Search PubMed⌕ Search

Biomedical subjects

H Baum

Publications and source records attributed to H Baum.

At least 19 recordsLinked to original sources

Extensive homology between the major immunodominant mitochondrial antigen in primary biliary cirrhosis and Helicobacter pylori does not lead to immunological cross-reactivity.

BACKGROUND: Primary biliary cirrhosis (PBC) is an immune-mediated chronic cholestatic disease characterized by the presence of antibodies directed predominantly against the E2 subunit of the pyruvate dehydrogenase complex (PDC-E2). What provokes tolerance breakdown in PBC remains to be established, though there is evidence to indicate that microbes may induce anti-mitochondrial antibodies (AMA) through a mechanism of molecular mimicry. METHODS: Having found that urease beta (UREB)(22-36) antigen of Helicobacter pylori (HELPY) shares extensive (87%) similarity with PDC-E2(212-226), the major mitochondrial autoepitope, it was hypothesized that this would also lead to cross-reactivity. The UREB/PDC-E2 mimics were thus constructed and tested by ELISA in 112 PBC patients and 114 controls. RESULTS: Reactivity to PDC-E2(212-226) was found in 104 patients but to UREB(22-36) in only 2. In these two patients, the double reactivity was not cross-reactive. The lack of surface antibody accessibility to UREB(22-36), as demonstrated through three-dimensional model prediction analysis, may explain this unexpected finding. There was some speculation on whether HELPY UREB(22-36) might act as a cross-reactive CD4 T-cell epitope. All seven PBC patients, tested in a standard proliferation assay against PDC-E2(212-226), gave a positive response. All seven were unresponsive to HELPY UREB(22-36). The pattern of reactivity to HELPY antigens by immunoblot was similar between anti-PDC-E2-positive and negative PBC cases, as well as between PBC patients and controls. CONCLUSION: Contrary to common belief, extensive sequence homology (molecular mimicry) between self and microbe does not necessarily result in cross-reactivity. It is therefore likely that, when present, cross-reactivity between self and microbes is of biological importance.

Adult↗

Association between the primary biliary cirrhosis specific anti-sp100 antibodies and recurrent urinary tract infection.

BACKGROUND AND AIMS: Recurrent urinary tract infections (rUTI) have been suggested to be involved in the induction of anti-mitochondrial antibodies (AMA), the serological hallmark of primary biliary cirrhosis (PBC), in view of the presence of AMA in rUTI women without liver disease and conversely of a high prevalence of rUTI in women with PBC. This prompted us to investigate whether PBC-specific anti-nuclear antibodies (ANA) to sp100, gp210 and lamin B receptor (LBR) antigens may also be related to rUTI. METHODS AND SUBJECTS: PBC-specific ANA reactivities were investigated in 20 women with rUTI but without liver disease, some of whom were AMA-seropositive; 40 women with PBC, with or without rUTI; and 104 pathological and 23 healthy controls. RESULTS: Among the women with rUTI but without liver disease, 8 (80%) of 10 AMA-positive women reacted with sp100 compared with none of the 10 AMA-negative women. Among the PBC patients, 14 (74%) of 19 with rUTI and 1 (4.8%) of the 21 without rUTI reacted with sp100. None of the rUTI women without liver disease reacted with gp210 or LBR. None of 127 pathological and healthy controls had PBC-specific ANA reactivity. CONCLUSIONS: Anti-sp100 reactivity strongly correlates with AMA seropositivity in rUTI women, with or without evidence of primary biliary cirrhosis. These findings provide additional support to the notion that E. coli infection is involved in the induction of PBC-specific autoimmunity. Additional factors must be involved in the progression to overt autoimmune disease.

Adult↗

Decreased Pasteur effect in platelets of aged individuals.

We have investigated the mitochondrial energy state in human platelets of young (19-30 years old) and aged individuals (65-87 years old) exploiting the Pasteur effect, i.e. stimulation of lactate production by incubation of the purified platelets with the mitochondrial respiratory chain inhibitor, antimycin A. This assay allows the determination of mitochondrial function with respect to glycolysis, and the ratio of mitochondrial adenosine triphosphate (ATP) to glycolytic ATP. A significant increase of basal, non-stimulated lactate production and decrease of the stimulation by antimycin A were observed in the older individuals, suggesting that the impairment of oxidative phosphorylation detectable in post-mitotic tissues of aged individuals can be observed also in easily collectable blood cells.

Adenosine Triphosphate↗

Effects of implantable cardioverter defibrillator implantation and shock application on biochemical markers of myocardial damage.

BACKGROUND: Implantable cardioverter defibrillator (ICD) implantation is a common approach in patients at high risk of sudden cardiac death. To check for normal function, it is necessary to test the ICD. For this purpose, repetitive induction and termination of ventricular fibrillation by direct current shocks is required. This may lead to minor myocardial damage. Cardiac troponin T (cTnT) and I (cTnI) are specific markers for the detection of myocardial injury. Because these proteins usually are undetectable in healthy individuals, they are excellent markers for detecting minimal myocardial damage. The objective of this study was to evaluate the effect of defibrillation of induced ventricular fibrillation on markers of myocardial damage. METHODS: This study included 14 patients who underwent ICD implantation and intraoperative testing. We measured cTnT, cTnI, creatine kinase MB (CK-MB) mass, CK activity, and myoglobin before and at definite times after intraoperative shock application. RESULTS: Depending on the effectiveness of shocks and the energy applied, the cardiac-specific markers cTnT and cTnI, as well as CK-MB mass, showed a significant increase compared with the baseline value before testing and peaked for the most part 4 h after shock application. In contrast, the increases in CK activity and myoglobin were predominantly detectable in patients who received additional external shocks. CONCLUSIONS: ICD implantation and testing leads to a short release of cardiac markers into the circulation. This release seems to be of cytoplasmic origin and depends on the number and effectiveness of the shocks applied.

Adult↗

Detection limit, cut-off and specificity of an improved rapid assay for cardiac troponin T.

The performance of an improved version of the troponin T rapid test TROPT Sensitive was investigated in a multicentre evaluation at twelve centres. The detection limit and the cut-off were determined in a method comparison with Elecsys Troponin T using a total of 365 samples from patients with suspected acute coronary syndromes and 91 samples from healthy blood donors or non-cardiological patients. The analytical specificity was determined by measuring 1271 blood samples from blood donors without any myocardial injury. The test cut-off (90% of results positive) is 0.08 microg/L, and the detection limit is about 0.05 microg/L. The analytical specificity of the test is between 99.7 and 99.9%. With its small area of undefined significance between positive and negative results and its high sensitivity and specificity, TROPT Sensitive is very well suited to the reliable detection of troponin T positive patients with acute coronary syndromes.

Biomarkers↗

Cardiac troponin T and I in end-stage renal failure.

BACKGROUND: In patients suffering from end-stage renal failure, cardiac troponin T (cTnT) and I (cTnI) may be increased in serum without other signs of acute myocardial damage. Whether these increases are specific to myocardial injury or nonspecific is not completely clear. METHODS: We investigated time courses of cTnT and cTnI over 1 year and the clinical outcome over 2 years in 59 patients with end-stage renal failure undergoing chronic hemodialysis. At the start of the study, we divided the patients into two groups, group 1, without history of cardiac failure, and group 2, with history of cardiac failure, and looked for differences between the groups in later adverse outcome. cTnT was measured using the Enzymun((R)) troponin T assay on an ES 700 analyzer (Roche). cTnI was measured on a Stratus((R)) II analyzer (Dade Behring). Creatinine and blood urea nitrogen were measured on a Vitros((R)) 950 IRC (Ortho). RESULTS: Dialysis acutely increased cTnT (P: <0.01) and decreased cTnI (P: <0.001) regardless of the dialysis membrane used. Although statistically not significant, cTnT but not cTnI was increased more frequently in group 2 than in group 1, in some cases over the whole study period. Five patients (8.5%) died of cardiac complications within 2 years; all of them had mostly increased cTnT and, in one or more samples, increased cTnI. CONCLUSIONS: Dialysis alters measured cTnT and cTnI concentrations in serum. In patients suffering from end-stage renal failure, sporadic or persistently increased cTnT and cTnI appear to predict cardiac complications. Because of the effects of the dialysis procedure on troponin values, we recommend that blood be collected before dialysis.

Humans↗

Expression of messenger RNA of the cardiac isoforms of troponin T and I in myopathic skeletal muscle.

In the absence of clinical signs, elevated values of the cardiac isoforms of troponin T (cTnT) and I (cTnI) can be found in the serum samples of some patients with skeletal muscle myopathies; the cause is unclear. We studied the messenger RNA (mRNA) expression of cTnT and cTnI in the skeletal muscles of 24 patients with histologically proven myopathies and in 18 patients in whom a myopathy could be excluded. For cTnT- and cTnI-mRNA determination, we designed specific primer pairs for nested polymerase chain reaction. After amplification, the products were digested with 2 restriction enzymes and visualized. We found cTnT mRNA in 7 skeletal muscle biopsy specimens (6 patients with Duchenne muscular dystrophy, 1 patient with a primary sarcoglycanopathy) and cTnI mRNA in 6 (5 with Duchenne muscular dystrophy, 1 patient with a histologically negative biopsy). The mRNA of the cardiac isoforms, cTnT and cTnI, is expressed in the skeletal muscles of patients with Duchenne muscular dystrophy, but also in some other myopathies. Further studies are needed to show whether the mRNA is translated into the protein, but serum levels of cTnT and cTnI in patients with Duchenne muscular dystrophy would seem to indicate this.

Biomarkers↗

Lipoprotein(a) and coronary thrombosis and restenosis after stent placement.

OBJECTIVES: The objective of this prospective study was to evaluate the relation between high lipoprotein(a) levels and thrombotic and restenotic events after coronary stent implantation. BACKGROUND: Lipoprotein(a) may promote atherogenesis, coronary thrombosis and restenosis after balloon angioplasty, but the clinical significance remains unclear. METHODS: The study included 2,223 consecutive patients with successful coronary stent placement. According to the serum level of lipoprotein(a), patients were divided in two groups: 457 patients of the highest quintile formed the high lipoprotein(a) group, and 1,766 patients of the lower four quintiles formed the low lipoprotein(a) group. Primary end points were the incidence of angiographic restenosis at six months and the event-free survival at one year. Secondary end point was the incidence of angiographic stent occlusion. RESULTS: Early stent occlusion occurred in four of the 457 patients (0.9%) with high and 37 of the 1,766 patients (2.1%) with low lipoprotein(a) levels, odds ratio of 0.41 (95% confidence interval, 0.15 to 1.16). Angiographic restenosis occurred in 173 of the 523 lesions (33.2%) in the high lipoprotein(a) group and 636 of the 1,943 lesions (32.7%) in the low lipoprotein(a) group, odds ratio of 1.02 (0.83 to 1.25). The probability of event-free survival was 73.0% in the high lipoprotein(a) group and 74.8% in the low lipoprotein(a) group (p = 0.45). On the basis of the findings in the low lipoprotein(a) group, the power of this study to detect a 25% increase in the incidence of restenosis and adverse events in the group with elevated lipoprotein(a) was 90% and 75%, respectively. CONCLUSIONS: Elevated lipoprotein(a) levels did not influence the one-year clinical and angiographic outcome after stent placement. Thrombotic events and measures of restenosis were not adversely affected by the presence of high lipoprotein(a) levels.

Aged↗

Spontaneous T-cell proliferation in the non-obese diabetic mouse to a peptide from the unique class II MHC molecule, I-Ag7, which is also protective against the development of autoimmune diabetes.

AIMS/HYPOTHESIS: Major histocompatibility complex class II molecules present antigenic peptides to T-cells and have an important role in T-cell thymic education. The mechanism by which major histocompatibility complex alleles confer a high genetic risk for autoimmune diabetes is not known. One hypothesis is that during positive thymic selection, the peripheral T-cell repertoire is modelled by major histocompatibility complex-restricted presentation of self major histocompatibility complex molecule-derived peptides, some of which mimic tissue autoantigens. The sequence similarity between a known T-cell epitope of glutamic acid decarboxylase-65, 509:VPPSLRTLED and the non-obese diabetic mouse class II major histocompatibility complex molecule I-Ag7 86:VPTSLRRLEQ is consistent with this. METHODS: We measured spontaneous proliferation of peripheral T-cells from non-obese diabetic mice and other, non-diabetes-prone strains, to the I-Ag7 86-101 and glutamic acid decarboxylase-65(509-524) peptides, binding of these peptides to intact I-Ag7 and assessed the effect of tolerance induction on diabetes development, by injecting young non-obese diabetic mice with high doses of peptide. RESULTS: T-cells from non-obese diabetic, but not other mice strains, spontaneously proliferate to the I-Ag7 86-101 and glutamic acid decarboxylase-65(509-524) peptides, but not control peptides. Both test peptides bind I-Ag7. Tolerance induction prolongs diabetes-free survival in non-obese diabetic mice when either the I-Ag7 86-101 or glutamic acid decarboxylase-65(509-524) peptide, but not control peptide, is used. CONCLUSION/INTERPRETATION: A peptide from the unique class II major histocompatibility complex, diabetes-susceptibility molecule, I-Ag7, presented by I-Ag7 is a target of T-cell responses in diabetes-prone nonobese diabetic mice and tolerance induction against the peptide offers appreciable protection against the development of diabetes.

Amino Acid Sequence↗

A physical method for separating spermatozoa from epithelial cells in sexual assault evidence.

The analysis of genetic markers for the purpose of individualization of semen specimens is extremely important in cases of sexual abuse and assault. The serological analysis of sexual assault evidence can sometimes be complicated because stains are often composed of a mixture of spermatozoa, vaginal epithelial cells and white and red blood cells. A filtration method has been developed to cleanly separate spermatozoa from epithelial cells based upon differences in size and shape. Nylon mesh filters of the appropriate pore size can be used to separate the smaller oval shaped spermatozoal cells from the larger and flatter epithelial cells. The former pass freely through the membrane while the latter are retained on the filter. In this study, cell separation was demonstrated by (a) microscopic observation of stained cells, (b) amplified fragment length polymorphism analysis of DNA obtained from separated cells. The results of these analyses indicate that: (1) Approximately 70% of spermatozoa in the mixed cell sample will penetrate the 10 microns pore size filter, (2) Only about 1-2% of intact epithelial cells will do so, and (3) A small number of nuclei from spontaneously lysed epithelial cells will cross the filter. Experimental results using mixtures of spermatozoa and vaginal epithelial cells prepared in different ratios support the conclusion that the filtration process is an efficient and reliable method to separate spermatozoa from epithelial cells in casework specimens for subsequent DNA analysis.

Autoradiography↗

Clinical performance of the new cardiac markers troponin T and CK-MB on the Elecsys 2010. A multicentre evaluation.

Elecsys assays for the cardiac markers Troponin T (cTnT) and CK-MB have been evaluated in an international multicenter study on the random access analyzer Elecsys 2010 to characterize their clinical performance and their comparability with respective established routine methods. In method comparison studies of Elecsys Troponin T (TnT) with Enzymun-Test TnT, good correlations (r > or = 0.95) and a high degree of correspondence (slopes in 4 laboratories between 0.95 and 1.05) were found. The method comparison studies of Elecsys CK-MB with various CK-MB routine methods lead to good correlations but some systematic deviation in the slopes due to varying standardization. In a reference population of 350 persons upper reference limits (97.5th percentile) of 0.03 milligrams/l for Elecsys TnT and 3.1 milligrams/l for Elecsys CK-MB were found. In cardiosensitivity studies the equivalent diagnostic information of the new Elecsys assays to routine methods was confirmed in the early diagnosis of acute myocardial infarction (AMI), the detection of minor myocardial damages in patients with unstable angina pectoris (UAP) and in time course data monitoring of AMI and bypass surgery patients. The superior sensitivity of cTnT versus CK-MB has been established in a screening situation where in 29 patients with cardiac diseases only cTnT, but not CK-MB, was found pathologically increased; this was due either to the larger diagnostic window of cTnT in AMI or to the more sensitive recognition of minor myocardial damage. In the same study, the cardiospecificity of Elecsys TnT was found to be at least 99.5%. This has also been demonstrated in an earlier study for Enzymun-Test TnT. Further cardiospecificity testing, e.g. in renal failure patients, showed results equivalent to those of Enzymun-Test TnT. An extended clinical study involving 294 patients with chest pain, of whom 58 had a final diagnosis of AMI, revealed highly comparable sensitivity and specificity for the Elecsys assays and routine methods. Thus, the already recommended clinical cut-off values of 0.1 milligrams/l for cTnT and 5 milligrams/l for CK-MB are also valid for the Elecsys assays. The slightly improved sensitivity of Elecsys TnT in the lower range even allows the recognition of pathological increase at cTnT concentrations below 0.1 milligrams/l in special situations with sufficient additional clinical information. Summarizing, provide the two cardiac markers on the Elecsys 2010 at least equivalent or even superior diagnostic information in various clinical situations of cardiac disease compared with routine methods. The short turn-around time and reliable performance qualify the Elecsys assays as new methods of choice for routine and emergency use.

Adult↗

Multiplexing of Y chromosome specific STRs and performance for mixed samples.

A combination of four Y-specific polymorphic STR loci was amplified simultaneously using fluorescently labeled primers. Multiplex conditions required optimization to eliminate constant bands and amplification products for female DNA. A series of experiments was carried out for mixtures of DNA from two males, and from male and female individuals for the Y-specific STRs and an autosomal locus. For the male/male mixtures amplified with the Y specific system, and amplified for an autosomal locus, the minor component in the mixture could only be identified up to a ratio of 1:10, 1:50 respectively. In male/female DNA mixtures the Y STR alleles could be identified for the highest ratio tested, 400 pg male in DNA in 800 ng female DNA which amounts to a ratio of 1:2000.

Alleles↗

Also ...

Explore the source record for details and available documents.

Animals↗

Evaluation of a rapid, quantitative cardiac troponin I immunoassay.

We evaluated a rapid, quantitative immunoassay for the detection of cardiac troponin I. Coefficient of variation is between 1.29 and 13.63% for intra-assay and between 3.88 and 10.15% for inter-assay imprecision. Linearity is given up to 35 micrograms/l. Possible interfering substances (haemoglobin, bilirubin, triacylglycerol and rheuma factors) do not disturb the assay. The analyte is stable under normal storage conditions (+20 degrees C/48 h and +4 degrees C/l week) with decrease up to 30% after 3 months at -20 degrees C. Reference value for apparently healthy individuals is < 0.1 microgram/l. In plasma cardiac troponin I is measured up to 30% depressed compared to serum. Comparison with another cardiac troponin I assay (y = 0.92x + 2.42, r = 0.940) and cardiac troponin T is good with y = 6.61x - 1.94, r = 0.91 for the first generation cardiac troponin T assay and y = 5.59x - 0.68, r = 0.87 for the second generation cardiac troponin T assay. In summary, the evaluated assay is fast, easy to perform, and can be used not only in a specialized laboratory, but is also suitable for emergency laboratory or smaller laboratory units.

Drug Stability↗