Search PubMed⌕ Search

Biomedical subjects

H Becher

Publications and source records attributed to H Becher.

At least 55 records · Page 3Linked to original sources

[Brain infarct from a paradoxical embolism following a varices operation].

HISTORY AND CLINICAL FINDINGS: A 70-year-old woman developed an acute right-sided hemiparesis and global aphasia 10 days after saphenous vein stripping of varicosities. Initially, she presented with somnolence, conjugated to the left, flexor synergism of the right extremities, exaggeration of knee and ankle jerks and extensor plantar responses on the right side. INVESTIGATIONS: The initial cranial computed tomography one hour after the onset of symptoms did not show reliable signs of cerebral ischaemia but a "dense artery sign" of the left middle cerebral artery. Repeat computed tomography then revealed a partial, mainly subcortical, infarction of the left middle cerebral artery territory. Doppler sonography revealed an occlusion of the left internal carotid artery. In duplex sonography there was no evidence of arteriosclerosis. Transesophageal echocardiography revealed a patent foramen ovale with right-to-left shunt. TREATMENT AND COURSE: Immediately after admission intravenous anticoagulation was initiated because of the suspected cardioembolic origin of the stroke. During hospitalization the global aphasia regressed and a continuing mobilization was achieved while the right-sided hemiparesis persisted. The neurological rehabilitation was initiated and continuous oral anticoagulation was planned. CONCLUSION: This case suggests a causal relationship between previously performed vein stripping and paradoxical embolism resulting in a stroke. For patients with patent foramen ovale, vein stripping may be associated with an increased stroke risk.

Aged↗

Progesterone receptor gene polymorphism is associated with decreased risk for breast cancer by age 50.

In a population-based case-control study for breast cancer before the age of 51 years, 554 cases and 559 age-matched controls were genotyped for the polymorphic progesterone receptor allele PROGINS. Breast cancer risk was decreased in women carrying the PROGINS allele. The odds ratio adjusted for age and study region was 0.76 [95% confidence interval (CI), 0.58-1.00]. Compared with wild-type A1/A1 homozygotes, the odds ratio for A1/A2 heterozygotes and A2/A2 homozygotes was 0.82 (95% CI, 0.62-1.08) and 0.27 (95% CI, 0.10-0.74), respectively, suggesting a gene dosage effect of the A2 allele. There was suggestive evidence for a differential effect by menopausal status (P = 0.07) and by family history of breast cancer (P = 0.15).

Adult↗

[Myocardial contrast echocardiography. Research instrument or already clinical application?].

Increasing interest has been focused on myocardial contrast echocardiography (MCE) since latest imaging technologies allow the detection of echocontrast agents within myocardial structures following intravenous injections. Although numerous studies on different aspects of pre-clinical and clinical applications have been published, MCE has not yet become a standard clinical application. This paper summarises and estimates the clinical value of the recent developments in this evolving field of research, particularly with regard to the new real-time perfusion imaging technologies.

Animals↗

Stimulated acoustic emission: pseudo-Doppler shifts seen during the destruction of nonmoving microbubbles.

The purpose of this study was to evaluate the appearance and the characteristics of stimulated acoustic emission (SAE) as an echo contrast-specific color Doppler phenomenon with impact on myocardial contrast echocardiography (MCE). Stationary microbubbles of the new contrast agent SH-U 563A (Schering AG) were embedded within a tissue-mimicking gel material. Harmonic power Doppler imaging (H-PDI), color Doppler and pulse-wave Doppler data were acquired using an HDI-5000 equipped with a phased-array transducer (1.67/3.3 MHz). In color Doppler mode, bubble destruction resulted in random noise like Doppler signals. PW-Doppler revealed short "pseudo-Doppler" shifts with a broadband frequency spectrum. Quantification of SAE events by H-PDI demonstrated an exponential decay of signal intensities over successive frames. A strong linear relationship was found between bubble concentration and the square root of the linearized H-PDI signal for a range of concentrations of more than two orders of magnitude (R = 0.993, p < 0.0001). Intensity of the H-PDI signals correlated well with emission power (R = 0.96, p = 0.0014). SAE results from disintegration of microbubbles and can be demonstrated by all Doppler imaging modalities, including H-PDI. Intensity of SAE signals is influenced by the applied acoustic power and correlates highly with the concentration of microbubbles. Because intensity of SAE signals correlates highly with echo contrast concentrations, analysis of SAE signals might be used for quantitative MCE.

Acoustics↗

Combining a name algorithm with a capture-recapture method to retrieve cases of Turkish descent from a German population-based cancer registry.

An increasing proportion of the 2 million Turkish residents in Germany is reaching the age in which cancer becomes a common health problem. However, data on cancer incidence and survival among Turkish residents are lacking due to incomplete reporting of nationality in German cancer registries. In the population-based cancer registry of the Saarland, retrieval by reported nationality yielded only 38% (95% confidence interval (CI): 31-45%) of the estimated number of Turkish cases in the registry; furthermore, nationality information was found to be inaccurate, and completeness dependent on the vital status of cases. A newly developed algorithm based on family names retrieved 85% (95% CI: 79-90%) of Turkish cases. Combining the two sources in a capture-recapture approach yielded 91% (95% CI: 86-94%) of the estimated total number of Turkish cases. Hence, the name-based algorithm provides a new and attractive tool for valid registry-based cancer research among Turks in Germany.

Algorithms↗

Breastfeeding and breast cancer risk by age 50 among women in Germany.

BACKGROUND: Epidemiological evidence which suggests that prolonged breastfeeding protects against breast cancer has accumulated in recent years. Issues with regard to the timing of breastfeeding and effect modification by correlates of breastfeeding and other risk factors of breast cancer remain unresolved. METHODS: A population-based case control family study of breast cancer among women diagnosed by the age of 50, conducted in two geographic areas in Germany, was used to evaluate the effect of breastfeeding on risk of breast cancer. RESULTS: Among parous women in this study (553 cases, 1094 age-matched population controls), having ever breastfed a child for at least 1 month did not confer protection (odds ratio of 0.9 and 95% confidence interval (CI) 0.8-1.2). However, risk of breast cancer significantly decreased with increasing duration of breastfeeding (p for trend = 0.01) and the estimated relative risk was 0.6 (95% CI 0.4-0.9) for 13-24 months of cumulative breastfeeding and 0.5 (95% CI 0.3-1.1) for 25 months or more. Risk was less related to number of children breastfed than to increasing average length of breastfeeding per child (p for trend = 0.03). CONCLUSIONS: The reduction in risk associated with duration of breastfeeding was not primarily due to breastfeeding the firstborn and more evident in women who were older (> 25 years) when they first breastfed and among women who experienced a recent full-term pregnancy. Risks were modified somewhat by a first-degree family history of breast cancer whereby a greater reduction in risk per additional month of breastfeeding was observed among women with a family history than those without (0.9 vs. 1.0). The study results support a protective role of prolonged breastfeeding against the development of breast cancer in predominantly premenopausal women in Germany.

Adult↗

Incidence of left atrial thrombi in patients in sinus rhythm and with a recent neurologic deficit.

OBJECTIVES: We sought to determine the incidence of left atrial (LA) thrombi in patients in sinus rhythm (SR) and with a recent neurologic deficit and to analyze the relation between LA thrombi and LA chamber and appendage function in patients in SR. METHODS: A prospective study was conducted in 869 consecutive patients. The study group consisted of 583 patients in SR (67%). The remaining 286 patients had atrial fibrillation (AF) and served as controls (33%). RESULTS: The incidence of LA thrombi was significantly higher in patients with AF (n = 39 [14%]) compared with patients in SR (n = 6 [1%]; P <.001). Three of 6 patients with thrombi in SR had mitral stenosis, 1 patient had aortic stenosis, 1 patient had coronary artery disease, and another patient had a cardiomyopathy. Of the patients with detected thrombi, those in SR did not receive anticoagulation, whereas those with AF did in 18 cases. Patients with thrombi in SR and with AF did not significantly differ in LA diameter (5.1 +/- 0.8 cm vs 4.8 +/- 0.7 cm; 95% confidence interval [CI], -0.78 to 0.45), left ventricular ejection fraction (46% +/- 13% vs 42% +/- 15%; 95% CI, -18.7 to 7.4), LA appendage area (5.8 +/- 2.7 cm(2) vs 6.7 +/- 3.2 cm(2); 95% CI, -1.9 to 3.6), peak emptying velocity of the LA appendage (0.19 +/- 0.08 m/s vs 0.17 +/- 0.07 m/s; 95% CI, -0.08 to 0.04), or LA spontaneous echo contrast (3. 5 +/- 0.6 vs 3.9 +/- 0.5; 95% CI, -0.06 to 0.45). CONCLUSIONS: LA appendage thrombi are an infrequent cause of thromboembolism in patients in SR and are associated either with mitral valve disease or LA chamber and appendage dysfunction. Routine transesophageal echocardiography for the exclusion of LA thrombi is not recommended in patients in SR without underlying heart disease and normal LA function as assessed by transthoracic echocardiography.

Aortic Valve Stenosis↗

Are microbubbles free flowing tracers through the Myocardium? Comparison of indicator-dilution curves obtained from dye dilution and echo contrast using harmonic power Doppler imaging.

BACKGROUND: Harmonic power Doppler imaging (H-PDI) has been introduced into the field of contrast echocardiography as a contrast-specific imaging modality. However, there has been considerable skepticism as to whether H-PDI would be quantifiable, because it depends on the destruction of microbubbles and has more complex signal processing than gray scale imaging. The aim of the present study was to evaluate the relationship between the concentration of microbubbles and the resulting H-PDI signals even under conditions where bubble destruction is most likely. Furthermore, we evaluated whether microbubbles of Levovist freely pass the microcirculation, which is a prerequisite for the assessment of myocardial blood flow. METHODS AND RESULTS: A strong positive correlation was found between the H-PDI signals and the amount of microbubbles up to the onset of acoustic shadowing (r = 0. 968, P<0.001). Time-intensity curves for H-PDI of air-filled microbubbles were compared with time-concentration curves of indocyanine green (ICG) in both a flow phantom and a working heart setup. The mean transit times (MTTs) through the myocardium of both agents were compared after a bolus injection into the left coronary artery. A close correlation was observed between 1/MTT and flow in both setups (r>0.98, P<0.0001). However, at high flow rates, the MTTs of the microbubbles were slightly, albeit not significantly, faster than those of indocyanine green. CONCLUSIONS: We conclude that microbubbles fulfill the prerequisites of free flowing tracers through the myocardium. Furthermore, H-PDI technology allows a reliable assessment of time-concentration curves of air-filled microbubbles up to the onset of acoustic shadowing.

Animals↗

Assessment of myocardial perfusion by power contrast imaging using a new echo contrast agent.

In a patient with previously documented myocardial infarction, we assessed myocardial perfusion by using power contrast imaging and a newer intravenous echo contrast agent. The images were captured and stored digitally, and various image processing algorithms were used to assess myocardial perfusion. An apical perfusion defect was clearly visualized, and it correlated with radionuclide findings.

Contrast Media↗

Stimulated acoustic emission detected by transcranial color doppler ultrasound : a contrast-specific phenomenon useful for the detection of cerebral tissue perfusion.

BACKGROUND AND PURPOSE: Experimental and clinical data suggest that insonation of echo-contrast agents with high acoustical power produces disintegration of microbubbles, resulting in a pseudo-Doppler phenomenon called stimulated acoustic emission (SAE). The purpose of this study was to investigate whether SAE might be detected by transcranial color Doppler imaging and whether these signals might be used for cerebral tissue perfusion measurements. METHODS: Nonmoving microbubbles (SHU 563 A) were insonated in vitro through the temporal parts of a human cadaver skull, and contrast signals were detected by velocity-coded color Doppler and power Doppler recordings. Transcranial color as well as power Doppler investigations were performed in 10 healthy volunteers with the echo-contrast agent Levovist (SHU 508 A). RESULTS: Color Doppler signals indicating SAE were observed in vitro and in transcranial human investigations. These signals were characterized by a mosaic of color Doppler pixels ranging over the full color scale. Apparent velocity information and spatial distribution of SAE signals changed from image frame to image frame. In the experimental model, the intensity of SAE signals decreased exponentially over time. With an increase of acoustic power, there was a significant increase of the maximum signal intensity (P<0.01) and a significantly shortened signal duration (P<0.01), consistent with stronger and more rapid disintegration. In humans, SAE signals were clearly detected in cerebral tissue regions. The intensity of SAE signals in those regions (eg, temporal cortex, 3.7+/-1.2 dB) was approximately 8 times lower than the signal enhancement in the major cerebral arteries (eg, in the MCA, 29.5+/-5.6). CONCLUSIONS: Echo-contrast specific color Doppler signals known as SAE are detectable by transcranial color and power Doppler sonography. Signals due to SAE might represent tissue perfusion, thereby providing a method for imaging flow with transcranial ultrasound.

Adult↗

Previous infection and other risk factors for acute cerebrovascular ischaemia: attributable risks and the characterisation of high risk groups.

BACKGROUND: Recent reports indicated that previous infection may be a risk factor for ischaemic stroke in younger adults and that the increased mortality of cerebrovascular diseases in winter months may be partly caused by the increased rate of infection during the cold season. METHODS: We performed a 1:1 matched case-control study with 197 cases (83 females, 114 males) aged between 22 and 80 years (median age 65 years) to investigate risk factors for acute cerebrovascular ischaemia, in particular the effect of previous infection. We estimated the impact of risk factors in terms of attributable and absolute risks. RESULTS: All risk factors together, previous infection, hypertension, diabetes mellitus, smoking, coronary heart disease, previous stroke or transient ischaemic attack and family history of stroke yield a summary attributable risk of 0.74 [95% confidence intervals (CI) 0.64-0.83]. Recent infections showed a relative risk of 4.3 (95% CI 1.8-10.5) and an attributable risk of 0.15 (95% CI 0.09-0.21). Seventeen percent of the German population are estimated to be in a high-risk group. This subgroup contributes about 55% of the estimated yearly 120,000 incident cases in the age group 55-84 in Germany. DISCUSSION: Identification of high-risk groups for stroke on the basis of individual risk factor distribution and the estimation of its size is possible and may produce useful results. Reducing the prevalence of infection and early treatment of bacterial infection may lower the incidence of stroke.

Adult↗

Right atrial appendage thrombosis in atrial fibrillation: its frequency and its clinical predictors.

This study assesses the incidence of right atrial (RA) chamber and appendage thrombosis in patients with atrial fibrillation (AF) in relation to RA appendage morphology and function. Transthoracic and multiplane transesophageal echocardiography were performed in 102 patients with AF to assess the incidence of RA and left atrial (LA) thrombi and spontaneous echo contrast. Both right and left ventricular sizes, atrial chamber and appendage sizes and function were measured. Twenty-two patients in sinus rhythm served as the control group (SR). Complete visualization of the RA appendage was feasible in 90 patients with AF. Patients with AF had lower tricuspid annular excursion (p = 0.008) and larger RA chamber area (p = 0.0001) than patients in SR. In addition, RA appendage areas were larger (p <0.05) and RA ejection fraction and peak emptying velocities (both p <0.0001) were lower in patients with AF patients than in those in SR. Equivalent differences were found for the LA appendage. Six thrombi were found in the RA appendage and 11 thrombi in the LA appendage in AF patients. Spontaneous echo contrast was found in 57% and 66% in the right atrium and in the left atrium, respectively. AF patients with RA appendage thrombi had a larger RA area (p = 0.0001), and lower RA appendage ejection fraction and emptying velocities (both p = 0.0001) than patients without thrombi. Spontaneous echo contrast was detected in all patients with thrombi. Spontaneous echo contrast was the only independent predictor of RA (p = 0.03) and LA appendage thrombosis (p = 0.036). In conclusion, multiplane transesophageal echocardiography allows the assessment of RA appendage morphology and function. RA spontaneous echo contrast is the only independent predictor of RA appendage thrombosis.

Adult↗

In vitro, animal, and human characterization of OPTISON infusions for myocardial contrast echocardiography.

UNLABELLED: Traditionally, performing myocardial contrast echocardiography with OPTISON required maximal bolus dosing. However, sustained and consistent opacification of the myocardium would be preferable for perfusion imaging. METHODS: Images of 5 anesthetized dogs and 6 human volunteers were obtained with a second harmonic ultrasound system during bolus administration of OPTISON and 2 infusion techniques. One infusion technique used diluted OPTISON, and the other used the buoyant properties of OPTISON microspheres by placing the contrast agent between an infusion source and the intravenous site in a vertically oriented extension line (ELT). Myocardial intensities and in vitro microsphere characteristics were analyzed to assess the consistency of microsphere delivery over time. RESULTS: In addition to providing higher myocardial opacification intensity than diluted infusions, ELT infusions provided consistent microsphere concentration, phantom enhancement, and near-peak bolus-level myocardial opacification for 7 to 15 minutes. The myocardial intensity at 3 and 5 minutes in human subjects during ELT infusions (30 mL/h; 2.5 mL) was lower (220 arbitrary units [au] and 165 au, respectively) but not significantly different (P =.3 and.1, respectively) than the peak myocardial intensity (265 au) after bolus administration. CONCLUSION: This new ELT infusion method provides an acceptable alternative to bolus administration of OPTISON for prolonged myocardial opacification.

Adult↗

Imaging of thrombi and assessment of left atrial appendage function: a prospective study comparing transthoracic and transoesophageal echocardiography.

OBJECTIVE: To compare the value of current transthoracic echocardiographic systems and transoesophageal echocardiography for assessing left atrial appendage function and imaging thrombi. DESIGN: Single blind prospective study. Patients were first investigated by transthoracic echocardiography and thereafter by a second investigator using transoesophageal echocardiography. The feasibility of imaging the left atrial appendage, recording its velocities, and identifying thrombi within the appendage were determined by both methods. PATIENTS: 117 consecutive patients with a stroke or transient neurological deficit. SETTING: Tertiary cardiac and neurological care centre. RESULTS: Imaging of the complete appendage was feasible in 75% of the patients by transthoracic echocardiography and in 95% by transoesophageal echocardiography. Both methods were concordant for the detection of thrombi in 10 cases. Transoesophageal echocardiography revealed two additional thrombi. In one of these patients, transthoracic echocardiography was not feasible and in the other the thrombus had been missed by transthoracic examination. In patients with adequate transthoracic echogenicity, the specificity and sensitivity of detecting left atrial appendage thrombi were 100% and 91%, respectively. Recording of left atrial appendage velocities by transthoracic echocardiography was feasible in 69% of cases. None of the patients with a velocity > 0.3 m/s had left atrial appendage thrombi. In the one patient in whom transthoracic echocardiographic evaluation missed a left atrial appendage thrombus, the peak emptying velocity of the left atrial appendage was 0.25 m/s. CONCLUSIONS: A new generation echocardiographic system allows for the transthoracic detection of left atrial appendage thrombi and accurate determination of left atrial appendage function in most patients with a neurological deficit.

Adult↗

Risk estimation as a decision-making tool for genetic analysis of the breast cancer susceptibility genes. EC Demonstration Project on Familial Breast Cancer.

For genetic counselling of a woman on familial breast cancer, an accurate evaluation of the probability that she carries a germ-line mutation is needed to assist in making decisions about genetic-testing. We used data from eight collaborating centres comprising 618 families (346 breast cancer only, 239 breast or ovarian cancer) recruited as research families or counselled for familial breast cancer, representing a broad range of family structures. Screening was performed in affected women from 618 families for germ-line mutations in BRCA1 and in 176 families for BRCA2 mutations, using different methods including SSCP, CSGE, DGGE, FAMA and PTT analysis followed by direct sequencing. Germ-line BRCA1 mutations were detected in 132 families and BRCA2 mutations in 16 families. The probability of being a carrier of a dominant breast cancer gene was calculated for the screened individual under the established genetic model for breast cancer susceptibility, first, with parameters for age-specific penetrances for breast cancer only [7] and, second, with age-specific penetrances for ovarian cancer in addition [20]. Our results indicate that the estimated probability of carrying a dominant breast cancer gene gives a direct measure of the likelihood of detecting mutations in BRCA1 and BRCA2. For breast/ovarian cancer families, the genetic model according to Narod et al. [20] is preferable for calculating the proband's genetic risk, and gives detection rates that indicate a 50% sensitivity of the gene test. Due to the incomplete BRCA2 screening of the families, we cannot yet draw any conclusions with respect to the breast cancer only families.

Adult↗

[Improved endocardium imaging using modified transthoracic echocardiography with the second harmonic frequency (tissue harmonic imaging)].

UNLABELLED: In human tissue sound propagation is not linear resulting in a modification of the ultrasound waves. Therefore the received ultrasound frequencies are not just the transmitted frequencies of the transducer, but contain additional harmonic frequencies. These frequencies were not used by standard echocardiography. Harmonic imaging processes the second harmonic frequency. Distortion of the transmitted beam by shallow surface layers or reverberations between the skin surface and ribs impair image quality in conventional 2-dimensional echocardiography. Since harmonic components develop with propagation distance, the reverberations are almost entirely made up of ultrasound energy at the fundamental frequency. The exclusive processing of the second harmonic frequency provides an impressive improvement in image quality of 2-dimensional echocardiograms. Noise and clutter artifacts are reduced and endocardial borders are enhanced. Commercially available imagers provide tissue harmonic imaging using transmit frequencies from 1.7 to 2.1 MHz and second harmonic frequencies between 3.4 and 4.2 MHz. Several clinical studies have shown that harmonic imaging was superior to standard echocardiography in the assessment of left ventricular (LV) wall motion by LV wall motion analysis. In patients with poor acoustic windows the number of myocardial segments which could be evaluated was significantly higher using harmonic imaging than standard echocardiography. Tissue harmonic imaging particularly improves the delineation of the anterior wall using the 2-chamber view and the lateral wall using the 4-chamber view. CONCLUSION: Harmonic imaging is a clinically relevant improvement of echocardiography. We suggest that this new technology should be the method of choice in the evaluation of LV function.

Artifacts↗

Breast cancer risk assessment: use of complete pedigree information and the effect of misspecified ages at diagnosis of affected relatives.

Reliable risk estimates for hereditary breast cancer are important for the genetic counseling of women who have one or more first- and/or second-degree relatives affected by the disease. If no mutation analysis of known high-penetrance breast cancer genes is performed, risk estimation is often based on published reference tables. These tables express a woman's age-specific risk of breast cancer as a function of the ages at diagnosis of one or two affected relatives with different degrees of relationship to the counselee. However, unaffected relatives are not taken into account when these estimates are derived. We report here the extent to which risk estimation is influenced by the number and ages of any unaffected relatives and by the exact genealogical relationship between the proband and affected relative rather than merely the degree. Additionally, we describe the sensitivity of risk estimates when ages at diagnosis of affected relatives are misspecified because of inaccurate information supplied by the counselee. We determined a proband's probability of being a carrier of a highly penetrant breast cancer susceptibility gene, such as BRCA1 or BRCA2, by likelihood calculations that take into account information from the entire pedigree. This genetic risk was used to estimate a phenotypic lifetime breast cancer risk, which was compared with the risks derived from the published reference tables. We demonstrate numerically that the tabulated values tend to over-estimate the probands risk and that the extent of over-estimation depends greatly on the number and ages of unaffected relatives. The validity of the relatives ages at diagnosis can affect risk predictions considerably in small families with two or three affected relatives. Furthermore, the magnitude of the estimated breast cancer risks depends upon the assumed genetic model and can therefore vary appreciably when different penetrance estimates are used.

Adult↗