Search PubMed⌕ Search

Biomedical subjects

H Bisgaard

Publications and source records attributed to H Bisgaard.

At least 37 records · Page 2Linked to original sources

Role of leukotrienes in asthma pathophysiology.

Inflammation is an essential component of asthma pathophysiology. While beta(2)-agonists are often used for short-term relief of acute bronchospasm, anti-inflammatory agents are required for the long-term management of chronic inflammation in this disease. Corticosteroids have emerged as the first-line anti-inflammatory therapy for asthma management. However, in some patients, especially children, the high doses of corticosteroids that may be required to control features of hyperresponsiveness, including exercise-induced asthma, raise safety concerns. Thus, there is a need for complementary anti-inflammatory, steroid-sparing agents in asthma therapy. Several inflammatory mediators have been targeted in an attempt to thwart this inflammatory process, but so far with little success. The cysteinyl leukotrienes (CysLT), LTC(4), LTD(4), and LTE(4), have been shown to be essential mediators in asthma, making them obvious targets for therapy. These cysteinyl leukotrienes, previously known as the slow-reacting substance of anaphylaxis (SRS-A), mediate many of the features of asthma, including bronchial constriction, bronchial hyperreactivity, edema, and eosinophilia. Data show that selective cysteinyl leukotriene receptor antagonists (CysLTRAs) effectively reverse these pathologic changes. Corticosteroids do not inhibit the production of CysLTs in vivo, suggesting that CysLTRAs and corticosteroids affect different targets. The bronchodilator properties of CysLTRAs seem to be additive to those of beta(2)-agonists and corticosteroids. These data suggest that CysLTs are important therapeutic targets in the management of inflammation in asthma.

Adrenal Cortex Hormones↗

Observer variability of lung function measurements in 2-6-yr-old children.

The aim of this study was to assess the within-observer and between-observer variability of lung function measurements in children aged 2-6 yrs. Two observers examined 22 asthmatic children independently according to a predefined protocol. Each observer obtained duplicate measurements of respiratory resistance by the interrupter technique (Rint), respiratory resistance (Rrs,5) and reactance (Xrs,5) at 5 Hz by the impulse oscillation technique and the specific airway resistance (sRaw) by whole body plethysmography. The within-subject SD (SDw) was not significantly different in the two observers. The ratio SDw between observers/mean SDw within observers was 0.94, 1.25, 1.35 and 2.86 for Xrs,5, Rrs,5, sRaw and Rint, respectively, indicating greater between-observer variability of the latter. The systematic difference between observers assessed by the difference between observer means (expressed as a percentage of their mean value) was 11, 7, 6 and 2% for Xrs,5, sRaw, Rrs,5 and Rint, respectively. These differences were statistically significant, except that for Rint. In conclusion, specific airway resistance, impulse oscillation technique and respiratory resistance assessed by the interrupter technique measurements in young children are subject to influence by the observer, and the random variability between observers appears to be particularly great for respiratory resistance assessed by the interrupter technique. The authors suggest that the between-observer variability should be investigated when evaluating novel methods for testing lung function.

Airway Resistance↗

Montelukast or salmeterol combined with an inhaled steroid in adult asthma: design and rationale of a randomized, double-blind comparative study (the IMPACT Investigation of Montelukast as a Partner Agent for Complementary Therapy-trial).

Asthma patients who continue to experience symptoms despite taking regular inhaled corticosteroids represent a management challenge. Leukotrienes play a key role in asthma pathophysiology, and since pro-inflammatory leukotrienes are poorly suppressed by corticosteroids it seems rational to add a leukotriene receptor antagonist (LTRA) when a low to moderate dose of inhaled corticosteroids does not provide sufficient disease control. Long acting beta2-agonist (LABA) treatment represents an alternative to LTRAs and both treatment modalities have been shown to provide additional disease control when added to corticosteroid treatment. To compare the relative clinical benefits of adding either a LTRA or a LABA to asthma patients inadequately controlled by inhaled corticosteroids, a randomized, double-blind, multi-centre, 48-week study will be initiated at approximately 120 centres throughout Europe, Latin America, Middle East, Africa and the Asia-Pacific region in early 2000. The study will compare the oral LTRA montelukast with the inhaled LABA salmeterol, each administered on a background of inhaled fluticasone, on asthma attacks, quality of life, lung function, eosinophil levels, healthcare utilization, and safety, in approximately 1200 adult asthmatic patients. The requirements for study enrollment include a history of asthma, FEV1 or PEFR values between 50% and 90% of the predicted value together with > or = 12% improvement in FEV1 after beta-agonist administration, a minimum pre-determined level of asthma symptoms and daily beta-agonist medication. The study will include a 4-week run-in period, during which patients previously taking inhaled corticosteroids are switched to open-label fluticasone (200 microg daily), followed by a 48-week double-blind, treatment period in which patients continuing to experience abnormal pulmonary function and daytime symptoms are randomized to receive montelukast (10 mg once daily) and salmeterol placebo, or inhaled salmeterol (100 microg daily) and montelukast placebo. All patients will continue with inhaled fluticasone (200 microg daily). During the study, asthma attacks, overnight asthma symptoms, and morning peak expiratory flow rate will be assessed using patient diary cards; quality of life will also be assessed using an asthma-specific quality-of life questionnaire. The results of this study are expected to provide physicians with important clinical evidence to help them make a rational and logical treatment choice for asthmatic patients experiencing breakthrough symptoms on inhaled corticosteroids.

Acetates↗

Lung function response to cold air challenge in asthmatic and healthy children of 2-5 years of age.

The aim of the study was to assess feasibility, sensitivity, specificity, predictive value, and repeatability of cold, dry air challenge (CACh) as a diagnostic test for asthma in young children 2 to 5 yr of age. Response to a 4-min single-step isocapnic CACh was measured in 38 asthmatics and 29 control subjects. Specific airway resistance (sRaw) by whole body plethysmography was the primary outcome. In addition, lung function was measured as respiratory resistance by the interrupter technique (Rint) and respiratory resistance and reactance at 5 Hz (Rrs5, Xrs5) by the impulse oscillation technique. At baseline, lung function measures differed significantly between asthmatics and healthy control subjects. CACh was readily performed in young children. Response was expressed as change from baseline in numbers of within-subject standard deviation (SDw). Hyperresponsiveness defined as change in lung function of more than 3 SDw was detected by sRaw in 26 of 38 asthmatics versus 2 of 29 control subjects, by Rint in 12 of 38 asthmatics versus 1 of 29 control subjects, by Xrs5 in 9 of 38 asthmatics versus zero of 29 control subjects and by Rrs5 in 7 of 38 asthmatics versus 1 of 29 control subjects. Thus sRaw had the highest sensitivity (68%). Specificity ranged from 93 to 100%. The correlation coefficient between sRaw responses to CACh repeated within 8 wk was 96%. In conclusion, CACh is feasible in young children age 2 to 5 yr. Whole body plethysmography (sRaw) was superior in separating asthmatics from healthy control subjects. Change in sRaw in response to CACh may be used as a diagnostic test for asthma in young children.

Asthma↗

Bronchoprotection with a leukotriene receptor antagonist in asthmatic preschool children.

We hypothesized that a leukotriene receptor antagonist (LTRA) could provide bronchoprotection against the cold, dry air-induced response in asthmatic preschool children. In a randomized, double-blind, placebo-controlled crossover study, we examined the effect of the specific LTRA montelukast at 5 mg/d for 2 d on the bronchoconstriction induced by hyperventilation of cold, dry air in 13 asthmatic children 3 to 5 yr old. The bronchoconstriction was measured as the specific airway resistance (sRaw) in a whole-body plethysmograph before and 4 min after challenge with cold, dry air. The repeatability of the bronchoprotection was examined by repeating the placebo-controlled study in six of the 13 children. sRaw increased by an average of 46% (95% confidence interval [CI]: 30 to 63%) after placebo treatment and 17% (95% CI: 3 to 31%) after montelukast (p < 0.01). Eight of the children were receiving regular treatment with budesonide delivered by an inhaler with a spacer in a mean daily dose of 350 microg, but the bronchoprotection provided by montelukast was independent of concurrent steroid treatment. There was no convincing evidence of failure to respond, and the protective effect of montelukast was consistent upon repeated testing (p = 0. 02). We conclude that the LTRA montelukast provided clinically significant bronchoprotection against the effect of hyperventilation of cold dry air in asthmatic children 3 to 5 yr old. The bronchoprotection appeared to be homogeneous among the children, and seemed independent of steroid treatment. This suggests that LTRAs may be of therapeutic use in limiting clinical symptoms of asthma in young children.

Acetates↗

The effect of inhaled budesonide on symptoms, lung function, and cold air and methacholine responsiveness in 2- to 5-year-old asthmatic children.

We hypothesized that measurement of lung function (LF) and bronchial hyperresponsiveness (BHR) could serve as supplemental tools in evaluating the efficacy of treatment with inhaled corticosteroids in asthmatic children aged 2 to 5 yr. We studied 38 children (mean age: 53 mo; range: 35 to 71 mo) with moderately severe asthma in a single-center, randomized, double-blind, parallel-group, placebo-controlled study involving 8 wk of treatment. Budesonide (BUD) 400 microgram twice daily was administered via a pressurized metered-dose inhaler and metal spacer device. Symptom scores (SSc) and use of short-acting beta(2)-agonist were monitored with diary cards. LF in awake children was measured as the specific airway resistance (sRaw), using whole-body plethysmography; as resistance by the interrupter technique (Rint); and as resistance and reactance at 5 Hz (Rrs5, Xrs5) by the impulse oscillation technique. Cold air challenge (CACh) and methacholine challenge (MCh) were used to assess BHR. Children in the BUD group experienced significantly fewer night- and daytime symptoms (p < 0.05) and more symptom-free days (p < 0.05), but not nights (p = 0.07), than children in the placebo group. Daytime (p < 0.05) but not nighttime (p = 0.09) use of rescue medication and asthma exacerbation rates (3.7 versus 9.3 exacerbations/yr) (p = 0.006) were both in favor of BUD. LF measured with the Rint technique, Rrs5, and Xrs5 were significantly improved by BUD. BHR as measured by CACh improved significantly with BUD, whereas no improvement was found on MCh. In conclusion, inhaled BUD at a total dose of 800 microgram daily significantly improved SSc, asthma exacerbation rates, lung function, and BHR as assessed by CACh in asthmatic children aged 2 to 5 yr.

Administration, Inhalation↗

Lung deposition of inhaled drugs increases with age.

Budesonide plasma concentrations after inhalation of a fixed dose of the drug from a pressurized metered dose inhaler (pMDI) with spacer (Nebuchamber) were compared in young children and adults: 26 patients with mild asthma comprising 8 children 2-3 yr, 8 children 4-6 yr, and 10 adults 20-41 yr. Budesonide 2 x 200 microg was given by pMDI via Nebuchamber with mouthpiece and noseclip. Children of 2-3 yr used a facemask. Plasma was collected regularly for 8 h after drug administration. Budesonide was measured by liquid chromatography plus tandem mass spectrometry. The dose to patient was estimated as the dose of budesonide delivered from the pMDI with adapter minus the amount of budesonide recovered from the spacer, facemask, or mouthpiece, mouth rinse, and facial skin. The systemic exposure was estimated from the plasma concentration and expressed as the area under the curve of plasma concentration versus time (AUC). Terminal half-life (T(1/2)) was evaluated. Dose to patient, AUC, and T(1/2) were similar in the three age groups (p > 0.35). Nebuchamber delivers the same dose of budesonide to young children and adults. Yet the plasma concentration of budesonide was similar in young children and adults. Therefore, lung dose is increased with age. This suggests that from a safety perspective, the prescribed dose of budesonide inhaled from a pMDI with Nebuchamber spacer need not be adjusted for age or use of facemask. Children and adults can use the same nominal dose of budesonide via Nebuchamber as adults without an increased risk of systemic exposure.

Administration, Inhalation↗

Impact of constant and breath-synchronized nebulization on inhaled mass of nebulized budesonide in infants and children.

The aim of the present study was to compare the output of a breath-synchronized jet nebulizer to a conventional constant output nebulizer over a fixed period of time in terms of inhaled mass of budesonide, i.e., the amount of budesonide deposited on a filter interposed between the nebulizer and the face mask. One hundred and sixty-five asthmatic children (103 boys) were enrolled in this open, randomized, crossover trial. Their age ranged from 6 months to 7.9 years, height from 69 to 132 cm, and weight from 8.2 to 31.3 kg. Their duration of asthma ranged from less than 1 to 7 years. Budesonide suspension, 0.5 mg mL-1, 2 mL, was used. With 5 min of constant output nebulization, the mean inhaled mass of budesonide in percent of the nominal dose was 11.4% in the youngest children and 14.9% in the 7-year-old children. Expressed in percent of the total output of budesonide, i.e., the amount that left the nebulizer as an aerosol, the inhaled mass ranged from 34.6-48.6%. Thus, 51.4-65.4% of the total output was deposited on the expiratory filter. With 5 min of breath-synchronized nebulization, the mean inhaled mass ranged from 10.5-14.9% of the nominal dose. For the youngest patients less than 3-4 years of age, it was approximately 80-90% of the total output. For the older patients the inhaled mass was approximately 95% of the total output, i.e., only small amounts of budesonide were deposited on the expiratory filter. For both modes of nebulization the between-subject variation in inhaled mass was large: up to 6-fold in the young children and 3-4-fold in the older ones. The results of the present study showed that the inhaled mass of budesonide was significantly age-dependent with both modes of nebulization, i.e., the inhaled mass was less in younger children. Breath-synchronized nebulization resulted in reduced waste of drug during expiration.

Administration, Inhalation↗

Effect of electrostatic charge in plastic spacers on the lung delivery of HFA-salbutamol in children.

AIMS: The effect of the electrostatic charge in plastic spacers in vivo on drug delivery to the lung of hydrofluoroalkane (HFA) salbutamol spray was studied in children. METHODS: Five children, aged 7-12 years, were included in a 3-way crossover randomised single-blind trial. Salbutamol HFA spray was delivered on 3 different study days from plastic spacers with mouthpiece. Pre-treatment of the spacers differed between study days: (a) Non-electrostatic 350 ml Babyhaler (coated with benzalkonium chloride) (b) New 350 ml Babyhaler (rinsed in water), and (c) New 145 ml AeroChamber (rinsed in water). Plasma salbutamol was measured before and 5, 10, 15 and 20 min after inhalation of four single puffs of 100 microg salbutamol. Cmax and Cav (5-20min) were calculated as a reflection of lung dose. RESULTS: For Cmax: (A) Non-electrostatic Babyhaler 4.3 ng ml(-1) (B) New Babyhaler 1.9 ng ml(-1) (C) New AeroChamber 1.6 ng ml(-1): AvsB (95% CI for difference 0.5-4.5 ng ml(-1)), A vs C (95% CI for difference 0.7-4.8 ng ml(-1)). The geometric mean ratio for A:B was 2.4 fold, and for A:C was 2.9 fold. The values for Cav were similar with ratios for A:B of 2.4 fold, and A: C of 4.1 fold. The nonelectrostatic Babyhaler delivered a significantly (P<0.05) higher lung dose (for both Cmax and Cav) than either of the other two spacers. CONCLUSIONS: The electrostatic charge in plastic spacers reduces lung dose in children by more than two-fold. This is clinically significant and the use of potentially electrostatically charged spacers should be avoided.

Absorption↗

A mathematical model of aerosol holding chambers.

A mathematical model of aerosol delivery from holding chambers (spacers) was developed incorporating tidal volume (VT), chamber volume (Vch), apparatus dead space (VD), effect of valve insufficiency and other leaks, loss of aerosol by immediate impact on the chamber wall, and fallout of aerosol in the chamber with time. Four different spacers were connected via filters to a mechanical lung model, and aerosol delivery during "breathing" was determined from drug recovery from the filters. The formula correctly predicted the delivery of budesonide aerosol from the AeroChamber (Trudell Medical, London, Ontario, Canada), NebuChamber (Astra, Södirtälje, Sweden) and Nebuhaler (Astra) adapted for babies. The dose of fluticasone proportionate delivered by the Babyhaler (Glaxco Wellcome, Oxbridge, Middlesex, UK) was 80% of that predicted, probably because of incomplete priming of this spacer. Of the above-mentioned factors, initial loss of aerosol by impact on the chamber wall is most important for the efficiency of a spacer. With a VT of 195 mL, the AeroChamber and Babyhaler were emptied in two breaths, the NebuChamber in four breaths, and the Nebuhaler in six breaths. Insufficiencies of the expiratory valves were demonstrated by comparison of pressure flow curves during "inspiratory" flow with and without occluded expiratory openings. Insufficient inspiratory valves were demonstrated by comparison of "expiratory" pressure flow curves with and without occluded inspiratory openings. With children breathing through the spacers, mask pressure variations were generally on the same order as that seen with the mechanical respiratory, supporting the clinical relevance of the in vitro findings.

Aerosols↗

Future options for aerosol delivery to children.

There is an increasing awareness of the importance of reliable aerosol delivery, with emphasis on the dose delivered to the lungs, optimal clinical control, cost-effectiveness, and safety in children. Dose prescription should relate to the expected lung dose rather than the factory-dispensed dose, as at present. The device determines the lung dose. Clearly, therefore, the device should be considered an integral part of the prescription. Drug approval processes should clearly specify the device, and discourage the use of other devices. This would rationalize the choice of devices. Important new insights into factors essential for drug delivery to the airways have been acquired in recent years. Nasal inhalation increases systemic bioavailability, reduces lung dose, and adds to its variability; hence, face masks to prevent nasal breathing have been developed. Similarly, dead space in the inspiratory line causes a proportional reduction in lung dose; hence, attention should be paid to reducing such dead space. Plastics in spacers cause a rapid loss of drug due to electrostatic attraction of the aerosol. The residence time of the aerosol, i.e., the time available for inhalation, is increased in nonelectrostatic spacers, allowing less compliant children enough time to obtain a full dose. Eliminating the electrostatic charge can change the lung dose by several times; hence, nonelectrostatic materials should be used in future spacer devices. Compliance is the biggest problem in drug delivery to children. The inhaler design process should be reversed, adapting technology to the child. Interactive microchip technology should provide intelligent devices that react to correct handling and breathing maneuvers. An intelligent nebulizer has been developed that adapts nebulization to the child's breathing pattern, nebulizing only during inhalation and avoiding loss of aerosol during exhalation. An automatic device (AirPac) has been developed that transforms a dry-powder inhaler, Turbuhaler, into a spacer. In addition to the general advantages of spacer treatment, this device offers the advantage of a drug aerosol delivered without use of propellants or additives. The mechanical actuation ensures highly repeatable drug delivery. Finally, a nonelectrostatic, tower-shaped spacer provides a stable aerosol, which remains airborne for a prolonged period. The spacer is equipped with a face mask that prevents nasal breathing. Such features should improve our ability to treat young children with inhaled drug aerosols.

Aerosols↗

The effect of inhaled fluticasone propionate in the treatment of young asthmatic children: a dose comparison study.

The response in asthmatic young children to inhaled steroids within the usual pediatric dose range is unknown. We therefore evaluated the dose-related response in young children with moderate asthma to inhaled fluticasone propionate (FP) (delivered via the Babyhaler spacer device) within the pediatric dose range. A total of 237 children (mean age 28 mo, range 12 to 47) with moderate asthmatic symptoms were studied in this multicenter, randomized, double-blind, parallel group, placebo-controlled study of 12 wk treatment following a 4-wk run-in period. The median use of rescue medication was 1 dose in 2 d during the run-in period. FP 50 micrograms twice daily (FP100) and 100 micrograms twice daily (FP200) was compared with placebo inhaled from a pressurized metered-dose inhaler (pMDI) and the Babyhaler spacer device. With FP200 there was a statistically significant improvement from baseline, as compared with the placebo group, in 8 of 10 diary card parameters, including the three symptom domains of wheeze, cough, and breathlessness, and use of rescue medication. FP100 produced a significant reduction in 5 of these 10 parameters, whereas no significant differences were found between the FP200 and FP100. The numbers of patients with at least one exacerbation during treatment with placebo, FP100, and FP200 were 37%, 26%, and 20%, respectively. This difference between placebo and FP200, as well as the dose-related order was significant (p < 0.05). Both FP doses were as well tolerated as placebo over the 12 wk treatment with a similar incidence of adverse effects. Asthmatic symptoms in 1- to 3-yr-old children responded in a significant and dose-related manner to treatment with FP within a pediatric dose range.

Administration, Inhalation↗

NO in exhaled air of asthmatic children is reduced by the leukotriene receptor antagonist montelukast.

Nitric oxide in exhaled air (FENO) is increased in asthmatic children, probably reflecting aspects of airway inflammation. We have studied the effect of the leukotriene receptor antagonist (LTRA) montelukast on FENO with a view to elucidate potential anti-inflammatory properties of LTRAs. Twenty-six asthmatic children 6 to 15 yr of age completed a double-blind crossover trial of 2 wk of treatment with 5 mg montelukast once daily versus placebo. FENO was measured during single-breath exhalation at a constant flow rate of 0.1 to 0.13 L/s against a resistance of 10 kPa/L/s. Eleven children were receiving maintenance treatment with inhaled steroids during the study (mean daily dose, 273 microgram), whereas the other 15 used only inhaled beta(2)-agonists as required. The within-subject coefficient of variation of FENO over a 2-wk interval for the 26 children was 38%. FENO was significantly reduced by 20% after the 2-wk treatment with montelukast as compared with placebo as well as compared with baseline. This effect occurred rapidly with a 15% fall in FENO within 2 d. The effect of montelukast on FENO was independent of concurrent steroid treatment. The effect on FENO is probably not caused by bronchodilatation since FENO increased significantly after inhalation of terbutaline. In conclusion, FENO in asthmatic children was significantly decreased from montelukast, which corroborates anti- inflammatory properties of LTRA.

Acetates↗

Lung function and short-term outcome in young asthmatic children.

The aims of this study were to investigate lung function in 2-5-yr-old stable asthmatic children consecutively referred from general practitioners and to analyse the outcome on the basis of their requirement for antiasthmatic treatment and symptoms after 1.6-4.5 yrs. Lung function was measured in 110 children with a mean+/-SD age of 3.8+/-1.0 yrs using the interruptor technique (resistance assessed using the interruptor technique (Rint)), whole body plethysmography (specific airway resistance (sRaw) and respiratory resistance (Rrs,5)and reactance at 5 Hz (Xrs,5) using the impulse oscillation technique. Rint, sRaw, Xrs,5 and Rrs,5 were suggestive of impaired lung function in 44%, 14%, 11% and 7.5% of the children, respectively, with a predominance of children aged 2-3 yrs. Sixty-five per cent were treated with inhaled steroids, and 35% were treated only with beta2-agonists as needed; lung function was not significantly different between these two groups. Outcome after 2.9+/-0.7 yrs was not significantly different between children with Rint measurements above and those children with Rint measurements within the reference range at enrolment. Of these children, 58 and 59% were currently on antiasthmatic treatment, and 40% and 49% had current symptoms, respectively. Impairment of lung function may be a common finding in stable young asthmatic children, but apparently this is not a risk factor for persistence of asthmatic symptoms.

Anti-Asthmatic Agents↗