Search PubMed⌕ Search

Biomedical subjects

H H Scheld

Publications and source records attributed to H H Scheld.

At least 145 records · Page 8Linked to original sources

Transplant vasculopathy.

Transplant vasculopathy constitutes the major impediment to long-term survival in heart transplant recipients. Within the "response to immune injury" paradigm, it can best be understood as the resultant of an orchestrated recipient immune response to the initial allogenic stimulus by graft vascular endothelium. This response incorporates the elaboration of complex coordinated cytokine patterns and corresponding cell types including B-lymphocytes, T-helper1- and T-helper2-cells, cytotoxic T-cells, macrophages, and polymorphonuclear cells. These attack the alloantigenic vascular endothelium and lead, by complex cytokine signaling, to migration of donor smooth muscle cells from the media into the intima, associated with a switch from the contractile to a synthetic phenotype. In conjunction with recipient T-cells, macrophages, and lipids, the intimal fibroproliferative growth of the donor vessel is hereby initiated.

Animals↗

[Effect of pre-existing lipids on calcinosis of swine heart valve bioprostheses. A study of a dynamic in vitro model].

Calcification is one of the main causes of failure of porcine bioprosthetic heart valves, a problem which has not been satisfactorily solved to date. Previous studies have shown that calcification is decreased in porcine heart valves that have undergone treatment for lipid extraction. The relation between lipid distribution and calcification of seven new commercially available porcine bioprosthetic heart valves (St. Jude Medical, Bioimplant) is assessed by Sudan red III staining to show preexisting lipids. All porcine bioprosthetic valves contained lipids to different degrees. Five valves were subjected to the pulsatile accelerated calcification process for 4 weeks. Distribution and level of calcification were evaluated by radiography and compared to the Sudan red-stained fatty areas. Comparison of the calcifications detected by radiography and the macroscopically detected lipids showed a coincidence of 57-66%. Two porcine bioprosthetic valves were histologically prepared and stained with Hematoxylin and von Kossa's stain, respectively. By light microscopy, the von Kossa staining revealed microcalcifications and polarizing microscopic investigation showed birefractive substances in areas with lipid deposits. These preexisting substances in porcine valve tissue may play a determinative role in the calcification of the tissue. Substantial studies are necessary to further determine the role of preexisting lipids in calcification.

Animals↗

Cerebral and systemic embolization during left ventricular support with the Novacor N100 device.

BACKGROUND: Patients undergoing implantation of left ventricular assist systems (LVAS) are prone to thromboembolic complications. We analyzed the incidence, clinical findings, and outcome of neurologic and systemic thromboembolic events (TE) in patients with the Novacor N100 LVAS. In a subset of patients, transcranial Doppler sonography was used to detect microembolic signals. METHODS: Thirty-six patients underwent implantation of a Novacor N100 LVAS for various reasons. The surgical procedure was elective in 18 patients and scheduled on an urgent or emergency basis in another 18 patients. The assist period lasted from 17 to 336 days (109 +/- 88 days); 22 patients were forwarded to heart transplantation after being supported for 140 +/- 87 days. RESULTS: Clinical cerebral embolism was evident in 17 patients (47%). Thromboembolic events were singular in 8 and multiple in 9 patients; in the latter up to 10 TE occurred (mean +/- SD, 1.4 +/- 2 TE). Leading neurologic symptoms were unilateral hemiplegia in 11, as well as ocular symptoms and aphasia in 12 patients each. Noncerebral TE were detected in 4 patients, 2 of whom underwent an emergency operation for intestinal and iliac artery occlusion. The incidence of TE did not correlate strongly with the interval of LVAS support. Cerebral computed tomography confirmed lesions in 58% of patients. Transcranial Doppler sonography detected microembolic signals on 67% of all recordings, with the microembolic signals being more frequent on days with clinically manifest TE. The outcomes were good, as only 2 patients suffer from neurologic sequelae. CONCLUSIONS: Thromboembolism is still a major threat for patients with LVAS implantation. Neurologic sequelae are frequent but have a favorable prognosis, and systemic complications occur considerably less often. Patient selection, adequate anticoagulation, and transcranial Doppler sonography may help to reduce the incidence of TE.

Adult↗

Neonatal mechanical bridging to total orthotopic heart transplantation.

BACKGROUND: Until recently, newborns with medically intractable cardiac failure caused by congenital malformations were mostly doomed to death because of the severity of the disease, which precludes a palliative operation, or because of fatal deterioration before availability of a suitable donor heart. METHODS: The recently developed paracorporeal pneumatically driven Medos HIA ventricular assist device offers a therapeutic option for these small infants because it is manufactured in various sizes and is even suitable for cardiac assistance in neonates with a body surface area less than 0.3 m2. RESULTS: We report our initial experience with this device, which we used for univentricular bridging to total orthotopic cardiac transplantation in 3 infants. The device was inserted to support the left ventricle in two instances and to support the right heart in one. Successful bridging to transplantation was achieved in 2 infants for periods of 2 and 7 weeks. CONCLUSIONS: Our experience demonstrates the feasibility of univentricular mechanical support followed by successful cardiac transplantation in infants and newborns.

Aortic Valve Stenosis↗

In vitro testing of bioprostheses: influence of mechanical stresses and lipids on calcification.

BACKGROUND: Structural valve deterioration of bioprostheses is mainly caused by the progressive development of calcification. Mechanical stresses or lipid deposits in porcine aortic leaflets have been proposed as major factors contributing to the calcification process. METHODS: A new test protocol consisting of nondestructive holographic interferometry, which allows a quantitative deformation analysis of heart valves, and accelerated dynamic in vitro calcification was used. The rapid calcification fluid contained a final combined calcium and phosphorus concentration of 130 (mg/dL)2 in barbital buffer solution. The calcification of 32 bioprostheses donated by different manufacturers (SJM Bioimplant, Biocor standard, Biocor No-React, Carpentier-Edwards SAV, Bravo, pericardial prototype) was assessed after up to 25 x 10(6) cycles by microradiography and the areas of calcification were compared with the holographic interferograms. The distribution of lipid droplets of four porcine prostheses were visualized by Sudan III stain before the calcification process. RESULTS: Most of the tested bioprostheses had areas presenting with stress concentrations, and the dynamic in vitro testing resulted in leaflet calcification corresponding to the holographic irregularities. A strong correlation between calcification and stress distribution or lipid accumulation was found (r = 0.72; r = 0.81, respectively). After 19 x 10(6) cycles, the Carpentier-Edwards SAV and the pericardial valves had significantly less calcification than other prostheses tested (p = 0.003), but the variation among individual prostheses from the same manufacturer was even more pronounced. CONCLUSIONS: Mechanical stresses or lipid accumulation seems to play an important role in the calcification process of bioprostheses. Quality control of bioprosthetic valves using holographic interferometry has the potential to predict calcification before implantation.

Aortic Valve↗

Successful treatment of a Novacor LVAD malfunction without repeat sternotomy.

Implantable left-ventricular assist devices have been remarkably free of mechanical failures. We describe an uncommon Novacor N100 PCq LVAS malfunction caused by an internal short circuit of the device due to urine aspiration via the vent line. Device replacement was managed via a subcostal approach without sternotomy. Patient recovery was uneventful and successful transplantation was performed one month after the device exchange.

Adult↗

Suppression of panel-reactive antibodies by treatment with mycophenolate mofetil.

"Panel Reactive Antibody" (PRA) testing is commonly used to assess the pretransplant antibody status in order to estimate the risk of an adverse humoral response following transplantation. We report on a female patient with end-stage cardiac failure suffering from acute myocarditis who underwent implantation of a left-ventricular assist device (Novacor, Baxter Healthcare Corp. Oakland, CA). During evaluation for heart transplantation, a PRA level of 50-70% was detected. After treatment with mycophenolate mofetil at a dosage of 2 g daily, PRA levels declined within one week to 0-5%, and remained low after discontinuation of the immunosuppressive drug. We feel that pretreatment of patients with elevated PRA levels with mycophenolate mofetil is well justified.

Acute Disease↗

Effect of platelet inhibitors on thromboembolism after implantation of a Novacor N100--preliminary results.

BACKGROUND: Left-ventricular assist device implantation (LVAD) is still associated with thromboembolism as the optimal anticoagulation is still unclear. We report on the effects of adding platelet inhibitors to our anticoagulation regimen in our Novacor LVAD program. METHODS: Oral platelet aggregation inhibitors (aspirin 330 mg + dipyridamole 75 mg, three times per day) were added to the heparin/phenprocoumon treatment in 9 patients starting on postoperative day 3 to 7 (group A). Of the previous 41 patients, the last 20 patients served as a control group (group B), to reduce any learning curve effect. RESULTS: The mean interval of mechanical support between the two groups was comparable (group A vs B: 148 +/- 127 vs 104 +/- 61 days, n.s.). Accordingly, the cumulative support was much lower in group A (1051 days) as compared to group B (2091 days). In group B, 10 patients (50%) developed clinically evident thromboembolism. The number of events ranged from 1 to 10 (mean 1.4 +/- 2.3), with a total of 32. With addition of platelet inhibitors, the incidence of cerebral embolism dramatically dropped, as only one patient presented with transient ischemic attacks in group A (p < 0.05). Thoracic bleeding as defined by excessive drainage losses requiring redo thoracotomy did not increase (group A vs B: 22% vs 20%, n.s.). CONCLUSION: Addition of platelet inhibitors to heparin/phenprocoumon effectively prevents thromboembolism. However, platelet inhibitors should be postponed until sufficient hemostasis is achieved, since too early administration is associated with an increased risk of bleeding.

Anticoagulants↗

Identification and expression of a novel isoform of cAMP response element modulator in the human heart.

In end-stage human heart failure, excessive beta-adrenergic stimulation of the cAMP-dependent signaling pathway due to enhanced endogenous catecholamines is hypothesized to contribute to expressional alterations of myocardial regulatory proteins. The cAMP response element modulator (CREM) regulates the transcription of cAMP-responsive genes and might be involved in the regulation of cardiac gene expression. Using the reverse transcription polymerase chain reaction, we identified a novel CREM mRNA, CREM-Ib deltaC-X, in the human heart. Overexpression of CREM-Ib deltaC-X decreased cAMP response element (CRE) -mediated gene transcription in HIT-T15 cells, and this activity was assigned to the part of the sequence encoding putative internally translated proteins. Two of three possible internally translated proteins were immunologically identified in cells overexpressing CREM-Ib deltaC-X tagged with the hemagglutinin epitope of the influenza virus. Both proteins were expressed in bacteria and showed CRE-specific DNA binding, formation of heterodimers with the cAMP response element binding protein (CREB), and inhibition of CREB's binding to the CRE. CREM expression was detected on the mRNA and protein levels in the human heart. We conclude that CREM-Ib deltaC-X generates internally translated repressors of CRE-mediated gene transcription, suggesting the first example for the existence and function of human cardiac CREM.

Animals↗

Cardiac surgery without the use of cardiopulmonary bypass: the challenges.

Minimally invasive bypass grafting of the internal thoracic artery to the left anterior descending artery has become routine in many institutions. Currently, indications for single vessel revascularization are expanding to those patients not suitable to be operated upon using extracorporeal circulation, but surgeons remain rather reluctant when multivessel disease is concerned. In such cases, the 'hybrid technique', i.e. single vessel bypass grafting followed by percutaneous transluminal coronary angioplasty at a different site, seems to be a more appropriate alternative. Despite the merits of minimally invasive surgery, the majority of surgeons do not believe that it is possible to achieve the same quality of anastomosis on a beating heart as on an arrested heart.

Journal Article↗

The influence of body temperature on transient evoked otoacoustic emissions.

Thirty patients undergoing open heart surgery under induced hypothermia had transient evoked otoacoustic emissions (TEOAE) recorded during cooling to 26.07 degrees C (standard deviation (SD) 4.25 degrees C) vesically measured temperature and 24.86 degrees C (SD 4.7 degrees C) nasopharyngeally measured temperature respectively. Subsequently tè patients were rewarmed until normal body temperature was reached again. There was a clear influence of body temperature on the amplitudes and reproducibilities of the TEOAE. The relationship of temperature and amplitude or reproducibility during the cooling phase was significantly different from that during rewarming. No TEOAE were measurable during cooling at a mean temperature lower than 33.41 degrees C (SD 2.04 degrees C) vesical temperature and 30.16 degrees C (SD 3.0 degrees C) nasopharyngeal temperature respectively. During rewarming the echoes became recognizable again at a mean temperature of 28.75 degrees C (SD 3.38 degrees C) vesical temperature and 27.49 degrees C (SD 2.99 degrees C) nasopharyngeal temperature. These results suggest a hysteresis in the relationship between the amplitude of TEOAE and temperature, similar to the well-established relationship between evoked potentials and temperature.

Adolescent↗

Relation of urokinase-type plasminogen activator expression to presence and severity of atherosclerotic lesions in human coronary arteries.

Urokinase-type plasminogen activator (UPA) has been implicated in a broad spectrum of pathological processes - e.g. cell adhesion, migration and proliferation and matrix remodeling - that are considered important features of atherogenesis and plaque disruption. In this study, we have analyzed the content and expression of UPA in human coronary arteries and its relation to the presence and severity of atherosclerotic lesions. Segments of coronary arteries obtained from human heart explants (n = 15) were classified by the presence and types of atherosclerotic lesions. UPA was quantitatively determined in protein extracts of the intimal and medial layers. In situ hybridization and immunohistochemical analyses were performed on serial sections of representative tissue specimens. UPA was detected in the extracts as pro-UPA, UPA complexed to plasminogen activator inhibitor-1, or as otherwise inactive UPA antigen, but not in the active two-chain form. Both functional and total UPA were increased several-fold in extracts of advanced lesions, while the ratios of functional over total UPA showed the opposite trend suggesting enhanced UPA inactivation and turnover. UPA expression in early atherosclerotic lesions was particularly prominent in areas of proliferating SMCs in the abluminal part of the neointima, whereas in advanced lesions UPA was widely expressed in macrophage-rich areas adjacent to the rims and shoulder regions of the necrotic cores. The results strongly suggest a causal involvement of UPA in coronary atherogenesis and its clinical outcome.

Coronary Artery Disease↗

Holographic interferometry and in vitro calcification: comparing pericardial versus porcine bioprostheses.

BACKGROUND AND AIMS OF THE STUDY: Structural valve deterioration of bioprostheses is mainly caused by progressive calcification. It has not yet been convincingly demonstrated whether pericardial or porcine bioprostheses are more prone to calcification. METHODS: A previously described in vitro test protocol consisting of non-destructive holographic interferometry, which permits quantitative deformation analysis of heart valves and accelerated dynamic calcification in vitro was used to evaluate five stented pericardial bioprostheses of different sizes and design (three or two leaflets) from one manufacturer. The extent of calcification was assessed after up to 20 x 10(6) cycles in the valve tester by microradiography, and areas of calcification were compared by holographic interferometry using computerized image processing. Calcification was confirmed by EDX-analysis and Von Kossa staining. Results were compared with in vitro testing of 25 porcine bioprostheses from different manufacturers. RESULTS: The tested pericardial bioprostheses had an individual distribution of mechanical stresses detectable by holographic interferometry, which resulted in different calcification of valve leaflets. A strong correlation between calcification and stress distribution was found (correspondence of affected areas: 82.3 +/- 10.1%, r = 0.97). Variability in calcification and stress distribution, respectively, of pericardial valves compared well with our findings for porcine prostheses. Overall, the extent of leaflet calcification was not statistically different for pericardial and porcine bioprostheses (p = 0.21). CONCLUSIONS: The biological material of bioprostheses (pericardial versus porcine) does not seem to be the crucial factor in the calcification process. Mechanical stresses detectable by holographic interferometry have a more pronounced impact and predict calcification of individual prostheses, at least in the in vitro setting.

Animals↗

Selection and outcome of ventricular assist device patients: the Muenster experience.

BACKGROUND: Because the number of patients on the waiting list for transplantation is increasing and the stagnation in the number of organs donated has led to a more restrictive listing for transplantation, an increased fraction of patients needs to be bridged mechanically. We examined the hypothesis that selection of these patients with regard to urgency status is critical in determining outcome. METHODS: A cohort of 631 patients referred for transplantation to our center between January 1, 1990, and December 31, 1996, was analyzed. Two hundred ninety-seven patients were listed for transplantation and 157 were given transplantation. Forty-one patients had to undergo ventricular assist device implantation (n=34, Novacor; n=6, TCI Heartmate; n=1, Medos), 39 for bridging to transplantation and 2 for permanent support. Initial transplantation evaluation data were analyzed in 3 subgroups (elective bridging, urgent bridging, emergency bridging) and compared with another and with other patients referred for transplantation, specifically those who did not have to be bridged on the waiting list. RESULTS: Patients who underwent elective or urgent assist device bridging were younger and more compromised than the rest of patients accepted on the waiting list (higher functional class, lower mean arterial pressure, lower cardiac index, lower serum sodium, higher pulmonary capillary wedge pressure). In the elective group, overall survival including perioperative mortality rate was better than in the urgent/emergency group and at least as good as in patients who were stable on the waiting list and did not undergo heart transplantation during follow-up. This should prompt cardiologists and cardiac surgeons to consider assist device implantation earlier.

Adult↗

Emergency versus elective/urgent left ventricular assist device implantation.

BACKGROUND: The risk and outcome in patients undergoing left ventricular assist device (LVAD) implantation on an emergency basis is still unclear. METHODS: Since April 1993, 40 patients received a Novacor and 8 patients a Heartmate LVAD in our institution. Patients with emergency LVAD placement were compared with the remainder in a retrospective manner. Parameters studied included underlying heart disease, preimplantation dysfunction of kidney, liver, lung, and cerebrum, interval of mechanical support, outcome, and complications. RESULTS: Patients with emergency LVAD placement predominantly were seen with postcardiotomy heart failure (47%) or acute myocarditis (20%) (group A) whereas elective and urgent candidates for LVAD implantation mainly had dilative cardiomyopathy (67%) or ischemic heart disease (30%) (group B). The incidence of secondary organ failure was significantly higher for all organs in group A patients (p < .01). Mean support interval in patients who underwent emergency LVAD implantation was lower (74+/-79 days vs 115+/-80 days), and fewer patients could be forwarded to heart transplantation in this group (22% vs 78%, p < .01). Moreover, bleeding complications were increased in group A (66% vs 30%, p < .01), but not thromboembolism and infection. CONCLUSION: In conclusion, the overall success rate after emergency LVAD implantation was lower, with bleeding being the most frequent complication. To achieve acceptable outcomes in disastrous situations, LVADs should be placed as early as possible.

Adult↗