Search PubMed⌕ Search

Biomedical subjects

H Bliddal

Publications and source records attributed to H Bliddal.

At least 19 recordsLinked to original sources

Ultrasound guided electrocoagulation in patients with chronic non-insertional Achilles tendinopathy: a pilot study.

BACKGROUND: High resolution colour Doppler ultrasound shows intratendinous Doppler activity in patients with chronic Achilles tendinopathy. Treatment of this neovascularisation with sclerosing therapy seems to relieve the pain. However, the procedure often has to be repeated. OBJECTIVE: To investigate the effect of electrocoagulation of the neovessels on tendon pain and tendon vascularity in patients with chronic Achilles tendinopathy. METHODS: Colour Doppler ultrasound guided electrocoagulation was used on vessels in the ventral portion of the Achilles tendon in 11 patients (seven men, four women, mean age 41 years) with painful chronic mid-portion Achilles tendinosis. A unipolar coagulation device was used. RESULTS: One patient dropped out after two months (dissatisfied with the results). The remaining 10 patients (91%) were satisfied. These 10 patients were still satisfied at six months of follow up and had returned to their previous level of activity. All 10 patients were "cured" after one treatment. The patient who dropped out received two treatments because of lack of progress. There was significantly reduced pain (Likert pain scale, 0-10) during activity, from a median of 7 (range 4 to 10) at baseline to 0 (0 to 8) at six months' follow up (p<0.005); and at rest, from 1.5 (1 to 5) to 0 (0 to 8) (p = 0.005). In all patients, vascularisation was unchanged at the six months follow up, with no significant change in semiquantitative or quantitative colour scoring. CONCLUSIONS: Coagulation in the area with vessels entering the tendon appears to be effective treatment for painful chronic mid-tendinous Achilles tendinopathy. No effect on the intratendinous Doppler activity could be detected, suggesting that the effect is independent of changes in blood flow. Localisation of hyperaemia appears to be the key to the pathology and for targeting the treatment. One explanation could be that the effect is obtained by destruction of nerves accompanying the vessels.

Achilles Tendon↗

Reproducibility and inter-reader agreement of a scoring system for ultrasound evaluation of hip osteoarthritis.

OBJECTIVE: To evaluate the intra-reader and inter-reader agreements of ultrasonographic assessments of hip joints in patients with hip osteoarthritis. DESIGN: Ultrasonography was performed on 100 patients with hip osteoarthritis at 14 MHz using a 8-15 MHz linear probe. Dynamic sweeps of the hip and representative still images were used for the analysis. A semiquantitative grading score was introduced in the evaluation of the ultrasound pictures and compared with an overall ultrasound evaluation. The evaluation was performed by a specialist in ultrasonography and a rheumatologist trained in musculoskeletal ultrasound examination. Clinical pain assessment and joint aspiration were obtained in parallel with the ultrasonography. RESULTS: Intraobserver agreement represented by intraclass correlation coefficients (ICC) (exact agreement in percentage; unweighted kappa values) showed good to excellent correlation, 0.8 with regard to the osteophyte score, 0.78 with regard to the femoral head score, 0.71 with regard to the fluid score and 0.69 with regard to the synovial profile score. Interobserver agreement was fair to good with corresponding ICC 0.65, 0.63, 0.45 and 0.6, respectively. In comparison, the ICC for the global osteoarthritis and synovial assessments were 0.7 and 0.72, respectively, for the intraobserver rating and 0.56 and 0.58, respectively, for the interobserver rating. CONCLUSIONS: This study suggests that ultrasound is a reproducible method for the assessment of changes in the osseous surface and synovium-related inflammation. The semiquantitative scoring system presented seemed to match the global assessment of a trained ultrasound investigator and might be used by less-trained investigators.

Adult↗

Ultrasound Doppler of the Achilles tendon before and after injection of an ultrasound contrast agent--findings in asymptomatic subjects.

UNLABELLED: The sensitivity of ultrasound Doppler has now reached a level at which perfusion can be detected even in normal, resting musculoskeletal tissues. To be able to distinguish normal from abnormal flow, the resistive index (RI) determined by spectral Doppler may be of value. Inflammation is associated with low RI values and a value of 1.00 is normal. PURPOSE: In tissues with no detectable flow, it has been assumed that RI may be defined as 1.00. This study was performed to test if normal tendinous vessels could be visualised with a contrast agent, and if such vessels had normal RI. MATERIALS AND METHODS: Ultrasound (US) was performed with a 14 MHz linear transducer. 22 asymptomatic tendons in 12 subjects were scanned, and only 5 ultrasonically normal tendons in 5 subjects were identified. In these 5 normal tendons, SonoVue was used to make vessels visible. The Achilles tendons and the peritendinous tissues were evaluated clinically. RESULTS: In all 5 ultrasonically normal tendons, arteries could be detected with Doppler after contrast injection and in all cases with normal RI values. All vessels were located in the mid-portion of the tendon. 18 tendons were categorised as normal by the clinician. CONCLUSION: After administration of a contrast agent, all Achilles tendons could be demonstrated to have arteries present in the mid-portion. The flow profile of these arteries was fully normal without diastolic component and with an RI of 1.00. This finding has implications for criteria of normality of tendons, which cannot be based exclusively on the presence or absence of Doppler activity. The majority of the tendons in this study had ultrasound abnormalities both on gray-scale and colour Doppler. It can be speculated that the abnormalities may be age-related degenerative changes and that age-stratified normal materials are needed to define normality. There was no consistency between US and clinical diagnosis.

Achilles Tendon↗

Intra-tendinous ossification with concomitant tendonitis and bursitis--ultrasound grey-scale and colour Doppler findings.

A case report of a 62-year-old man with a 20-year history of tendon problems, who presented with a swollen and tender left Achilles tendon. Ultrasound (US) revealed a 2 x 1 x 0.9 cm intra-tendinous substance with acoustic shadowing. On a radiogram, ossification was found. Colour Doppler activity was present in both the bursa and the tendon. A US-guided injection of 40 mg Depomedrol was applied into the retrocalcaneal bursa. On follow-up two months later, the patient had no symptoms and US showed total regression of Doppler activity. The ossification was unchanged. US colour Doppler may be recommended for guidance and monitoring of treatment.

Bursitis↗

Indications of inflammation visualized by ultrasound in osteoarthritis of the knee.

PURPOSE: Ultrasound examination of a group of patients with osteoarthritis (OA) of the knee for signs of inflammation. MATERIAL AND METHODS: 71 knees in 71 patients with osteoarthritis of the knee were examined with high-resolution gray-scale ultrasound combined with color and spectral Doppler. The medial, lateral, and antero-superior compartments were examined. Hyperemia was identified as presence of color Doppler signals in the synovial membrane. Low resistance flow was defined as a resistive index < 0.80 on spectral Doppler. RESULTS: Synovial thickening was found in all knees; fluid in 61 patients; and hyperemia (color Doppler activity) in 51 patients. Of these, 44 had arterial flow on spectral Doppler - 36 with a low resistance flow. When present, fluid and color Doppler activity was found in all three compartments, but with uneven distribution. CONCLUSION: The finding in the majority of cases of both effusions on B-mode US and Doppler activity confirms that there is a varying degree of inflammation in knee OA as diagnosed by the ACR criteria.

Adult↗

Delayed gadolinium-enhanced magnetic resonance imaging (dGEMRIC) of hip joint cartilage: better cartilage delineation after intra-articular than intravenous gadolinium injection.

PURPOSE: To investigate and compare delayed gadolinium (Gd-DTPA)-enhanced magnetic resonance imaging (MRI) of cartilage (dGEMRIC) in the hip joint using intravenous (i.v.) or ultrasound-guided intra-articular (i.a.) Gd-DTPA injection. MATERIAL AND METHODS: In 10 patients (50% males, mean age 58 years) with clinical and radiographic hip osteoarthritis (OA; Kellgren score II-III), MRI of the hip was performed twice on a clinical 1.5T MR scanner: On day 1, before and 90-180 min after 0.3 mmol/kg body weight i.v. Gd-DTPA and, on day 8, 90-180 min after ultrasound-guided i.a. injection of a 4 mmol/l Gd-DTPA solution. Coronal STIR, coronal T1 fat-saturated spin-echo, and a cartilage-sensitive gradient-echo sequence (3D T1 SPGR) in the sagittal plane were applied. RESULTS Both the post-i.v. and post-i.a. Gd-DTPA images showed significantly higher signal-to-noise (SNR) and contrast-to-noise (CNR) in the joint cartilage compared to the non-enhanced images (P < 0.002). I.a. Gd-DTPA provided significantly higher SNR and CNR compared to i.v. Gd-DTPA (P < 0.01). Furthermore, a better delineation of the cartilage in the synovial/cartilage zone and of the chondral/subchondral border was observed. CONCLUSION: The dGEMRIC MRI method markedly improved delineation of hip joint cartilage compared to non-enhanced MRI. The i.a. Gd-DTPA provided the best cartilage delineation. dGEMRIC is a clinically applicable MRI method that may improve identification of early subtle cartilage damage and the accuracy of volume measurements of hip joint cartilage.

Adult↗

The management of osteoarthritis in the obese patient: practical considerations and guidelines for therapy.

Obesity and osteoarthritis (OA) co-exist in an increasing part of the population. The two diseases intertwine in several ways. The evolution in the population shows a tendency towards deterioration of both by increasing general age and weight. The two diseases share pathogenetic features and the development of one disease increases the risk of the other and may be the onset of a vicious circle. There is a link between treatments of these two diseases as well. There is now solid (gold) evidence that by treating effectively the obesity of patients with co-occurring OA, the functional status is dramatically ameliorated; the short-term results are equal to that of a joint replacement. The long-term efficacy of a weight loss remains to be shown. OA is definitely one of many diseases in which obesity must be taken seriously into account when planning a correct treatment of patients. The regimens used in the controlled studies of such patients are reviewed and it may be concluded that practical aspects of the dietary intervention in obese patients with OA are not different from general recommendations.

Comorbidity↗

Tendinopathy and Doppler activity: the vascular response of the Achilles tendon to exercise.

BACKGROUND: Intratendinous Doppler activity has been interpreted as an equivalent of neovessels in the Achilles tendon and as a sign of tendinosis (AT). AIM: To evaluate the vascular response as indicated by color Doppler activity after repeated loading of both symptomatic and non-symptomatic Achilles tendons. MATERIAL AND METHODS: Ten non-trained, healthy subjects ran 5 km. Ultrasound (US) Doppler activity was determined before and after the exercise. Eleven patients with chronic AT performed 3 x 15 heavy-load eccentric exercise. The Achilles tendons were scanned before and immediately after the exercise. RESULTS: Non-symptomatic: six Achilles tendons in five subjects had intratendinous Doppler activity before the exercise. All but two subjects (80%) had intratendinous Doppler activity after running. Symptomatic: all patients had Doppler activity in the tendons, with a median color fraction before eccentric exercise of 0.05 (range 0.01-0.33). The Doppler activity did not disappear after exercise. Tendons with a color fraction below the median at baseline increased significantly after the exercise (P=0.02). CONCLUSION: The mere presence of Doppler in the Achilles tendon does not per se indicate disease. Eccentric exercise does not extinguish the flow during or after one training session in patients with chronic AT.

Achilles Tendon↗

Intra-articular treatment of hip osteoarthritis: a randomized trial of hyaluronic acid, corticosteroid, and isotonic saline.

OBJECTIVE: Hyaluronic acid (HA) and corticosteroids are both widely used for intra-articular treatment of knee osteoarthritis (OA). We examined the effect of both drugs in intra-articular treatment for hip OA. METHODS: One hundred and one patients with hip OA were included in a prospective double blind study, using a randomized controlled trial with a three-armed parallel-group design. Three ultrasound-guided, intra-articular injections were given at 14 days interval. The primary outcome measure was 'pain on walking', registered on a visual analogue scale (VAS). Evaluation was performed at baseline and after 14, 28 and 90 days. The study adhered to the Consolidated Standards of Reporting Trials. All analyses were based on intention-to-treat analyses, and used 'mixed-procedures' with the baseline-observation as covariate. RESULTS: There were no significant interactions with respect to Treatment x Time for any of the analyzed outcome measures. There was a significant treatment effect for 'pain on walking' (P=0.044) due to a significant improvement following corticosteroid compared to saline with an effect-size of 0.6 (95% confidence interval: 0.1-1.1, P=0.021). By contrast, HA compared to saline had an effect size of 0.4 (-0.1 to 0.9; P=0.13). The peak-effect was obtained after 2 weeks. There was no difference between the treatment groups at endpoint. No significant side effects of the injections were observed. CONCLUSIONS: Patients treated with corticosteroids experienced significant improvement during the 3 months of intervention, with an effect size indicating a moderate clinical effect. Although a similar significant result following treatment with HA could not be shown, the effect size indicated a small clinical improvement. A higher number of patients in future HA studies would serve to clarify this point.

Adjuvants, Immunologic↗

Weight loss: the treatment of choice for knee osteoarthritis? A randomized trial.

OBJECTIVE: We wanted to assess the effect of rapid diet-induced weight loss on the function of obese, knee osteoarthritis (OA) patients. METHODS: Eighty patients with knee OA, 89% women (n=71), were recruited. Mean (SD) body-mass index (BMI) was 35.9 (5.1) kg/m(2) and age 62.6 (11.1) years. Patients were randomized to either a low-energy diet (LED 3.4MJ/day), or a control diet (5MJ/day). The LED group had weekly dietary sessions, whereas the control group was given a booklet describing weight loss practices. Changes in body weight and body composition were examined as independent predictors of changes in knee OA symptoms. Symptoms were monitored by the Western Ontario and McMaster Universities' (WOMAC) OA index. RESULTS: The LED and control group lost a mean (SE) of 11.1 (0.6)% and 4.3 (0.6)%, respectively, with a mean difference being 6.8% (95% confidence interval (CI): 5.5 to 8.1%; P<0.0001). The decrease in body fat percent was higher in the LED group, 2.2% (1.5 to 3.0%; P<0.0001). The total WOMAC index improved in the LED group (P<0.0001), but not in the control group (P=0.12), mean difference: -219.3mm (-369.2 to -69.4mm; P=0.005). The 'Number Needed to Treat (NNT)' to ensure an improvement in WOMAC>/=50% was 3.4 (2.1 to 8.8) patients. Changes in total WOMAC index were best predicted by the reduction of body fat percent, with a 9.4% (4.8 to 13.9%) improvement in WOMAC for each percent of body fat reduced (P=0.0005). CONCLUSIONS: In our patients with knee OA, a weight reduction of 10% improved function by 28%. LED might be of advantage to control diet because of the rapidity of weight loss and a more significant loss of body fat.

Adipose Tissue↗

Learning effect of isokinetic measurements in healthy subjects, and reliability and comparability of Biodex and Lido dynamometers.

The aim of this study was to examine the learning effect during a set of isokinetic measurements, to evaluate the reliability of the Biodex System 3 PRO dynamometer, and to compare the Biodex System 3 PRO and the Lido Active dynamometers on both extension and flexion over the elbow and the knee at 60 degrees s(-1). Thirteen (nine women, four men) healthy participants were measured five times using the Biodex and once using the Lido dynamometer. The intervals between the first four tests were 20 min, and 1 week between tests 4 and 5. Between Biodex and Lido measurements there was a 20 min time interval. When comparing the first five measurements (Biodex), no systematic effect over time and an excellent reliability were found with respect to elbow and knee flexion and extension. No difference in muscle strength (Nm) between the Biodex and Lido was observed for knee flexion (P = 0.59), knee extension (P = 0.18) and elbow extension (P = 0.63). However, elbow flexion showed a 14.8% (95% CI: 11.2-18.4%; P = 0.0001) higher peak torque on Biodex. In conclusion, no learning effect was observed and the Biodex proved to be a highly reliable isokinetic dynamometer. A difference was observed when comparing Biodex and Lido on elbow flexion, but the difference did not outrange the expected variation found with a typical isokinetic measurement, which is why both sets of equipment seem applicable in clinical practice.

Adolescent↗

Doppler ultrasound findings in healthy wrists and finger joints before and after use of two different contrast agents.

OBJECTIVE: To examine the effect of contrast agents on Doppler ultrasound findings in the synovial membrane in the wrist and fingers of healthy volunteers. MATERIALS AND METHODS: Eleven healthy subjects were included in the study (5 women and 6 men, mean age 38 years, range (20-60)). They had no clinical signs of inflammatory or degenerative joint diseases. A total of 66 joints were examined-6 joints for each subject: wrist and metacarpophalangeal (MCP) joints 1-5-before contrast injection and after Levovist and SonoVue injection with a 30 minute interval. RESULTS: Colour Doppler activity was detected in 10/55 (18%) MCP joints before contrast injection and in 29/55 (53%) and 28/55 (51%) joints after Levovist (p<0.0001) and SonoVue injection (p = 0.0001), respectively. A significant increase in Doppler activity in the radial (p<0.05) and ulnar (p = 0.01) parts of the wrist joint was detected only after SonoVue injections. With spectral Doppler no difference was found in the resistive index (RI) in the vessels measured before as compared with those only detected after contrast injection. CONCLUSION: The number of joints with colour Doppler activity in healthy volunteers was increased by the use of contrast agents. No changes in RI were detected. The value of contrast agents remains to be demonstrated in inflammatory diagnostics.

Adult↗

Effect of static stretching of quadriceps and hamstring muscles on knee joint position sense.

OBJECTIVES: To evaluate if a stretch regimen consisting of three 30 second stretches would alter joint position sense (JPS). METHODS: A blinded, randomised, cross over design with a washout time of 24 hours was used with 20 healthy volunteers. JPS was estimated from the ability to reproduce the same position in one knee (target versus estimated angle) expressed as the difference between target and estimated angle (constant error, CE). Measurements were repeated three times in a sitting and a prone position on the dominant leg measured before and immediately after the static stretch. The static stretch consisted of a 30 second stretch followed by a 30 second pause, repeated three times. RESULTS: At baseline, the mean (SD) CE was -2.71 (3.57) degrees in the sitting position. No difference (p = 0.99) in CE between stretching and control was observed (0.00; 95% confidence interval -0.98 to 0.99). At baseline, the CE was -3.28 (4.81) degrees in the prone position. No difference (p = 0.89) in CE between stretching and control was observed (0.12; 95% confidence interval -1.52 to 1.76). CONCLUSION: A static stretch regimen had no effect on JPS in healthy volunteers.

Adult↗

Collagen structure in skin from fibromyalgia patients.

The distribution and amount of collagen in skin from a non-tender-point area from fibromyalgia patients was assessed by quantitative analysis of amino acids and by electron and light microscopy. Skin biopsies were obtained from the front of the thigh of 27 females who fulfilled the American College of Rheumatology criteria of fibromyalgia and from eight control subjects who were matched for gender, age and physical activity. Amino acids were determined by high-performance liquid chromatography. Electron and light microscopic investigations were carried out to examine tissue structure. Among the collagen-related amino acids, the mean number of hydroxyproline residues per 1,000 residues was 52.5 and 63.4 in fibromyalgia patients and control subjects, respectively (p = 0.050); proline residues were 81.7 and 110.0 (p = 0.006); and hydroxylysine residues were 14.7 and 10.1 (p = 0.002). The total amount of skin protein in proportion to dry tissue weight was 83.4% and 72.6% in fibromyalgia and controls, respectively (p = 0.037). The overall microscopic picture was normal. The lamellar structure of the perineurium and a deficiency in collagen packing in the endoneurium was observed more frequently and to a larger extent in fibromyalgia patients than in controls. In conclusion, there are some differences between the amino acid composition of skin proteins in fibromyalgia patients compared with controls. The amount of collagen may be lower in skin from fibromyalgia patients, and collagen packing in the endoneurium may be less dense.

Amino Acids↗

Lumiracoxib is effective in the treatment of osteoarthritis of the knee: a 13 week, randomised, double blind study versus placebo and celecoxib.

OBJECTIVES: To compare the efficacy and safety of lumiracoxib with placebo and celecoxib for osteoarthritis OA in a 13 week, multicentre, randomised, double blind study. METHODS: After a 37 day washout period for nonsteroidal antiinflammatory drugs, 1702 patients with knee OA were randomised to lumiracoxib 200 or 400 mg once daily od, celecoxib 200 mg od, or placebo 2221. A visual analogue scale VAS pain intensity > or =40 mm was required. Primary efficacy variables were OA pain intensity VAS mm in the target knee, patients global assessment of disease activity VAS mm, and WOMAC pain subscale and total scores at 13 weeks. OA pain intensity, patients and physicians global assessment of disease activity, and WOMAC total and all subscale scores were analysed by visit as secondary variables. RESULTS: Lumiracoxib showed significant improvements in all primary and secondary variables compared with placebo. Lumiracoxib 200 mg od and celecoxib 200 mg od achieved similar improvements in OA pain intensity and functional status. Lumiracoxib 400 mg od demonstrated better efficacy for OA pain intensity and patients global assessment of disease activity at weeks 2, 4, and 8 and similar efficacy at week 13 compared with celecoxib 200 mg od. The incidence of adverse events AEs, serious AEs, and discontinuations due to AEs was similar in each group. CONCLUSION: Lumiracoxib demonstrated significant improvement in OA pain intensity, patients global assessment of disease activity, and the WOMAC pain subscale and total scores compared with placebo. Lumiracoxib was well tolerated in this study, with overall tolerability similar to that of placebo and celecoxib.

Adult↗

The effect of calcium and vitamin D3 supplementation on the healing of the proximal humerus fracture: a randomized placebo-controlled study.

The purpose of this study was to (1) quantify the healing process of the human osteoporotic proximal humerus fracture (PHF) expressed in terms of callus formation over the fracture region using BMD scanning, and (2) quantify the impact of medical intervention with vitamin D3 and calcium on the healing process of the human osteoporotic fracture. The conservatively treated PHF was chosen in order to follow the genuine fracture healing without influence of osteosynthetic materials or casts. Thirty women (mean age = 78 years; range = 58-88) with a PHF, osteoporosis or osteopenia (based on a hip scan, WHO criteria), and not taking any drugs related to bone formation, including calcium or vitamin D supplementation, were randomly assigned to either oral 800 IU vitamin D3 plus 1 g calcium or placebo, in a double-blind prospective study. We measured biochemical, radiographic, and bone mineral density effect parameters to evaluate the impact on the healing process. Scanning procedures of the fractured shoulder included use of a fixation device to obtain the highest possible precision. Double scans of the fractured shoulder revealed a coefficient of variation (CV) on BMD measurements that improved from 2.8% immediately after fracture occurrence to 1.7% at 12 weeks (P = 0.003) approaching the 1.2% levels observed over the healthy shoulder. BMD was similar in the two groups at baseline (active 0.534 g/cm2 vs. placebo 0.518 g/cm2), and both increased over the 12-week observation period, with peak levels in week 6. By week 6 BMD levels were higher in the active group (0.623 g/cm2) compared with the placebo group (0.570 g/cm2, P = 0.006). Thirty seven percent of the patients presented with vitamin D levels below 30 nmol/l, indicative of mild vitamin D insufficiency. In conclusion, we have demonstrated that it is possible to quantify callus formation of the PHF with sufficiently high precision to demonstrate the positive influence of vitamin D3 and calcium over the first 6 weeks after fracture. Whether this results in more stable fractures, extends to other fracture types, or applies to other osteogenic bone agents such as bisphosphonates remains to be examined.

Absorptiometry, Photon↗

Test-retest reliability of trunk accelerometric gait analysis.

The purpose of this study was to determine the test-retest reliability of a trunk accelerometric gait analysis in healthy subjects. Accelerations were measured during walking using a triaxial accelerometer mounted on the lumbar spine of the subjects. Six men and 14 women (mean age 35.2; range 18-57) underwent the same protocol on 2 consecutive days. The raw acceleration signals from six self-selected walking speeds were transformed into a horizontal-vertical coordinate system to remove unwanted variability caused by gravity. Acceleration root mean square values, cadences, step and stride lengths were then computed and interpolated using quadratic curve fits and point estimates were calculated at a standardised walking speed of 1.35 m/s. Relative reliability was determined using two models of intraclass correlation coefficients (ICC(1,1) and ICC(3,1)) to assess any systematic shifts and absolute reliability was determined using measurement error (ME). The results of the study showed high ICC values (0.77-0.96) and ME values of 0.007-0.01 g for mean acceleration; 0.009 m for step lengths; 0.022 m for stride length and 1.644 step/min for cadences. In conclusion, the method was found to be reliable and may have a definite potential in clinical gait analysis.

Adolescent↗

Preliminary results of colour Doppler-guided intratendinous glucocorticoid injection for Achilles tendonitis in five patients.

BACKGROUND: It is debated as to whether Achilles tendonitis (AT) has an inflammatory component. The intratendinous hyperaemia demonstrated with colour Doppler has been interpreted as neovascularisation. Glucocorticoid injection around the tendon is a common therapeutic procedure. HYPOTHESES: The intratendinous hyperaemia seen with ultrasound (US) colour Doppler represents an inflammatory background. Glucocorticoid injections will be effective if administered inside the tendon where the inflammation seems to be. STUDY DESIGN: An uncontrolled, prospective study with a minimum follow-up of 3 months. METHODS: Six tendons in five patients were evaluated with grey-scale US and colour Doppler before and after US-guided intratendinous glucocorticoid injection. Pain at rest and at activity was evaluated on a visual analogue scale. RESULTS: With colour Doppler all tendons had intratendinous flow. Pain and colour Doppler activity decreased during a mean follow-up of 182 days (range 92-309 days). One tendon relapsed after 199 days. CONCLUSION: Intratendinous glucocorticoid injections seem to have a marked effect on both symptoms and colour Doppler findings, which may be taken as an indication of an inflammatory component in the disease. Colour Doppler adds significant information to grey-scale US with regard to diagnosis, location and follow-up of AT.

Achilles Tendon↗