Search PubMed⌕ Search

Biomedical subjects

H A Padmore

Publications and source records attributed to H A Padmore.

9 recordsLinked to original sources

Shear at twin domain boundaries in YBa2Cu3O7-x.

The microstructure and strain state of twin domains in YBa2Cu3O7-x are discussed based upon synchrotron white-beam x-ray microdiffraction measurements. Intensity variations of the fourfold twin splitting of Laue diffraction peaks are used to determine the twin domain structure. Strain analysis shows that interfaces between neighboring twin domains are strained in shear, whereas the interior of these domains are regions of low strain. These measurements are consistent with the orientation relationships of twin boundaries within and across domains and show that basal plane shear stresses can exceed 100 MPa where twin domains meet. Our results support stress field pinning of magnetic flux vortices by twin domain boundaries.

Journal Article↗

Vortex core-driven magnetization dynamics.

Time-resolved x-ray imaging shows that the magnetization dynamics of a micron-sized pattern containing a ferromagnetic vortex is determined by its handedness, or chirality. The out-of-plane magnetization in the nanometer-scale vortex core induces a three-dimensional handedness in the planar magnetic structure, leading to a precessional motion of the core parallel to a subnanosecond field pulse. The core velocity was an order of magnitude higher than expected from the static susceptibility. These results demonstrate that handedness, already well known to be important in biological systems, plays an important role in the dynamics of microscopic magnets.

Journal Article↗

Metal-insulator transitions in an expanding metallic fluid: particle formation kinetics.

Core-level photoemission spectroscopy provides a local probe of expansion dynamics and associated transient chemical properties as a highly pressurized, metallic fluid expands into vacuum following impulsive heating of a semiconductor by an intense, ultrashort laser pulse. Transient photoemission peak shifts reveal that metal-insulator transitions occur rapidly following laser heating. These experiments probe constituents species and solidification kinetics occurring in the early moments of material ejection and provide insight into how particles arise in the current laser ablation regime.

Journal Article↗

Solving non-periodic structures using direct methods: phasing diffuse scattering.

The problem of reconstructing the charge density of a non-periodic sample from its diffuse X-ray scattering is considered. For a sample known to be isolated, an artificial superlattice may be assumed and the numerical direct methods of crystallography applied to the continuous distribution of diffuse scattering in order to solve the phase problem. This method is applied to simulated soft-X-ray transmission speckle patterns from a two-dimensional array of gold balls of 50 nm diameter. The results are relevant to efforts to phase the scattering from many individual macromolecules that cannot be crystallized, and to the scattering from individual inorganic nanoparticles.

Journal Article↗

Local plasticity of Al thin films as revealed by x-ray microdiffraction.

Grain-to-grain interactions dominate the plasticity of Al thin films and establish effective length scales smaller than the grain size. We have measured large strain distributions and their changes under plastic strain in 1.5-microm-thick Al 0.5% Cu films using a 0.8-microm-diameter white x-ray probe at the Advanced Light Source. Strain distributions arise not only from the distribution of grain sizes and orientation, but also from the differences in grain shape and from stress environment. Multiple active glide plane domains have been found within single grains. Large grains behave like multiple smaller grains even before a dislocation substructure can evolve.

Journal Article↗

Scanning X-ray microdiffraction with submicrometer white beam for strain/stress and orientation mapping in thin films.

Scanning X-ray microdiffraction (microSXRD) combines the use of high-brilliance synchrotron sources with the latest achromatic X-ray focusing optics and fast large-area two-dimensional-detector technology. Using white beams or a combination of white and monochromatic beams, this technique allows for the orientation and strain/stress mapping of polycrystalline thin films with submicrometer spatial resolution. The technique is described in detail as applied to the study of thin aluminium and copper blanket films and lines following electromigration testing and/or thermal cycling experiments. It is shown that there are significant orientation and strain/stress variations between grains and inside individual grains. A polycrystalline film when investigated at the granular (micrometer) level shows a highly mechanically inhomogeneous medium that allows insight into its mesoscopic properties. If the microSXRD data are averaged over a macroscopic range, results show good agreement with direct macroscopic texture and stress measurements.

Journal Article↗

Variable linear polarization from an X-ray undulator.

A new X-ray undulator has been designed and constructed which produces linearly polarized X-rays in which the plane of polarization can be oriented to a user selectable angle, from horizontal to vertical. Based on the Apple-II elliptically polarizing undulator (EPU), the undulator rotates the angle of the linear polarization by a simple longitudinal motion of the undulator magnets. Combined with the circular and elliptical polarization capabilities of the EPU operating in the standard mode, this new undulator produces soft X-ray radiation with versatile polarization control. This paper describes the magnetic structure of the device and presents an analysis of the magnetic field with varying undulator parameters. The variable linear polarization capability is then exhibited by measuring the X-ray absorption spectrum of an oriented polytetrafluoroethylene thin film. This experiment, which measures the linear dichroism of the sample at two peaks near the C 1s absorption edge, demonstrates the continuous polarization rotation capabilities of the undulator.

Journal Article↗

Studies of the magnetic structure at the ferromagnet-antiferromagnet interface.

Antiferromagnetic layers are a scientifically challenging component in magnetoelectronic devices, such as magnetic sensors in hard-disk heads, or magnetic random-access memory (RAM) elements. In this paper, it is shown that photoelectron emission microscopy (PEEM) is capable of determining the magnetic structure at the interface of ferromagnets and antiferromagnets with high spatial resolution (down to 20 nm). Dichroism effects at the L edges of the magnetic 3d transition metals, using circularly or linearly polarized soft X-rays from a synchrotron source, give rise to a magnetic image contrast. Images, acquired with the PEEM2 experiment at the Advanced Light Source, show magnetic contrast for antiferromagnetic LaFeO3, microscopically resolving the magnetic domain structure in an antiferromagnetically ordered thin film for the first time. Magnetic coupling between LaFeO3 and an adjacent Co layer results in a complete correlation of their magnetic domain structures. From field-dependent measurements, a unidirectional anisotropy resulting in a local exchange bias of up to 30 Oe in single domains could be deduced. The elemental specificity and the quantitative magnetic sensitivity render PEEM a perfect tool to study magnetic coupling effects in multilayered thin-film samples.

Journal Article↗

Soft X-ray Monochromators for Third-Generation Undulator Sources.

Over the past ten years, the resolving power from new designs of bending-magnet-based soft X-ray monochromators has increased by more than an order of magnitude. This has led to a revolution in soft X-ray spectroscopy, but the limited flux at this high resolution has allowed only relatively efficient measurements to be made, such as photo-absorption. Application of this new tool of high-resolution spectroscopy to photoemission, energy-resolved fluorescence spectroscopy and microscopy has now been made possible with the advent of undulator sources of soft X-rays. Here we have reviewed the recent development of undulator-based soft X-ray monochromators, the special features of undulators in general and the resulting benefits and problems, and describe the state of the art undulator beamline, 7.0 at the Advanced Light Source. In addition, we offer some speculation as to the possible routes to the next or ultimate generation of soft X-ray monochromator.

Journal Article↗