Search PubMed⌕ Search

Biomedical subjects

H Chu

Publications and source records attributed to H Chu.

At least 19 recordsLinked to original sources

A batch study on the bio-fixation of carbon dioxide in the absorbed solution from a chemical wet scrubber by hot spring and marine algae.

Carbon dioxide mass transfer is a key factor in cultivating micro-algae except for the light limitation of photosynthesis. It is a novel idea to enhance mass transfer with the cyclic procedure of absorbing CO(2) with a high performance alkaline abosorber such as a packed tower and regenerating the alkaline solution with algal photosynthesis. Hence, the algae with high affinity for alkaline condition must be purified. In this study, a hot spring alga (HSA) was purified from an alkaline hot spring (pH 9.3, 62 degrees C) in Taiwan and grows well over pH 11.5 and 50 degrees C. For performance of HSA, CO(2) removal efficiencies in the packed tower increase about 5-fold in a suitable growth condition compared to that without adding any potassium hydroxide. But ammonia solution was not a good choice for this system with regard to carbon dioxide removal efficiency because of its toxicity on HSA. In addition, HSA also exhibits a high growth rate under the controlled pHs from 7 to 11. Besides, a well mass balance of carbon and nitrogen made sure that less other byproducts formed in the procedure of carboxylation. For analysis of some metals in HSA, such as Mg, Mn, Fe, Zn, related to the photosynthesis increased by a rising cultivated pH and revealed that those metals might be accumulated under alkaline conditions but the growth rate was still limited by the ratio of bicarbonate (useful carbon source) and carbonate. Meanwhile, Nannochlopsis oculta (NAO) was also tested under different additional carbon sources. The results revealed that solutions of sodium/potassium carbonate are better carbon sources than ammonia carbonate/bicarbonate for the growth of NAO. However, pH 9.6 of growth limitation based on sodium was lower than one of HSA. The integrated system is, therefore, more feasible to treat CO(2) in the flue gases using the algae with higher alkaline affinity such as HSA in small volume bioreactors.

Air Pollutants↗

Anomalous decrease in groundwater radon before the Taiwan M6.8 Chengkung earthquake.

On December 10, 2003, an earthquake of magnitude (M) 6.8, the strongest since 1951, occurred near the Chengkung area in eastern Taiwan. Approximately 65 d prior to the 2003 Chengkung earthquake, precursory changes in the groundwater radon concentration were observed at the Antung radon-monitoring station located 20 km from the epicenter. The radon anomaly was a decrease from a background level of 28.9 BqL(-1) to a minimum of 12.2 BqL(-1). Observations at the Antung hot spring suggest that the groundwater radon, when observed under suitable geological conditions, can be a sensitive tracer for strain changes in the crust preceding an earthquake.

Disasters↗

Characterization of southern Taiwan red soils as a regenerable sorbent for sorption of hydrogen sulfide from coal gas with spectroscopic techniques.

The purpose of this research is to use red soils as a high-temperature regenerable sorbent for sorption of hydrogen sulfide from coal gas and collocates with a series of spectroscopic apparatuses in order to investigate the structure changes after multiple sorption/regeneration processes. Results indicate that red soils could be reused after 10 multiple sorption/regeneration cycles and maintain approximately 80% sorption efficiency. With EDS and EA analyses, residual sulfur species are detected in the 10th regenerated red soils and exist with values of 0.6 and 0.33%, respectively. Undesired sulfur species including sulfide, sulfate and elemental sulfur are further identified by XPS spectroscopy. With the best regression fitting results, sulfate species is the dominative sulfur species, which occupies approximately 71% of residual sulfur. It is believed that these residual sulfur species are the major cause to result in red soils' deterioration after regeneration and reduce the sorption efficiency. Appreciable amounts of regeneration gases CO, CO(2) and SO(2) are detected by on-line FTIR spectroscopy. Their formation mechanisms are attributed to the different gas-solid reaction, one is the reaction of carbon and oxygen, and the other is FeS and oxygen. From the analysis of solid-state nuclear magnetic resonance spectroscopy (SSNMR), a significant change for (27)Al and (29)Si and it is established that a portion of aluminum is reformed into pentacoordinated structure. Formation of aluminosilicate is maybe another reason to result in deterioration as a result of the loss of surface area.

Coal↗

Spectroscopic study on sorption of hydrogen sulfide by means of red soil.

This paper reports the results of the characterization of red soils in relation to the sorption of H2S from coal gas at 500 degrees C by spectroscopic techniques in order to provide more information on red soils' structural change both before and after reaction. In addition, by-products analysis has also been studied using Fourier transform infrared (FTIR) spectroscopy. Before and after the experiments the red soils were characterized with X-ray powder diffraction (XRPD), energy dispersion spectrum (EDS), X-ray photoelectron spectroscopy (XPS) and FTIR spectroscopy. XRPD results indicate that iron oxide species disappear from the original to reacted red soil. EDS analysis shows that a significant amount of sulfur is present in the reacted red soil, which is in agreement with the results of the elemental analysis and the calculated value based on breakthrough curve. XPS regression fitting results further indicate that sulfur retention may be associated with the iron oxides. S 2p XPS fittings point out that the major sulfur species present in the reacted red soil are composed of S(-2), elemental sulfur, polysulfide, sulfite and sulfate. Additionally, the binding energy of iron shifts to a lower position for the reacted red soil, which indicates that iron oxides in the original red soil have been converted into iron sulfide. Appreciable amounts of the by-products CO2, SO2 and COS are detected by on-line FTIR spectroscopy during the initial and later stages of the sorption process. The formation of CO2 is related to the water-shift reaction, and SO2 is probably attributable to the reaction of organic matters and H2S. The concentration of COS is quantified by GC/FPD and found it to be about 350 ppm, which is close to the equilibrium concentration of the reaction of inlet CO and H2S at a temperature of 500 degrees C.

Color↗

High temperature removal of hydrogen sulfide using an N-150 sorbent.

In this study, an N-150 sorbent was used as a high temperature desulfurization sorbent for the removal of hydrogen sulfide from coal gas in a fixed bed reactor. The results indicate that the N-150 sorbent could be used for H(2)S removal in the tested temperature ranges. Regeneration test also reveals that utilization of the N-150 sorbent maintains up to 85% compared to the fresh sorbent. No significant degeneration occurs on the N-150 sorbent. In addition, various concentrations of H(2)S, H(2) and CO were also considered in the performance test of the N-150 sorbent. Except for H(2)S, H(2) and CO act the important roles in the high temperature desulfurization. By increasing the H(2) concentration, the sulfur capacity of the sorbent decreases and an adverse result is observed in the case of increasing CO concentration. This can be explained via water-shift reaction. On the basis of the instrument analysis, X-ray powder diffraction determination and SEM images with EDS spectrum characterization, residual sulfur is found in the regenerated N-150 sorbent and this sulfur species is sulfate which resulted by incomplete regeneration. The sulfate formation and sintering effect are major reasons to cause activity loss in the sulfidation/regeneration cycles.

Absorption↗

One year comparison of costs of coronary surgery versus percutaneous coronary intervention in the stent or surgery trial.

OBJECTIVES: To compare initial and one year costs of coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) in the stent or surgery trial. DESIGN: Prospective, unblinded, randomised trial. SETTING: Multicentre study. PATIENTS: 988 patients with multivessel disease. INTERVENTIONS: CABG and stent assisted PCI. MAIN OUTCOME MEASURES: Initial hospitalisation and one year follow up costs. RESULTS: At one year mortality was 2.5% in the PCI arm and 0.8% in the CABG arm (p = 0.05). There was no difference in the composite of death or Q wave myocardial infarction (6.9% for PCI v 8.1% for CABG, p = 0.49). There were more repeat revascularisations with PCI (17.2% v 4.2% for CABG). There was no significant difference in utility between arms at six months or at one year. Quality adjusted life years were similar 0.6938 for PCI v 0.6954 for PCI, Delta = 0.00154, 95% confidence interval (CI) -0.0242 to 0.0273). Initial length of stay was longer with CABG (12.2 v 5.4 days with PCI, p < 0.0001) and initial hospitalisation costs were higher (7321 pounds sterling v 3884 pounds sterling for PCI, Delta = 3437 pounds sterling, 95% CI 3040 pounds sterling to 3848 pounds sterling). At one year the cost difference narrowed but costs remained higher for CABG (8905 pounds sterling v 6296 pounds sterling for PCI, Delta = 2609 pounds sterling, 95% CI 1769 pounds sterling to 3314 pounds sterling). CONCLUSIONS: Over one year, CABG was more expensive and offered greater survival than PCI but little added benefit in terms of quality adjusted life years. The additional cost of CABG can be justified only if it offers continuing benefit at no further increase in cost relative to PCI over several years.

Angioplasty, Balloon, Coronary↗

Laboratory study of poisoning of a MnO/Fe2O3 catalyst by dimethyl sulfide and dimethyl disulfide.

The catalytic incineration of dimethyl sulfide and dimethyl disulfide in a MnO/Fe(2)O(3) fixed bed catalytic reactor was studied. This paper provides information on the affect of the operating parameters that included: inlet temperature, space velocity, VOC concentration and O(2) concentration. The results show that the conversion of VOCs increases as the inlet temperature increases and the space velocity decreases. The higher the concentration of VOCs, the lower their conversions. The O(2) concentration has no affect on the conversion of VOCs. VOCs have poisoning affects on the MnO/Fe(2)O(3) catalyst, especially at lower temperatures.

Catalysis↗

Off-pump coronary artery bypass grafting provides complete revascularization with reduced myocardial injury, transfusion requirements, and length of stay: a prospective randomized comparison of two hundred unselected patients undergoing off-pump versus conventional coronary artery bypass grafting.

OBJECTIVE: Retrospective comparisons of selected patients undergoing off-pump versus conventional on-pump coronary artery bypass grafting have yielded inconsistent results and raised concerns about completeness of revascularization in off-pump coronary artery bypass grafting. METHODS: Two hundred unselected patients referred for elective primary coronary artery bypass grafting were randomly assigned to undergo off-pump coronary artery bypass grafting with an Octopus tissue stabilizer (Medtronic, Inc, Minneapolis, Minn) or conventional coronary artery bypass grafting with cardiopulmonary bypass by a single surgeon. Revascularization intent determined before random assignment was compared with the revascularization performed. All management followed strict, unbiased, criteria-driven protocols. Patients and nonoperative care providers were blinded to surgical group. RESULTS: Baseline characteristics were similar. The number of grafts performed per patient (mean +/- SD 3.39 +/- 1.04 for off-pump coronary artery bypass grafting, 3.40 +/- 1.08 for conventional coronary artery bypass grafting) and the index of completeness of revascularization (number of grafts performed/number of grafts intended, 1.00 +/- 0.18 for off-pump coronary artery bypass grafting, 1.01 +/- 0.09 for conventional coronary artery bypass grafting) were similar. Likewise, the index of completeness of revascularization was similar between groups for the lateral wall. Combined hospital and 30-day mortalities and stroke rates were similar. Postoperative myocardial serum enzyme measures were significantly lower after off-pump coronary artery bypass grafting, suggesting less myocardial injury. Adjusted postoperative thromboelastogram indices, fibrinogen, international normalized ratio, and platelet levels all showed significantly less coagulopathy after off-pump coronary artery bypass grafting. Patients undergoing off-pump coronary artery bypass grafting received fewer units of blood, were more likely to avoid transfusion altogether, and had a higher hematocrit at discharge. Cardiopulmonary bypass was an independent predictor of transfusion (odds ratio 2.42, P =.0073) by multivariate analysis. More patients undergoing off-pump coronary artery bypass grafting were extubated in the operating room and within 4 hours. Postoperative length of stay (in days) was shorter for off-pump coronary artery bypass grafting (5.1 +/- 6.5 for off-pump coronary artery bypass grafting, 6.1 +/- 8.2 for conventional coronary artery bypass grafting, P =.005 by Wilcoxon test). One patient (in the conventional coronary artery bypass grafting group) required angioplasty for graft closure within 30 days. CONCLUSIONS: When compared with conventional coronary artery bypass grafting with cardiopulmonary bypass, off-pump coronary artery bypass grafting achieved similar completeness of revascularization, similar in-hospital and 30-day outcomes, shorter length of stay, reduced transfusion requirement, and less myocardial injury.

Blood Transfusion↗

A feasibility study on the predictive emission monitoring system applied to the Hsinta power plant of Taiwan Power Company.

The continuous emission monitoring system (CEMS) can monitor flue gas emissions continuously and instantaneously. However, it has the disadvantages of enormous cost, easily producing errors in sampling periods of bad weather, lagging response in variable ambient environments, and missing data in daily zero and span tests and maintenance. The concept of a predictive emission monitoring system (PEMS) is to use the operating parameters of combustion equipment through thermodynamic or statistical methods to construct a mathematic model that can predict emissions by a computer program. The goal of this study is to set up a PEMS in a gas-fired combined cycle power generation unit at the Hsinta station of Taiwan Power Co. The emissions to be monitored include nitrogen oxides (NOx) and oxygen (O2) in flue gas. The major variables of the predictive model were determined based on the combustion theory. The data of these variables then were analyzed to establish a regression model. From the regression results, the influences of these variables are discussed and the predicted values are compared with the CEMS data for accuracy. In addition, according to the cost information, the capital and operation and maintenance costs for a PEMS can be much lower than those for a CEMS.

Automation↗

Distribution and determinants of trihalomethane concentrations in indoor swimming pools.

OBJECTIVES: For many decades chlorination has been used as a major disinfectant process for public drinking and swimming pool water in many countries. However, there has been rising concern over the possible link between disinfectant byproducts (DBPs) and adverse reproductive outcomes. The purpose of this study was to estimate the concentrations of trihalomethanes (THMs) in some indoor swimming pools in London and their variation within and between pools and any correlation with other factors. METHODS: Water samples were collected from eight different indoor swimming pools in London. A total of 44 pool samples were collected and analysed for total organic content (TOC) and THMs. Water and air temperature were measured along with the pH during the collection of pool samples. The level of turbulence and the number of people in the pool at the time were also assessed. RESULTS: The geometric mean concentration for all swimming pools of TOC was 5.8 mg/l, of total THMs (TTHMs) 132.4 microg/l, and for chloroform 113.3 microg/l. There was a clear positive linear correlation between the number of people in the swimming pool and concentrations of TTHMs and chloroform (r=0.7, p<0.01), and a good correlation between concentrations of TOC and TTHMs (r=0.5, p<0.05) and water temperature and concentrations of TTHMs (r=0.5, p<0.01). There was a larger variation in THMs within pools than between pools. CONCLUSION: Relatively high concentrations of THMs were found in London's indoor swimming pools. The levels correlated with the number of people in the pool, water temperature, and TOC. The variation in concentrations of THMs was greater within pools than between pools.

Air Pollutants↗

The kinetics of catalytic incineration of styrene over a MnO/Fe2O3 catalyst.

Catalytic incineration is one of the cost-effective technologies to deal with unwanted volatile organic compounds (VOCs). Catalytic incineration of styrene over a MnO/Fe2O3 catalyst was carried out in a bench scale catalytic incinerator. Three kinetic models, the power-rate law, the Mars and van Krevelen model and the Langmuir-Hinshelwood model were used to analyze the results. A differential reactor design was used for best fit of kinetic models in this study. The results show that the Langmuir-Hinshelwood model may be feasible to describe the catalytic incineration of styrene. This suggests that the chemical adsorption of either O2 molecules or O atoms is important in the process of catalytic incineration of styrene.

Journal Article↗

Simultaneous absorption of SO2 and NO from flue gas with KMnO4/NaOH solutions.

The wet scrubbing combined SOx/NOx removal system is an advanced air pollution control device. This study attempts to understand the absorption kinetics in the system. The absorption of diluted SO2 and simultaneous absorption of diluted SO2 and NO, as occurs in flue gases, in a stirred tank reactor with KMnO4/NaOH solutions were carried out at 50 degrees C. The liquid-side and gas-side mass transfer coefficients of the system were determined. The results indicate that the absorption of SO2 is close to completely gas-film controlled where the NaOH concentration is greater than 0.1 M or the KMnO4 concentration is greater than 0.05 M. The increasing gas flow rate has a positive effect on the absorption rate of SO2. The existence of O2 has no significant effect on the absorption rate of SO2. Adding SO2 would decrease the absorption rate of NO; however, the addition of NO has no effect on the absorption rate of SO2.

Absorption↗

The absorption kinetics of NO in NaClO2/NaOH solutions.

A combined wet scrubbing SOx/NOx removal system is an advanced air pollution control process. In this process, the mechanism of NO removal is relatively unknown. Consequently, absorption of NO by alkaline solutions of NaClO2 was studied to clarify the reaction kinetics. The experiments were carried out mainly at temperature 50 degrees C which is the common operating temperature for wet scrubbers. The assumption that the absorption occurred under the fast pseudo-mth reaction regime was verified in the experiments. The absorption rate of NO into NaClO2 solutions was found to be proportional to P(2)NO,0 and [NaClO2]0(2). The addition of NaOH to solutions of NaClO2 decreased the absorption rate of NO. The absorption rate of NO at 25 degrees C is lower than at 50 degrees C. In the study, the absorption rate of NO did not change with changing gas flow rates.

Absorption↗

The catalytic incineration of (CH3)2S and its mixture with CH(3)SH over a Pt/Al(2)O(3) catalyst.

Catalytic incineration is one of the cost-effective technologies to solve the troublesome volatile organic compounds (VOCs). However, some sulfur containing VOCs, such as dimethyl sulfide, may deactivate the Pt catalyst that is commonly used in the catalytic incineration process. This paper provides information on the poisoning effect of (CH3)2S. The catalytic incineration of (CH3)2S, typically emitted from the petrochemical industry, over a Pt/Al(2)O(3) fixed bed catalytic reactor was studied. The effects of operating parameters including inlet temperature, space velocity, (CH3)2S concentration, O2 concentration and catalyst size were characterized. Catalytic incineration on a mixture of (CH3)2S with CH(3)SH was also tested. The results show that the conversions of (CH3)2S increase as the inlet temperature increases and the space velocity decreases. The higher the (CH3)2S concentration is, the lower its conversion is. The O2 concentration has a positive effect on the conversion of (CH3)2S. (CH3)2S has a poisoning effect on the Pt/Al(2)O(3) catalyst, especially at lower temperatures. The conversion of (CH3)2S is significantly suppressed by the existence of CH(3)SH.

Air Pollution↗

The kinetics of catalytic incineration of C2H5SH and (CH3)2S2 over a Pt/Al2O3 catalyst.

Catalytic incineration is one of the cost-effective technologies to solve the troublesome VOCs. However, some sulfur containing VOCs, such as ethyl mercaptan and dimethyl disulfide, may deactivate the Pt catalyst that is commonly used in the catalytic incineration process. The catalytic incineration of these compounds over a Pt/Al2O3 catalyst was carried out in a bench scale catalytic incinerator. Three kinetic models, such as power-rate law, Mars and Van Krevelen model, and Langmuir-Hinshelwood model were used to analyze the results. A differential reactor design was used for best fit of kinetic models in this study. The results show that the Langmuir-Hinshelwood model is feasible to describe the catalytic incineration of both C2H5SH and (CH3)2S2. This suggests that the chemical adsorption of O2 molecule is important in the process of catalytic incineration of C2H5SH and (CH3)2S2.

Adsorption↗

The kinetics of catalytic incineration of dimethyl sulfide and dimethyl disulfide over an MnO/Fe2O3 catalyst.

The catalytic incineration of dimethyl sulfide and dimethyl disulfide [(CH3)2S and (CH3)2S2] over an MnO/Fe2O3 catalyst was carried out in a bench-scale catalytic incinerator. Three kinetic models (i.e., the power-rate law, the Mars and Van Krevelen model, and the Langmuir-Hinshelwood model) were used to analyze the results. A differential reactor design was used for best fit of kinetic models in this study. The results show that the Langmuir-Hinshelwood model may be feasible to describe the catalytic incineration of (CH3)2S and (CH3)2S2. This suggests that the chemical adsorption of O2 molecules is important in this incineration.

Adsorption↗

Spray scrubbing of the nitrogen oxides into NaClO2 solution under acidic conditions.

The operating conditions of this study were closed to the typical operating conditions of flue gas desulfurization system in the coal-fired power plant. The objective of this study was to investigate the absorption performance of lean NO in an aqueous solution of acidic sodium chlorite using a bench-scale spraying column. The NO conversion and NOx removal efficiency were increasing with the increasing NO concentration, retention time, sodium chlorite concentration, operating temperature, and decreasing initial pH of solution. As the sodium chlorite concentration were higher than 0.4 M, the NO conversion and NOx removal efficiency were 100% and 80%, respectively. The NO conversion and NOx removal efficiency under initial pH 4-7 were higher than that of initial pH > 7. It meant that this process might be suitable to combining with traditional wet flue gas desulfurization system. As the NO2/NOx ratio in the effluent gas was closed to 0.5, it might be suitable to be absorbed in the second scrubbing column operated under alkaline condition.

Adsorption↗

Detection and analysis of depolarization artifacts in rotating-compensator polarimeters.

Absolute constraints, namely, the Schwarz inequality and a complementary expression derived by us, are used to obtain corresponding absolute constraints on the Fourier coefficients of the intensity transmitted through rotating-compensator polarimeters and ellipsometers. These expressions allow the investigation of artifacts that result in mixed or apparently mixed polarization states over the cross section of the beam, the averaging time of the detector, or the frequency passband of the dispersing element. Examples include multiple internal reflections or inhomogeneous strain within an element, scattered light, and other types of system and component defects that cannot be accessed by means of polarization-state data alone. We apply these results to our polarizer-sample-compensator-analyzer (PSCA) ellipsometer to illustrate capabilities. A simple analytic model is shown to give a quantitative description of depolarization in systems for which the resolution is finite and the retardation varies with wavelength.

Journal Article↗