Publications and source records attributed to H H Beneken Kolmer.

6 recordsLinked to original sources

A system model for closed-circuit inhalation anesthesia. II. Clinical validation.

Recently, we described a basic model and its more elaborate variants to predict the uptake and distribution of inhalational anesthetics during closed-circuit anesthesia. As an initial clinical validation of the linear, continuous, 14-compartment basic model, the current study examined its predictive performance in 50 patients by comparing quantitatively the predicted and the measured alveolar concentration-time profiles after bolus injections of liquid isoflurane into the closed system during mechanical ventilation. The two versions of the model studied differed in the size of their peripheral shunt, as 0% (version A) and 16% (version B) of the cardiac output. A total of 15,744 alveolar concentrations of isoflurane (one per 10s period) were measured by mass spectrometry. For each measured concentration we used computer simulations of version A and version B to calculate a predicted concentration for both versions. For each patient we calculated the bias (indicating over- or underprediction) and the scatter of the prediction errors (indicating the typical error size). The bias and the scatter of the prediction errors, both given as mean (and standard deviation), were 2.25 (13.59) and 12.51 (5.84)% for version A and 12.00 (14.97) and 14.12 (6.54)% for B. Version A performed better than B: both the bias (P = 0.008) and the scatter (P less than 0.0001) were closer to zero for A. Logistic regression analysis showed for version A that scatter, but not bias, increased with age (P = 0.002). Gender, body mass index (weight x height-2), and number of injections per hour did not influence scatter or bias.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

A system model for closed-circuit inhalation anesthesia. I. Computer study.

Developing a custom computer program to simulate the uptake, distribution, and elimination of inhalational anesthetics allows the anesthesiologist to address specific problems, but extensive skills are required to translate the involved processes first into a set of mathematical equations and then into a satisfactory computer program. The first step is often facilitated by solutions offered in the literature. The second step demands computer proficiency that is often not available, but this problem can be obviated by means of a special-purpose simulation language (SPSL). We therefore constructed a model for closed-circuit inhalation anesthesia with the aid of the block-structured SPSL TUTSIM. Noticeable differences with previous models are that the linear, 14-compartment basic model does not assume a constant alveolar concentration and mimics circulation times through the use of blood pools. Advanced features of the SPSL were used to develop variants of the basic model to simulate feedback-controlled isoflurane administration, nitrous oxide uptake, and the impact of a nonlinearity by incorporating the effect of enflurane on cardiac output. Two variants were concatenated to form a multiple model showing the concentration and second-gas effects. The model was capable of reproducing the anesthetic uptake from previous experimental studies for nitrous oxide. After its validation for other anesthetic agents, the model can be used for clinical, teaching, and research purposes. The SPSL freed the authors from the problems associated with computer programming and allowed them to concentrate on the structure of the model.

Anesthesia, Closed-Circuit↗

Evaluation of long sampling tubes for remote monitoring by mass spectrometry.

The long sampling tubes required for remote mass spectrometry alter the sampling system's performance characterized by sample flow, residence time, and 10 to 90% response time. We searched for an easy-to-handle tube with (1) a length of 30 m, (2) sample flow less than 50 ml.min-1, and (3) residence and response times approaching those predicted by our mathematical model. We tested tubes of various geometries and various commercially available materials by using them as inlet catheters for a quadrupole mass spectrometer (Centronic 200 MGA, Centronic Ltd, Craydon, UK). We measured their responses at 0 to 10% (on transients) and 10 to 0% (off transients) step changes in gas concentration for nitrogen, argon, nitrous oxide, oxygen, and carbon dioxide and 0 to 3% and 3 to 0% for halothane, enflurane, and isoflurane. With 5 polyethylene tubes, halothane response times were up to 38 times longer than predicted. One 30-m polyethylene tube combined a 158-ms response time for nitrogen and argon with a 2,205-ms response time for halothane. Teflon, polyvinyl chloride, and stainless steel also proved to be unsuitable because of unacceptable signal distortion: the carbon dioxide response time for a 30-m Teflon tube was 2,600 ms. A glass tube showed the least signal distortion but was hard to handle. Our requirements were fulfilled by a 29.77-m tube made from nylon with a 1.00-mm inside diameter to which a 0.23-m length of nylon with a 0.25-mm inside diameter was added at the patient end. It offers (1) sample flow equals 46 ml.min-1, (2) residence time equals 11.1 seconds, and (3) response times approaching our theoretical predictions, that is, 159, 164, 180, 159, 188, 302, 298, and 300 ms (means of on and off transients) for nitrogen, argon, nitrous oxide, oxygen, carbon dioxide, halothane, enflurane, and isoflurane, respectively. This tube allows the accurate monitoring of breathing frequencies up to 25 and 50 breaths/min for volatile agents and gases, respectively.

Anesthetics↗

The influence of tube geometry on the performance of long sampling tubes in respiratory mass spectrometry.

Long sampling tubes allow remote patient monitoring by mass spectrometry. The choice of adequate tube geometry and material, which may minimise signal distortion and signal transmission delay, needs quantification of the relations between tube dimensions and factors determining tube performance (sample flow, residence time, response time). A mathematical model is presented which considers ideal tubes (no gas-tube interaction) with various geometries. It is shown for tubes with length L and uniform radius r that the response time for nitrogen estimated by the expression 0.0046 L will differ less than 10% from the exact value if L/r3 less than 1.5 X 10(12). The limited number of commercially available radii prevents free choice of sample flow for uniform tubes of a given length. However, tubes consisting of two parts with different diameters can provide any desired sample flow. The model indicates that residence and response times are effectively reduced if optimum radii are used for these two parts, and that a tube with an exponentially rising radius as a function of distance may halve residence and response times, compared with a uniform tube providing identical sample flow. Model predictions can be used to judge experimental results obtained with real tubes made of various materials. Experimental data in corroboration of the model are presented.

Anesthesiology↗