Search PubMed⌕ Search

Biomedical subjects

H B Li

Publications and source records attributed to H B Li.

At least 19 recordsLinked to original sources

Search for invisible decays of eta and eta' in J/psi --> phi eta and phi eta'.

Using a data sample of 58 x 10(6) J/psi decays collected with the Beijing Spectrometer II detector at the Beijing Electron Positron Collider, searches for invisible decays of eta and eta' in J/psi to phi eta and phi eta' are performed. The phi signals, which are reconstructed in K+K- final states, are used to tag the eta and eta' decays. No signals are found for the invisible decays of either eta or eta', and upper limits at the 90% confidence level are determined to be 1.65 x 10(-3) for the ratio B(eta-->invisible)/B(eta --> gamma gamma) and 6.69 x 10(-2) for B(eta' --> invisible)/B(eta' --> gammagamma). These are the first searches for eta and eta' decays into invisible final states.

Journal Article↗

Observation of a broad 1-- resonant structure around 1.5 GeV/c2 in the K+K- mass spectrum in J/psi-->K+K-pi0.

A broad peak is observed at low K+K- invariant mass in J/psi-->K+K-pi(0) decays found in a sample of 5.8x10(7) J/psi events collected with the BESII detector. The statistical significance of the broad resonance is much larger than 5sigma. A partial wave analysis shows that the J;{PC} of this structure is 1--. Its pole position is determined to be [1576(-55)(+49)(stat)-91+98(syst)] MeV/c(2)-i/2[818(-23)(+22)(stat)-133+64(syst)] MeV/c(2). These parameters are not compatible with any known meson resonances.

Journal Article↗

Measurements of the branching fractions for psi(3770)-->D(0)D[over ](0), D+D-, DD[over ], and the resonance parameters of psi(3770) and psi(2S).

We measure the branching fractions for psi(3770)-->D(0)D[over ](0), D+D-, DD[over ], and non-DD[over ] to be (46.7+/-4.7+/-2.3)%, (36.9+/-3.7+/-2.8)%, (83.6+/-7.3+/-4.2)%, and (16.4+/-7.3+/-4.2)%, respectively. The resonance parameters of psi(3770) and psi(2S) are measured to be M_(psi(3770))=3772.2+/-0.7+/-0.3 MeV, Gamma_(psi(3770))(tot)=26.9+/-2.4+/-0.3 MeV, and Gamma_(psi(3770))(ee)=251+/-26+/-11 eV; M_(psi(2S))=3685.5+/-0.0+/-0.3 MeV, Gamma_(psi(2S))(tot)=331+/-58+/-2 keV, and Gamma_(psi(2S))(ee)=2.330+/-0.036+/-0.110 keV. We also measure the light hadron R value to be R(uds)=2.262+/-0.054+/-0.109 in the energy region from 3.660 to 3.872 GeV.

Journal Article↗

Observation of two new N* peaks in J/psi-->ppi-n and ppi+n decays.

The decay J/psi-->NNpi provides an effective isospin 1/2 filter for the piN system due to isospin conservation. Using 58x10(6) J/psi decays collected with the Beijing Electromagnetic Spectrometer at the Beijing Electron Positron Collider, more than 100 thousand J/psi-->ppi-n+c.c. events are obtained. Besides the two well-known N* peaks at around 1500 MeV/c2 and 1670 MeV/c2, there are two new, clear N* peaks in the ppi invariant mass spectrum around 1360 MeV/c2 and 2030 MeV/c2 with statistical significance of 11sigma and 13sigma, respectively. We identify these as the first direct observation of the N*(1440) peak and a long-sought missing N* peak above 2 GeV/c2 in the piN invariant mass spectrum.

Journal Article↗

Observation of a near-threshold enhancement in the omega(phi) mass spectrum from the doubly OZI-suppressed decay J/psi-->gamma(omega)phi.

An enhancement near threshold is observed in the omega(phi) invariant mass spectrum from the doubly Okubo-Zweig-Iizuka-suppressed decays of J/psi-->gamma(omega)phi, based on a sample of 5.8 x 10(7) J/psi events collected with the BESII detector. A partial wave analysis shows that this enhancement favors JP=0+, and its mass and width are M=1812(+19)(-26)(stat)+/-18(syst) MeV/c2 and Gamma=105+/-20(stat)+/-28(syst) MeV/c2. The product branching fraction is determined to be B(J/psi-->gammaX)B(X-->omega(phi))=[2.61+/-0.27(stat)+/-0.65(syst)]x10(-4).

Journal Article↗

Observation of a resonance in Chi(1835) in J/psi --> gammapi+ pi- eta-.

The decay channel J/psi --> gamma(pi)(+)pi(-)eta is analyzed using a sample of 5.8 x 10(7) J/psi events collected with the BESII detector. A resonance, the Chi(1835), is observed in the pi(+)pi(-)eta invariant-mass spectrum with a statistical significance of 7.7 sigma. A fit with a Breit-Wigner function yields a mass M = 1833.7 +/- 6.1(stat) +/- 2.7(syst) MeV/c(2), a width Tau = 67.7 +/- 20.3(stat) +/- 7.7(syst) MeV/c(2), and a product branching fraction B(J/psi --> gammaChi) . B(Chi --> pi(+)pi(-)eta) = [2.2 +/- 0.4(stat) +/- 0.4(syst)] x 10(-4). The mass and width of the Chi(1835) are not compatible with any known meson resonance. Its properties are consistent with expectations for the state that produces the strong pp mass threshold enhancement observed in the J/psi --> gammapp process at BESII.

Journal Article↗

Limit on the electron neutrino magnetic moment from the kuo-sheng reactor neutrino experiment.

A search of neutrino magnetic moment was carried out at the Kuo-Sheng Nuclear Power Station at a distance of 28 m from the 2.9 GW reactor core. With a high purity germanium detector of mass 1.06 kg surrounded by scintillating NaI(Tl) and CsI(Tl) crystals as anti-Compton detectors, a detection threshold of 5 keV and a background level of 1 kg(-1) keV(-1) day(-1) at 12-60 keV were achieved. Based on 4712 and 1250 h of reactor ON and OFF data, respectively, the limit on the neutrino magnetic moment of mu(nu;(e))<1.3x10(-10)mu(B) at 90% confidence level was derived. An indirect bound of the nu;(e) radiative lifetime of m(3)(nu)tau(nu)>2.8x10(18) eV(3) s can be inferred.

Journal Article↗

Preparative isolation and purification of salidroside from the Chinese medicinal plant Rhodiola sachalinensis by high-speed counter-current chromatography.

High-speed counter-current chromatography was applied to the isolation and purification of salidroside from the Chinese medicinal plant Rhodiola sachalinensis A. Bor. The crude salidroside was obtained by extraction with methanol from Rhodiola sachalinensis A. Bor. Preparative high-speed counter-current chromatography with a two-phase solvent system composed of n-butanol-ethyl acetate-water (2:3:5, v/v) was successfully performed yielding salidroside (32 mg) at 98% purity from 250 mg of the crude extract in a one-step separation.

Chromatography, High Pressure Liquid↗

Preparative isolation and purification of astaxanthin from the microalga Chlorococcum sp. by high-speed counter-current chromatography.

High-speed counter-current chromatography was applied to the isolation and purification of astaxanthin from microalgae. The crude astaxanthin was obtained by extraction with organic solvents after the astaxanthin esters were saponified. Preparative high-speed counter-current chromatography with a two-phase solvent system composed of n-hexane-ethyl acetate-ethanol-water (5:5:6.5:3, v/v) was successfully performed yielding astaxanthin at 97% purity from 250 mg of the crude extract in a one-step separation.

Chlorophyta↗

Preparative isolation and purification of six diterpenoids from the Chinese medicinal plant Salvia miltiorrhiza by high-speed counter-current chromatography.

A high-speed counter-current chromatography (HSCCC) method was developed for the preparative separation and purification of six diterpenoids. dihydrotanshinone I, cryptotanshinone, methylenetanshiquinone, tanshinone I, tanshinone IIA and danshenxinkun B from the Chinese medicinal plant Salvia miltiorrhiza Bunge. The crude diterpenoids were obtained by extraction with ethanol-n-hexane (1:1, v/v) from S. miltiorrhiza Bunge. Preparative HSCCC with the two-phase solvent systems A composed of n-hexane-ethanol-water (10:5.5:4.5, v/v) and B composed of n-hexane-ethanol-water (10:7:3, v/v) was successfully performed in a stepwise elution yielding six relatively pure diterpenoids from 300 mg of the crude extract in a single run. The purities of dihydrotanshinone I, cryptotanshinone, methylenetanshiquinone, tanshinone I, tanshinone IIA and danshenxinkun B were 88.1, 98.8, 97.6, 93.5, 96.8 and 94.3%, respectively.

Chromatography, High Pressure Liquid↗

Determination of iodide in seawater and urine by size exclusion chromatography with iodine-starch complex.

A novel method for the determination of iodide by size exclusion chromatography was established. The method was simple and highly sensitive with good precision. Iodide was converted to iodine, then sequestered with starch, and separated from the matrix using a Shim-pack DIOL-150 (250 x 7.9 mm) size exclusion column with methanol-0.01 mol l(-1) aqueous phosphoric acid (10:90, v/v) as mobile phase at 1.2 ml min(-1) and UV detection at 224 nm. The calibration graph was linear from 1.0 ng ml(-1) to 100.0 ng ml(-1) for iodide with a correlation coefficient of 0.9992 (n=6). The detection limit was 0.2 ng ml(-1). The method was successfully applied to the determination of iodide in seawater and urine. The recovery was from 92% to 103% and the relative standard deviation was in the range of 1.5% to 3.7%.

Calibration↗

Preparative isolation and purification of lutein from the microalga chlorella vulgaris by high-speed counter-current chromatography.

High-speed counter-current chromatography (HSCCC) was applied to the isolation and purification of lutein from microalgae. Analytical HSCCC was used for the preliminary selection of a suitable solvent system composed of n-hexane-ethanol-water (4:3:1, v/v). Using the above solvent system, preparative HSCCC was successfully performed yielding lutein at 98% purity from 200 mg of the crude extract in a one-step separation.

Chlorella↗

Ramification amplification: a novel isothermal DNA amplification method.

We have developed a novel isothermal DNA amplification method with an amplification mechanism quite different from conventional PCR. This method uses a specially designed circular probe (C-probe) in which the 3' and 5' ends are brought together in juxtaposition by hybridization to a target. The two ends are then covalently linked by a T4 DNA ligase in a target-dependent manner, producing a closed DNA circle. In the presence of an excess of primers (forward and reverse primers), a DNA polymerase extends the bound forward primer along the C-probe and displaces the downstream strand, generating a multimeric single-stranded DNA (ssDNA), analogous to the "rolling circle" replication of bacteriophages in vivo. This multimeric ssDNA then serves as a template for multiple reverse primers to hybridize, extend, and displace downstream DNA, generating a large ramified (branching) DNA complex. This ramification process continues until all ssDNAs become double-stranded, resulting in an exponential amplification that distinguishes itself from the previously described nonexponential rolling circle amplification. In this report, we prove the principle of ramification amplification. By using a unique bacteriophage DNA polymerase, Ø29 DNA Polymerase, that has an intrinsic high processivity, we are able to achieve significant amplification within 1 hour at 35 degrees C. In addition, we applied this technique for in situ detection of Epstein-Barr viral sequences in Raji cells.

Cell Line↗

Determination of vitamin B12 in multivitamin tablets and fermentation medium by high-performance liquid chromatography with fluorescence detection.

A novel method for the determination of vitamin B12 by high-performance liquid chromatography with fluorescence detection is reported. The method was simple and highly sensitive with good precision. Vitamin B12 was analyzed by HPLC on a muBondapak C18 column (300x3.9 mm, 10 microm) with methanol-water (30:70) as mobile phase and fluorescence detection at 305 nm (with excitation at 275 nm). The calibration graph was linear from 1.000 to 100.0 ng ml(-1) for vitamin B12 with a correlation coefficient of 0.998 (n=6). The detection limit was 0.1 ng ml(-1). The method was successfully applied to the determination of vitamin B12 in vitamin B12 tablets, multivitamin tablets and fermentation medium. The recovery was from 94 to 102% and the relative standard deviation was in the range of 1.8 to 4.1%.

Chromatography, High Pressure Liquid↗

Determination of silicate in water by ion exclusion chromatography with conductivity detection.

A novel method for the direct determination of silicate in water by ion exclusion chromatography with conductivity detection is reported. The method is simple and sensitive with good precision. The calibration graph was linear from 0.1000 micromol l(-1) to 1000.0 micromol l(-1) for silicate with a correlation coefficient of 0.997 (n=6). The detection limit was 0.02 micromol l(-1). The method was successfully applied to the determination of silicate in mineral water, tap water, distilled water and seawater. The recovery was from 93 to 104% and the relative standard deviation was in the range of 1.1 to 4.4%.

Calibration↗

Fluorimetric determination of methylmercury as an ion-association complex with rhodamine B in the presence of iodide.

A fluorimetric method for the determination of methylmercury was established. The method was based on the formation of an ionic pair between iodide-methylmercury-rhodamine B in hydrochloric acid, which can be extracted with benzene. The fluorescence emission was measured at lambda(ex)/lambda(em) 575/590 nm, and the experimental variables and possible interference were studied. The linear calibration range was 4 x 10(-8) mol/L to approximately 5 x 10(-7) mol/L with a correlation coefficient of 0.9992. The detection limit was 1 x 10(-8) mol/L. The method was used to determine methylmercury in human hair. The recovery was in the range of 91% to 105% and the relative standard deviation was 2.8%. The results agreed with those obtained by gas chromatography with electron capture detection.

Calibration↗

A highly sensitive fluorimetric method for the determination of fluoride in biological material with Al3+-calcein complex.

A highly sensitive fluorimetric method for the determination of fluoride was established. The method was based on quenching of the fluorescence of the Al3+-calcein complex in CCl3COOH-CH3COOK buffer solution by fluoride. The fluorescence emission was measured at lambdaex/lambdaem 480/503 nm, and the experimental variables and interference in this determination were studied. The linear calibration range was 0.8 ng/mL to 150 ng/mL and the detection limit was 0.2 ng/mL. The method was applied to determine fluoride in biological materials. The recovery was in the range of 96.3% to 104.7% and the relative standard deviation was 4.6%. The results obtained from the certified reference material by the present method agreed with the certified values.

Aluminum↗