[Gravity drainage versus suction drainage: an experimental and clinical study].

The importance of wound drainage in casualty and plastic surgery is unquestioned. The most common form is suction drainage. This involves the disadvantage that the drain can become attached to the tissue by suction, stopping the flow and blocking the drain. In addition, the secretion reservoir must be made of rigid material, which means large package sizes are inevitable. Encouraged by our knowledge of silicone drains, we carried out a study comparing silicone drains (without vacuum) and PVC drains (with vacuum suction). Electron-microscope studies of the PVC drains used for suction drainage revealed adhesion of wound secretion and cell detritus to the inner wall and the drainage perforations after less than 24 h. No occlusion and almost no adherence was observed with silicone gravity drains. When compared in clinical use for joint drainage, neither system had any severe complications. Removal of gravity drains was considerably less painful than withdrawal of suction drains. In soft tissue drainage the volume of secretion drained off was more constant and obviously larger with gravity drainage. From these results we conclude that gravity drainage can replace suction drainage to considerable advantage.

Clinical Trials as Topic↗

[Meniscus sonography--alternative to invasive meniscus diagnosis?].

Sonographic visualization of the meniscus as well as the detection and evaluation of its lesions presupposes use of the 7.5 MHz transducer of a sector scan. All lesions applied by means of a scalpel to cadaver knees could be pictured and evaluated in this way. In a clinical study, there was agreement between sonographic and surgical findings in 86 out of 91 patients (94%). The arthrography carried out in addition in 50 of these patients had a lower precision (88%) than sonography (98%). Agreement between the results of sonography and arthrography was found in 87 out of 98 patients (89%). The complete freedom from risk and high precision support the application of sonography in diagnosis of meniscus lesions. It can thus replace arthrography in this indication.

Arthrography↗

[Sonography of the meniscus and its lesions].

It is the considered opinion of the authors that meniscus sonography can largely replace arthrography. This opinion is based on their detailed examinations and studies. Sonographic visualisation of all lesions produced by a scalpel was demonstrated using knees of corpses. Even cracks having the fineness of a human hair were visualised by sonography. A comparison between sonographic and surgical findings in meniscus lesion yielded in 82 patients an agreement of 95.1%. In 47 patients it was possible to prove that sonography was more accurate than arthrography as far as diagnosis was concerned. A comparison of 94 sonographically and arthrographically established findings yielded agreement in 89% of the cases. Sonography is suitable for meniscus imaging especially on account of the good imaging reproducibility of meniscus morphology; through safe detection of a pathological process in the meniscus; through the safe presentation of lesions; through the accurate imaging of all parts of the meniscus; and, furthermore, through the invaluable advantage of noninvasiveness, freedom from pain and hazards; and, last but not least, rapid manipulation and unlimited repeatability.

Arthrography↗

[Measuring compartment pressure of the lower leg with a microtip probe].

In the acute compartment syndrome it is difficult to decide on the basis of clinical criteria alone whether or not fasciotomy is indicated. Reliable and objective parameters are required before a treatment schedule can be devised. Measurement of the pressure inside the acute compartment can facilitate the decision as to whether operative treatment is appropriate in the case of the muscular compartment involved. We performed compartment pressure measurements in the tibialis anterior compartment in 27 healthy volunteers using a microtip probe. Clinically relevant results were obtained. It was demonstrated that this method could be used either in acute cases or for long-time measurements. We think that using a microtip probe for intracompartmental pressure measurement provides reliable data and makes the decision on fasciotomy much easier.

Anterior Compartment Syndrome↗

Experimental studies on the influence of fibrin adhesive, factor XIII, and calcitonin on the incorporation and remodeling of autologous bone grafts.

In an experimental study on sheep the effects of fibrin adhesive system (FAS), plasma factor XIII (FXIII), and calcitonin on autologous cancellous bone grafts were studied. Drill holes in the tibia were filled with transplant bone, either untreated or locally treated with fibrin adhesive, with or without plasma factor XIII. We used 24 sheep, divided into three groups. Plasma factor XIII and calcitonin were administered parenterally; the third group received no treatment. For evaluation we carried out quantitative bone and fluorescence morphometry and microangiography. We found that local fibrin adhesive significantly decreased the remodeling and growth of the transplanted cancellous bone. Plasma factor XIII, given parenterally, increased the amount of bone in the transplant site; calcitonin showed no visible effect.

Animals↗

Bone healing stimulated by plasma factor XIII. Osteotomy experiments in sheep.

Sheep had their right metatarsals osteotomized midshaft and stabilized by plate and screws. One group was injected with 1250 units of Factor Thirteen for 9 days postoperatively, and a control group received placebo injections. After 8 weeks, the bones were evaluated biomechanically, histomorphologically and by densitometry. The bones of the treated group had a significantly higher tensile strength than the bones of the control animals. The correlation of biomechanical and morphological results demonstrated that the tensile strength increased with an increasing number of osteons crossing the osteotomy gap. The hydroxyapatite content of the bone healing zone was 7.3 per cent higher for the treated bones than for the control bones.

Animals↗

[Complications at removal sites of autologous cancellous bone transplants].

1022 autologous bone transplants were performed at the University clinic of Ulm in the years 1971-1977. The cancellous bone deposits removed were localized in the anterior and posterior iliac crest, the trochanter major, the tibial head as well as the distal radius. Since some patients had postoperatively experienced difficulty in the healing of the cancellous bone removal sites, we decided to investigate these complications by means of questionnaires, clinical re-examinations as well as X-ray controls (3-9 years after removal). During the early postoperative phase (2 months), approximately one-fifth of the patients had complained about pain at the removal site. 3.1% had more or less pronounced hematomas in the scar regions, but surgical evacuation of the hematoma was necessary in only 0.28%. Additionally, 2 cases of infection as well as one femoral neck fracture following cancellous bone removal from the greater trochanter were observed. At the time of re-examination, performed 3-9 years after cancellous bone removal, only 3.9% of the patients complained of largely weather-influenced pains in the vicinity of the cutaneous scars. Sensibility disorders in the area innervated by the N. Cutaneous femoralis lateralis, were found in all those 7 patients who, in the course of cancellous bone removal from the iliac crest, had received skin incisions extending ventrally beyond the spina iliaca anterior superior. The X-ray controls showed more or less pronounced changes in the bone structure at the removal sites of cancellous bone deposits in nearly all patients, but correlation could only be determined between the radiological alterations at the anterior iliac crest donor site and the respective complaints of the patients.

Bone Diseases↗

[Biomechanical investigations about the transfer of axial load in different forms of plate-osteosynthesis (author's transl)].

The anchorage of various internal fixation plates on bones was tested. The results showed significant differences depending on the type of plates and the number of screws. Normal round hole plates slipped at higher forces more often than dynamic-compression plates (DCP). DC-plates with a rough surface revealed a higher strength than the same plates with a smooth surface. The anchorage strength of the plate-bone connection does not increase proportionally to the number of screws.

Biomechanical Phenomena↗

[Comparative investigations on the stability of fracture fixations with different fixateurs externes (author's transl)].

Short oblique fractures of the tibiae were stabilized with two-dimensional (frame spanner), three-dimensional and various V-shaped fixateurs externes, applied at the ventral-medial side. The stability of all these different types of fracture fixations was tested with and without an additional lag screw. Under a torsional load the stability of the area of osteotomy was measured. The three-dimensional fixateur externe and the V-shaped fixateur externe yielded the best results. The use of an additional lag screw produced a greater and significant (p less than 0,01) improvement.

Biomechanical Phenomena↗

[Biomechanical examination of stress distribution in the femoral neck for varus-implanted and valgus-implanted cups (author's transl)].

Femoral neck fractures occur after cup-prosthesis implantation and inadequate trauma. By reaming the head the tension stress in the lateral tension banding system of the femoral neck is reduced. Therefore high unphysiological bending moments occur in the medial trabecular system, which resists only high pressure forces. Our investigations showed that the unfavourable change in the stress distribution in the femoral neck is worse for the varus- than for the valgus-implanted cup. This could be the cause for the femoral neck fractures after cup implantation and inadequate trauma.

Biomechanical Phenomena↗

[Possibilities of geometric X-ray examination of the pelvis for partial pelvis replacement].

Patients with tumors of the pelvis, which cannot be treated by chemotherapy or radiation, must undergo hemipelvectomy. The postoperative prosthetic treatment was difficult und not always sufficient. So, a complete internal hemipelvectomy was done by replacement of an artificial part of half pelvis. Before the operation it was necessary to know the measurements of the pelvis exactly. This was done by taking X-ray pictures in anterior--posterior, lateral and axial direction which brought out the relevant diameters for the construction of the artificial pelvis. By using the Computer-Tomography we could get exact slices of the pelvis in the transversal plane. The slices were centrally positioned, then the model was covered with modelling-mass. The result was an exact positive feature of the pelvis which must be replaced.

Bone Neoplasms↗

Total "internal" hemipelvectomy.

Several authors have described resections of tumorbearing parts of the pelvis including reconstructive plastic surgery. With extensive tumor growth present mutilating hemipelvectomies often have been the last resort. Even the most sophisticated prostheses hardly ever enabled the patients to walk again. We have therefore performed total "internal" hemipelvectomies in three cases. The necessary substitute consisted of half a pelvis made of polyacetal resin produced from a given model. The model's measures and shape was established by computer tomograms thus resulting in an individually shaped pelvis half. The operative procedure aims at the maintenance of osseous muscular insertions and origins and their reconstruction. Utmost care has to be taken in avoiding damage to nerves and vessels. Fixation of the implant is performed by screws aiming through the sacroiliac joint into ala and corpus of the sacrum and corticocancellous grafts incorporated in the implant. The symphyses are united by means of plate fixation. The hip joint is substituted by a total prosthesis. With the procedure described we have managed three cases of extensive malignant tumors of the pelvis. One patient suffered a nerve lesion and skin necrosis with infection. The two remaining patients are capable of weight-bearing and standing on the inflicted leg alone.

Adolescent↗