Search PubMed⌕ Search

Biomedical subjects

H Gehring

Publications and source records attributed to H Gehring.

92 records · Page 6Linked to original sources

A prototype device for standardized calibration of pulse oximeters II.

OBJECTIVE: There is no commonly accepted in vivo calibration method for pulse oximeters available up to now. On the basis of a prototype device for the calibration of pulse oximeters which was introduced recently, a second approach based on the same concept was tackled in order to design a reliable method for standardized calibration of pulse oximeters. METHODS: An extensive clinical database of time-resolved optical transmission spectra of patient fingers is used to simulate the behavior of patients. A device which is capable of playing back these spectroscopic data to pulse oximeters, and a database where the oxygen status measured with the reference method (Co-Oximetry) is stored, are the main parts of the concept. The playback device has an artificial finger as interface to the pulse oximeters and serves to collect light from the pulse oximeter for analysis and to playback simulated light to the pulse oximeter. The light intensity emitted by two LEDs which illuminates the pulse oximeter detector is controlled via a computer in such a way that it is the same as if the pulse oximeter light had passed the finger. The pulse oximeter display during the data playback can thus be compared to the true SaO2 of the patient. The device is tested with 4 pulse oximeters based on 100 patient spectra. RESULTS: For the four pulse oximeters used in this investigation, an Agilent Technologies CMS monitor (formerly Hewlett-Packard), an Ivy 2000 with Masimo Set technology and Nellcor N-3000 and N-395, there is good correlation between SPO2 and SaO2, and mean and standard deviation of in vivo SpO2-SaO2 and playback SpO2-SaO2 are in good agreement. For two instruments, Nellcor N3000 and Agilent CMS Monitor, a quantitative comparison between the in vivo and in vitro SpO, results was derived. A mean of the deviation playback vs. in vivo SpO2 is less than 0.5% SpO2. The error limits are comparable with the calibration error of the conventional calibration routine. The device is also capable of data playback even in situations with rapid desaturation changes, as displayed in Figure 2. For the other tested pulse oximeters the results are comparable. CONCLUSIONS: Compared to the first prototype the current version is simpler and less expensive in production. Many of previously existing problems are solved and the applicability to a large variety of pulse oximeters and sensors is given. The novel concept for the calibration of pulse oximeters is a tool for assessing the performance of pulse oximeters.

Calibration↗

Concept for an intelligent anaesthesia EEG monitor.

Considering the fundamental difficulties to define the term 'depth of anaesthesia', a more feasible concept for assessment of 'adequacy of anaesthesia' will be explained. The basic requirements for a monitoring index are definite response, gradual scaling and independence from the anaesthetic technique used. Additionally the index should be predictive for appearance of clinical signs of an inadequate anaesthesia. Different signal-processing methods will be discussed to extract the relevant information from both the spontaneous and the evoked brain electrical activity. In this context well established methods like spectral analysis are investigated in combination with new and more sophisticated methods like bispectral analysis or wavelet decomposition. Since no single-parameter index has been defined for monitoring depth of anaesthesia, a set of EEG parameters may be more useful to take into account intra- and interindividual variability. In parallel to the description of the monitor concept, the investigation of neural nets and fuzzy techniques, in addition to or in substitution of conventional statistical methods, will be introduced. Examples are given for data quality assessment, parameter extraction and re-classification.

Algorithms↗