Search PubMedSearch

Biomedical subjects

H F Voigt

Publications and source records attributed to H F Voigt.

At least 19 recordsLinked to original sources

Sound-power collection by the auditory periphery of the mongolian gerbil Meriones unguiculatus. II. External-ear radiation impedance and power collection.

Acoustic power flow into the external and middle ear of the gerbil is computed from acoustic measurements and models of the external ear and used to predict the behavioral auditory threshold. The external-ear radiation impedance from the tympanic ring ZE measured in six gerbil ears with a calibrated acoustic source at frequencies from 10 Hz to 18 kHz is mass dominated below about 8 kHz, with a mean mass of 2720 kg/m4. ZE shows resonant behavior near 8 and 14 kHz. The frequency dependence of ZE is similar to that measured in cat, chinchilla, and models of the human external ear, but the mass and the resonant frequencies are higher. The power utilization ratio (PUR) computed from ZE and measurements of the middle-ear input impedance ZT presented previously [Ravicz et al., J. Acoust. Soc. Am. 92, 157-177 (1992)] suggests that appreciable power is transmitted to the middle ear only above 1.5 kHz. Mathematical external-ear models, consisting of tube segments and conical horns that include viscous and thermal losses, were developed from anatomical dimensions to match ZE over the entire frequency range of measurement. The radiation efficiency eta R computed from the models is near unity only above 12 kHz and falls to 10(-5) as frequency decreases to 10 Hz. Predictions of the mean pressure gain from an external diffuse sound field to the tympanic membrane resemble measurements in another gerbilline species. The effective area of the ear in a diffuse sound field at the tympanic membrane EATMDF computed from PUR and eta R approaches the anatomical area of the pinna opening, 71 mm2, above 1.5 kHz and the geometric limit of lambda 2 /4 pi determined by the wavelength lambda above 12 kHz but decreases sharply below 1.5 kHz to 0.002 mm2 at 10 Hz. The diffuse-field sound pressure required to deliver 5 x 10(-17) W to the middle ear between 10 Hz and 18 kHz resembles the behavioral auditory threshold [Ryan, J. Acoust. Soc. Am. 54, 1222-1226 (1976)]. This result supports the idea that the cochlea acts as a power detector at the auditory threshold.

Acoustics

Response properties of units in the dorsal cochlear nucleus of unanesthetized decerebrate gerbil.

1. The electrophysiological responses of single units in the dorsal cochlear nucleus of unanesthetized decerebrate Mongolian gerbil (Meriones unguiculatus) were recorded. Units were classified according to the response map scheme of Evans and Nelson as modified by Young and Brownell, Young and Voigt, and Shofner and Young. Type II units have a V-shaped excitatory response map similar to typical auditory nerve tuning curves but little or no spontaneous activity (SpAc < 2.5 spikes/s) and little or no response to noise. Type I/III units also have a V-shaped excitatory map and SpAc < 2.5 spikes/s, but have an excitatory response to noise. Type III units have a V-shaped excitatory map with inhibitory sidebands, SpAc > 2.5 spikes/s, and an excitatory response to noise. Type IV-T units typically also have a V-shaped excitatory map with inhibitory sidebands, but have a highly nonmonotonic rate versus level response to best frequency (BF) tones like type IV units, SpAc > 2.5 spikes/s, and an excitatory response to noise. Type IV units have a predominantly inhibitory response map above an island of excitation of BF, SpAc > 2.5 spikes/s, and an excitatory response to noise. We present results for 133 units recorded with glass micropipette electrodes. The purpose of this study was to establish a normative response map data base in this species for ongoing structure/function and correlation studies. 2. The major types of units (type II, type I/III, type III, type IV-T, and type IV) found in decerebrate cat are found in decerebrate gerbil. However, the percentage of type II (7.5%) and type IV (11.3%) units encountered are smaller and the percentage of type III (62.4%) units is larger in decerebrate gerbil than in decerebrate cat. In comparison, Shofner and Young found 18.5% type II units, 30.6% type IV units, and 23.1% type III units using metal electrodes. 3. Two new unit subtypes are described in gerbil: type III-i and type IV-i units. Type III-i units are similar to type III units except that type III-i units are inhibited by low levels of noise and excited by high levels of noise whereas type III units have strictly excitatory responses to noise. Type IV-i units are similar to type IV units except that type IV-i units are excited by low levels of noise and become inhibited by high levels of noise whereas type IV units have strictly excitatory responses to noise. Type III-i units are approximately 30% of the type III population and type IV-i units are approximately 50% of the type IV population. 4. On the basis of the paucity of classic type II units and the reciprocal responses to broadband noise of type III-i and type IV-i units, we postulate that some gerbil type III-i units are the same cell type and have similar synaptic connections as cat type II units. 5. Type II and type I/III units are distinguished from one another on the basis of both their relative noise response, rho, and the normalized slope of the BF tone rate versus level functions beyond the first maximum. Previously, type II units were defined to be those nonspontaneously active units with rho values < 0.3 where rho is defined as the ratio of the maximum noise response minus spontaneous rate to the maximum BF tone response minus spontaneous rate. In the gerbil, the average rho value for type II units is 0.25, although a few values are > 0.3, and the rate-level curves are consistently nonmonotonic with normalized slopes steeper than than -0.007/dB. The average rho value for type I/III units is 0.54, although a few values are < 0.3, and the rate-level curves tend to saturate with slopes shallower than -0.006/dB. In general, the response properties of type II units recorded in gerbil are similar to those recorded in decerebrate cat. 6. In comparison to decerebrate cat, the lower percentage of type IV units recorded in decerebrate gerbil may be due to a species difference (a reduced number of type II units in gerbil) or an electrode bias.

Animals

A two-channel action-potential generator for testing neurophysiologic data acquisition/analysis systems.

A 2-channel action-potential generator system was designed for use in testing neurophysiologic data acquisition/analysis systems. The system consists of a personal computer controlling an external hardware unit. This system is capable of generating 2 channels of simulated action potential (AP) waveshapes. The AP waveforms are generated from the linear combination of 2 principal-component template functions. Each channel generates randomly occurring APs with a specified rate ranging from 1 to 200 events per second. The 2 trains may be independent of one another or the second channel may be made to be excited or inhibited by the events from the first channel with user-specified probabilities. A third internal channel may be made to excite or inhibit events in both of the 2 output channels with user-specified rate parameters and probabilities. The system produces voltage waveforms that may be used to test neurophysiologic data acquisition systems for recording from 2 spike trains simultaneously and for testing multispike-train analysis (e.g., cross-correlation) software.

Action Potentials

Neuron labeling by extracellular delivery of horseradish peroxidase in vivo: a method for studying the local circuitry of projection and interneurons at physiologically characterized sites.

An anatomical method is described that yields individual neurons with continuously labeled dendrites and axons following the extracellular deposition of horseradish peroxidase (HRP) at neurophysiological recording sites in vivo. The method is a logical evolution of previous methods for iontophoretic delivery of HRP: Parameters critical to the ultimate concentration of HRP at the labeling site are reduced by an order of magnitude relative to standard practice. In successful cases one neuron or two in the immediate vicinity (50 microns) of recording sites is/are labeled. Labeling of other processes traversing the injection site, if any, is subliminal at highest light microscopic magnification. Due to the labeling of so few cells and the absence of other labeled processes, dendritic trees and local axonal arbors can be reconstructed without ambiguity. In addition to recovering neurons at sites characterized with physiological (e.g., sensory) stimuli, the method offers the further advantage of being fully compatible with subsequent electron microscopy. Both large (> 20 microns) and small (approximately 8 microns) neuron types and glia have been labeled.

Animals

A statistically based method to generate response maps objectively.

One scheme to classify the physiological response properties of single units in the cochlear nucleus is based on the average discharge rate of the unit and is reflected in the distribution of excitatory and inhibitory regions in a frequency-level map (response map) that spans the unit's receptive area (e.g., Evans and Nelson, 1973; Young and Brownell, 1976; Young and Voigt, 1982; Shofner and Young, 1985, Spirou and Young, 1991). Typically, discharge rate versus level curves are acquired at many frequencies and the investigator determines that a unit is excited or inhibited at a given level if the driven rate is above or below a spontaneous rate estimate by a specified criterion (for example, 20%). The investigator then encloses regions of excitation and inhibition where responses over adjacent frequencies and levels are consistent. In the present report, we describe an objective 3-step computer-based method to generate response maps: raw driven and spontaneous rate estimates are smoothed with a low-pass spatial filter; a unit is said to be excited or inhibited at a given level if the filtered driven rate is above or below the mean filtered spontaneous rate for that frequency by a specified criterion (percentage or statistical); and resultant response maps are median spatial filtered to eliminate spurious regions. The results shown here demonstrate that use of a statistical criterion provides a more reliable detection of excitation and inhibition than a 20% criterion, particularly when the variance of the rate estimates is high. Further, the statistically based method permits unit classification based on response map data that are more rapidly acquired with shorter duration stimuli (32 vs. 200 ms). Although this method is applied to units recorded in the dorsal cochlear nucleus, the technique may be applicable to studies of receptive fields and their plasticity in other systems.

Acoustic Stimulation

Neural modeling of the dorsal cochlear nucleus: cross-correlation analysis of short-duration tone-burst responses.

A conceptual model of a portion of dorsal cochlear nucleus (DCN) neural circuitry has emerged over the past two decades. This model suggests that the response properties of the DCN's major projection neurons, called type IV units, are due, in part, to the behavior of local circuit inhibitory interneurons called type II units (Young and Brownell 1976). Cross-correlation studies of simultaneously recorded pairs of DCN units in decerebrate cat derived from 50-s best frequency (BF) stimuli are consistent with and have extended this conceptual model (Voigt and Young 1980, 1985, 1988, 1990). Interestingly, Gochin et al. (1989) found no signs of inhibition in the anesthetized rat DCN in cross-correlograms derived from 55-ms short-duration BF tone bursts. This seemingly contradictory result has motivated this study. Computer simulations were run using our network model of the intrinsic DCN neural circuitry. This model has previously been shown to reproduce the major features of both type II and type IV rate-level curves and the inhibitory trough (IT) observed in cross-correlograms derived from long-duration stimuli (Voigt and Davis 1994). The goal was to study the stimulus-duration-dependent strength of ITs in the cross-correlograms derived from short-duration BF tone-burst stimuli. The results suggest that ITs may not be detectable when the stimulus duration is 50 ms but may be detectable when the stimulus duration is 200 ms or greater. Furthermore, when the ITs are detected in cross-correlograms derived from 200-ms data sets, the strength of the IT, as measured by effectiveness, is comparable to the strength of ITs measured when the stimulus duration is 50 s.

Acoustic Stimulation

A comparison of N1 of the whole nerve action potential and wave i of the brain-stem auditory evoked response in Mongolian gerbil.

The present study seeks to provide empirical support for the assumption that wave i of the gerbil brain-stem auditory evoked response (BAER) corresponds to N1 of the whole nerve action potential (WNAP) by comparing the latency and amplitude of BAER wave i and WNAP N1. Fourteen 3-month old gerbils were anesthetized with Nembutal and Urethane-Dial. Normothermia was maintained by a homeothermic blanket system. BAERs were recorded with Grass needle electrodes placed subdermally. The WNAP was recorded with a silver wire placed in the round window niche. WNAP and BAER were simultaneously recorded with a passband of 100-10,000 Hz. Responses consisted of 500 sweeps, and two responses were obtained for each condition. Clicks were 25-microseconds electrical pulses. Tonebursts were shaped with a Hanning window, with 1-ms rise and fall times. Toneburst frequencies included 1, 2, 4, 8, and 16 kHz. For each stimulus, responses were obtained at levels of 30, 50, 70, and 90 dB pSPL. SPL was measured near the entrance to the ear canal with an Etymotic ER-7C probe microphone. Dependent variables were the latency and amplitude of N1 of the WNAP and wave i of the BAER. The latencies of wave i and N1 were very similar. Mean (across animal) latencies of N1 and wave i were within 70 microseconds for all six stimuli (clicks, tonebursts) and all four levels. Latency/intensity function slopes for N1 and wave i were also very similar, with both dependent variables showing an increasing latency/intensity function slope with decreasing toneburst frequency. The N1/wave i amplitude ratio was computed.(ABSTRACT TRUNCATED AT 250 WORDS)

Acoustic Stimulation

Neural organization and responses to complex stimuli in the dorsal cochlear nucleus.

The dorsal division of the cochlear nucleus (DCN) is the most complex of its subdivisions in terms of both anatomical organization and physiological response types. Hypotheses about the functional role of the DCN in hearing are as yet primitive, in part because the organizational complexity of the DCN has made development of a comprehensive and predictive model of its input-output processing difficult. The responses of DCN cells to complex stimuli, especially filtered noise, are interesting because they demonstrate properties that cannot be predicted, without further assumptions, from responses to narrow band stimuli, such as tones. In this paper, we discuss the functional organization of the DCN, i.e. the morphological organization of synaptic connections within the nucleus and the nature of synaptic interactions between its cells. We then discuss the responses of DCN principal cells to filtered noise stimuli that model the spectral sound localization cues produced by the pinna. These data imply that the DCN plays a role in interpreting sound localization cues; supporting evidence for such a role is discussed.

Acoustic Stimulation

Sound-power collection by the auditory periphery of the Mongolian gerbil Meriones unguiculatus. I: Middle-ear input impedance.

This is the first paper of a series dealing with sound-power collection by the auditory periphery of the gerbil. The purpose of the series is to quantify the physiological action of the gerbil's relatively large tympanic membrane and middle-ear air cavities. To this end the middle-ear input impedance ZT was measured at frequencies between 10 Hz and 18 kHz before and after manipulations of the middle-ear cavity. The frequency dependence of ZT is consistent with that of the middle-ear transfer function computed from extant data. Comparison of the impedance and transfer function suggests a middle-ear transformer ratio of 50 at frequencies below 1 kHz, substantially smaller than the anatomical value of 90 [Lay, J. Morph. 138, 41-120 (1972)]. Below 1 kHz the data suggest a low-frequency acoustic stiffness KT for the middle ear of 970 Pa/mm3 and a stiffness of the middle-ear cavity of 720 Pa/mm3 (middle-ear volume V MEC of 195 mm3); thus the middle-ear air spaces contribute about 70% of the acoustic stiffness of the auditory periphery. Manipulations of a middle-ear model suggest that decreases in V MEC lead to proportionate increases in KT but that further increases in middle-ear cavity volume produce only limited decreases in middle-ear stiffness. The data and the model point out that the real part of the middle-ear impedance at frequencies below 100 Hz is determined primarily by losses within the middle-ear cavity. The measured impedance is comparable in magnitude and frequency dependence to the impedance in several larger mammalian species commonly used in auditory research. A comparison of low-frequency stiffness and anatomical dimensions among several species suggests that the large middle-ear cavities in gerbil act to reduce the middle-ear stiffness at low frequencies. A description of sound-power collection by the gerbil ear requires a description of the function of the external ear.

Acoustic Impedance Tests

Stimulus dependencies of the gerbil brain-stem auditory-evoked response (BAER). III: Additivity of click level and rate with noise level.

Two experiments were performed that evaluated the effects of ipsilateral-direct broadband noise maskers on the gerbil brain-stem auditory-evoked response (BAER) to click stimuli. In experiment 1, clicks were presented at 27 Hz at levels including 70, 80, 90, and 100 dB pSPL. Noise conditions included a no-noise control, and included noise levels varying in 10-dB increments from 20 dB SPL to a maximum noise level of 50, 60, 70, and 80 dB SPL for click levels of 70, 80, 90, and 100 dB pSPL, respectively. Gerbil BAER peaks were labeled with small roman numerals to distinguish them from human BAER peaks. The dependent variables included waves i and v latencies and amplitudes. Peak latencies increased and peak amplitudes decreased with decreasing click level and increasing noise level. To a first approximation, peak latencies and amplitudes showed changes with increasing noise level that were similar across click level. With increasing click level, there was little or no effect on the i-v interval. There was an increase in the i-v interval with increasing noise level. In experiment 2, click level was held constant at 90 dB pSPL, and click rates included 15, 40, 65, and 90 Hz. For each click rate, noise conditions included a no-noise control, and noise levels included 20, 30, 40, 50, 60, and 70 dB SPL. With increasing click rate and noise level, there was an increase in peak latencies, an increase in the i-v interval, and a decrease in peak amplitudes. The magnitude of peak latency and amplitude shifts with increasing click rate was dependent on noise level. Specifically, the magnitude of rate-dependent changes decreased with increasing level of broadband noise. These data are compared to human BAER experiments, and are found to be in fundamental agreement.

Animals

Cross-correlation analysis of inhibitory interactions in dorsal cochlear nucleus.

1. Cross-correlation analysis was used to study the organization of inhibitory connections between type II or type III units and type IV principal cells in cat dorsal cochlear nucleus (DCN). Pairs of units were isolated using two microelectrodes so that information about the distance over which connections are made could be analyzed. Data were obtained from 51 pairs consisting of a type II and a type IV unit and from 22 pairs consisting of a type III and a type IV unit. The analyses in this paper concentrate on type II-type IV pairs. 2. Inhibitory troughs (ITs) are observed in the cross-correlograms of type II-type IV pairs (21/51 cases). An IT is a transient decrease in discharge probability in the postsynaptic (type IV) unit immediately after spikes in the presynaptic unit (type II). The average latency to the start of ITs is 0.73 ms, and the troughs are asymmetric with a faster leading phase. Small excitatory peaks accompany the ITs in type II units, but these are probably secondary effects associated with the IT. ITs are consistent with a monosynaptic, inhibitory connection between type II and type IV units. A variety of evidence suggests that type II responses are recorded from vertical cells, an interneuron in the deep layer of the DCN that may be glycinergic. 3. The cross-correlograms of type III-type IV pairs are more complex and variable than those of type II-type IV pairs--ITs are seen in 4/22 cases, and peaks of correlation that are symmetrically located around the origin (central mound or CM) are seen in 4/22 cases; two cases have both an IT and a CM. CMs result from shared sources of input. Whereas type II-type IV correlogram features change primarily in amplitude as stimulus conditions change, correlogram features in some type III-type IV pairs change qualitatively with stimulus conditions; correlograms are flat for some stimuli and show ITs or CMs or mixtures of the two for others. This variability suggests that the circuitry associated with type III-type IV pairs is more complex than a monosynaptic connection, and further analysis of type III-type IV pairs was not done. 4. The strength of inhibition for an IT is measured as the area under the IT (effectiveness) and as effectiveness divided by the postsynaptic discharge rate (association index).(ABSTRACT TRUNCATED AT 400 WORDS)

Animals

Brainstem auditory-evoked response in the rat. Normative studies, with observations concerning the effects of ossicular disruption.

Six young adult Sprague-Dawley rats were unilaterally cochleotomized, Brain-stem auditory-evoked responses (BAERs) to clicks and to 1-, 2-, 4-, 8- and 16-kHz tone bursts were obtained. In addition, response thresholds were estimated before and after ossicular disruption in the noncochleotomized ear of 4 animals. With increasing tone burst frequency, there was a decrease in BAER peak latencies as well as a decrease in threshold. With increasing click and tone burst intensity, there was a decrease in peak latencies and an increase in peak amplitudes. BAER peak latency/intensity functions to click stimuli ranged from -.013 to -.018 ms/dB. With increasing tone burst frequency there was a decrease in the slope of the latency/intensity function. Following ossicular disruption, BAER thresholds to clicks were elevated by an average of 49 dB. Threshold shifts to tone burst stimuli were smallest for 1- and 2-kHz tone bursts (35-36 dB) and increased with increasing frequency up to a maximum of 65 dB for 16-kHz tone bursts.

Animals

Stimulus dependencies of the gerbil brain-stem auditory-evoked response (BAER). I: Effects of click level, rate, and polarity.

Three experiments evaluating the effects of various stimulus manipulations on the click-evoked gerbil brain-stem auditory-evoked response (BAER) are reported. In experiment 1, click polarity and level were covaried. With increasing click level, there is a parallel decrease in the latency of the first five BAER peaks (i-v) and an increase in BAER peak amplitudes. Mean wave i amplitude was greater for rarefaction than condensation clicks at high click levels; mean wave v amplitude was greater for condensation clicks at higher click levels. Experiment 2 covaried click rate and polarity. The latency of the BAER peaks increased with increasing click repetition rate. This rate-dependent latency increase was greater for the later BAER peaks, resulting in an increase in the i-v interval with increasing click rate. As rate increased, the amplitudes of waves i and v decreased monotonically, whereas the amplitudes of waves ii-iv were largely uninfluenced by click rate. As in experiment 1, mean wave i amplitude was greater for rarefaction clicks, whereas mean wave v amplitude was greater for condensation clicks. The magnitude of these polarity dependencies on waves i and v amplitude decreased with increasing click rate. Experiment 3 evaluated the effects of click polarity on BAERs to high-intensity (100 dB pSPL) clicks presented at a rate of 10 Hz. In eight of ten gerbils evaluated, wave i amplitude was greater to rarefaction clicks, and, in all ten animals, wave v amplitude was greater to condensation clicks. The effects of click level and rate on BAER peak amplitudes, latencies, and interwave intervals are reminiscent of stimulus dependencies reported for the human BAER. The effects of click polarity on the amplitudes of waves i and v of the gerbil BAER have also been reported for the human BAER.

Acoustic Stimulation

Stimulus dependencies of the gerbil brain-stem auditory-evoked response (BAER). II: Effects of broadband noise level and high-pass masker cutoff frequency across click polarity.

Two experiments concerning the effects of masking noise on the gerbil brain-stem auditory-evoked response (BAER) are reported. Experiment 1 evaluated the effects of broadband masking noise on the BAER obtained to condensation and rarefaction clicks. With increasing noise level, there was an increase in BAER peak latencies, an increase in the i-v interval, and a decrease in peak amplitudes. Experiment 2 evaluated the effects of high-pass masking noise on the BAER obtained to condensation and rarefaction clicks. Both high-pass responses and derived-band responses were evaluated. For high-pass responses, with decreasing masker cutoff frequency, there was an increase in BAER peak latencies, a decrease in the i-v interval, and a decrease in peak amplitudes. For derived-band responses, with decreasing derived-band frequency, there was an increase in peak latencies and a decrease in the i-v interval. A comparison of wave i and wave v amplitudes across derived-band frequency demonstrates a greater contribution of high-frequency cochlear regions to wave i than wave v. Small, insignificant, effects of click polarity on BAER peak amplitudes were observed. These trends were in the direction seen in a companion paper [R. Burkard and H. F. Voigt, J. Acoust. Soc. Am. 85, 2514-2525 (1989)] and were, in general, reduced by the presence of broadband or high-pass maskers.

Acoustic Stimulation

Neural correlations in the dorsal cochlear nucleus: pairs of units with similar response properties.

1. Cross-correlation analysis of simultaneously recorded spike trains can be used to gain insight into functional interactions among neurons. In this paper, we report on cross-correlation analysis of neuron pairs in the dorsal cochlear nucleus (DCN) of the cat. Neuron pairs were isolated with two independent electrodes, which allow systematic study of the effects on correlation of distances between units and differences in their best frequencies (BFs). The data in this paper were obtained from 51 pairs consisting of two neurons of the same type. 2. Cross-correlograms were obtained for 35 pairs composed of type IV units, which are recorded from the principal cells of the DCN. Pairs of type IV units with correlated activities give cross-correlograms with increased correlation near zero delay. This feature is called a central mound (CM) and most likely results from shared excitatory or shared inhibitory inputs. 3. Records of spontaneous activity were obtained from 31 pairs of type IV units. Six of these pairs have correlated spontaneous activities. All six pairs have BFs that differ by less than 0.2 octaves. The shared input inducing these correlations must be a spontaneously active and tonotopically organized projection, like the auditory nerve. Type II units, thought to be DCN inhibitory interneurons that project to type IV units, are not spontaneously active, and thus cannot be the cause of correlated spontaneous activity. Similarly, cochlear granule cells, whose axons project orthogonally to the tonotopic sheets of DCN, cannot be the cause of correlated spontaneous activity because their projection is not confined tonotopically. 4. Stimulus-driven activities were studied for 12 type IV pairs that have uncorrelated spontaneous activities. Five of these pairs have correlated driven activities, with CMs whose sizes depend on the frequency and sound level of the acoustic stimulus. A frequency vs. sound level correlation response map shows the V-shaped tuning properties of the correlation-inducing mechanism. The properties of stimulus-driven correlation in these type IV pairs are consistent with the hypothesis that the correlation is induced by shared input from DCN type II units, although this is not the only possibility. 5. All six type IV pairs with correlated spontaneous activities have correlated driven activities. In five of these pairs, the degree of correlation decreases from its value with spontaneous activity when a low-level acoustic stimulus is applied. Three of these five pairs were tested at higher stimulus levels.(ABSTRACT TRUNCATED AT 400 WORDS)

Acoustic Stimulation

A simple device for the computer quantification of depth measurements in thick light microscope sections.

The use of computerized techniques to characterize quantitatively the anatomy of individual neurons has been increasing. One difficulty has been the quantification of the z-axis or depth measurements within thick light microscopic sections. In the present report we describe a simple device which employs an incremental optical encoder to transduce the movements of the focusing knob of the microscope so that depth information can be recorded directly by a computer. A resolution of 0.13 micron over a range of approximately 8.5 cm is achieved. The mechanical interface to the microscope is simple and applicable to a wide variety of microscopes. Interfacing circuits which allow the optical encoder to be used with an IBM-PC compatible computer are presented and described. The accuracy of the depth measurements is limited only by the mechanical tolerances of the focusing mechanism and by the optics of the microscope.

Electric Wiring

Stimulus dependent neural correlation: an example from the cochlear nucleus.

Results of several recent cross-correlation studies have been interpreted in terms of "neuronal plasticity" and "stimulus dependent wiring diagrams" produced by presumed dynamic neural reorganization mechanisms. Presented here are examples of stimulus-dependent cross-correlograms observed in a pair of type IV units recorded in the dorsal cochlear nucleus (DCN). The interpretation of these correlation data is based on current hypotheses of DCN circuitry. It is suggested that plasticity mechanisms are not responsible for these stimulus-dependent correlations. A more likely mechanism is one that allows various portions of a hard wired neural circuit to be selectively activated by the stimuli.

Acoustic Stimulation

Auditory nerve representation of vowels in background noise.

Responses of auditory nerve fibers to steady-state vowels presented alone and in the presence of background noise were obtained from anesthetized cats. Representation of vowels based on average discharge rate and representation based primarily on phase-locked properties of responses are considered. Profiles of average discharge rate versus characteristic frequency (CF) ("rate-place" representation) can show peaks of discharge rate in the vicinity of formant frequencies when vowels are presented alone. These profiles change drastically in the presence of background noise, however. At moderate vowel and noise levels and signal/noise ratios of +9 dB, there are not peaks of rate near the second and third formant frequencies. In fact, because of two-tone suppression, rate to vowels plus noise is less than rate to noise alone for fibers with CFs above the first formant. Rate profiles measured over 5-ms intervals near stimulus onset show clear formant-related peaks at higher sound levels than do profiles measured over intervals later in the stimulus (i.e., in the steady state). However, in background noise, rate profiles at onset are similar to those in the steady state. Specifically, for fibers with CFs above the first formant, response rates to the noise are suppressed by the addition of the vowel at both vowel onset and steady state. When rate profiles are plotted for low spontaneous rate fibers, formant-related peaks appear at stimulus levels higher than those at which peaks disappear for high spontaneous fibers. In the presence of background noise, however, the low spontaneous fibers do not preserve formant peaks better than do the high spontaneous fibers. In fact, the suppression of noise-evoked rate mentioned above is greater for the low spontaneous fibers than for high. Representations that reflect phase-locked properties as well as discharge rate ("temporal-place" representations) are much less affected by background noise. We have used synchronized discharge rate averaged over fibers with CFs near (+/- 0.25 octave) a stimulus component as a measure of the population temporal response to that component. Plots of this average localized synchronized rate (ALSR) versus frequency show clear first and second formant peaks at all vowel and noise levels used. Except at the highest level (vowel at 85 dB sound pressure level (SPL), signal/noise = +9 dB), there is also a clear third formant peak. At signal-to-noise ratios where there are no second formant peaks in rate profiles, human observers are able to discriminate second formant shifts of less than 112 Hz. ALSR plots show clear second formant peaks at these signal/noise ratios.

Animals