Ventricular tachycardia caused by cardiac rhabdomyoma in a young adult with tuberous sclerosis.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to H H Scheld.
Explore the source record for details and available documents.
We report on an unusual case of surgical repair for anomalous origin of the coronary artery from the pulmonary artery, in a young patient who underwent tunnel repair with concomitant heterotopic heart transplantation to support severely impaired left ventricular function. Four years later, the graft was removed after confirmation of ventricular arrest and excellent recovery of the patient's own heart.
Explore the source record for details and available documents.
We report on our first clinical use of a Perma-Flow graft for coronary artery bypass surgery (CABG). It may well be that repeated successful use of this graft will offer a chance for revascularization to patients who might otherwise have been denied for lack of appropriate vessels.
OBJECTIVE: The results of surgical therapy can only be accurately judged if the patients' characteristics and their impact on the outcome are known. The purpose of this study was to identify the risk factors of contemporary thoracic surgery, which could serve as a basis for a risk-matched comparison of different surgical techniques. METHODS: The data of 15 patients' undergoing thoracic surgery were prospectively documented. The outcome of the various operative procedures applied was statistically correlated with the access procedure, sex, age, body mass, dignity of underlying disease and six concomitant diseases. RESULTS: Four patients died within 30 days of surgery (mortality: 2.6%). Morbidity comprising all complications (class I) and morbidity comprising only complications of consequence for postoperative therapy (class II) rose with the number of concomitant diseases (50%/0% with no concomitant disease, 89%/33% with more than three concomitant diseases). Univariate testing identified malignant disease (P = 0.002), male sex (P = 0.003), body mass index of less than 20 and more than 27 kg/m of the expected level according to the Quetelet rule (P = 0.013) and a combination of concomitant respiratory and cardiocirculatory disease (P = 0.022) as being associated with class I morbidity. Male sex was significantly coincident with class II morbidity (P = 0.020). Logistic regression analysis demonstrated that these characteristics also had independent influence on class I morbidity (P = 0.022, P = 0.001, P = 0.023, P = 0.028). CONCLUSION: It is concluded that these characteristics are important predictors of morbidity of thoracic surgery. If a non-randomized comparison of the outcome of thoracic operations or different access strategies like thoracotomy or thoracoscopy is intended, at least these patient features should be documented and used as a basis for matching pairs.
Implantable left-ventricular assist devices (LVAD) are successfully used as a bridge to transplant if the patient's condition is worsening and no donor organ is available. They allow recovery of compromised organ function. However, postoperative bleeding, thrombemboelism, and right-heart failure may jeopardize the important improvement of organ function and may even lead to death. We introduce our strategy for implantation of the Novacor LVAD system, which aims at minimal bleeding and maintained right-heart function. The Novacor LVAD was implanted with the heart beating during extracorporeal circulation in 8 patients, 3 of whom had previous cardiac surgery. Postoperatively, no patient developed right heart failure or had to undergo redo thoracotomy.
Refinements in patient assessment, perioperative management and surgical technique have considerably improved the outcome and thus widened the indication for coronary bypass surgery. General indications for CABG surgery include left main stem stenosis or involvement of the LAD. Currently, there is no optimal technique or management, rather an individualized strategy considering the individual findings and risks. However, the trend points toward a wider use of arterial conduits and avoidance of proximal anastomoses. Recently evolving strategies including minimal invasive surgery and transmyocardial laser revascularization may indicate the beginning of a new era and show that coronary bypass grafting is still an evolving field for cardiac surgeons.
We report on a 56-year-old patient who underwent coronary artery bypass grafting, tricuspid valve replacement, and pacemaker implantation within 49 months after heart transplantation. This case readily demonstrates that multiple cardiac procedures can be safely performed after heart transplantation and may thus serve as an alternative to retransplantation.
BACKGROUND: The aim of this study was to investigate coronary compliance in patients early and 71.8 weeks after orthotopic heart transplantation. METHODS: Thirty patients (mean age 51.4 years, women n = 6) underwent coronary angiography early after orthotopic heart transplantation (mean interval 11.6 +/- 5.5 weeks), by which time 12 recipients had already been treated for episodes of rejection. A total of 153 different coronary segments were investigated using a mechanical 30 MHz intravascular ultrasound system. In all segments, the intimal index and the circumferential extension of the vessel wall, which had a three-layered appearance, were assessed. Systolic-diastolic changes in area, and pressure with respect to vessel wall area, were used to study normalized compliance. All measurements were repeated in a subgroup of 13 patients 71.8 +/- 10.7 weeks after transplantation. RESULTS: At the first investigation, the mean intimal index of all estimated cross-sectional areas was 0.07 +/- 0.10. The mean circumferential extension of the 'three-layered' coronary vessel wall was 74 degrees +/- 101 degrees. No correlation could be found between normalized compliance and the intimal index (r = -0.322, P < 0.001) or between normalized compliance and the circumferential extension of the three-layered vessel wall (r = -0.362, P < 0.001). Donor age did not correlate with normalized compliance either (r = -0.515, P = 0.004). In 12 patients with proven rejection periods before the first investigation, normalized compliance was significantly lower (1.76 +/- 0.81 mmHg-1) than in those without rejection (2.95 +/- 1.22 mmHg-1, P = 0.005). Both the intimal index and the circumferential extension of the three-layered architecture of the vessel wall were significantly higher in recipients with rejection periods. A comparison of the subgroup of 13 recipients between first and second investigation showed that the intimal index increased slightly from 0.03 +/- 0.03 to 0.09 +/- 0.13 (ns) 71.8 weeks after transplantation, but that normalized compliance did not differ significantly between the first and the follow-up investigation. CONCLUSIONS: Early after orthotopic heart transplantation, normalized compliance does not correlate with donor age or the extent of atherosclerotic vessel alterations identifiable by intravascular ultrasound. Early rejection periods are associated with reduced coronary arterial compliance. Using intravascular ultrasound, this adverse functional effect on arterial compliance can be observed together with an increase in the intimal index.
1. Diadenosine hexaphosphate (AP6A) exerts vasoconstrictive effects. The purpose of this study was to investigate whether AP6A has any effect on cardiac function. 2. The effects of AP6A (0.1-100 microM) on cardiac contractility and frequency were studied in guinea-pig and human isolated cardiac preparations. Furthermore, the effects of AP6A on the amplitude of the L-type calcium current, on the adenosine 3':5'-cyclic monophosphate (cyclic AMP) content and on the phosphorylation of regulatory phosphoproteins, i.e. phospholamban and troponin inhibitor, were investigated in guinea-pig isolated ventricular myocytes. 3. In isolated spontaneously beating right atria of the guinea-pig AP6A exerted a negative chronotropic effect and reduced the rate of contraction maximally by 35% (IC20 = 35 microM). 4. In isolated electrically driven left atria of the guinea-pig AP6A exerted a negative inotropic effect and reduced force of contraction maximally by 23% (IC20 = 70 microM). 5. In isolated electrically driven papillary muscles of the guinea-pig AP6A alone was ineffective, but attenuated isoprenaline-stimulated force of contraction maximally by 23% (IC20 = 60 microM). Furthermore, AP6A attenuated the relaxant effect of isoprenaline. 6. In human isolated electrically driven ventricular preparations AP6A alone was ineffective, but attenuated isoprenaline-stimulated force of contraction by maximally 42% (IC20 = 18 microM). Moreover, AP6A attenuated the relaxant effect of isoprenaline. 7. All these effects of AP6A were abolished by the selective A1-adenosine receptor antagonist 1,3-dipropyl-cyclopentyl-xanthine (DPCPX, 0.3 microM), whereas the M-cholinoceptor antagonist atropine (10 microM) and the P2-purinoceptor antagonist suramin (300 microM) failed to abolish the effects of AP6A. 8. AP6A 100 microM had no effect on the amplitude of the L-type calcium current, but attenuated isoprenaline-stimulated L-type calcium current. The maximum of the current-voltage relationship (I-V curve) was shifted to the left by isoprenaline and additional application of AP6A shifted the I-V curve back to the right to the control value. The phosphorylation state of phospholamban and the troponin inhibitor was unchanged by AP6A alone, but was markedly attenuated by AP6A in the presence of isoprenaline. Cyclic AMP levels remained unchanged by AP6A, even after stimulation with isoprenaline. 9. In summary, AP6A exerts negative chronotropic and inotropic effects in guinea-pig and human cardiac preparations. These effects are mediated via A1-adenosine receptors as all effects were sensitive to the selective A1-adenosine receptor antagonist DPCPX. Furthermore, the effects of AP6A on cyclic AMP levels, protein phosphorylation and the L-type calcium current are in accordance with stimulation of A1-adenosine receptors.
The volume of current implantable cardioverter defibrillators (ICD) is not convenient for pectoral implantation. One way to reduce the size of the pulse generator is to find a more effective defibrillation pulse waveform generated from smaller volume capacitors. In a prospective randomized crossover study we compared the step-down defibrillation threshold (DFT) of a standard biphasic waveform (STD), delivered by two 250-microF capacitors connected in series with an 80% tilt, to an experimental biphasic waveform delivered by a single 450-microF capacitor with a 60% tilt. The experimental waveform delivered the same energy with a lower peak voltage and a longer duration (LVLD). Intraoperatively, in 25 patients receiving endocardial (n = 12) or endocardial-subcutaneous array (n = 13) defibrillation leads, the DFT was determined for both waveforms. Energy requirements did not differ at DFT for the STD and LVLD waveforms with the low impedance (32 +/- 4 omega) endocardial-subcutaneous array defibrillation lead system (6.4 +/- 4.4 J and 5.9 +/- 4.2 J, respectively) or increased slightly (P = 0.06) with the higher impedance (42 +/- 4 omega) endocardial lead system (10.4 +/- 4.6 J and 12.7 +/- 5.7 J, respectively). However, the voltage needed at DFT was one-third lower with the LVLD waveform than with the STD waveform for both lead systems (256 +/- 85 V vs 154 +/- 51 V and 348 +/- 76 V vs 232 +/- 54 V, respectively). Thus, a single capacitor with a large capacitance can generate a defibrillation pulse with a substantial lower peak voltage requirement without significantly increasing the energy requirements. The volume reduction in using a single capacitor can decrease ICD device size.
Adequate sensing is a basic requirement for appropriate therapy with ICDs. Integrated sense pace defibrillation leads, which facilitate ICD implantation, show a close proximity of sensing and defibrillation electrodes that might affect the sensing signal amplitude by the high currents of internal defibrillation. In 99 patients, we retrospectively examined two integrated sense pace defibrillation leads, either both with a distance of 6 mm between the tip of the lead (sensing cathode) and the right ventricular defibrillation electrode (sensing anode) or one with a distance of 12 mm. Three seconds after a shock of 20 J, mean sensing signal amplitude during sinus rhythm (SR) decreased from 10.5 +/- 4.3 mV to 5.1 +/- 3.7 mV (P < 0.001) for the 6-mm lead, but showed no significant decrease for the 12-mm lead. The degree of signal reduction was inversely related to the time passed since defibrillation. Significant differences in reduction of sensing signal amplitude concerning monophasic and biphasic shocks could not be observed. Mean sensing signal amplitude of VF after shocks that failed to terminate it decreased in the same order as during SR (from 8.3 +/- 4.1 mV to 4.1 +/- 3.2 mV), but resulted in no failure of redetection during ongoing VF. DFTs did not differ for the 6-mm and the 12-mm lead. In conclusion, close proximity of the right ventricular defibrillation coil to the sensing tip of an integrated sense pace defibrillation lead causes energy and time related reduction in sensing signal amplitude after defibrillation, and might cause undersensing in the postshock period. A new lead design with a more proximal position of the right ventricular defibrillation coil avoids these problems without impairing DFTs.
BACKGROUND AND PURPOSE: The use of left ventricular assist devices has become an established method in bridging patients with end-stage cardiac failure to heart transplantation. Since thromboembolism is one of the major complications, we undertook this study to evaluate the clinical significance of Doppler microembolic signals (MES) in patients with left ventricular assist devices. METHODS: Six patients with left ventricular assist devices were monitored for MES with transcranial Doppler ultrasonography during the first 30 postoperative days. Additionally, repeated (10 per day and patient) and prolonged (3 hours per patient) monitorings were performed to assess the adequacy of the 30-minute recordings. Three observers evaluated 30 randomly assigned monitorings in a blinded fashion to assess the interobserver variability. The relation between MES counts and clinical, radiological, hemostaseological, and pump flow parameters and the predictive value of MES counts regarding the occurrence of embolic events was evaluated. RESULTS: Ten ischemic cerebrovascular accidents and 2 peripheral thromboembolic events occurred during the observation period of 177 days (total incidence, 6.8%). MES were found in 143 of 170 monitorings (84.1%). Their counts were significantly higher on days with clinically manifest embolic events as compared with event-free days (18.5 [3-74] versus 4 [0-52], respectively, median and 95% CI; P < .001, Mann-Whitney). The predictive value of MES counts above 7 per 30 minutes was high (75%). Significant differences in the incidence and counts of MES as well as in the incidence of clinically manifest embolic events were noted among the six patients (all P < .01) without equal differences in anticoagulant treatment or pump flow. Interobserver agreement was high (p = .78 to .89, unpaired Student's t test). Considerable short- and long-term intrapatient variations of MES counts, without consistent pattern, were noted. CONCLUSIONS: Serial monitoring for MES is prognostically superior to single monitorings in patients with left ventricular assist devices. In the future, this new application mode may individually guide anticoagulation strategies and even influence the decision regarding early cardiac transplantation versus long-term use of the assist devices.
Laparoscopic and thoracoscopic surgery have had a tremendous impact on adult surgery, but are still rarely used in children. In the past 3 years 168 children have been treated endoscopically in the three cooperating institutions. The course of all patients was documented prospectively in order to determine the value and prove the safety of endoscopic surgery in children. The operations performed endoscopically comprised appendectomy (n = 39), diagnostic procedures (24), adhesiolysis (n = 22), cholecystectomy (n = 13), bowel resection (n = 8), pyloromyotomy (n = 6), ovarial resection (n = 6), hiatus hernia repair (n = 22), splenectomy (n = 6), first stage of Fowler-Stephens operation for kryptorchidism (n = 3) and interruption of persistent botallic ducts (n = 6) in preterm infants. Apart from four wound infections (2.4%) following perforated appendicitis, one of which required laparotomy for perityphlitic abscess there were no serious complications. No patient died, and overall morbidity related to the procedure was 1.8% (i.e. incidence of uneventful minor intraoperative complications). Furthermore endoscopic surgery provides a better diagnostic survey of the abdomen or thorax so that missing of secondary pathology is unlikely. Pain and reflectory impairment of bowel-function or respiration were diminished, the aesthetic results were excellent and hospitalization could be reduced to a minimum. It is concluded that laparoscopic and thoracoscopic surgery are safe and reliable procedures for children and yield very encouraging results.
Glomus caroticum tumours belong to the non chromaffine paragangliomas. As the incidence is very poor with 1% in the collective of a vascular-surgery department, the correct diagnosis is preoperatively only found in 10-20% of the cases. The early detection of primary- or recurrence-tumour is important for the surgical proceedings. With advanced tumour-stage, i.e. with involvement of the carotid artery in the tumour-process, the perioperative mortality increases. Furthermore nerve lesions following surgical tumour-resection as a complication are more frequent. This case-report point out the importance of the somatostatin-receptor-scintigraphy in the differentiation of glomus caroticum tumour-recurrence and postoperative scar. In our patient the suspicion of tumour-recurrence came up already 2 years ago, but could not be verified by MRT and angiography.
Renal failure after cardiac surgery using cardiopulmonary bypass (CPB) is well understood for infants, children and adults. The perioperative risk factors after CPB for immature kidneys in newborns are not well known. This retrospective study investigates perioperative risk factors for renal insufficiency in neonates. I) Preoperative: Age; weight, performed angiography, amount of dye used in angiography, renal disease and creatinine. II) Intraoperative: Duration of operation, duration of MAP < 40 mmHg, use of deep hypothermia, in-out fluid balance, duration of CPB, duration of circulatory arrest and cross-clamp time. III) Postoperative: Creatinine, use of catecholamines, use of nitroglycerine (NG) or phosphodiesterase inhibitors (PDI) and additional antibiotics. From Jan. 1990 to Dec. 1994 50 neonates underwent cardiac surgery using CPB (n = 23 transposition of the great arteries; n = 4 pulmonary atresia; n = 6 critical pulmonary stenosis; n = 5 hypoplastic left heart syndrome; n = 3 Ebstein's anomaly; n = 2 interrupted arch with hypoplastic left ventricle; n = 2 single ventricle; n = 1 each: double outlet right ventricle, tricuspid atresia, critical aortic stenosis, rhabdo-myosarkoma, corrected transposition of the great arteries.) Thirty-one patients entered the study. Depending on the postoperative creatinine level two groups (group I: creatinine <1 mg/dl and group II: >1 mg/dl) were created. The diureses between the two groups did not differ. Comparing the patients of group I vs. group II, patients of group I were younger (mean age: 7.7 d. vs. 11.4 d), lighter (mean weight: 3260 g vs. 3430 g), less had angiography (44% vs. 77%), received more dye (mean amount: 14 ml vs. 7 ml), the duration of MAP < 40 mmHg while on CPB was longer (mean duration 3 min vs. 21 min), more patients were operated on using deep hypothermia (55% vs. 27%), the postoperative in-out-fluid balance was more positive (mean balance +413 ml vs. +221 ml), received postop. more frequently high doses of catocholamines and less common NG or PDI, but more often additional antibiotics. The duration of circulatory arrest (mean time: 60 min vs. 55 min) and cross clamp time (mean time: 68 min vs. 65 min) seems not to be a risk factor and vasodilators given simultaneously with catecholamines may have preventive effects on postoperative renal insufficiency. Immature kidneys may play an outstanding role in the susceptibility of damaging factors. Further investigation with a larger number of patients allowing to obtain statistical significant risk factors are required.
BACKGROUND AND AIMS OF THE STUDY: Limited durability of porcine bioprostheses is mainly caused by the progressive development of calcification. We tested the hypothesis that hidden tissue anomalies or unfavorable stress concentrations of commercially available bioprostheses may lead to later calcification and dysfunction. Application of holographic interferometry for non-destructive testing of biological heart valves enables a full-field analysis of heart valves and reveals deformation irregularities of valve tissue. MATERIAL AND METHODS: We developed an accelerated calcification protocol for bioprosthetic heart valves including an accelerated pulsatile valve tester for simultaneous testing of 10 heart valves under identical conditions and a rapid synthetic calcification fluid containing a final Ca x P of 130 (mg/dl)2 in barbital buffer solution. Ten porcine bioprostheses (St. Jude Medical, Bioimplant) were assessed by holographic interferometry and subjected to the pulsatile accelerated calcification process. Distribution and amount of calcification was evaluated by microradiography after 12 x 10(6) and 19 x 10(6) cycles, respectively. Areas of irregular fringe patterns detected by holography as well as areas of calcification were calculated and compared using a personal computer. RESULTS: All tested bioprostheses had localized or extended areas with holographic irregularities and the accelerated valve testing protocol resulted in even macroscopically visible calcifications at various sites. Comparative analysis of the obtained microradiographs revealed that 74.2% +/- 6.0% of calcified leaflet areas lay within the previously detected holographic anomalies. CONCLUSIONS: Our first results show a strong correlation between holographic anomalies and calcification of porcine bioprostheses. We conclude that suitable methods for evaluation and quality control of bioprosthetic heart valves are available and seem to be predictive with regard to valve calcification.
UNLABELLED: The biodistribution of the fatty acid analog [131I]PHIPA 3-10, was compared to the flow tracer 99mTc-sestamibi by quantitative analysis in a dual-isotope study performed during a heart transplantation. METHODS: Iodine-131-PHIPA 3-10 and 99mTc-sestamibi were injected simultaneously approximately 20 min prior to the start of surgical procedure. Scintigraphic images of the sliced explanted heart were compared to the preoperative in vivo scans using [123I]PHIPA 3-10, 201TI and 99mTc-sestamibi. In 14 tissue samples of the explanted heart, the radioactive contents from [131I]PHIPA 3-10 and 99mTc-sestamibi were calculated as %ID/g-values and correlated with the corresponding histology. RESULTS: In the preoperative scans, a mismatch of fatty acid uptake and perfusion ([123I]PHIPA 3-10 > flow) was observed which indicated residual viable myocardium, while a matched defect was associated with scar. In viable myocardium, there was a significantly higher accumulation of [131I]PHIPA 3-10 compared to 99mTc-sestamibi (mean 5.9 x 10(-3) versus 2.7 x 10(-3)%ID/g),whereas in scars the uptake of both tracers was comparable (1.2 x 10(-3) versus 1.4 x 10(-3)%ID/g). CONCLUSION: Myocardial viability can be defined more accurately with radioiodinated PHIPA 3-10 than with 99mTc-sestamibi. The differences of biodistribution in viable myocardium and scars indicate that not only perfusion but also the metabolic state of the myocardium can be evaluated with radioiodinated PHIPA 3-10.