and 2 years. The neointima was completely endothelialized, without changes in thickness over time, 229.3 +/- 127.6 microns after 1 year and 223.3 +/- 216.7 microns after 2 years (p = not significant). The neointimal layer became thicker toward its distal aspect (p less than or equal to .05). Satisfactory delivery, long-term patency, and biocompatibility (manifested as a thin, stable neointima) were observed for the TiNi intravascular endoprosthesis at 1 and 2 years.

Animals↗

In vivo evaluation of a pyridoxylated-hemoglobin-polyoxyethylene conjugate.

A pyridoxylated-hemoglobin-polyoxyethylene conjugate (PHP) was developed from outdated human red cell hemoglobin through chemical modifications. The PHP has a mean molecular weight of approximately 90,000 daltons, with an acceptable P50 of 22 +/- 0.7 mmHg. This report describes exchange transfusion studies (ET) to a final hematocrit of 5 +/- 2% (n = 5) with PHP in mongrel dogs. Hespan (a plasma expander) was used as a control (n = 6). All the animals with PHP tolerated the procedure well and have survived more than 8 months to date. Five out of the six dogs receiving Hespan died within a week (p = 0.004). Reduction of hematological and coagulation parameters occurred following the ET and returned to the normal range by 4 weeks post ET. Serum electrolytes and renal function parameters (urea, creatinine) remained in the normal range. A transient slight increase in the hepatic enzyme SGOT was observed. At 2 weeks post ET open biopsies of major organs showed vacuolized cells in the liver and kidneys. Normal histology was noted at 3 months. The oxygen transporting properties examined showed effective oxygen delivery to the tissues for 6 hours post ET. PHP continued to transport oxygen for up to 48 hours studied post ET. Half-life of PHP in the circulation was 36.3 +/- 3.5 hours. Urinary loss of hemoglobin measured up to 48 hours after ET was 9.4 +/- 1.6% of the injected net hemoglobin. The PHP effectively supported life at lethal levels of anemia and is a physiologically acceptable solution. It has a relatively long intravascular residence time and transports oxygen to the tissue effectively for at least 6 hours.

Animals↗