Search PubMed⌕ Search

Biomedical subjects

H C Kim

Publications and source records attributed to H C Kim.

At least 343 records · Page 19Linked to original sources

Comparison of antiproliferative effects of 1-histamine-2 receptor antagonists, cimetidine, ranitidine, and famotidine, in gastric cancer cells.

In the immune system, histamine is known to suppress cytotoxic T-lymphocytes and nitrogen induced lymphocyte thymidine uptake, down-regulate some cytokines, and activate suppressor T-lymphocytes, and in the gastrointestinal system, histamine was reported to have trophic effects on gastrointestinal epithelial cells. Enhanced rates of cell proliferation by histamine are implicated in the pathogenesis. This study was designed since there is a lack of comparative data about the cell proliferations of histamine-2 receptor antagonist (H2-RA), cimetidine, ranitidine, and famotidine, in gastric cancer. KATO-III and AGS cell lines were used in this experiment. The concentrations of the histamine and cimetidine were 10(-5)-10(-8) M, respectively and those of ranitidine and famotidine were 10(-6)-10(-9)M, respectively. Cell proliferation after drug treatment was evaluated by direct cell counting, [3H]thymidine incorporation, and MTT assay. Activities of ornithine decarboxylase (ODC), a rate limiting enzyme in polyamine synthesis, were measured after each drug treatment. Protein kinase A, a cAMP-dependent protein kinase system, was assayed using [alpha-32P]ATP. Histamine showed statistically significant cell proliferating effects in a dose-dependent manner (P < 0.001), the maximal effect in 10(-5) M concentration. ODC activities were increased in accordance with the increment of cell numbers after histamine treatment. Cimetidine reversed the histamine-stimulated cell proliferation significantly, the maximal effect in 10(-5) M concentration (P < 0.01). Although ranitidine showed the tendency to attenuate the cell proliferation dose-dependently, but without statistical significance, famotidine did not show such an effect at all. cAMP-dependent protein kinase activities were significantly increased following 10(-5) M histamine treatment, also reversed significantly by cimetidine co-administration (P < 0.01). Beneficial clinical outcomes could be anticipated from cimetidine treatment in patients with gastric cancer by anti-proliferating effects against gastric cancer cells. These effects of H2-RA are likely to be mediated by specific interactions at the H2-receptor.

Adenocarcinoma↗

Promotional effects of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) on N-nitrosobis(2-oxopropyl)amine (BOP)-initiated carcinogenesis in hamsters.

The effects of administration of low doses of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), a tobacco-specific nitrosamine, were investigated in hamsters treated with N-nitrosobis(2-oxopropyl)amine (BOP). Female Syrian golden hamsters were given a single sc injection of BOP at a dose of 10 mg/kg and then administered 2 or 5 ppm NNAL in their drinking water for 52 wk. Additional groups of animals received the BOP injection alone, or only the 2 or 5 ppm NNAL treatments as BOP-negative controls. At wk 53 of the experiment, all surviving animals were killed and the development of proliferative lesions was assessed histopathologically. The total incidence of combined carcinomatous and dysplastic lesions of the exocrine pancreas was significantly higher (P < 0.05) in the BOP/NNAL 5 ppm group than in the BOP alone group, although there was no statistically significant influence of NNAL on the development of either pancreatic adenocarcinomas or dysplastic lesions viewed singly. The treatments with NNAL alone did not induce any proliferative lesions of the exocrine pancreas. No significant intergroup differences were found in either incidence or multiplicity of islet cell proliferative lesions. Immunohistochemical examination of islet cell proliferative lesions (hyperplasias and adenomas) found in the BOP-treated animals showed no significant differences in pancreatic hormone production between NNAL-treated and -untreated groups. The NNAL treatment did not exert any influence on lung, liver or kidney tumorigenesis. Thus, the results suggest that NNAL enhances BOP-induced exocrine but not endocrine pancreatic tumorigenesis in hamsters when given in the post-initiation phase.

Animals↗

Neonatal thrombosis with anticardiolipin antibody in baby and mother.

The anticardiolipin antibody is associated with increased risk of thrombosis, which is manifested with various clinical presentations, including vascular thrombosis, recurrent fetal wastage, and neurologic defects. We report a case of neonatal thrombosis occurring in the renal vein and inferior vena cava associated with moderate positive anticardiolipin antibody titer in the baby while the maternal serum showed even stronger anticardiolipin antibody of immunoglobulin G class. Subsequent follow-up over the 4 months postpartum period showed a disappearance of the antibody in the baby, whereas the mother's antibody persisted. This case illustrates the fact that the maternal anticardiolipin antibody can be transferred to the fetus and may be a risk factor for thrombosis in the neonates. Anticardiolipin antibody syndrome should be considered in the differential diagnosis of neonatal thrombosis.

Adult↗

Noninvasive diagnosis of mechanical failure of the implanted total artificial heart using neural network analysis of acoustic signals.

Acoustic signal measurement has been proposed as a noninvasive method of detecting mechanical failure of the implanted total artificial heart. However, differences in acoustic spectra obtained from undamaged and damaged devices may be difficult to distinguish using standard techniques, such as visual inspection or statistical analysis. A new technique, artificial neural network analysis, which has been used successfully on other problems of pattern recognition and classification, was applied to improve the detectability of the acoustic method. Acoustic signals were measured using two different devices in one damaged and one undamaged electrohydraulic total artificial heart, both in a mock circulation set-up and in animal experiments where they were implanted in eight post mortem sheep and the acoustic signal measured using a microphone placed at the skin surface. Spectra of the acoustic waveforms were calculated by discrete Fourier transformation and 400 values (representing the log magnitude in each 2.5 Hz band of the spectrum between 0 and 1 kHz) and used as input to the neural network. A three layer backpropagation neural network containing 400 input nodes, 20 intermediate nodes, and one output node was able to forms. The trained neural network then perfectly distinguished damaged waveforms from undamaged ones, with good separability. Because the neural network's output can take on a value between two extremes denoting damaged and undamaged states, it is possible to detect any progressive failure at relatively earlier stages. With multiple output node configuration, it could also classify the different types of damage using single acoustic signal waveforms.

Acoustics↗

In vitro characterization of a magnetically suspended continuous flow ventricular assist device.

A magnetically suspended continuous flow ventricular assist device using magnetic bearings was developed aiming at an implantable ventricular assist device. The main advantage of this device includes no mechanical wear and minimal chance of blood trauma such, as thrombosis and hemolysis, because there is no mechanical contact between the stationary and rotating parts. The total system consists of two subsystems: the centrifugal pump and the magnetic bearing. The centrifugal pump is comprised of a 4 vane logarithmic spiral radial flow impeller and a brushless DC motor with slotless stator, driven by the back emf commutation scheme. Two radial and one thrust magnetic bearing that dynamically controls the position of the rotor in a radial and axial direction, respectively, contains magnetic coils, the rotor's position sensors, and feedback electronic control system. The magnetic bearing system was able to successfully suspend a 365.5g rotating part in space and sustain it for up to 5000 rpm of rotation. Average force-current square factor of the magnetic bearing was measured as 0.48 and 0.44 (kg-f/Amp2) for radial and thrust bearing, respectively. The integrated system demonstrated adequate performance in mock circulation tests by providing a 6 L/min flow rate against 100 mmHg differential pressure at 2300 rpm. Based on these in vitro performance test results, long-term clinical application of the magnetically suspended continuous flow ventricular assist device is very promising after system optimization with a hybrid system using both active (electromagnet) and passive (permanent magnets) magnet bearings.

Biomechanical Phenomena↗

Development of a new blood pump using a shape memory alloy actuator.

A helical spring shape memory alloy actuator has been investigated to be used in a mechanical circulatory support system. The design procedure to determine shape memory alloy and passive bias spring specifications was established. A model device was designed to provide 2 cm stroke by a 100 cm2 pusher plate against a maximum 200 mm Hg pressure load. The prototype device was also developed to verify the feasibility of the shape memory alloy actuator and to confirm the design procedure. In vitro water bath test results verified the feasibility of the shape memory alloy actuator for use in a mechanical circulatory support system.

Alloys↗

Analysis of the interventricular pressure waveform in the moving-actuator total artificial heart.

Right and left filling pressures are important parameters in the automatic control of a total artificial heart (TAH) within normal physiologic ranges. Our TAH is composed of a moving actuator, right and left ventricles, and an interventricular space (IVS) enclosed by a semirigid housing. During operation of the TAH, the IVS volume is changed dynamically by the difference between the ejection volume of one ventricle and the inflow volume of the other. We measured the interventricular pressure (IVP) waveform by using a pressure sensor and analyzed the relationship between the IVP and the preload condition. From in vitro and in vivo experiments, we found that the measured filling pressures were linearly related to the negative peak value of the IVP. Additionally, we found that we could use the time interval from actuator start to the positive peak value of the IVP (outflow valve opening) as a useful parameter to estimate the blood filling volume of the diastole ventricle.

Animals↗

Hypointense boundary layer between slow flow and mural thrombus on spin-echo MR.

To evaluate the ability of spin-echo MRI to differentiate between slow flow and mural thrombus in aortic diseases, we reviewed the spin-echo MRI of 10 patients with intraaortic thrombus that had been documented by CT in 8 patients and aortography in 2 patients. Six patients had aortic aneurysms with mural thrombi, and four had aortic dissections with adherent mural thrombi within the false lumen. Five of seven gated oblique sagittal or coronal T1-weighted studies demonstrated hyperintense slow flow signal within the residual lumen. This hyperintense slow flow signal was accompanied by a parallel hypointense rim due to a boundary layer dephasing phenomenon. Eight axial T2-weighted MR studies demonstrated a hypointense zone due to fresh clot at the edge of a mural thrombus on even-echo images consistently. The hypointense boundary layer between slow flow and mural thrombus on either gated T1-weighted MRI or second-echo T2-weighted MRI not only predicted the presence of flow within the residual lumen but also clearly separated the area of slow flow from that of mural thrombus in 9 of 10 patients. Proper interpretation of spin-echo images may obviate the need for phase display imaging or gradient-echo imaging in differentiating between slow flow and mural thrombus.

Adult↗

Mediastinal Castleman disease: CT findings.

OBJECTIVE: Our objective was to characterize the CT findings of mediastinal Castleman disease. MATERIALS AND METHODS: We reviewed the CT findings of mediastinal Castleman disease in 10 patients. RESULTS: In nine cases of hyaline-vascular type Castleman disease, lymph nodes were 2-7 cm in diameter and located in the hilum in six patients, superior mediastinum in two patients, and posterior mediastinum in one patient. On CT the tumors were well-demarcated round masses showing dense homogeneous enhancement after contrast medium injection. Dynamic CT in one case showed gradual centripetal enhancement of the mass. In one case of hyaline-vascular type Castleman disease, lumpy and irregular calcifications were noted in the center of the mass. In the one case of plasma cell type Castleman disease, multiple small homogeneously enhancing nodes were found in the mediastinal and supraclavicular area. CONCLUSION: CT findings may suggest the preoperative diagnosis of mediastinal Castleman disease.

Adolescent↗

Entry tears of thoracic aortic dissections: MR appearance on gated SE imaging.

OBJECTIVE: The purpose of this study was to assess the ability of gated SE MR to demonstrate entry tears of thoracic aortic dissections and to elucidate their MR appearance. MATERIALS AND METHODS: Gated SE MR images of nine consecutive patients with nonthrombosed aortic dissection on aortography were retrospectively analyzed. RESULTS: Magnetic resonance consistently depicted an intimal flap and a double lumen in all nine patients. A focal intimal flap discontinuity suggesting an intimal tear was shown in eight patients. This intimal flap discontinuity was confirmed to be the entry tear by operation in five patients and by aortography in three. In five of eight patients with a focal intimal flap discontinuity, rapid influx of blood across an intimal defect produced a localized signal void area within the false lumen, which was surrounded by slow flow signal showing even-echo rephasing. This MR sign of a localized jet of flow void within the false lumen was very useful in determining the significance of a focal intimal flap discontinuity. CONCLUSION: Familiarity with these MR appearances of entry tears may enable their preoperative localization in a large proportion of aortic dissections on routine gated SE MRI.

Adult↗

CT features of primary colorectal signet-ring cell carcinoma.

PURPOSE: The purpose of this work was to evaluate the CT features of 15 patients with primary colorectal signet-ring cell carcinomas. METHOD: We retrospectively reviewed the CT scans of 15 patients (mean age 44 years) with pathologically proved colorectal signet-ring cell carcinoma. On CT, we evaluated the site and length of the tumor, bowel wall thickening patterns, perirectal or pericolic infiltration, the presence or absence of colonic obstruction, and metastasis to other organs. RESULTS: The tumors were located in the rectum in nine patients, the sigmoid colon in one, the hepatic flexure in one, the transverse colon in one, the ascending colon in two, and the cecum in one. The tumor length ranged from 4.0 to 10.0 cm (mean 6.1 cm) with mean thickness of 2.1 cm. CT showed concentric bowel wall thickening in all patients ("even" in 8 and "uneven" in 7), target appearance was noted in 4, perirectal or pericolic infiltrations were moderate to severe in 12, and colorectal obstruction was seen in 6. In the tumor spread patterns, lymphadenopathy was noted in 13, invasion to adjacent pelvic organs in 5, peritoneal carcinomatosis in 4, liver metastasis in 2, and periureteric metastasis in 1. CONCLUSION: Primary signet-ring cell colorectal carcinoma should be included for differential consideration when CT shows a long length of concentric bowel wall thickening and target sign, especially when such findings occur in the rectum and in young patients.

Adolescent↗

Preclinical application of radioimmunoguided surgery using anti-carcinoembryonic antigen biparatopic antibody in the colon cancer.

Radioimmunoguided surgery (RIGS) has been known as a sophisticated tool to detect micrometastasis intraoperatively. A preclinical model of RIGS was designed to test the possible clinical applicability of the biparatopic antibody in detecting colorectal cancer. The biparatopic antibody was constructed using two anti-carcinoembryonic antigen (CEA)-specific antibodies, T84.66 and PR1A3, reacting against two different epitopes. (125)I-labeled biparatopic antibody was introduced via the principal colonic arteries at the end of operation in 10 operable patients with colon cancer. After 24 h, the radioactivities of the tumors and lymph nodes were counted using the gamma-detecting probe. The radioactivity count was performed ex vivo. The accurate detection in the primary tumors and metastatic lymph nodes were 100 and 88.7% respectively. False-positive detections occurred in 24 of 256 lymph nodes (9.4%), whereas false-negative detections occurred in 5 of them (2%). The most frequent cause of false-positive detection was dissociated radionuclides trapped in the lymphatic tissues. False-negative detections occurred mainly from weak targeting by radiolabeled antibody, probably due to weak expression of tumor CEA. Conclusively, as most detection errors appear to be reduced within 3 days in vivo, the biparatopic antibody can efficiently be applied to the clinical RIGS, thereby facilitating accurate detection and removal of occult cancer foci in colorectal cancer.

Antibodies↗

Ramosetron for the prevention of cisplatin-induced acute emesis: a prospective randomized comparison with granisetron.

Control of nausea and vomiting is very important in determining patient compliance with cisplatin chemotherapy. A multicentre, randomized, single-blind study was conducted to compare the tolerability and efficacy of ramosetron with those of granisetron over 24 h following cisplatin administration to cancer patients. In eight study centres, a total of 194 adult patients were randomly assigned to receive either intravenous ramosetron 0.3 mg or intravenous granisetron 3.0 mg. The anti-emetic effect of ramosetron determined from the no-vomiting rate lasted longer, but there was no significant difference in the number of acute vomiting episodes or the severity of nausea between the two groups. In the tolerability evaluation, there were no statistically significant differences between the two groups, except for a higher incidence of dull headache in the granisetron group. Ramosetron and granisetron appear to have equivalent efficacy and tolerability profiles, but the effects of ramosetron on the prevention of acute vomiting in patients undergoing cisplatin chemotherapy were longer lasting.

Adult↗

Diffusion-weighted MR imaging in biopsy-proven Creutzfeldt-Jakob disease.

OBJECTIVE: To compare conventional and diffusion-weighted MR imaging in terms of their depiction of the abnormalities occurring in Creutzfeldt-Jakob disease. MATERIALS AND METHODS: We retrospectively analyzed the findings of conventional (T2-weighted and fluid-attenuated inversion recovery) and diffusion-weighted MR imaging in four patients with biopsy-proven Creutzfeldt-Jakob disease. The signal intensity of the lesion was classified by visual assessment as markedly high, slightly high, or isointense, relative to normal brain parenchyma. RESULTS: Both conventional and diffusion-weighted MR images demonstrated bilateral high signal intensity in the basal ganglia in all four patients. Cortical lesions were observed on diffusion-weighted MR images in all four, and on fluid-attenuated inversion recovery MR images in one, but in no patient on T2-weighted images. Conventional MR images showed slightly high signal intensity in all lesions, while diffusion-weighted images showed markedly high signal intensity in most. CONCLUSION: Diffusion-weighted MR imaging is more sensitive than its conventional counterpart in the depiction of Creutzfeldt-Jakob disease, and permits better detection of the lesion in both the cerebral cortices and basal ganglia.

Adult↗