Liquid biopsy-based detection of circulating and exfoliated cholangiocarcinoma tumor cells from blood and bile using heparan sulfate octasaccharides on integrated microfluidic systems.

Early diagnosis of cholangiocarcinoma (CCA) remains challenging because existing diagnostic approaches often lack sufficient sensitivity for reliable detection of early-stage disease. Circulating tumor cells (CTCs) in blood and exfoliated tumor cells (ETCs) in bile represent valuable targets for liquid biopsy-based detection; however, their low abundance and the complexity of clinical sample analysis pose substantial technical challenges for reliable enrichment and identification. Herein, we present a reproducible workflow for isolating and identifying CCA tumor cells from blood for CTCs and bile for ETCs using synthetic cell-surface heparan sulfate (HS) octasaccharide-functionalized magnetic beads (MBs) on integrated microfluidic systems. The method combined sample pre-processing, magnetic bead-based enrichment, controlled low-shear mixing and immunofluorescence-based identification into a unified workflow compatible with distinct clinical sample types. Key operational parameters, including MB concentration, mixing frequency, and pressure settings, were detailed to facilitate consistent performance. Using this workflow, tumor cell capture rates of approximately 70% in bile (for ETCs) and blood (for CTCs) were achieved, with a total processing time of 60-90 min per sample under clinically relevant low-abundance conditions. The platform enables reliable detection of as few as 1 tumor cell per mL of blood or bile. This method provides a practical and adaptable strategy for glycosaminoglycan-mediated liquid biopsy applications and may be extended to other tumor-cell enrichment workflows involving heterogeneous cell-surface interactions.

Humans↗

Integrated reverse transcription polymerase chain reaction systems for virus detection.

The current study reports on an integrated microreverse transcription polymerase chain reaction (RT-PCR) system for molecular diagnosis of microorganisms automatically. By using antibodies-conjugated superparamagnetic beads, the developed system can detect viruses with higher sensitivity and specificity when compared with traditional biological diagnosis methods using a ribonucleic acid (RNA) extraction kit. The target viruses were first captured by the conjugated antibodies on the magnetic beads, and were enriched using a magnetic field generated by micro-electromagnets or permanent magnets. With this approach, the virus can be purified and concentrated first, then the virus RNA was extracted and transcripted to complementary deoxyribonucleic acid (cDNA), followed by a nucleic acid amplification process using a micro-RT-PCR module. The integrated microfluidic chip can perform the whole process automatically with the aid of integrated micropumps and microvalves. This study successfully performs the specific detection of two different types of viruses, Dengue virus serotype 2 and enterovirus (EV) 71 using this developed integrated system. Comparable to a large-scale apparatus, the integrated microsystem can perform mixing, incubation, purification, transportation, and nucleic acid amplification of virus, possibly making it a crucial platform for future diagnosis applications.

Magnetics↗

Development and characterization of an all-solid-state potentiometric biosensor array microfluidic device for multiple ion analysis.

A microfluidic device with an all-solid-state potentiometric biosensor array was developed using microfabrication technology. The sensor array included a pH indicator, and potassium and calcium ion-selective microelectrodes. The pH indicator was an iridium oxide thin film modified platinum microelectrode and the iridium oxide was deposited by an electrochemical method. The potassium and calcium ion-selective microelectrodes were platinum coated with silicon rubber based ion-selective membranes with respectively potassium (valinomycin) and calcium (ETH 1001) ionophores. The detection system was integrated with a micro-pneumatic pump which can continuously drive fluids into the microchannel through sensors at flow rates ranging from 52.4 microl min(-1) to 7.67 microl min(-1). The sensor array microfluidic device showed near-Nernstian responses with slopes of 62.62 mV +/- 2.5 mV pH(-1), 53.76 mV +/- 3 mV -log[K+](-1) and 25.77 mV +/- 2 mV -log[Ca2+](-1) at 25 degrees C +/- 5 degrees C, and a linear response within the pH range of 2-10, with potassium and calcium concentrations between 0.1 M and 10(-6) M. In this study the device provided a convenient way to measure the concentration of hydrogen, potassium and calcium ions, which are important physiological parameters.

Biosensing Techniques↗

Model description of contact angles in electrowetting on dielectric layers.

The electrowetting on dielectric (EWOD) technique has considerable potential for microfluidic and biomedical applications. The Lippmann-Young model based on the force balance concept has long been used to predict the contact angles of droplets under electrowetting. However, recent experimental evidence has indicated that this model fails to provide accurate predictions of the lower contact angles associated with saturation conditions at higher electric potentials. Hence, the study simulates the internal flow in an actuated droplet and treats it as stagnation-point flow. This kinetic energy is then taken into consideration while calculating the contact angles using an energy balance model. The energy of an actuated droplet is contributed by the combination of the side surface tension energy, the base tension energy, the dielectric energy, and the kinetic energy when deriving the energy balance model. Consequently, the new energy balance model modifies the Lippmann-Young equation, thereby providing enhanced reasonable predictions of the droplet contact angle across the higher electric potential where the contact angles are close to the saturated condition.

Journal Article↗

An integrated microfluidic chip for DNA/RNA amplification, electrophoresis separation and on-line optical detection.

This study presents an integrated microfluidic chip capable of performing DNA/RNA (deoxyribonucleic acid/ribonucleic acid) amplification, electrokinetic sample injection and separation, and on-line optical detection of nucleic acid products in an automatic mode. In the proposed device, DNA/RNA samples are first replicated using a micromachine-based PCR module or reverse transcription PCR (RT-PCR) module and then transported by a pneumatic micropump to a sample reservoir. The samples are subsequently driven electrokinetically into a microchannel, where they are separated electrophoretically and then detected optically by a buried optical fiber. The various modules of the integrated microfluidic chip are fabricated from cheap bio-compatible materials, such as PDMS, polymethylmethacrylate, and soda-lime glass. The functionality of the proposed device is demonstrated through its successful application to the DNA-based bacterial detection of Streptococcus pneumoniae and the RNA-based detection of Dengue-2 virus. It is shown that the low thermal inertia of the PCR/RT-PCR modules reduces the sample and reagent consumption and shortens the reaction time. With less human intervention, the subsequent DNA separation and detection could be performed in an automatic mode. The integrated microfluidic device proposed in this study represents a crucial contribution to the fields of molecular biology, genetic analysis, infectious disease detection, and other biomedical applications.

DNA↗

Integrated polymerase chain reaction chips utilizing digital microfluidics.

This study reports an integrated microfluidic chip for polymerase chain reaction (PCR) applications utilizing digital microfluidic chip (DMC) technology. Several crucial procedures including sample transportation, mixing, and DNA amplification were performed on the integrated chip using electro-wetting-on-dielectric (EWOD) effect. An innovative concept of hydrophobic/hydrophilic structure has been successfully demonstrated to integrate the DMC chip with the on-chip PCR device. Sample droplets were generated, transported and mixed by the EWOD-actuation. Then the mixture droplets were transported to a PCR chamber by utilizing the hydrophilic/hydrophobic interface to generate required surface tension gradient. A micro temperature sensor and two micro heaters inside the PCR chamber along with a controller were used to form a micro temperature control module, which could perform precise PCR thermal cycling for DNA amplification. In order to demonstrate the performance of the integrated DMC/PCR chips, a detection gene for Dengue II virus was successfully amplified and detected. The new integrated DMC/PCR chips only required an operation voltage of 12V(RMS) at a frequency of 3 KHz for digital microfluidic actuation and 9V(DC) for thermal cycling. When compared to its large-scale counterparts for DNA amplification, the developed system consumed less sample and reagent and could reduce the detection time. The developed chips successfully demonstrated the feasibility of Lab-On-a-Chip (LOC) by utilizing EWOD-based digital microfluidics.

Dengue Virus↗

Miniature RT-PCR system for diagnosis of RNA-based viruses.

This paper presents an innovative portable chip-based RT-PCR system for amplification of specific nucleic acid and detection of RNA-based viruses. The miniature RT-PCR chip is fabricated using MEMS (Micro-electro-mechanical-system) techniques, and comprises a micro temperature control module and a PDMS (polydimethylsiloxane)-based microfluidic control module. The heating and sensing elements of temperature control module are both made of platinum and are located within the reaction chambers in order to generate a rapid and uniform thermal cycling. The microfluidic control module is capable of automating testing process with minimum human intervention. In this paper, the proposed miniature RT-PCR system is used to amplify and detect two RNA-based viruses, namely dengue virus type-2 and enterovirus 71 (EV 71). The experimental data confirm the ability of the system to perform a two-step RT-PCR process. The developed miniature system provides a crucial tool for the diagnosis of RNA-based viruses.

Dengue Virus↗

Microfluidic pH-sensing chips integrated with pneumatic fluid-control devices.

This paper presents a microfluidic chip capable of performing precise continuous pH measurements in an automatic mode. The chip is fabricated using micro-electro-mechanical-systems (MEMS)-based techniques and incorporates polydimethylsiloxane (PDMS) microstructures, pH-sensing electrodes and pneumatic fluid-control devices. Through its enhanced microchannel design and use of pneumatic fluid-control devices, the microfluidic chip reduces the dead volume of the sample and increases the pumping rate. The maximum pumping rate of the developed micro-pump is 28 microL/min at an air pressure of 10 psi and a driving frequency of 10 Hz. The total sample volume consumed in each sensing operation is just 0.515 microL. As a result, the developed chip reduces the sample volume compared to conventional large-scale pH-sensing systems. The microfluidic chip employs the electrochemical sensing method to conduct precise pH level measurements. The sensing electrodes are fabricated by sputtering a layer of SiO(2)-LiO(2)-BaO-TiO(2)-La(2)O(3) (SLBTLO) onto platinum (Pt) electrodes and the pH value of the sample is evaluated by measuring the potential difference between the sensing electrodes and a reference electrode. Additionally, the integration of the microfluidic chip with a pneumatic fluid-control device facilitates automatic sample injection and a continuous sensing operation. The developed system provides a valuable tool with which to examine pH values in a wide range of biomedical and industrial applications.

Electrochemistry↗

Micromachined polymerase chain reaction system for multiple DNA amplification of upper respiratory tract infectious diseases.

This paper presents a micro polymerase chain reaction (PCR) chip for the DNA-based diagnosis of microorganism genes and the detection of their corresponding antibiotic-resistant genes. The micro PCR chip comprises cheap biocompatible soda-lime glass substrates with integrated thin-film platinum resistors as heating/sensing elements, and is fabricated using micro-electro-mechanical-system (MEMS) techniques in a reliable batch-fabrication process. The heating and temperature sensing elements are made of the same material and are located inside the reaction chamber in order to ensure a uniform temperature distribution. This study performs the detection of several genes associated with upper respiratory tract infection microorganisms, i.e. Streptococcus pneumoniae, Haemopilus influenze, Staphylococcu aureus, Streptococcus pyogenes, and Neisseria meningitides, together with their corresponding antibiotic-resistant genes. The lower thermal inertia of the proposed micro PCR chip relative to conventional bench-top PCR systems enables a more rapid detection operation with reduced sample and reagent consumption. The experimental data reveal that the high heating and cooling rates of the system (20 and 10 degrees C/s, respectively) permit successful DNA amplification within 15 min. The micro PCR chip is also capable of performing multiple DNA amplification, i.e. the simultaneous duplication of multiple genes under different conditions in separate reaction wells. Compared with the large-scale PCR system, it is greatly advantageous for fast diagnosis of multiple infectious diseases. Multiplex PCR amplification of two DNA segments in the same well is also feasible using the proposed micro device. The developed micro PCR chip provides a crucial tool for genetic analysis, molecular biology, infectious disease detection, and many other biomedical applications.

Electrophoresis↗

A microfabricated capillary electrophoresis chip with multiple buried optical fibers and microfocusing lens for multiwavelength detection.

We present a new microfluidic device utilizing multiwavelength detection for high-throughput capillary electrophoresis (CE). In general, different fluorescent dyes are only excited by light sources with appropriate wavelengths. When excited by an appropriate light source, a fluorescent dye emits specific fluorescence signals of a longer wavelength. This study designs and fabricates plastic micro-CE chips capable of performing multiple-wavelength fluorescence detection by means of multimode optic fiber pairs embedded downstream of the separation channel. For detection purposes, the fluorescence signals are enhanced by positioning microfocusing lens structures at the outlets of the excitation fibers and the inlets of the detection fibers, respectively. The proposed device is capable of detecting multiple samples labeled with different kinds of fluorescent dyes in the same channel in a single run. The experimental results demonstrate that various proteins, including bovine serum albumin and beta-casein, can be successfully injected and detected by coupling two light sources of different wavelengths to the two excitation optic fibers. Furthermore, the proposed device also provides the ability to measure the speed of the samples traveling in the microchannel. The developed multiwavelength micro-CE chip could have significant potential for the analysis of DNA and protein samples.

Electrophoresis, Capillary↗

Microautosamplers for discrete sample injection and dispensation.

Microfluidic systems show considerable potential for use in the continuous reaction and analysis of biosamples for various applications, such as drug screening and chemical synthesis. Typically, microfluidic chips are externally connected with large-scale autosamplers to inject specific volumes of discrete samples in the continuous monitoring and analysis of multiple samples. This paper presents a novel microelectromechanical system (MEMS)-based autosampler capable of performing the discrete injection and dispensation of variable-volume samples. This microdevice can be integrated with other microfluidic devices to facilitate the continuous monitoring and analysis of multiple biosamples. By means of electroosmotic focusing and switching controlled by the direct application of electric sources on specific fluid reservoirs, a precise sample volume can be injected into the specified outlet port. Fluorescence dye images verify the performance of the developed device. An injection-and-washing scheme is developed to prevent cross-contamination during the continuous injection of different samples. This approach renders feasible the injection of several discrete samples using a single microchip. Compared to its large-scale counterparts, the developed microautosampler is compact in size, has low fabrication costs, is straightforward to control, and most importantly, is readily integrated with other microfluidic devices (e.g., microcapillary electrophoresis chips) to form a microfluidic system capable of the continuous monitoring and analysis of bioreactions. The proposed microautosampler could be promising towards realizing the micrototal analysis system (mu-TAS) concept.

Electrophoresis, Microchip↗

On the surface modification of microchannels for microcapillary electrophoresis chips.

This paper presents systematic investigation of the microchannel surface properties in microCE chips. Three popular materials for microCE chips, polydimethylsiloxane (PDMS), quartz, and glass, are used. The zeta potentials of these microchannels are calculated by measuring the EOF velocity to evaluate the surface properties after surface modification. The hydrophobic PDMS is usually plasma-treated for microCE applications. In this study, a new method using a high-throughput atmospheric plasma generator is adopted to treat the PDMS surface under atmospheric conditions. In this approach, the cost and time for surface treatment can be significantly reduced compared with the conventional vacuum plasma generator method. Experimental results indicate that new functional groups could be formed on the PDMS surface after treatment, resulting in a change in the surface property. The time-dependent surface property of the plasma-treated PDMS is then measured in terms of the zeta potential. Results show that the surface property will reach a stable condition after 1 h of plasma treatment. For glass CE chips, two new methods for changing the microchannel surface properties are developed. Instead of using complicated and time-consuming chemical silanization procedures for CE channel surface modification, two simple and reliable methods utilizing organic-based spin-on-glass and water-soluble acrylic resin are reported. The proposed method provides a fast batch process for controlling the surface properties of glass-based CE channels. The proposed methods are evaluated using PhiX-174 DNA maker separation. The experimental data show that the surface property is modified and separation efficiency greatly improved. In addition, the long-term stability of both coatings is verified in this study. The methods proposed in this study show potential as an excellent solution for glass-based microCE chip surface modification.

Bacteriophage phi X 174↗

Active mixing inside microchannels utilizing dynamic variation of gradient zeta potentials.

This study presents a new active micromixer with high mixing efficiency achieved by means of a gradient distribution of the surface zeta potential controlled by changing the frequency of voltage applied on shielding electrodes. Gradient surface zeta potential is generated by applying a high voltage to inclined buried shielding electrodes. While alternating the frequency of driving voltage, the zeta potential could be changed accordingly, thus providing a significant mixing effect inside microchannels. A theoretical model is proposed to predict the distribution of zeta potential. The results from this model are critically compared with the well-developed three-capacitor model. Additionally, two time-factor scales, the charge time of capacitor and mixing length flow time, are used to predict the optimum frequency. The prediction of optimum frequency, 0.5 Hz, is consistent with experimental results. Moreover, a five-pair inclined shielding electrode with a frequency of 0.5 Hz leads to a significant improvement in the mixing performance of the active micromixer. Numerical results indicate that a localized flow circulation is generated when the control voltage is applied to the inclined shielding electrodes. Furthermore, the streamlines are experimentally observed by using fluorescent beads. The shape of this circulation is dependent on the distribution of gradient zeta potential, which is determined by the arrangement of electrodes. The effects of the number of electrode pairs and the layout of shielding electrodes on the mixing performance of micromixer are also explored both numerically and experimentally. It is revealed that five-pair inclined electrodes at 0.5 Hz provide the highest mixing efficiency. Finally, a reaction between N-benzoyl-L-arginine-p-nitroanilide and trypsin enzyme is performed to verify the capability of micromixers. The experimental results reveal that the reaction can achieve a higher performance indicating a higher mixing efficiency. The active micromixers could be used in microfluidic systems for improving the mixing efficiency and thus enhancing the bioreaction.

Electrophoresis, Microchip↗

Automatic bio-sampling chips integrated with micro-pumps and micro-valves for disease detection.

The present study reports a microfluidic system using the concept of membrane-movement to design and fabricate micro-pneumatic valves and pumps to form a bio-sensing diagnostic chip. The automatic bio-sampling system includes a micro-diagnostic chip fabricated by using MEMS (micro-electro-mechanical systems) technology and an automatic platform comprising of a control circuit, a compressed air source and several electromagnetic valve switches. The control circuit is used to regulate the electromagnetic valve switches, causing thin PDMS membranes to deflect pneumatically by the compressed air and generate valving and pumping effects. The micro-diagnostic chip allows for the quick detection of diseases. Compared to large-scale systems, the new microfluidic system uses smaller amounts of samples and reagents and performs fast diagnosis in an automated format. Instead of using traditional pneumatic micro-pumps, the current study adopts a new design called "spider-web" micro-pumps to increase the pumping rate, and more importantly, improve the uniformity of flow rates inside multiple micro-channels. Experimental data show that for disease diagnosis, the bio-sensing chips integrated with the micro-pneumatic valves and the peristaltic micro-pumps could successfully perform diagnosis tests. Small amounts of samples and reagents could be injected into the diagnosis chips using the micro-pumps and the micro-pneumatic valves could effectively control the movement of the samples and reagents. In order to demonstrate the functionality of the developed device, detection of hepatitis C virus (HCV) and syphilis has been performed using the bio-sampling chips. Experimental data show that fluorescence signals from the microfluidic system were comparable to the ones using conventional testing methods. The developed chip could be easily extended for multiple disease detection. The automatic bio-sensing chips could provide a useful tool for fast disease detection and be crucial for a micro-total-analysis system.

Biosensing Techniques↗

Integrated optical-fiber capillary electrophoresis microchips with novel spin-on-glass surface modification.

This paper presents a novel micro-capillary electrophoresis (CE) chip with embedded optical fibers for the on-line detection of DNA samples. The optical fibers are pre-etched and then inserted directly into fiber channels incorporated within low-cost soda-lime glass substrates. The embedded optical fibers are precisely aligned with the microfluidic channels such that the induced fluorescence signals from labeled bio-samples can be detected. This arrangement avoids the requirement for delicate optical alignment procedures and equipment. Surface modification of the CE channels is accomplished by means of a simple and reliable organic-based spin-on-glass (SOG) method. The zeta potential distribution and the corresponding electroosmotic mobility of the fluid are simulated numerically for the modified and non-modified channel surfaces, and then both sets of results are verified experimentally. The present results indicate that the value of the zeta potential for a surface with an SOG coating is 19.3 times smaller than that of an untreated surface. A phiX-174 DNA marker fluid is used to evaluate the injection and separation performance of the developed micro-CE device. Furthermore, the long-term stability of the SOG-coated surface is also investigated. The experimental data reveal that the microchip device is capable of providing highly efficient separations of bio-molecules, and that the SOG layer retains its low zeta potential characteristics for at least 45 days. The present results confirm the effectiveness of the proposed micro-CE chip in performing the on-line detection of DNA samples, and indicate that the SOG process represents a simple and reliable solution for the surface modification of glass-based microchannels.

Bacteriophages↗

Dispersion control in microfluidic chips by localized zeta potential variation using the field effect.

A new technique to minimize the effects of turn-induced dispersion within U-shaped separation channels by using the field effect within a capacitor to vary the zeta potential along the channel walls in the vicinity of the microchannel is described. The effects of the separation channel geometry, the fluid velocity profile, and the use of the field effect to control the zeta potential on the band distribution in the detection area are extensively discussed. The results for a U-shaped separation channel indicate that varying the zeta potential by controlling the field effect significantly reduces the band dispersion induced by the 90 degrees turns within the channel. Finally, it is shown that the application of the proposed localized zeta potential variation method also results in a correction of the band tilting phenomenon and a reduction in the racetrack effect.

Electromagnetic Fields↗

Electrokinetic focusing injection methods on microfluidic devices.

This paper presents an experimental and numerical investigation into electrokinetic focusing injection on microfluidic chips. The valving characteristics on microfluidic devices are controlled through appropriate manipulations of the electric potential strengths during the sample loading and dispensing steps. The present study also addresses the design and testing of various injection systems used to deliver a sample plug. A novel double-cross injection microfluidic chip is fabricated, which employs electrokinetic focusing to deliver sample plugs of variable volume. The proposed design combines several functions of traditional sample plug injection systems on a single microfluidic chip. The injection technique uses an unique sequence of loading steps with different electric potential distributions and magnitudes within the various channels to effectuate a virtual valve.

Journal Article↗

Multiple injection techniques for microfluidic sample handling.

This paper presents an experimental and numerical investigation into electrokinetic focusing flow injection for bioanalytical applications on 1 x N (i.e., 1 sample inlet port and N outlet ports) and M x N (i.e., M sample inlet ports and N outlet ports) microfluidic chips. A novel device is presented which integrates two important microfluidic phenomena, namely electrokinetic focusing and valveless flow switching within multiported microchannels. The study proposes a voltage control model which achieves electrokinetic focusing in a prefocusing sample injection system and which allows the volume of the sample to be controlled. Using the developed methods, the study shows how the sample may be prefocused electrokinetically into a narrow stream prior to being injected continuously into specified outlet ports. The microfluidic chips presented within this paper possess an exciting potential for use in a variety of techniques, including high-throughput chemical analysis, cell fusion, fraction collection, fast sample mixing, and many other applications within the micrototalanalysis systems field.

Automation↗