Search PubMed⌕ Search

Biomedical subjects

H Bosmans

Publications and source records attributed to H Bosmans.

74 records · Page 5Linked to original sources

Factors influencing the accuracy of volume measurements in spiral CT: a phantom study.

PURPOSE: The purpose of this study was to investigate the influence of different parameters (object size, shape, orientation, contrast, observer, and window setting) on the accuracy of volume measurements in spiral CT. METHOD: The phantom study consisted of two parts. First, well-circumscribed ellipsoid objects were scanned with conventional and spiral CT. Volumes were determined by two observers using manual contour delineation and summation-of-areas. The influence of object size, CT technique, and observer was assessed. Second, irregularly shaped gingerroots were scanned and the effect of observer, contrast, and orientation was investigated. Also assessed in both parts of the study was the effect of window setting. RESULTS: Spiral CT offered higher accuracy and reproducibility than conventional CT did. The accuracy of volume measurements was mainly determined by the window setting used for image display. Using an "optimized" window center value halfway between object density and background density resulted in overestimation of true object volumes if the number of slices through the object (number of samples) was low. Other factors (contrast, observer-related errors in contour delineation) were less important. CONCLUSIONS: Volume measurements of small objects, obtained with spiral CT and using manual contour delineation, may be grossly erroneous. Major causes of inaccuracy are an inappropriate window center selection and undersampling.

Phantoms, Imaging↗

Functional recovery of subepicardial myocardial tissue in transmural myocardial infarction after successful reperfusion: an important contribution to the improvement of regional and global left ventricular function.

BACKGROUND: The transmural extent of myocardial necrosis after an acute coronary artery occlusion can vary considerably. The contribution of residual subepicardial viable myocardium to global left ventricular function is largely unknown. METHODS AND RESULTS: We studied 12 patients with single-vessel disease 1 week after successful reperfusion of a first transmural anterior myocardial infarction (MI). With PET, myocardial blood flow (MBF) and glucose metabolism were measured regionally, and the viability was graded as normal, mismatch, or match with severely (<50% of normal) or intermediately (50% to 80% of normal) impaired MBF. Magnetic resonance tagging was used to regionally quantify fiber strains, wall thickening, and ejection fraction in patients 1 week and 3 months after the MI and in age-matched healthy volunteers. From 1 week to 3 months, subepicardial fiber shortening improved significantly in the match region (MBF <50%, -5.1+/-7.0% to -9.9+/-8. 7%; MBF of 50% to 80%, -7.1+/-7.6% to -14.9+/-7.9%). This was associated with an improvement in regional ejection fraction in the infarcted myocardium (29.6+/-21.8% to 43.5+/-15.5%, P<0.0001) and in normal regions (54.3+/-15.1% to 56.5+/-13.1%, P=0.013), contributing to an increase in global ejection fraction from 44.2+/-22.2% to 49. 3+/-17.9% (P<0.0001). CONCLUSIONS: Functional recovery of viable subepicardial regions is a mechanism of late improvement in regional and global ejection fraction after a so-called transmural MI.

Aged↗