Comparison of methods for detecting soluble fibrin in plasma. An in vitro study.

The ability of the COA-SET Fibrin monomer (COA-SET FM) test to detect soluble fibrin was evaluated by comparing the results of the COA-SET FM test with fibrinopeptide A (FPA) determinations following thrombin incubation of plasma or whole blood. In addition, two semiquantitative tests (erythrocytes-agglutination test (FM-test) and ethanol gelation test (EGT] were included in the study. Under the experimental conditions used, the COA-SET FM test proved less sensitive than the FPA-assay. There was a strong correlation between the results obtained by the two tests (r = 0.86, p = 0.0001). When solely regarding low levels of soluble fibrin, however, the correlation was weaker (r = 0.59, p = 0.0003). The FM-test was less sensitive than the COA-SET FM test, but more sensitive than EGT at normal and low fibrinogen concentrations. At high fibrinogen concentrations, however, EGT proved more sensitive than the FM-test. Knowing that 1-2 moles of FPA are released per mole of fibrin monomers formed, a discrepancy was observed between the FPA concentrations and the fibrin monomer concentrations as determined by the COA-SET FM test, the FPA levels being 2-25 times higher than the fibrin monomer levels. The discrepancy was greatest at incipient fibrinogen-fibrin transformation and at high plasma fibrinogen levels. This may suggest that fibrinogen in some way interfered with the stimulating effect of fibrin on the t-PA catalyzed activation of plasminogen, the principle upon which the COA-SET FM test is based.(ABSTRACT TRUNCATED AT 250 WORDS)

Ethanol↗

The influence of pH on heat denaturation of anti-haemophilic cryoprecipitate.

The influence of pH on heat denaturation of anti-haemophilic cryoprecipitate (CP) was studied by using phosphate and citrate buffers at three different pH levels for processing lyophilized, heat treated CP. The solubility and the content of FVIII:C and fibrinogen were determined following heating at 68 degrees C for 24 hours and compared to "ordinary", non-heated CP. Both the solubility and the biological activity were best preserved in the most acidic samples (pH 5.7-6.7), these batches equalled non-heated CP. At higher pH, heat treatment resulted in reduced solubility and a more pronounced loss of FVIII:C and fibrinogen. Amino acids (Syntamin 17) have previously been shown to stabilize CP during heat treatment. Some of the stabilizing effect seems to be due to a large buffering capacity, maintaining a low pH during lyophilization and heating. Raising the pH level in Syntamin-CP from 6.6 to 7.8 resulted in decreased solubility and FVIII:C content. The quality of heat treated, acidic Syntamin-CP was comparable to that of heated, acidic phosphate- and citrate-CP. We conclude that buffers used for processing heat treated CP should be of low pH, and that acidic buffers may replace Syntamin without lowering the quality of the heated product.

Amino Acids↗

Characteristics of a heat treated antihaemophilic cryoprecipitate.

In order to evaluate the influence of heat treatment (68 degrees C for 24 or 72 hours) on the essential components of antihaemophilic cryoprecipitate, i.e. factor VIII coagulant activity (VIII:C), von Willebrand factor (VIIIR:Ag and VIIIR:RCF) and fibrinogen, ordinary lyophilized cryoprecipitate was compared to heat treated, aminoacid-enriched specimens. The median reduction in factors VIII:C, VIIIR:Ag, VIIIR:RCF and fibrinogen during lyophilization of ordinary cryoprecipitate was 26 per cent, 11 per cent, 1 per cent and 8.5 per cent, respectively. Heat treatment of such cryoprecipitate resulted in 85 to 98.5 per cent reduction in these parameters, while the reduction following lyophilization and heat treatment (24 hours) of aminoacid-containing preparations was not significantly different from non-heated, ordinary cryoprecipitate. Following heating of aminoacid-enriched cryoprecipitate for 72 hours, only factor VIIIR:RCF was significantly reduced (32.5 per cent) compared to non-heated samples. Ordinary cryoprecipitate was almost insoluble following heat treatment. Enrichment with aminoacids, however, made the heat treated cryoprecipitate fully soluble, but the content of these vials were slightly slower in dissolving than non-heated preparations. Ultracentrifugation prior to lyophilization and heating did not improve the solubility. If heat treatment proves to be efficient in inactivating viral agents, we conclude that heated (68 degrees C for 24 hours), aminoacid-enriched cryoprecipitate may be a convenient product for treating haemophilia A, von Willebrand's disease and hypofibrinogenemia.

Acquired Immunodeficiency Syndrome↗

Thrombin generation during collection of blood from donors taking oral contraceptives.

Thrombin generation, as evidenced by plasma fibrinopeptide A (FPA) concentrations, was studied during blood collection from donors taking oral contraceptives (OC). 450 ml blood were drawn into Fenwal PVC bags from 26 OC users and 28 nonusers. Blood samples for determination of FPA, beta-thromboglobulin (BTG), thrombotest (TT), prekallikrein (PKK), antithrombin-III (AT-III) and factor VIII procoagulant activity (FVIII:C) were drawn from the bags immediately after ending blood donation and following storage for 24 h at 4 degrees C. The FPA concentrations following donation were significantly higher in the OC than in the control group (p less than 0.05). The levels of PKK were also higher in blood obtained from OC users (p less than 0.001), as was the FVIII:C level, the latter difference, however, was not significant (p = 0.06). No cold-promoted activation of factor VII, as evidenced from TT, was detected following storage at 4 degrees C, neither was any change observed in the FPA, PKK and AT-III levels. The BTG concentrations increased significantly during storage, most pronounced in the control group (p less than 0.05). The decay of FVIII:C was similar in the two groups, averaging 24.7%. No correlation was observed between the FPA levels and the other parameters determined. We conclude that thrombin generation is more pronounced during routine blood collection from donors taking OC.

Adult↗

Monoclonal IgM with lupus anticoagulant activity in a case of Waldenström's macroglobulinaemia.

Strong lupus anticoagulant activity was detected in the plasma of a 73-yr-old woman with Waldenström's macroglobulinaemia. Purified patient IgM caused significant prolongation of the APTT in concentrations as low as 30 micrograms/ml, and its activity was inhibited by intact or (more effectively) by frozen-thawed blood platelets. Employing varying concentrations of cephalin in the APTT assay, it was demonstrated that the macroglobulin had a direct cephalin-neutralizing effect. When tested in an ELISA system using phospholipid-coated microtiter wells, the IgM was shown to possess antibody activity against cephalin. With purified phospholipids as antigens, the protein was found to display antibody activity against phosphatidyl serine and phosphatidyl ethanolamine, which are main constituents of cephalin. These observations were confirmed in absorption experiments.

Aged↗

Binding of various thrombin fractions to fibrin and the influence of AT-III on their adsorption.

Human thrombin with high affinity for fibrin was obtained by subjecting purified thrombin to affinity chromatography on Sepharose insolubilized fibrin monomers, after addition of a radioiodinated subsample of thrombin, molar ratio 1:600. As judged by radioprofiling of the electrophoretic distribution of high-affinity thrombin on 10 per cent polyacrylamide gel containing urea/SDS, the preparation consisted of 70 per cent alpha-thrombin, 28 per cent beta-thrombin and only 2 per cent gamma-thrombin. Although alpha-thrombin was bound more strongly to insolubilized fibrin monomers than the other subfractions, complete separation of the individual components could not be achieved. High-affinity thrombin was employed for studies on thrombin adsorption to polymerized fibrin, assuming equal behaviour of labelled and unlabelled thrombin. To avoid passive entrapment of thrombin within the fibrin meshwork at physiological pH, ionic strength and calcium concentration, the optimal fibrinogen concentration was found to be 2.94 umol/l. During such conditions, adsorption of thrombin to polymerized fibrin did not exceed 65 per cent of added thrombin, despite an increasing availability of fibrin-related thrombin binding domains obtained by reducing the thrombin concentration. Adsorption of thrombin to polymerized fibrin increased by 25 per cent when the ionic strength was reduced to 0.05 mol/l. These findings suggest the presence of thrombin subfractions with different affinities for polymerized fibrin. Aggregates of high-affinity thrombin formed during its preparation by affinity chromatography, but were prevented by adding polyethylene glycol (m.w. 6,000, final conc. 6.6 g/l). Such aggregates were not inactivated by AT-III, but could still adsorb to polymerized fibrin.(ABSTRACT TRUNCATED AT 250 WORDS)

Adsorption↗

The release of small amounts of fibrinopeptide-B (FPB) is of critical importance for the thrombin clotting time.

When fibrinogen is clotted with thrombin, mainly fibrinopeptide-A (FPA) is released at gel point, the FPB-release being delayed. The present study present evidence that the small amounts of des-AABB fibrin found at visible gelation improves polymerization, thereby determining the thrombin clotting time. 1. Purified fibrinogen was clotted with thrombin or Reptilase, peptide release monitored radioimmunologically. With thrombin, significantly less fibrin (released FPA) was necessary for gel formation than when Reptilase was used. Furthermore, approximately 10% of the available FPB had been released by thrombin at gel point. 2. Polymerization of monomers prepared by incubation of fibrinogen with Reptilase (des-AA) and thrombin (des-AABB) in urea, were examined by light scattering. Des-AA fibrin monomers polymerised after a lag-phase of 4 minutes. When 20% of these monomers were substituted with des-AABB monomers, the lag was reduced to 1 1/2 minutes. 3. Finally, polymerization of preformed des-AA monomers was studied with and without the addition of small amounts of thrombin, and the FPB-release monitored. The presence of 0.04 NIH U/ml of thrombin reduced the lag from 10 minutes to 3 minutes. At this time approximately 10% of FPB had been released. It is concluded that even small amounts of des-AABB fibrin substantially improves polymerization of des-AA fibrin.

Blood Coagulation Tests↗

Fibrin generation during production of freeze dried antihaemophilic cryoprecipitate.

Thrombin activity during separation and cryoprecipitation of CPD-blood was monitored by fibrinopeptide A (FPA) determinations. After pooling and lyophilization of cryoprecipitate, the total amount of contaminating fibrin was estimated by N-terminal amino acid analyses. In addition, retention of fibrin in standard transfusion filters (170 micron) was examined by gamma counting of 125I des-AA fibrin monomer enriched cryoprecipitate prior and subsequent to filtration. Prior to pooling of cryoprecipitate, thrombin activity, as estimated by FPA levels, was most pronounced during collection of blood from the blood donors and during cryoprecipitation and thawing of the plasma bags. Comparison of these FPA concentrations to the total amount of fibrin in pooled, freeze dried cryoprecipitate, as estimated by N-terminal analyses, revealed a considerable generation of fibrin during the process of lyophilization. In freeze dried cryoprecipitate, 5.3 per cent (range 3.0-7.5 per cent) of the fibrinogen had been converted to fibrin, implying a fibrin content of 20.3-60.3 mg per bottle of 500 U factor VIII. The amount of fibrin in two bottles of a commercially available factor VIII concentrate, also containing 500 U of factor VIII, was 14.1 and 19.8 mg, respectively. Sham transfusions of 125I des-AA fibrin monomer enriched cryoprecipitate revealed that only 1.0 per cent (range 0-2.5 per cent) of the fibrin was retained in the standard transfusion filters. Thus, substantial amounts of fibrin may be transfused to patients upon treatment with freeze dried cryoprecipitate.

Drug Contamination↗

Contaminating fibrin in CPD-blood: solubility in plasma and distribution in blood components following separation.

In order to estimate the solubility of contaminating fibrin in CPD-blood, thrombin induced fibrin polymerzation in CPD-plasma was examined by light scattering and fibrinopeptide A (FPA) determinations. In addition, I125 fibrin monomer enriched CPD-blood was used to investigate fibrin monomer retention in blood bags and transfusion filters (170 microns) and fibrin distribution in blood components derived from CPD-blood. Initial fibrin polymerization in CPD-blood occurred after conversion of 15 per cent of the fibrinogen to fibrin, implying that substantial amounts of fibrin may be kept solubilized in CPD-blood bags. Only minor amounts of I125 fibrin monomers were retained in blood bags (2.4 per cent) and in transfusion filters (2.9 per cent) after sham transfusions. After separating I125-fibrin monomer enriched CPD-blood into its constituent components, the major part of fibrin (75.0 per cent) could be traced in the cryoprecipitate.

Adenine↗

Half life and incorporation into venous thrombi of the normally occurring plasma fibrinogen fractions HMW and LMW.

The main plasma fibrinogen species, high molecular weight fibrinogen (HMW, mw. 340,000) and LMW (mw. 305,000), displaying different in vitro properties, were examined as to half-life and incorporation into venous thrombi (DVT). Total plasma fibrinogen and relative amounts of HMW were measured pre- and postoperatively in eighteen patients undergoing total hip arthroplasty, and related to the occurrence of deep vein thrombosis, as determined by the fibrinogen uptake test (FUT). Total fibrinogen and HMW did not disclose significant differences between scan-negative and scan-positive groups. HMW and LMW, prepared from purified fibrinogen, were labelled with I125 and I131, injected simultaneously and the incorporation into thrombi registered by leg-scanning. In 5 patients demonstrating a positive FUT, HMW as well as LMW were incorporated approximately to the same extent. This result implies that neither of these fibrinogen fractions offer any advantage as compared to ordinary fibrinogen when used for FUT. The half-lives of HMW and LMW were calculated from the elimination curves of the plasma clot-radioactivity. In all the surgical patients (n = 10) as well as in the two medical DVT-patients and in two healthy volunteers the half-life of LMW was approximately 10% longer than that of HMW.