Measurement of transcellular fluid shift during haemodialysis. Part 1. Method.

A method is presented to measure transcellular fluid shifts during haemodialysis based on a simplified model of the electrical admittance of biological tissues. It allows for the measurement of intracellular and extracellular conductivities and their ratios. The method is noninvasive, clean and harmless, and can be easily computerised in order to be performed continuously. A typical example is given of a recording during haemodialysis.

Body Fluids↗

A transducer for recording fetal movements and sounds based on an inductive principle.

Recording fetal breathing movements requires a transducer with a large dynamic range. The compliance of the transducer should be matched to the compliance of the maternal abdominal wall in order to pass the very weak acoustic signal caused by heart sounds and fetal breathing movements on to the transducer. The output signal is stored on the hard disc of a personal computer (PC) simultaneously with a control signal indicating the presence of breathing movements. Ultrasound imaging is exclusively used for verification of breathing movements. The images are stored on videotape simultaneously with control signals from the PC for synchronisation of data and image. Substantial digital filtering is necessary to discriminate between actual breathing movements and other fetal activities. It is shown that by optimal adjustment of the transducer's compliance to that of the maternal abdominal wall individual breathing movements can indeed be measured.

Female↗

A transducer for detection of fetal breathing movements.

The paper describes a new transducer for detection of fetal movements and sounds from the maternal abdominal wall. This transducer is based on an inductive principle. The compliance of the transducer should match the compliance of the maternal abdominal wall in order to detect the very weak acoustic signal caused by individual fetal breathing movements. The contact area of the transducer is supported on a membrane, the tension of which can be adjusted so as to match the compliances of tissue and transducer. The goal of this paper is to investigate detection of fetal movements in order to monitor fetal condition and motility. The more specialized field of investigating fetal heart rate variability by studying the relationship between fetal breathing movements and fetal heart rate may become of more interest in the future. The inductive phonometer (INPHO) shows a flat (+/- 1.5 dB) frequency response between 0.2 and 200 Hz which is not affected by the compliance adjustment. Some in vivo measurements have been performed. The transducer signal is stored on a 20MB hard disk of an Olivetti M24 Personal Computer (PC) simultaneously with a control signal indicating the presence of breathing movements. Ultrasound imaging is exclusively used for verification of breathing movements. The images are stored on videotape simultaneously with control signals from the PC for synchronization of data and image. Substantial digital filtering is necessary to discriminate between actual breathing movements and other fetal activities. It is shown that optimal adjustment of the transducer's compliance to that of the maternal abdominal wall is possible and that individual breathing movements can indeed be measured.

Female↗

System for continuous high-resolution measurement of distances in the eye.

We describe a new system for accurate measurement of intraocular distances; it is used in conjunction with standard A-scan ultrasound equipment. A processing unit has been developed which enables selection of time intervals between echoes. Up to four intervals can be chosen and simultaneously measured. The output of the system is derived from a pulse duration-to-voltage converter which presents an output voltage proportional to the selected time interval. In this way variations in intraocular distances larger than about 0.01 mm can be detected.

Biophysical Phenomena↗

Generation of a fast and homogeneous temperature step.

A method is described for the fast and homogeneous increase of the temperature of a biological specimen with a volume of 1 mm3 or less. Heating is obtained by joule dissipation from a 30 MHz alternating current. The step quality is determined by measuring the temporal and spatial behaviour of the temperature after a power pulse in and around the biological preparation. With the described equipment a temperature step of 3 degrees C can be obtained in 8 ms. The temperature step inhomogeneity is less than 15%. The compatibility of the method with electrophysiological and mechanical measurement and instrumentation is demonstrated by the detection of transients in transmembrane potential and force of a papillary muscle from the rabbit heart.

Action Potentials↗

A general-purpose microprocessor system for medical instrumentation and electrical stimulation.

The article describes the design of a user-defined multipurpose system based on the Zilog Z-80, 8-bit microprocessor. The basic concept comprises a mainframe with a keyboard/display interface for communication between user and system. Different types of instrumentation equipment can be obtained using the same mainframe; only the contents of the program memory have to be changed. Up to seven programmable input/output boards can be installed. Some special-purpose boards are constructed to improve the versatility of the system. The major advantage of the presented system is that it can be applied at any time in the laboratory in an experiment or in the hospital for diagnostic or therapeutic purposes, without the engagement of existing computer memory.

Biomedical Engineering↗

On-line electrical impedance measurement for monitoring blood viscosity during on-pump heart surgery.

BACKGROUND: The viscosity of blood (eta) as well as its electrical impedance at 20 kHz at high shear rate depends on hematocrit, temperature, concentration of macromolecules and red cell deformability. The aim of our study was to investigate the relation between viscosity and electrical impedance in a heart-lung machine-like set-up, because during on-pump heart surgery considerable viscosity changes occur. METHODS: Blood of 10 healthy volunteers was examined under temperature variation between 18.5 and 37 degrees C at four different levels of hemodilution. Blood viscosity was examined with a golden-standard technique, i.e. a Contraves LS 30 Couette viscometer, and the results were compared with measurements of the electrical resistivity (R) at 20 kHz by a specially designed device in series with the tubing system of a heart-lung machine. All measurements were performed at a shear rate of 87 s(-1). RESULTS: Using stepwise multiparameter regression analysis (SPSS) a highly significant correlation was found (r(2) = 0.882) between viscosity (eta) and resistivity (R). Adding the variables sodium ([Na(+)]) and fibrinogen ([Fibr]) concentration the coefficient of correlation further improved to r(2) = 0.928 and the relation became: eta = -0.6844 + 0.038 R + 0.038 [Na(+)] + 0.514 [Fibr]. All coefficients showed a statistical significance of p < 0. 001. CONCLUSIONS: Electrical impedance measurement is feasible in a heart-lung machine-like set-up and allows accurate continuous on-line estimation of blood viscosity; it may offer an adequate way to record and control viscosity changes during on-pump heart surgery.

Adult↗