Search PubMed⌕ Search

Biomedical subjects

H Burnett

Publications and source records attributed to H Burnett.

4 recordsLinked to original sources

Pseudosubluxation of C2 on C3 in polytraumatized children--prevalence and significance.

AIM: Pseudosubluxation of C2 on C3 is a recognized physiological variant in the upper cervical spine radiographs of normal children. The aim of this study was to determine the prevalence of this variant in children admitted with serious polytrauma, and to explore its significance in this setting. PATIENTS AND METHODS: A retrospective review was performed of 138 patients under 16 years of age admitted with polytrauma via The Helicopter Emergency Medical Service. All patients wore hard collars and underwent immediate horizontal beam lateral cervical spine radiography. Normal and C2/C3 pseudosubluxation groups were defined using standard criteria. The two groups were compared in terms of age, presence of an endotracheal tube, injury severity, and outcome. RESULTS: There were 108 (78.3%) children in the normal group and 30 (21.7%) in the C2/C3 pseudosubluxation group. No significant differences in sex ratio, intubation status, injury severity, or outcome were found. Patients in the pseudosubluxation group were significantly younger. CONCLUSION: In paediatric polytrauma it is essential to establish the integrity of the cervical spine promptly as this will deter unnecessary further imaging and investigation. In our study 21.7% of cases had C2/C3 pseudosubluxation on admission radiographs. We have shown that C2/C3 pseudosubluxation has no significant association with intubation status, injury severity, or outcome. We conclude that C2/C3 pseudosubluxation can be considered a benign variant even in the setting of polytrauma.

Adolescent↗

The effect of silicone ocular surgical devices on serum IgG binding to silicones.

PURPOSE: To determine whether silicone materials used in retinal detachment repair and cataract surgery increase serum IgG binding to silicone and identify correlations with complications of ocular surgery. METHODS: Serum from 49 patients who had ocular surgery using silicone materials was examined. Patient groups included scleral buckling (n = 25), silicone oil tamponade (n = 3), scleral buckling and silicone oil tamponade (n = 9), and silicone lens implants after cataract extraction (n = 12). Convalescent samples for all patients and preoperative samples from 19 patients (18 scleral buckling and one silicone oil tamponade) were examined. Postoperative complications were monitored for up to 108 months (mean, 10.7 months; mode, 1.5 months; range, 1 to 108 months). Samples were evaluated for the extent of IgG binding to silicones using a micromodification of a previously described enzyme-linked immunosorbent assay method. RESULTS: In 19 patients, IgG binding levels in preoperative samples were 21 arbitrary units (AU) or less. Of the 25 buckling patients, one developed complications; however, in all patients the postoperative levels of IgG binding to silicone were low (2.2 to 20.0 AU). Although four silicone lens patients developed mild complications, none displayed postoperative IgG binding levels of greater than 20 AU. Three patients who underwent both scleral buckling and silicone oil tamponade developed complications; one of these patients, who was also noted to have systemic connective tissue disease, had a significant elevation in postoperative serum IgG binding to silicone. CONCLUSIONS: Statistically significant elevations of serum IgG binding to silicone were noted postoperatively in only one patient who had a systemic connective tissue disease. The complication rate and frequency of enhanced serum IgG binding to silicone was low, making correlations to surgical complications difficult. Examination of matched samples suggested that if ocular exposure to silicone implants enhances the level of serum IgG binding to silicones, it must be a rare event that should not alter the clinical use of these important devices.

Adult↗

The occurrence and distribution of certain polypeptides within the human carotid body.

Both carotid bodies from 26 patients coming to necropsy were fixed in 10% neutral buffered formalin and sections 4 microns thick were stained for various peptides by use of the immunogold technique. The results show that the human carotid body contains met- and leu-enkephalin, substance P, vasoactive intestinal peptide (VIP), neurotensin and bombesin. The distribution of these six peptides within the carotid body differs. Thus met- and leu-enkephalin are both present predominantly within glomic chief cells but with a marked tendency to favour the dark variant of these cells. Substance P and VIP both show a weak immunoreactivity in comparison to the enkephalins and are present in all three variants of chief cell. Neurotensin shows the weakest immunoreactivity of all and is restricted to a few glomic chief cells in a minority of cases. Bombesin also shows a weak immunoreactivity in glomic chief cells but a strong reaction in glomic arteries and arterioles. In these vessels bombesin appears to be confined to smooth muscle cells in the media but we cannot say whether it is secreted by them or merely bound to receptor sites on their membranes. These findings are related to quantitative data on the concentration of peptides in the human carotid body from a previous paper with which we were associated.

Bombesin↗