Search PubMed⌕ Search

Biomedical subjects

H H Liu

Publications and source records attributed to H H Liu.

At least 19 recordsLinked to original sources

Search for invisible decays of eta and eta' in J/psi --> phi eta and phi eta'.

Using a data sample of 58 x 10(6) J/psi decays collected with the Beijing Spectrometer II detector at the Beijing Electron Positron Collider, searches for invisible decays of eta and eta' in J/psi to phi eta and phi eta' are performed. The phi signals, which are reconstructed in K+K- final states, are used to tag the eta and eta' decays. No signals are found for the invisible decays of either eta or eta', and upper limits at the 90% confidence level are determined to be 1.65 x 10(-3) for the ratio B(eta-->invisible)/B(eta --> gamma gamma) and 6.69 x 10(-2) for B(eta' --> invisible)/B(eta' --> gammagamma). These are the first searches for eta and eta' decays into invisible final states.

Journal Article↗

An interpretation of potential scale dependence of the effective matrix diffusion coefficient.

Matrix diffusion is an important process for solute transport in fractured rock, and the matrix diffusion coefficient is a key parameter for describing this process. Previous studies have indicated that the effective matrix diffusion coefficient values, obtained from a large number of field tracer tests, are enhanced in comparison with local values and may increase with test scale. In this study, we have performed numerical experiments to investigate potential mechanisms behind possible scale-dependent behavior. The focus of the experiments is on solute transport in flow paths having geometries consistent with percolation theories and characterized by multiple local flow loops formed mainly by small-scale fractures. The water velocity distribution through a flow path was determined using discrete fracture network flow simulations, and solute transport was calculated using a previously derived impulse-response function and a particle-tracking scheme. Values for effective (or up-scaled) transport parameters were obtained by matching breakthrough curves from numerical experiments with an analytical solution for solute transport along a single fracture. Results indicate that a combination of local flow loops and the associated matrix diffusion process, together with scaling properties in flow path geometry, seems to be an important mechanism causing the observed scale dependence of the effective matrix diffusion coefficient (at a range of scales).

Diffusion↗

Observation of a broad 1-- resonant structure around 1.5 GeV/c2 in the K+K- mass spectrum in J/psi-->K+K-pi0.

A broad peak is observed at low K+K- invariant mass in J/psi-->K+K-pi(0) decays found in a sample of 5.8x10(7) J/psi events collected with the BESII detector. The statistical significance of the broad resonance is much larger than 5sigma. A partial wave analysis shows that the J;{PC} of this structure is 1--. Its pole position is determined to be [1576(-55)(+49)(stat)-91+98(syst)] MeV/c(2)-i/2[818(-23)(+22)(stat)-133+64(syst)] MeV/c(2). These parameters are not compatible with any known meson resonances.

Journal Article↗

Measurements of the branching fractions for psi(3770)-->D(0)D[over ](0), D+D-, DD[over ], and the resonance parameters of psi(3770) and psi(2S).

We measure the branching fractions for psi(3770)-->D(0)D[over ](0), D+D-, DD[over ], and non-DD[over ] to be (46.7+/-4.7+/-2.3)%, (36.9+/-3.7+/-2.8)%, (83.6+/-7.3+/-4.2)%, and (16.4+/-7.3+/-4.2)%, respectively. The resonance parameters of psi(3770) and psi(2S) are measured to be M_(psi(3770))=3772.2+/-0.7+/-0.3 MeV, Gamma_(psi(3770))(tot)=26.9+/-2.4+/-0.3 MeV, and Gamma_(psi(3770))(ee)=251+/-26+/-11 eV; M_(psi(2S))=3685.5+/-0.0+/-0.3 MeV, Gamma_(psi(2S))(tot)=331+/-58+/-2 keV, and Gamma_(psi(2S))(ee)=2.330+/-0.036+/-0.110 keV. We also measure the light hadron R value to be R(uds)=2.262+/-0.054+/-0.109 in the energy region from 3.660 to 3.872 GeV.

Journal Article↗

Observation of a near-threshold enhancement in the omega(phi) mass spectrum from the doubly OZI-suppressed decay J/psi-->gamma(omega)phi.

An enhancement near threshold is observed in the omega(phi) invariant mass spectrum from the doubly Okubo-Zweig-Iizuka-suppressed decays of J/psi-->gamma(omega)phi, based on a sample of 5.8 x 10(7) J/psi events collected with the BESII detector. A partial wave analysis shows that this enhancement favors JP=0+, and its mass and width are M=1812(+19)(-26)(stat)+/-18(syst) MeV/c2 and Gamma=105+/-20(stat)+/-28(syst) MeV/c2. The product branching fraction is determined to be B(J/psi-->gammaX)B(X-->omega(phi))=[2.61+/-0.27(stat)+/-0.65(syst)]x10(-4).

Journal Article↗

Observation of a resonance in Chi(1835) in J/psi --> gammapi+ pi- eta-.

The decay channel J/psi --> gamma(pi)(+)pi(-)eta is analyzed using a sample of 5.8 x 10(7) J/psi events collected with the BESII detector. A resonance, the Chi(1835), is observed in the pi(+)pi(-)eta invariant-mass spectrum with a statistical significance of 7.7 sigma. A fit with a Breit-Wigner function yields a mass M = 1833.7 +/- 6.1(stat) +/- 2.7(syst) MeV/c(2), a width Tau = 67.7 +/- 20.3(stat) +/- 7.7(syst) MeV/c(2), and a product branching fraction B(J/psi --> gammaChi) . B(Chi --> pi(+)pi(-)eta) = [2.2 +/- 0.4(stat) +/- 0.4(syst)] x 10(-4). The mass and width of the Chi(1835) are not compatible with any known meson resonance. Its properties are consistent with expectations for the state that produces the strong pp mass threshold enhancement observed in the J/psi --> gammapp process at BESII.

Journal Article↗

An active region model for capturing fractal flow patterns in unsaturated soils: model development.

Preferential flow commonly observed in unsaturated soils allows rapid movement of solute from the soil surface or vadose zone to the groundwater, bypassing a significant volume of unsaturated soil and increasing the risk of groundwater contamination. A variety of evidence indicates that complex preferential patterns observed from fields are fractals. In this study, we developed a relatively simple active region model to incorporate the fractal flow pattern into the continuum approach. In the model, the flow domain is divided into active and inactive regions. Flow occurs preferentially in the active region (characterized by fractals), and inactive region is simply bypassed. A new constitutive relationship (the portion of the active region as a function of saturation) was derived. The validity of the proposed model is demonstrated by the consistency between field observations and the new constitutive relationship.

Fractals↗

A triple-continuum approach for modeling flow and transport processes in fractured rock.

This paper presents a triple-continuum conceptual model for simulating flow and transport processes in fractured rock. Field data collected from the unsaturated zone of Yucca Mountain, a repository site of high-level nuclear waste, show a large number of small-scale fractures. The effect of these small fractures has not been considered in previous modeling investigations within the context of a continuum approach. A new triple-continuum model (consisting of matrix, small-fracture, and large-fracture continua) has been developed to investigate the effect of these small fractures. This paper derives the model formulation and discusses the basic triple-continuum behavior of flow and transport processes under different conditions, using both analytical solutions and numerical approaches. The simulation results from the site-scale model of the unsaturated zone of Yucca Mountain indicate that these small fractures may have an important effect on radionuclide transport within the mountain.

Geological Phenomena↗

Field investigation into unsaturated flow and transport in a fault: model analyses.

Results of a fault test performed in the unsaturated zone of Yucca Mountain, Nevada, were analyzed using a three-dimensional numerical model. The fault was explicitly represented as a discrete feature and the surrounding rock was treated as a dual-continuum (fracture-matrix) system. Model calibration against seepage and water-travel-velocity data suggests that lithophysal cavities connected to fractures can considerably enhance the effective fracture porosity and therefore retard water flow in fractures. Comparisons between simulation results and tracer concentration data also indicate that matrix diffusion is an important mechanism for solute transport in unsaturated fractured rock. We found that an increased fault-matrix and fracture-matrix interface areas were needed to match the observed tracer data, which is consistent with previous studies. The study results suggest that the current site-scale model for the unsaturated zone of Yucca Mountain may underestimate radionuclide transport time within the unsaturated zone, because an increased fracture-matrix interface area and the increased effective fracture porosity arising from lithophysal cavities are not considered in the current site-scale model.

Biological Transport↗

Assessment of geometrical accuracy of magnetic resonance images for radiation therapy of lung cancers.

The purpose of this research was to investigate the geometrical accuracy of magnetic resonance (MR) images used in the radiation therapy treatment planning for lung cancer. In this study, the capability of MR imaging to acquire dynamic two-dimensional images was explored to access the motion of lung tumors. Due to a number of factors, including the use of a large field-of-view for the thorax, MR images are particularly subject to geometrical distortions caused by the inhomogeneity and gradient nonlinearity of the magnetic field. To quantify such distortions, we constructed a phantom, which approximated the dimensions of the upper thorax and included two air cavities. Evenly spaced vials containing contrast agent could be held in three directions with their cross-sections in the coronal, sagittal, and axial planes, respectively, within the air cavities. MR images of the phantom were acquired using fast spin echo (FSE) and fast gradient echo (fGRE) sequences. The positions of the vials according to their centers of mass were measured from the MR images and registered to the corresponding computed tomography images for comparison. Results showed the fGRE sequence exhibited no errors >2.0 mm in the sagittal and coronal planes, whereas the FSE sequence produced images with errors between 2.0 and 4.0 mm along the phantom's perimeter in the axial plane. On the basis of these results, the fGRE sequence was considered to be clinically acceptable in acquiring images in all sagittal and coronal planes tested. However, the spatial accuracy in periphery of the axial FSE images exceeded the acceptable criteria for the acquisition parameters used in this study.

Computer Simulation↗

Electrokinetic injection techniques in microfluidic chips.

The separation efficiency of a microfluidic chip is influenced to a significant degree by the flow field conditions within the injection microchannel. Therefore, an understanding of the physics of the flow within this channel is beneficial in the design and operation of such a system. The configuration of an injection system is determined by the volume of the sample plug that is to be delivered to the separation process. Accordingly, this paper addresses the design and testing of injection systems with a variety of configurations, including a simple cross, a double-T, and a triple-T configuration. This paper also presents the design of a unique multi-T injection configuration. Each injection system cycles through a predetermined series of steps, in which the electric field magnitude and distribution within the various channels is strictly manipulated, to effectuate a virtual valve. The uniquemulti-T configuration injection system presented within this paper has the ability to simulate the functions of the cross, double-T, and triple-T systems through appropriate manipulations of the electric field within its various channels. In other words, the proposed design successfully combines several conventional injection systems within a single microfluidic chip.

Journal Article↗

An investigation of energy spectrum and lineal energy variations in mega-voltage photon beams used for radiotherapy.

Megavoltage photon beams are routinely used for external-beam radiotherapy. Recently, new treatment modalities based on dynamic and intensity modulated (IM), beam delivery systems are increasingly used in clinical practice. The purpose of this work is to investigate the energy spectrum and microdosimetric features of these photon beams. A Monte Carlo technique was first used to simulate beam lines of medical accelerators and to compute photon fluence and spectrum per unit dose-to-water inside the irradiated medium. Subsequently, a track structure code was used to compute the lineal energy and its distribution in a 1 micron sphere based on the individual photon spectrum. Results showed that the low energy photon component varied significantly with field size and location within the field due to the presence of the scattered photons. The calculated dose-mean lineal energy ranged from 2.3 keV.micron-1 at a depth of 1.5 cm along the central axis of a 4 cm x 4 cm field, to 3.7 keV.micron-1 at a depth of 20 cm of the field edge in a 10 cm x 10 cm field. In the tested IM fields at a depth of 10 cm, ranged from 2.6 to 3.5 keV.micron-1, which was inversely related to the dose intensity in the field. The values for the clinical photon beams were also significantly greater than that of a reference 60Co beam (1.8 keV.micron-1 from the calculation). The beam quality factor was estimated to vary within 20% due to the change of the energy spectrum for the radiotherapy photon fields.

Cobalt Radioisotopes↗

Pharmaceutical-induced cell apoptosis characterized by capillary zone electrophoresis.

Capillary zone electrophoresis (CZE) with a non-gel-sieving system was employed to characterize actinomycin D-induced cell apoptosis by measuring cellular DNA damage, termed DNA ladder, which proved to be thoroughly different from the DNA damage pattern of cell necrosis. The results by CZE analyses were identical to those obtained by conventional slab gel electrophoresis, demonstrating that CZE would be a reliable and more convenient technique for the identification of cell death with advantages of higher performance, high-speed, minute sample requirement, and advanced automation.

Animals↗

Binding and recognition of GATATC target sequences by the EcoRV restriction endonuclease: a study using fluorescent oligonucleotides and fluorescence polarization.

Oligonucleotides labeled with hexachlorofluorescein (hex) have enabled the interaction of the restriction endonuclease EcoRV with DNA to be evaluated using fluorescence anisotropy. The sensitivity of hex allowed measurements at oligonucleotide concentrations as low as 1 nM, enabling K(D) values in the low nanomolar range to be measured. Both direct titration, i.e., addition of increasing amounts of the endonuclease to hex-labeled oligonucleotides, and displacement titration, i.e., addition of unlabeled oligonucleotide to preformed hex-oligonucleotide/EcoRV endonuclease complexes, have been used for K(D) determination. Displacement titration is the method of choice; artifacts due to any direct interaction of the enzyme with the dye are eliminated, and higher fluorescent-labeled oligonucleotide concentrations may be used, improving signal-to-noise ratio. Using this approach (with three different oligonucleotides) we found that the EcoRV restriction endonuclease showed a preference of between 1.5 and 6.5 for its GATATC target sequence at pH 7.5 and 100 mM NaCl, when the divalent cation Ca2+ is absent. As expected, both the presence of Ca2+ and a decrease in pH value stimulated the binding of specific sequences but had much less effect on nonspecific ones.

Binding, Competitive↗

Incorporating dynamic collimator motion in Monte Carlo simulations: an application in modelling a dynamic wedge.

In radiation therapy, new treatment modalities employing dynamic collimation and intensity modulation increase the complexity of dose calculation because a new dimension, time, has to be incorporated into the traditional three-dimensional problem. In this work, we investigated two classes of sampling technique to incorporate dynamic collimator motion in Monte Carlo simulation. The methods were initially evaluated for modelling enhanced dynamic wedges (EDWs) from Varian accelerators (Varian Medical Systems, Palo Alto, USA). In the position-probability-sampling or PPS method, a cumulative probability distribution function (CPDF) was computed for the collimator position, which could then be sampled during simulations. In the static-component-simulation or SCS method, a dynamic field is approximated by multiple static fields in a step-shoot fashion. The weights of the particles or the number of particles simulated for each component field are computed from the probability distribution function (PDF) of the collimator position. The CPDF and PDF were computed from the segmented treatment tables (STTs) for the EDWs. An output correction factor had to be applied in this calculation to account for the backscattered radiation affecting monitor chamber readings. Comparison of the phase-space data from the PPS method (with the step-shoot motion) with those from the SCS method showed excellent agreement. The accuracy of the PPS method was further verified from the agreement between the measured and calculated dose distributions. Compared to the SCS method, the PPS method is more automated and efficient from an operational point of view. The principle of the PPS method can be extended to simulate other dynamic motions, and in particular, intensity-modulated beams using multileaf collimators.

Biophysical Phenomena↗

A method of simulating dynamic multileaf collimators using Monte Carlo techniques for intensity-modulated radiation therapy.

A method of modelling the dynamic motion of multileaf collimators (MLCs) for intensity-modulated radiation therapy (IMRT) was developed and implemented into the Monte Carlo simulation. The simulation of the dynamic MLCs (DMLCs) was based on randomizing leaf positions during a simulation so that the number of particle histories being simulated for each possible leaf position was proportional to the monitor units delivered to that position. This approach was incorporated into an EGS4 Monte Carlo program, and was evaluated in simulating the DMLCs for Varian accelerators (Varian Medical Systems, Palo Alto. CA, USA). The MU index of each segment, which was specified in the DMLC-control data, was used to compute the cumulative probability distribution function (CPDF) for the leaf positions. This CPDF was then used to sample the leaf positions during a real-time simulation, which allowed for either the step-shoot or sweeping-leaf motion in the beam delivery. Dose intensity maps for IMRT fields were computed using the above Monte Carlo method, with its accuracy verified by film measurements. The DMLC simulation improved the operational efficiency by eliminating the need to simulate multiple segments individually. More importantly, the dynamic motion of the leaves could be simulated more faithfully by using the above leaf-position sampling technique in the Monte Carlo simulation.

Biophysical Phenomena↗

Verification of tangential breast treatment dose calculations in a commercial 3D treatment planning system.

The accuracy of the photon convolution/superposition dose algorithm employed in a commercial radiation treatment planning system was evaluated for conditions simulating tangential breast treatment. A breast phantom was fabricated from machineable wax and placed on the chest wall of an anthropomorphic phantom. Radiographic film was used to measure the dose distribution at the axial midplane of the breast phantom. Subsequently, thermoluminescent dosimeters (TLDs) were used to measure the dose at four points within the midplane to validate the accuracy of the film dosimetry. Film measurements were compared with calculations performed using the treatment planning system for four types of treatment: optimized wedged beams at 6 and 18 MV and two-dimensional compensated beams at 6 and 18 MV. Both the film- and TLD-measured doses had a precision of approximately 0.6%. The film-measured doses were approximately 1.5% lower than the TLD-measured doses, ranging from 0-3% at 6 MV and 0.5-1% at 18 MV. Such results placed a high level of confidence in the accuracy and precision of the film data. The measured and calculated doses agreed to within +/-3% for both the film and TLD measurements throughout the midplane exclusive of areas not having charged particle equilibrium. Good agreement was not expected within these regions due to the limitations in both film dosimetry and the dose-calculation algorithm. These results indicated that the treatment planning system calculates doses at the midplane with clinically acceptable accuracy in conditions simulating tangential breast treatment.

Algorithms↗