Search PubMed⌕ Search

Biomedical subjects

H H Hilger

Publications and source records attributed to H H Hilger.

At least 37 records · Page 2Linked to original sources

Reproducibility of assessment of left-ventricular function using intraoperative transesophageal echocardiography.

Reproducibility of results is an important point in assessing the utility of intraoperative transesophageal echocardiography for evaluating changes in left-ventricular function. The purpose of the present study was to define the intra- and interobserver reproducibility of the qualitative assessment of left-ventricular regional wall motion and the quantitative assessment of global left-ventricular function. In addition, the interstudy reproducibility of two examinations was tested when the probe was displaced and replaced in the esophagus. A transesophageal short-axis view at the level of the papillary muscles was obtained in 86 patients undergoing cardiac surgery. In the 80 patients with adequate images, regional wall motion was visually graded and area ejection fraction was calculated by two observers and assessment was repeated by the same observer one day later. The same observer graded wall motion differently in only 5% (24/480) of segments. Grading by two observers differed in 9% (43/480) of segments. Assessment differed by one grade at the most and in not more than 2 out of 6 segments per patient. Repeated measurements of area ejection fraction (AEF) by the same observer correlated well (r = 0.97 before and r = 0.97 after cardiopulmonary bypass) with a mean percent difference of 6%. A similarly close correlation was found for measurements of two observers (r = 0.90 and r = 0.93, respectively) with a mean percent difference of 10% for area ejection fraction. The correlation for the first and second examination in the same patient by one observer was acceptable (r = 0.78 and r = 0.80, respectively) with a mean percent difference of 15% for area ejection fraction.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[Dobutamine versus dipyridamole magnetic resonance tomography: safety and sensitivity in the detection of coronary stenoses].

Safety and sensitivity of gradient-echo magnetic resonance imaging (MRI) for the identification of significant coronary artery stenoses using pharmacologic stress testing was assessed in 61 patients with > or = 70% stenosis of a major coronary artery and a normal left ventricle. After MRI at rest 28 patients underwent dobutamine-MRI during steady-state dobutamine infusion (5, 10, 15 and 20 micrograms/kg/min) and 33 patients had dipyridamole-MRI after high-dose dipyridamole infusion (0.75 mg/kg over 10 min). All patients additionally performed standard ECG exercise stress testing (EST). Segmental wall motion analysis was performed in basal and midventricular short axis tomograms by two observers. A segment was graded pathologic if transient dobutamine or dipyridamole induced wall motion abnormalities could be detected. For comparison to coronary angiography findings, each segment was assigned to one of the coronary artery perfusion territories. There were no serious side-effects during dobutamine and dipyridamole infusion leading to termination of the study protocol. Peak double product during dobutamine infusion was significantly higher (p < 0.001) than after dipyridamole infusion (18.493 +/- 4.311 versus 12.799 +/- 2.694 mm Hg/min). Overall sensitivity of dobutamine and dipyridamole-MRI for coronary artery disease (CAD) was 85% and 84%. Regional asynergy by dobutamine and dipyridamole-MRI was observed in 73% versus 79% patients with single- and 100% versus 92% with multi-vessel disease. Individual coronary artery stenoses were correctly identified by segmental wall motion abnormalities in 87% versus 81% for left anterior descending, 62% versus 86% for left circumflex and 78% versus 92% for right coronary artery stenoses. In conclusion, dobutamine and dipyridamole-MRI are well tolerated and safe non-exercise dependent tests for detection and localization of hemodynamically significant coronary artery stenoses with a similar diagnostic accuracy but with a better control of stress intensity and duration provided by dobutamine.

Adult↗

[Clinical experiences with four newly developed, surface modified stimulation electrodes].

Newly developed pacing electrodes with so-called porous surfaces promise a significantly improved post-operative pacing and sensing threshold. We therefore investigated four newly developed leads (ELA-PMCF-860 n = 10; Biotronik-60/4-DNP n = 10, CPI-4010 n = 10, Intermedics-421-03-Biopore n = 6) connected to two different pacing devices (Intermedics NOVA II, Medtronic PASYS) in 36 patients (18 men, 18 women, age: 69.7 +/- 9.8 years) suffering from symptomatic bradycardia. The individual electrode maturation process was investigated by means of repeated measurements of pacing threshold, electrode impedance in acute, subacute, and chronic phase, as well as energy consumption and sensing behavior in the chronic phase. However, with the exception of the 4010, the investigated leads showed largely varying values of the pacing threshold with individual peaks occurring from the second up to the 13th week. All leads had nearly similar chronic pacing thresholds (PMCF 0.13 +/- 0.07; DNP 0.25 +/- 0.18; Biopore 0.15 +/- 0.05; 4010 0.14 +/- 0.05 ms). Impedance measurements revealed higher, but not significantly different values for the DNP (PMCF 582 +/- 112, DNP 755 +/- 88, Biopore 650 +/- 15, 4010 718 +/- 104 Ohm). Despite differing values for pacing threshold and impedance, the energy consumption in the chronic phase during threshold-adapted, but secure stimulation (3 * impulse-width at pacing threshold) were comparable.

Aged↗

[Effect of a single blood donation on ergo-spirometrically determined cardiopulmonary performance capacity of young healthy probands].

Autologous blood donation is an established method for an effective reduction of the blood-transfusion-associated infectious diseases (hepatitis, HIV infections, etc.) in elective surgical procedures. The aim of the study was to investigate the effects of a blood donation of 450 ml on the cardiopulmonary exercise capacity in 16 apparently healthy young subjects. The 24 cardiopulmonary exercise tests were performed on a bicycle ergometer (Ergoline 900) in a semisupine position, using a ramp program (+20 watt/min) 1-7 days before and 2 days after blood donation. By means of continuous breath-by-breath measurements of the gas exchange (VO2, VCO2) and ventilation parameters (minute ventilation VE), as well as of the routine parameters (heart rate, blood pressure, work rate) during incremental exercise the respiratory anaerobic threshold VO2AT, the maximum VO2 (VO2max and the maximal working capacity (max. WR) were determined. Serum hemoglobin concentration was significantly (p < 0.0005) reduced from 14.5 +/- 1.0 to 13.0 +/- 1.4 g/dl after blood donation. The ventilatory anaerobic threshold (before: 68.5 +/- 17.0; after: 52.0 +/- 20.3% pred. max. VO2), the max. VO2 (before: 124.2 +/- 21.3; after: 110.2 +/- 23.2% pred. max. VO2) and max. WR (before: 287.1 +/- 75.6; after 265.5 +/- 76.2 watt) fell significantly (VO2AT: p < 0.0005; max. VO2: p < 0.0005; max. WR: p < 0.025). Heart rate and minute ventilation showed a steeper increase (dHR/dWR: before: 0.31 +/- 0.06; after: 0.34 +/- 0.05 beats/min/watt; dVE/dWR: before: 0.29 +/- 0.05; after: 0.31 +/- 0.05 l/watt) in relation to the increase in WR after blood donation as compared to the test before.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[Local vascular complications in heart catheter studies].

Over a period of 30 months (1. 1. 89-30. 6. 91) 3516 patients who had either a diagnostic (2718) or therapeutic (798) heart catheterization were followed for local vascular complications. 774 patients were investigated prospectively. The following complications were observed in declining frequency: 1. relevant haematoma, 2. pseudoaneurysm, 3. arteriovenous fistula, 4. arterial thrombosis/dissection, 5. venous thrombosis, 6. rupture of the vessel, 7. local infection. The total complication rate was 2.22%. With prospective investigation it was significantly higher (3.23%) than with retrospective investigation (1.93%). The complication rate was also significantly higher in therapeutical procedures (3.76%) than in diagnostic catheterizations (1.76%). Factors associated with a significantly higher incidence of local vascular complications were age (p < 0.01), female gender (p < 0.025), manifest arterial hypertension (p < 0.005), aortic regurgitation (p < 0.1), peri-interventional medication with acetylsalicylic acid and full dose heparin (p < 0.001), full dose heparin alone (p < 0.001) or fibrinolysis-therapy (p < 0.025). Relevant technical factors were: duration of the procedure, duration of the placement of the catheter-sheath, French size of the catheter, left femoral access, arterial and venous access at one extremity. In about half of the cases the treatment of the complications was conservative, in the other half it was surgical (51%). In relation to all surgically treated patients the percentage of emergency operations was 25%, the percentage of reoperations was 15%.

Adult↗

[Multicenter results of coronary implantation of balloon expandable Palmaz-Schatz vascular stents].

Intracoronary stenting was designed to handle acute vessel closure after balloon angioplasty and to reduce the rate of restenosis. In three cardiology centers the implantation of 200 balloon-expandable Palmaz-Schatz stents was attempted in 179 patients. The implantation was successful in 170 patients (95%). During bail-out implantation for acute vessel closure or symptomatic dissections after balloon angioplasty, implantation succeeded in 60 (91%) of 66 attempted patients, who recovered immediately from ischemia. Three patients received emergency bypass surgery and three patients were kept on medical therapy. Restenosis after 4 to 6 months, defined as > 50% diameter reduction, was documented angiographically in 18 (15.3%) of 118 presently controlled patients. Patients with single stent implantation (n = 106) presented a late restenosis rate of 10.4% in contrast to patients with multiple stent implantation (n = 12), who presented a restenosis rate of 58.4%. Similar results on restenosis were found for patients with elective and bail-out stent implantation. Acute thrombotic stent occlusion occurred in three patients (1.8%) during the first 24 h after stenting. Three to 9 days after implantation subacute stent thrombosis occurred in 15 (8.8%) of 170 patients. Despite adequate therapy including thrombolysis, balloon angioplasty or emergency bypass surgery in 14 of 15 patients Q-wave myocardial infarction was documented in six patients and non Q-wave myocardial infarction in five patients. The following parameters were identified as risk factors for the development of subacute stent thrombosis: bail-out indication, unstable angina, type C lesion, stenosis length > 1.5 cm, plaque area > 3.5 mm2, symptomatic dissection after balloon angioplasty, incomplete wrapping of the dissection after stenting and residual distal vessel irregularities after stenting. Bleeding complications occurred in 12.4% of the patients and were related to the anticoagulation and antiaggregation therapy. In conclusion, the implantation of Palmaz-Schatz stents is an excellent bail-out device to treat acute vessel closure or symptomatic dissections after angioplasty. Elective and bail-out single stent implantation is associated with a reduced rate of restenosis when compared to conventional balloon angioplasty. At present, subacute stent thrombosis and bleeding complications are the major limitations with a combined rate of 15.9%.

Adult↗

Feasibility of high-dose dipyridamole-magnetic resonance imaging for detection of coronary artery disease and comparison with coronary angiography.

To assess the feasibility, safety and usefulness of gradient-echo magnetic resonance imaging (MRI) combined with pharmacologic stress testing for the detection of coronary artery disease, 23 patients without previous myocardial infarction but with significant stenosis (greater than 70% diameter stenosis) of greater than or equal to 1 major coronary artery were selected for dipyridamole-MRI stress testing. Each patient underwent MRI at rest, and high-dose dipyridamole-MRI (0.75 mg/kg over 10 minutes) of corresponding basal and midventricular short-axis tomograms. Additionally, these patients performed symptom-limited exercise stress tests. All short-axis tomograms were evaluated on a standardized segmental basis by grading each segment as normal, hypokinetic, akinetic or dyskinetic. Dipyridamole-MRI was considered pathologic if segmental wall motion deteriorated by greater than or equal to 1 grade after dipyridamole. For comparison with coronary angiography, segmental wall motion gradings were related to the respective coronary artery territories in the short-axis plane. Pathologic dipyridamole-MRI was obtained in 18 of 23 (78%) patients. For 1- and 2-vessel diseases, sensitivity was 69 and 90%, respectively. Exercise stress tests were pathologic in 14 of 23 (66%) patients. For 1- and 2-vessel diseases, sensitivity of exercise stress test was 58% (7 of 12 patients) and 77% (7 of 9), respectively. Sensitivity/specificity of dipyridamole-MRI for the localization of the stenosed coronary artery was 78/100% for left anterior descending, 73/100% for left circumflex, and 88/87% for right coronary artery stenoses. It is concluded that dipyridamole-MRI is a feasible nonexercise-dependent test for detection and localization of functionally significant coronary artery disease.

Aged↗

Cardiac involvement during and after malaria.

In 22 patients without a previous history of cardiac disease, we prospectively evaluated cardiac involvement during acute malaria and 9 +/- 5 months after recovery using non-invasive methods including resting electrocardiogram (ECG) and two-dimensional (2D) echocardiography. During the acute phase ECG abnormalities were common (5/22); pericardial effusion was found in 2 patients and global left ventricular hypokinesia in 1 patient infected with Plasmodium falciparum. At a follow-up of 19 patients, the resting ECG and echocardiography were normal or had normalized in all patients. The results of our study suggest that persistent cardiac damage following malarial infection seems to be rare; however, further trials in a larger patient population are needed to confirm our findings.

Adolescent↗

Chronic myocardial infarction: assessment of morphology, function, and perfusion by gradient echo magnetic resonance imaging and 99mTc-methoxyisobutyl-isonitrile SPECT.

To assess the ability of magnetic resonance imaging (MRI) to identify the anatomic and functional abnormalities associated with completely scarred myocardium, 20 patients with chronic transmural myocardial infarction confirmed by electrocardiography and cineventriculography were examined by gradient echo MRI. Myocardial perfusion at rest was assessed in corresponding transverse sections using 99mTc-methoxyisobutyl-isonitrile single-photon emission computed tomography (MIBI-SPECT). MRI scar was defined as diastolic wall thickness (DWT) 2.5 SD below corresponding normal values or systolic wall thickening (delta WT) less than or equal to 1 mm. For MIBI-SPECT images, scar was defined as a MIBI uptake less than 2.5 SD below normal values. By MIBI-SPECT, 152 segments contained normal tissue and 88 contained scarred myocardium. In 226 of 240 (94%) segments, MRI gradings by DWT and MIBI-SPECT gradings were identical. DWT by MRI was higher in normal than in scarred MIBI-SPECT segments (10 +/- 1 versus 4 +/- 2 mm, p less than 0.001). In 230 of 240 (96%) segments, MRI gradings by delta WT and MIBI-SPECT gradings were identical. Segments graded normal by MIBI-SPECT showed higher delta WT by MRI than scar segments (5 +/- 1 versus 0.3 +/- 1 mm, p less than 0.001). MIBI-SPECT perfusion defect size and regions with reduced DWT on MRI tomograms correlated well (r = 0.85). This study indicates that myocardial regions fulfilling electrocardiographic and ventriculographic criteria for transmural myocardial scar are clearly depicted by regional diastolic wall thinning and delta WT less than or equal to 1 mm on gradient echo MR images.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Regurgitant flow in cardiac valve prostheses: diagnostic value of gradient echo nuclear magnetic resonance imaging in reference to transesophageal two-dimensional color Doppler echocardiography.

Gradient echo nuclear magnetic resonance (NMR) imaging and transesophageal two-dimensional color Doppler echocardiography are flow-sensitive techniques that have been used in the diagnosis and grading of valvular regurgitation. To define the diagnostic value of gradient echo NMR imaging in the detection of regurgitant flow in cardiac valve prostheses and the differentiation of physiologic leakage flow from pathologic transvalvular or paravalvular leakage flow, 47 patients with 55 valve prostheses were examined. Color Doppler transesophageal echocardiography was used for comparison. Surgical confirmation of findings was obtained in 11 patients with 13 valve prostheses. Gradient echo NMR imaging showed regurgitant flow in 37 of 43 valves with a jet seen on transesophageal echocardiography and it detected physiologic leakage flow in 4 additional valves. There was 96% agreement between the two methods in distinguishing between physiologic and pathologic leakage flow. The methods differed on jet origin of pathologic leakage flow in six prostheses. The degree of regurgitation was graded by both NMR imaging and transesophageal echocardiography, according to the area of the regurgitant jet visualized; gradings were identical for 75% of valve prostheses. Quantification of jet length and area showed a good correlation between the two methods (r = 0.85 and r = 0.91, respectively). Gradient echo NMR imaging is a useful noninvasive technique for the detection, localization and estimation of regurgitant flow in cardiac valve prostheses. However, because transesophageal echocardiography is less time-consuming and less expensive, gradient echo NMR imaging is unlikely to displace transesophageal echocardiography and should be used only in the occasional patient who cannot be adequately imaged by echocardiography.

Coronary Circulation↗

A prospective study on percutaneous coronary angioscopy with different guiding techniques in patients with coronary heart disease.

The technical success of percutaneous coronary angioscopy using different guiding techniques was evaluated in 17 patients before (n = 17) and after (n = 8) coronary angioplasty. Steering the angioscope along or over a guidewire was successful in both groups; failures were predominantly due to insufficient alignment of the angioscope using along-the-wire guiding. Although over-the-wire angioscopy promises superior guiding and alignment capabilities, several technical problems remain unsolved.

Adult↗

Left ventricular thrombi: evaluation with spin-echo and gradient-echo MR imaging.

Gradient-echo (GRE) and spin-echo (SE) magnetic resonance (MR) imaging was performed in 31 patients with chronic left ventricular (LV) thrombi. Thrombi were confirmed or excluded at surgery or by means of other corroborative diagnostic techniques. MR images were evaluated by three reviewers without knowledge of results of corroborative studies. Diagnoses were graded unequivocal if agreed on by three observers and probable if agreed on by two observers. With SE imaging, 12 of 18 confirmed thrombi were detected unequivocally, five were considered probable, and one was not detected. With GRE imaging, 16 of the 18 thrombi were visualized unequivocally; two were considered probable. With SE technique, thrombus was unequivocally excluded in nine of 13 cases and exclusion was considered probable in four. One finding was false-negative. Exclusion of thrombus with GRE imaging was unequivocal in 10 of 13 cases and probable in two, and one finding of thrombus was false-positive. GRE imaging resulted in improved differentiation of thrombi from the surrounding blood pool and myocardium and thus was diagnostically superior to SE imaging in detection of LV thrombi.

Adult↗

Reversible volume changes of trapped gas in nonspecific bronchoprovocation tests.

Thirty patients with a history of asthma and ten patients with suspected bronchial hyperreactivity underwent nonspecific provocation testing. The control group consisted of ten normal volunteers without a history of lung disease. The patients' baseline FEV1 (percent predicted) revealed mild obstructive disease (72.9 +/- 8.9 percent and 74.6 +/- 7.7 percent) compared with controls (87.2 +/- 8.5 percent, p less than 0.001). The mean volume of trapped gas (D) (ie, TLCB-TLCHe) was not significantly different between groups (0.11 +/- 0.49 L vs 0.15 +/- 0.4 L vs 0.18 +/- 0.45 L), and no correlation was established with any of the remaining lung function data. Bronchial hyperreactivity in response to inhaling acetylcholine could be observed in the asthma group only. Their mean D increased significantly from 0.11 +/- 0.49 L to 0.62 +/- 0.66 L (p less than 0.001), and returned to baseline (0.26 +/- 0.55, NS) subsequent to inhaling salbutamol. D changes induced by acetylcholine correlated weakly with concurrent changes of FEV1 (r = -0.44, p = 0.01), RV (r = 0.59, p less than 0.001), and Rs (r = 0.59, p less than 0.001). In response to bronchodilating doses of salbutamol, however, D was changed in close correlation with FEV1 (r = -0.82, p less than 0.0001), RV (r = 0.85, p less than 0.0001), and Rs (r = 0.76, p less than 0.0001). Provided that D is a valid parameter of small airways function, these data may give a clue to the site of action of both drugs. Acetylcholine affects small and large airways alike with no clear-cut preference, whereas salbutamol's predominant target appears to be the small airways. These conclusions are only partially supported by the pertinent literature.

Acetylcholine↗

[Transesophageal echography in staging of bronchial cancers].

The kind of relation of central lung cancer (c) to the walls of the central pulmonary arteries (PA) and the aorta is an important information prior to operative or interventional (laser/afterloading) therapy. As computed tomography (CT) and angiography are often inaccurate in the assessment of PA-infiltration, we assessed the diagnostic value of transesophageal echography (TEE) in the staging of LC. 16 patients (pts.) were investigated using TEE in addition to CT or magnetic resonance imaging (MRI). Eleven pts. had central LC, 3 peripheral LC, 1 anterior mediastinal mass and 1 central pneumonia (cancer excluded). 2 pts. with central LC were unable to swallow the probe. In 9/9 pts. with central LC, 1/3 pts. with peripheral LC and 1 pt. with enlarged anterior mediastinum the tumour mass could be visualized. In the pt. with a centrally located infiltrate on chest radiogram TEE demonstrated enlarged hilar lymph nodes, but excluded a central tumour. Main PA branches could be identified in all 14/14 pts. Central left or right PA were compressed slightly in 3 pts. and severely in 2 pts., with a near total occlusion in one (confirmed by MRI/CT). TEE revealed PA-infiltration in 2 pts. and aortic wall infiltration in 2 other pts. Despite adjacent tumour mass aortic wall infiltration was excluded in 2 pts. Enlarged hilar lymph nodes could be demonstrated in 2/9 pts. with central LC, whereas CT/MRI showed enlarged mediastinal lymph nodes in 7/9 pts. In conclusion, TEE is able to visualize central lung cancer and gives useful additional informations about the kind of relation to central PA and the aorta.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

[Magnetic resonance tomography image of transmural myocardial infarct in comparison with 99mTc-methoxyisobutylisonitrile SPECT].

To assess the ability of magnetic resonance imaging (MRI) to identify morphologic and functional abnormalities associated with transmural anterior and inferior myocardial infarction, 18 patients with anterior myocardial infarcts and 11 patients with inferior myocardial infarcts confirmed by ECG and cine-ventriculography underwent gradient-echo MRI of transverse and short-axis imaging planes. Myocardial perfusion of corresponding imaging planes was measured by 99mTc-methoxyisobutyl-isonitrile single-photon emission computed tomography (MIBI-SPECT). Transmural scar by MRI was defined as diastolic wall thickness 2.5 SD below corresponding normal values of a healthy control group (n = 21). MIBI-SPECT scar was defined as a MIBI uptake less than 2.5 SD below mean values of a healthy control group (n = 11). By MIBI-SPECT, 231 segments contained normal tissue and 161 contained scarred myocardium. In 352/392 (90%) segments gradings based on diastolic wall thickness and MIBI-SPECT gradings were identical. Diastolic wall thickness was significantly higher in normal than in scarred MIBI-SPECT segments (10.3 +/- 1.5 vs 5.2 +/- 2 mm, p less than 0.0001). Additionally, normal segments by MIBI-SPECT showed significantly higher systolic wall thickening than scar segments (5.5 +/- 1.5 vs 0.6 +/- 1.6 mm, p less than 0.0001). The correlation between MRI and MIBI-SPECT assessed infarct size was r = 0.91 for anterior and r = 0.77 for inferior myocardial infarcts. The agreement between MIBI-SPECT perfusion defect size and regions with reduced diastolic wall thickness on MRI tomograms was significantly better for anterior myocardial infarcts than for inferior myocardial infarcts.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[Effort-induced myocardial wall motion abnormalities in the magnetic resonance tomogram: a comparison with effort MIBI SPECT].

In 20 patients with an angiographically documented coronary artery stenosis of > or = 70% and normal LV function at rest MRI was performed before and after dipyridamole infusion (0.75 mg/kg BW). In all patients MIBI-SPECT was obtained at rest and after dynamic symptom-limited exercise. In 18 patients MIBI-SPECT showed ischemia and in 18 patients dipyridamole MRI showed a wall motion impairment. In the segments representing the 29 stenosed vessels ischemia in MIBI-SPECT was diagnosed correctly in 24 instances (sensitivity 83%, specificity 90%) and a wall motion abnormality was present in MRI in 23 instances (sensitivity 79%, specificity 90%). Dipyridamole GE-MRI is not superior to MIBI-SPECT in the diagnosis of ischemia.

Aged↗

[Pulmonary function tests after pneumocystis carinii pneumonia in HIV infected patients].

UNLABELLED: Significant impairment of lung volumes and gas exchange in HIV-infected patients with acute Pneumocystis carinii pneumonia (PCP) has been reported, whereas little is known about lung function compromise following successful therapy. In 9 patients with acute PCP and 9 patients 1-5 month after PCP lung function testing including spirometry, diffusing capacity for carbon monoxide and exercise blood gas analysis were performed serially at monthly intervals. The results were summarized in a total score. The mean period of follow-up for each patient was 7.2 +/- 2 months. A decrease in lung volumes (FEV1 67 +/- 14.2% pred.norm., VC 72.7 +/- 11.9% pred.norm.) and gas exchange (CO-transfer factor 53.2 +/- 18.5% pred.norm., CO-transfer coefficient 67.8 +/- 14.2 pred. norm.) was observed in all 9 patients with acute PCP. Post-PCP lung volumes normalized within 1 month, whereas disorders in gas exchange persisted for 1-3 months. The total score normalized in 16/18 patients. One of the remaining patients with persisting functional impairment had chronic obstructive airway disease, whereas in the other dysfunction was even observed prior to PCP and no diagnosis could be obtained. 2-6 months following acute disease a second period of decreased lung function occurred in 6 pts. In 3 of the 6 there were no clinical signs of infection (rebronchoscopy refused), in 1 patient infection with cytomegalovirus was suspected. In the other 2 patients a relapse of PCP was diagnosed by bronchoscopy. CONCLUSIONS: Acute PCP compromises lung mechanics and gas exchange. During recovery deficits in gas exchange persist longer than diminished lung volumes.(ABSTRACT TRUNCATED AT 250 WORDS)

Follow-Up Studies↗