Search PubMed⌕ Search

Biomedical subjects

H C Bauknecht

Publications and source records attributed to H C Bauknecht.

7 recordsLinked to original sources

[Whole-body MR angiography: comparison of two protocols for contrast media injection].

PURPOSE: To compare two injection strategies for contrast media injection in whole-body MR angiography quantitatively and qualitatively with regard to contrast and image quality. MATERIAL AND METHODS: 40 patients were examined at 1.5 Tesla using either a single injection protocol or a double injection protocol with two separate bolus injections. Vessel regions I (supraaortic/thoracic), II (abdominal/pelvic), III (upper legs) and IV (lower legs) were examined in the following order: single injection: I, II, III, IV, double injection: I and IV after the first injection, II and III after the second bolus injection. Quantitative evaluation: SI measurements were carried out in 2 arteries per region. Contrast values were calculated. Qualitative evaluation: Evaluation of regions I-IV regarding vessel contrast, venous overlay and image quality on a five-point scale by two reviewers in consensus. The Mann-Whitney-U test was used to test the differences for significance. RESULTS: Quantitative evaluation: Using the double injection protocol, significantly higher contrast values in regions I and II and significantly lower contrast values in the subregions IIIa (upper part of III) and IVb (lower part of IV) were obtained (p < 0.05). The mean contrast values in subregions IIIb (lower part of III) and IVa (upper part of IV) were lower using the double injection protocol, but not significantly. Qualitative evaluation: Using the double injection protocol, region II was rated significantly higher (mean ratings: 3.55, 3.45 and 3.5 versus 2.7, 2.5 and 2.55; p < 0.05) and region III significantly lower (mean ratings: 3.1, 2, 2.5 versus 3.9, 3.1 and 3.55; p < 0.05) for all three examined criteria. When using the double injection protocol, ratings were significantly lower in region IV regarding vessel contrast and image quality (mean ratings: 2.4 and 2.15 versus 3.45 and 3.15; p < 0.05). The ratings regarding venous overlay in region IV showed no significant differences (mean ratings: 2.15 versus 2.75; p > 0.05). CONCLUSION: Due to the better results in the supraaortic/thoracic and abdominal/pelvic regions, the double injection protocol is preferred. However, both protocols require further improvement.

Adult↗

[Multislice computed tomographic myelography].

While magnetic resonance imaging (MRI) is the first line modality in depicting intramedullary spinal lesions, computed tomographic (CT) myelography has gained renewed attention due to the introduction of multislice scanning (MS-CT). Compared with conventional CT, MS-CT permits rapid, high-resolution imaging of various spinal pathologies with extended scan length. Although soft tissue contrast is inferior to that with MRI, MS-CT myelography performs best in detailed assessment of osseous pathologies, 3D imaging of orthopedic and anesthesiologic implants, and showing dural leakage and causes of CSF circulation impairment. Whenever MRI is not available or contraindicated, MS-CT myelography is the method of choice for evaluating spinal lesions.

Anatomy, Cross-Sectional↗

[Problems of hyomandibulopexia in patients with OSAS].

In cases of obstructive sleep apnea syndrome (OSAS) with intolerance of n-CPAP (nasal continuous positive airway pressure) treatment, hyoidthyroidpexia (synonym: hyoid suspension) has recently been advocated by some authors as a valuable surgical option. Despite a basically positive assessment, there is a risk of hindrance to the speaking and swallowing function. Moreover, the thyroid cartilage seems to be too weak for fixation of the hyoid with its complex muscular attachments. This reduces the likelihood of achieving positive long-term results. Considering aspects of preserving laryngeal function, we are reporting on 7 patients submitted to a hyomandibulopexia. This intervention counteracts the tendency of the tongue base to collapse by ventrolateral traction on the hypoglossal muscle via the severed greater horn of the hyoid. We have thus far had to correct our surgical procedure three times because of methodological problems in the postoperative phase. Specific problems with surgical materials like steel wire or Goretex are discussed. In conclusion, we explain why we consider a bone anchored Kevlar suture (FASTak of Arthrex) to be suitable for this operation. Considering functional aspects, our polysomnographic and phoniatric follow-up examinations point to a less traumatic surgical procedure with promising treatment results.

Bone Wires↗

[Virtual rendering techniques in otologic imaging].

UNLABELLED: Virtual postprocessing techniques combine the advantages of condensing the large amounts of data provided by high-resolution (HR) cross-sectional imaging modalities with those of three-dimensional (3D) imaging. The techniques and indications for virtual representations in imaging of the middle ear (ME), internal ear (IE), and cerebellopontine angle (CPA) are presented together with practical examples. MATERIAL AND METHODS: HR data sets acquired by computed tomography (CT) and magnetic resonance imaging (MRI) in patients with ME, IE, and CPA pathologies were transferred to a workstation via an internal network to generate endo- or extraluminal 3D views by means of the volume rendering technique (VRT). The source data were acquired using scanners and imaging protocols with the highest resolution available at present: a multislice spiral CT (MSCT) with a slice thickness of 0.5 mm and a reconstruction increment of 0.2 mm and a 3D CISS sequence with a slice thickness of 0.5 mm for MRI. RESULTS: Virtual endoscopy was superior to cross-sectional images for assessing ME pathologies like dysplasia, postoperative changes, and destructive bone processes with extensive soft-tissue involvement; fibrous obliterations of the internal ear and labyrinthine dysplasia were depicted with a superior image quality on 3D renderings compared to conventional reconstruction techniques. Virtual endoscopy of the CPA and external acoustic meatus (EAM) was helpful in detecting and visualizing neurovascular conflicts and in assigning small intrameatal tumors to components of the acousticofacial bundle. A common feature of all applications was that the large numbers of source images could be reduced to a few 3D reconstructions for documentation and optimized communication of the findings between the radiologist and otologist. CONCLUSION: Virtual rendering makes an important contribution towards establishing, presenting, and documenting the findings when certain otologic pathologies have to be assessed. It can be used for routine imaging and allows for more efficient handling of the large amounts of imaging data generated by high-resolution cross-sectional imaging modalities.

Cerebellopontine Angle↗

High-resolution petrous bone imaging using multi-slice computerized tomography.

Multi-slice computerized tomography (MSCT) is considered to provide superior image quality. We defined a data acquisition protocol for high-resolution (HR) temporal bone imaging using MSCT and assessed its impact on data acquisition and post-processing (PP). The data acquisition protocol was defined in cadaveric phantom studies performed by MSCT and subsequently applied to 38 patients referred for temporal bone assessment. The parameters image quality and diagnostic value of MSCT data were assessed for the cross-sectional source images as well as for 2-dimensional (2D) reformations and 3-dimensional (3D) reconstructions by 3 radiologists by comparison with incremental HR scans of 17 patients with suspected middle ear disorders. The data acquisition protocol yielded HR images with an excellent detail resolution and a comparable image quality of cross-sectional scans and related orthogonal reformations. MSCT achieved higher scores for image quality and diagnostic value (p < 0.001, t-test) than incremental HR CT with regard to both 2D and 3D reconstructions. MSCT improves the image quality of HR cross-sectional scans as well as that of 2D and 3D PP techniques in petrous bone imaging. The radiation exposure of the eye lenses is increased by MSCT as gantry angulation is not yet possible in the helical scan mode.

Algorithms↗

Virtual endoscopy of the tympanic cavity based on high-resolution multislice computed tomographic data.

OBJECTIVE: This study was designed to assess the value of high-resolution multislice computed tomography (MSCT) data of the petrous bone for the virtual endoscopic visualization of the tympanic cavity. BACKGROUND: The recently introduced MSCT technology has improved spatial resolution in the z axis as well as scan speed in computed tomography. Three-dimensional rendering of high-resolution MSCT data of the petrous bone may be expected to provide endoluminal views of superior image quality, thus competing with transtympanic endoscopy (otoendoscopy). SETTING: This study was conducted at a university teaching hospital. MATERIALS AND METHODS: Cadaveric phantom studies in a MSCT scanner were performed to define a data acquisition protocol, combining adequate detail resolution with low tube current. Subsequently, the cadaveric phantom underwent otoendoscopy. The postprocessing parameters of the three-dimensional rendering protocol were chosen to produce views closely resembling the corresponding otoendoscopic images. High-resolution data from 18 patients with pathologic conditions of the middle ear, as suggested by clinical findings and assessment of cross-sectional data, were postprocessed using the volume rendering technique to generate standardized virtual endoscopic views. A total of 36 virtual endoscopic scans of the tympanic cavity were generated. RESULTS: With regard to intermediate and high-density structures, virtual endoscopic images, based on MSCT data, yielded endoluminal views closely resembling corresponding otoendoscopic views. Virtual endoscopy seems useful for imaging ossicular pathologic conditions such as dysplasia and chain disruption as well as for assessing patient status before and after otosurgery. CONCLUSION: MSCT data sets allow for generating virtual endoscopic views closely resembling otoendoscopic images. The technique is especially useful when ossicular pathologic changes are present as well as for preoperative and postoperative imaging of otologic procedures.

Endoscopy↗

[Virtual otoscopy--technique, indications and initial experiences with multislice spiral CT].

UNLABELLED: We report the standardized postprocessing of high-resolution CT data acquired by incremental CT and multi-slice CT in patients with suspected middle ear disorders to generate three-dimensional endoluminal views known as virtual otoscopy. MATERIALS AND METHODS: Subsequent to the definition of a postprocessing protocol, standardized endoluminal views of the middle ear were generated according to their otological relevance. The HRCT data sets of 26 ENT patients were transferred to a workstation and postprocessed to 52 virtual otoscopies. RESULTS: Generation of predefined endoluminal views from the HRCT data sets was possible in all patients. Virtual endoscopic views added meaningful information to the primary cross-sectional data in patients suffering from ossicular pathology, having contraindications for invasive tympanic endoscopy or being assessed for surgery of the tympanic cavity. Multi slice CT improved the visualization of subtle anatomic details such as the stapes suprastructure and reduced the scanning time. CONCLUSION: Virtual endoscopy allows for the non invasive endoluminal visualization of various tympanic lesions. Use of the multi-slice CT technique reduces the scanning time and improves image quality in terms of detail resolution.

Adolescent↗