Delivery of inhaled medication to children.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to H Bisgaard.
Explore the source record for details and available documents.
Inhaled corticosteroids reduce asthma symptoms and exacerbations, improve lung function, and reduce airway inflammation and bronchial hyperreactivity more effectively than other treatments. However, inhaled corticosteroids may be unable to return lung function and bronchial hyperreactivity to normal when introduced for moderately severe asthma. This finding highlights the need to improve treatment strategy in pediatric asthma. The natural progression of persistent asthma may lead to loss of lung function and chronic bronchial hyperreactivity for children and adults. There is evidence to suggest that asthma acts via a chronic inflammatory process that causes remodeling of the airways with mucosal thickening and smooth muscle hypertrophy. An optimal treatment strategy would be one aimed at reducing the ongoing airway inflammation. Inhaled steroids ameliorate the inflammation, whereas this has not been documented for any other treatment. Delayed introduction of inhaled steroids appears to result in reduced improvement in lung function compared with the early use of inhaled steroids. This improved response from the earlier use of inhaled steroids appears to be valid at any stage of the disease. Therefore, a change in treatment strategy toward earlier introduction of corticosteroids may impede airway remodeling, bronchial hyperreactivity, and airway damage. No other treatment has been found to affect the course of the disease. Systemic side-effects, particularly inhibition of growth in asthmatic children using inhaled corticosteroids, do not seem to be cause for concern. Growth retardation has not been reported when inhaled corticosteroid doses of < or = 400 micrograms daily are individually tailored to each child's needs. The ongoing change in treatment strategy toward the earlier use of inhaled steroids in childhood asthma, as reflected in current revisions of various treatment strategies, therefore seems well founded.
Explore the source record for details and available documents.
This study evaluated three techniques for testing of lung function in young awake children. We compared measurements by the forced or impulse oscillation technique (IOS), the interrupter technique (IT), and transcutaneous measurements of oxygen (tcPo2) with concomitant measurements of specific airway resistance (sRaw) during methacholine challenge in 20 stable asthmatic children, 2-4 years old. Measurements were performed with all techniques after each dose of methacholine and after inhalation of a bronchodilator. Measurements were carried out during tidal breathing using a face-mask with a built-in mouthpiece. The ranking of sensitivity was as follows: sRaw > IOS, respiratory reactance at 5 Hz (Xrs5) > tcPo2 > interrupter resistance (Rint) > IOS, respiratory resistance at 5 Hz (Rrs5). The sensitivity of sRaw and Xrs5 was not significantly different, but both were significantly more sensitive than Rint and Rrs5; the sensitivity of tcPo2, Rint, and Rrs5 was not significantly different. Measurements in eight of the subjects performed during an episode of acute asthma yielded comparable results in regard to the sensitivity of the techniques. Measurements improved significantly after bronchodilator administration; however, the response to bronchodilator tended to be less during acute asthma and was best demonstrated by a deterioration of tcPo2. All the evaluated techniques reliably reflect short-term changes in respiratory function and can provide clinically useful estimates of airway function. The techniques are non-invasive, are not dependent on the active co-operation or sedation of the subjects, and therefore are well suited for routine use in young children.
Explore the source record for details and available documents.
The aim of this study was to evaluate the effect and tolerability of formoterol 12 micrograms on exercise-induced asthma in children for 12 h as compared to the effect of salbutamol 400 micrograms and placebo. The drugs were inhaled as dry powder from a flow-dependent metered-dose inhaler (DP-MDI). Sixteen asthmatic children took part in a double-blind placebo-controlled within-patient single-centre trial. On each study day the patients were given one of the drugs or placebo in random order, and standardized exercise tests were performed after 3 and 12 h. At a pretrial test the children had demonstrated a median maximum percentage fall of 38% (range 22-79%) in forced expiratory volume in 1 s after exercise challenge. Formoterol showed a median percentage protection of 77% and 70% at 3 and 12 h postexercise, respectively, as compared to 46% and 13% with salbutamol. No side-effects were observed. Formoterol 12 micrograms administered as dry powder offers significantly better protection against exercise-induced asthma after 3 and 12 h as compared to salbutamol 400 micrograms and placebo.
Longitudinal data were analysed on the lung function of 25 of 29 survivors of childhood leukaemia or lymphoma, who had been conditioned with cyclophosphamide and total body irradiation before allogeneic bone marrow transplantation, to test whether children are particularly vulnerable to pulmonary damage after transplantation. None developed chronic graft-versus-host disease. Transfer factor and lung volumes were reduced immediately after bone marrow transplantation, but increased during the following years. However, at the last follow up, 4-13 years (median 8) after transplantation, patients had significantly reduced transfer factor, total lung capacity, and forced vital capacity (-1.0, -1.2, and -0.8 SD score, respectively), and increased ratio of forced expiratory volume in one second to forced vital capacity (+0.9 SD score). None of the patients had pulmonary symptoms, and changes were unrelated to their age at bone marrow transplantation. In conclusion, patients had subclinical restrictive pulmonary disease at a median of eight years after total body irradiation and allogeneic bone marrow transplantation.
Data concerning safety of treatment in schoolchildren cannot be extrapolated to preschool children due to differences in growth velocity and metabolism. The safety issue in preschool children is further complicated by insufficient knowledge of the optimal dose, and the lung delivery from the devices available. Systemic activity has often been studied as a marker of adverse clinical effect. However, with improving technology, systemic activity can be detected within the range of the normal biological feedback system, where it is of no clinical importance. Therefore, systemic activity is not synonymous with clinically relevant side-effects. Side-effects should be assessed in specific clinical studies. Effect on growth velocity is a potential side-effect of major interest. Knemometry is a sensitive measure of short-term growth of the lower leg length in schoolchildren as well as in preschool children, which enables precise measurements of systemic activity, but it is not a measure of statural growth. The only clinically relevant outcome measure of human growth is the final height in relation to expected final height, allowing for gender and midparental height differences. In addition to effects on statural height, osteoperosis is an important potential side-effect. The importance of bone density during preschool age for final adult bone mineral density needs to be studied. Cataract formation is a side-effect associated with systemic steroid treatment and may be of special consideration during treatment with nebulized steroids, which may expose the eyes to high doses. Thrush, dysphonia and local skin atrophy in steroid-exposed areas are potential local side-effects, and yet the incidence in young children is unknown and dependent on the device used for delivery. When considering adverse effects of treatment, the risk of side-effects from undertreatment should always be observed.
A pear shaped non-electrostatic spacer, composed of steel with a volume of 250 ml and equipped with a facemask containing integrated inlet and outlet valves for inspiration and expiration, was compared with three plastic spacers. The plastic spacers were primed with repeated puffs from a budesonide pressurised metered dose inhaler (p-MDI) to minimise the electrostatic charge on the plastic. The procedure prolonged the half life (t1/2) of the aerosol in the Nebuhaler from nine to 32 seconds. A normal cleaning procedure reduced the aerosol t1/2 back to baseline. The t1/2 of the aerosol in the metal spacer was 27 seconds and independent of the use of p-MDI. In vitro the maximum dose of budesonide from a p-MDI, expressed as a percentage of the nominal dose, was 56% from the non-electrostatic spacer, 61% from the Nebuhaler, 45% from the Babyhaler, and 30% from the AeroChamber. In 124 children, age 6 months to 6 years, suspected to have asthma the non-electrostatic spacer delivered a mean total dose of budesonide aerosol of 39% of the nominal dose, which was significantly higher than the Babyhaler (28%), the Nebuhaler (21%), and the AeroChamber (19%). These differences were most pronounced in children younger than 4 years. The improved dose delivery from the small volume non-electrostatic spacer is probably related to the non-electrostatic spacer material and the valves which assured unidirectional airflow from the spacer without adding any dead space in the inspiratory channel. The non-electro-static spacer should improve the cost effectiveness of aerosol treatment and, as the counteracting effects of proming and recharging of the plastic from cleaning are avoided, should deliver a more reliable dose.
The aim of the study was to evaluate methods applicable in a clinical setting for monitoring of changes in lung function in awake young children. Impedance measurements by the impulse oscillation technique (ZIOS), respiratory resistance measurements by the interrupter technique (Rint) and transcutaneous measurements of oxygen tension (Ptc,O2) were compared with concomitant measurements of specific airway resistance (sRaw) and forced expiratory volume in one second (FEV1) by whole body plethysmography and spirometry, respectively, during methacholine challenge in 21 young children aged 4-6 yrs, with suspected asthma. Measurements with each technique were repeated after each challenge step. A special face-mask was developed with an integrated mouthpiece which ensured mouth breathing during the measurements. The order of sensitivity of the techniques to assess methacholine-induced changes in lung function was ZIOS > sRaw > Ptc,O2 > FEV1 > Rint. ZIOS was significantly more sensitive than all subsequent methods, and Ptc,O2 was significantly more sensitive than FEV1. ZIOS, sRaw and Rint, but not Ptc,O2 and FEV1, detected the subclinical increase in bronchial muscle tone in the children during baseline, which was revealed by the significantly reduced airway obstruction after inhalation of a beta 2-agonist as compared to baseline. It is concluded that ZIOS, Rint and Ptc,O2 change in parallel with sRaw and FEV1 and with a comparable sensitivity during simultanoeous measurements of the response to methacholine in young children aged 4-6 yrs. This implies that ZIOS, Rint and Ptc,O2 provide convenient indices of changes in lung function. Their combined use will be useful for monitoring airway diseases of young children.
The low tidal volume and flow in preschool children may reduce the efficiency of aerosol delivery from a pressurized metered-dose inhaler (pMDI) through a traditional holding chamber. A prototype small-volume steel holding chamber with two one-way valves was devised to prolong aerosol availability in the chamber and to ensure unidirectional airflow. Dead space between the valves was minimized to less than 2 ml. The dose-delivery and rate of passive disappearance of a budesonide pMDI aerosol were compared between this prototype and the large-volume, single-valved plastic Nebuhaler, in 164 asthmatic children less than 8 yrs of age. In vitro, the half life of aerosol disappearance in the steel prototype and the plastic Nebuhaler was > 30 s and 9 s, respectively. In vivo, the prototype delivered an age-independent mean dose of 38% of the nominal dose, and the Nebuhaler delivered an age-dependent mean dose, ranging from 42% of the nominal dose in children > or = 4 yrs to 19% of the nominal dose in infants. We conclude that the use of plastic for holding chambers may influence dose-delivery, and single-valve control may cause age-dependent dose-delivery. Reproducible age-independent drug-delivery may be achieved by pMDI aerosol inhaled through a small-volume metal holding chamber with separate inlet and outlet valves and minimized dead space. This holding chamber would improve the possibilities of aerosol therapy for young children.
There is a mandatory need for effortless drug administration to young children since the prevalence among them of recurrent wheezing is a 15-20%. It is becoming increasingly evident that many of these children respond dramatically well to beta2-agonists and topical steroids; accordingly this sub-group of children should be treated as asthmatics. The dose of topical steroids is critical as opposed to that of beta2-agonists which are often administered in doses well above the minimal effective dose. Budesonide suspension has proven its efficacy in adults in a study of 21 patients with asthma treated with budesonide suspension delivered from a nebulizer activated during inspiration versus metered dose inhalation (MDI) via a large-volume spacer. Nebulized in this manner the suspension exhibited a dose-dependent effect, apparently equipotent to the MDI administration as evaluated from daily peak expiratory flow measurements and symptom scoring. Continuous nebulization of budesonide in 18 schoolchildren with bronchial asthma similarly showed a dose-dependent improvement of lung function and symptom score, though in a 1:2 potency ratio as compared to MDI administration, probably due to loss of nebulized aerosol during expiration. In a subsequent study of 23 young children unresponsive to beta2-agonist therapy, nebulized budesonide was without demonstrable effect. Recently, a study of 31 young children with steroid-dependent asthma demonstrated a significant improvement from continuous nebulization of budesonide 1mg twice daily. In conclusion, the efficacy of nebulized budesonide has been convincingly demonstrated in patients with reversible symptoms of asthma.(ABSTRACT TRUNCATED AT 250 WORDS)
The question addressed in this study was the ability of young children to use a dry-powder inhaler, Turbuhaler. One hundred and sixty five children suspected of asthma, equally distributed in one year age-groups from 6 months to 8 yrs, inhaled from a Pulmicort Turbuhaler, 200 micrograms budesonide-dose-1, through a filter. The amount of drug trapped by the filter was used as a measure of drug released to the patient. None of the children had prior experience in the use of a Turbuhaler, but they were instructed carefully, together with their parents, in the clinic. The median dose released revealed an age-dependent increase, with a considerable scatter. Accordingly, the dose delivered could not be predicted in these young children. The limitation to effective use in young children appeared to be lack of sufficient co-operation, rather than physical limitations, as even some very young children appeared to obtain a sufficient activation of the device. It is likely that repeated training at home may improve these findings. In conclusion, our results indicate that dry-powder inhalers are not reliable in all circumstances for treatment of young children, and that careful and repeated tuition is required if such devices are to be used.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We challenged 30 pollen-sensitive volunteers with allergen, recorded symptoms and signs over a 10-h period, and rechallenged them after 24 h, in order to characterize the early and late allergic symptom response in the nose. The challenge was performed after topical pretreatment with the glucocorticosteroid budesonide (200 micrograms twice daily) for 14 d and with placebo in a double-blind, cross-over trial. The early response, consisting of sneezing, discharge, and blockage, was followed by a weak late response, consisting of a few sneezes and nose-blowings, and of a sustained nasal blockage. These symptoms did not have a well-defined peak in time, and a biphasic symptom curve could not be identified. The rechallenge response showed increased nasal responsiveness. The degree of budesonide effect on the early response varied, depending on the symptom; there was a marked effect on sneezing (72% reduction; P < 0.01), a moderate effect on discharge (37% reduction; P < 0.01), and a slight effect on blockage (17% reduction of nasal inspiratory peak flow rate; P < 0.02). The degree of inhibition of the rechallenge response was similar to the effect on the initial early response. The effect on the late response was very pronounced for all symptoms and signs (97% reduction of sneezes, 76% reduction of nose-blowings, 96% reduction of blockage; P < 0.01). In conclusion, we found it difficult in the individual subject to identify a well-defined late symptom response by criteria similar to those employed to characterize the late response in the bronchi. The effect of budesonide was more marked on sneezing than on blockage, and the drug was considerably more effective on the late response than on the early response.
The short-term linear growth rate of the lower leg in toddlers was measured and evaluated in order to study the possible effect of inhaled budesonide on this factor in toddlers with mild recurrent wheezing. The short-term linear growth rate of the lower leg was measured weekly using a hand-held knemometer. Eighteen toddlers aged 13-36 months (mean 27 months) with a history of recurrent wheezing requiring inhaled topical steroids, but without need of regular medication during the months prior to the study, were studied. The children were randomized blindly through three consecutive treatment periods of four weeks with placebo or budesonide in daily doses of 200 micrograms and 800 micrograms administered as a pressurized aerosol inhaled via a spacer with a face mask. Twenty-nine percent (median) of the nominal dose was delivered at the mouth of the children. Three children were withdrawn because of exacerbations and one because of non-compliance. The precision of the measurement procedure was 51 microns/day. The mean growth rate during placebo, low-dose and high-dose steroid treatment was 92 microns/day, 114 microns/day and 46 microns/day respectively. The growth rate during the high-dose treatment was suppressed significantly compared to placebo treatment (95% CI -76 microns/day to -17 microns/day), whereas the growth rate during low-dose steroid treatment was indistinguishable from placebo treatment (95% CI -7 to +52 microns/day). In conclusion, measurement of short-term linear growth rate by knemometry in toddlers is a fast and gentle method with a high level of precision.(ABSTRACT TRUNCATED AT 250 WORDS)
Leukotrienes (LTs) are potent mediators of inflammatory and allergic responses, and are present in biological fluids in minute amounts, that is, in the picogram range. The aim of this study was to develop and validate a method for determination of LTB4 synthesized in vitro in human whole blood. Heparinized blood was stimulated with calcium-ionophore A23187 at 37 degrees C. After 30 min cells were separated by centrifugation. LTB4 was analyzed by radioimmunoassay (RIA). When sample preparation was restricted to protein precipitation with acetone, interference was demonstrated by lack of parallelism between standard and sample dilution curves. Purification was, therefore, extended by combinations of the following steps: 1) protein precipitation, 2) lipid extractions, and 3) high-performance liquid chromatography (HPLC). One of two commercially available LTB4 standards was found to contain multiple components, several of which were immunoreactive in RIA. Even for the standard containing pure LTB4, interference was demonstrated by lack of parallelism between sample and standard dilution curves. Testing eight combinations of varying purification steps, we found that only a three-step purification procedure, including 1) solid-phase extraction, 2) protein precipitation at -20 degrees C, and 3) HPLC, was able to eliminate interference in RIA. Using this procedure, the recovery was 78%. Stimulation of whole blood from normal subjects with calcium-ionophore showed optimal LTB4 production at 10 microM ionophore, yielding 6.6 ng LTB4/mL blood.