Search PubMed⌕ Search

Biomedical subjects

Guy Cloutier

Publications and source records attributed to Guy Cloutier.

23 records · Page 2Linked to original sources

Non-Gaussian statistics and temporal variations of the ultrasound signal backscattered by blood at frequencies between 10 and 58 MHz.

Very little is known about the blood backscattering behavior and signal statistics following flow stoppage at frequencies higher than 10 MHz. Measurements of the radio frequency (rf) signals backscattered by normal human blood (hematocrit = 40%, temperature = 37 degrees C) were performed in a tube flow model at mean frequencies varying between 10 and 58 MHz. The range of increase of the backscattered power during red blood cell (RBC) rouleau formation was close to 15 dB at 10 and 36 MHz, and dropped, for the same blood samples, below 8 dB at 58 MHz. Increasing the frequency from 10 to 58 MHz raised the slope of the power changes at the beginning of the kinetics of aggregation, and could emphasize the non-Gaussian behavior of the rf signals interpreted in terms of the K and Nakagami statistical models. At 36 and 58 MHz, significant increases of the kurtosis coefficient, and significant reductions of the Nakagami parameter were noted during the first 30 s of flow stoppage. In conclusion, increasing the transducer frequency reduced the magnitude of the backscattered power changes attributed to the phenomenon of RBC aggregation, but improved the detection of rapid growth in aggregate sizes and non-Gaussian statistical behavior.

Acoustics↗

Adapting the Lagrangian speckle model estimator for endovascular elastography: theory and validation with simulated radio-frequency data.

Intravascular ultrasound (IVUS) is known to be the reference tool for preoperative vessel lesion assessments and for endovascular therapy planning. Nevertheless, IVUS echograms only provide subjective information about vessel wall lesions. Since changes in the vascular tissue stiffness are characteristic of vessel pathologies, catheter-based endovascular ultrasound elastography (EVE) has been proposed in the literature as a method for outlining the elastic properties of vessel walls. In this paper, the Lagrangian Speckle Model Estimator (LSME) is formulated for investigations in EVE, i.e., using a polar coordinate system. The method was implemented through an adapted version of the Levenberg-Marquardt minimization algorithm, using the optical flow equations to compute the Jacobbian matrix. The theoretical framework was validated with simulated ultrasound rf data of mechanically complex vessel wall pathologies. The results, corroborated with Ansys finite element software, demonstrated the potential of EVE to provide useful information about the heterogeneous nature of atherosclerotic plaques.

Animals↗

A new clutter rejection algorithm for Doppler ultrasound.

Several strategies, known as clutter or wall Doppler filtering, were proposed to remove the strong echoes produced by stationary or slow moving tissue structures from the Doppler blood flow signal. In this study, the matching pursuit (MP) method is proposed to remove clutter components. The MP method decomposes the Doppler signal into wavelet atoms that are selected in a decreasing energy order. Thus, the high-energy clutter components are extracted first. In the present study, the pulsatile Doppler signal s(n) was simulated by a sum of random-phase sinusoids. Two types of high-amplitude clutter signals were then superimposed on s(n): time-varying low-frequency components, covering systole and early diastole, and short transient clutter signals, distributed within the whole cardiac cycle. The Doppler signals were modeled with the MP method and the most dominant atoms were subtracted from the time-domain signal s(n) until the signal-to-clutter (S/C) ratio reached a maximum. For the low-frequency clutter signal, the improvement in S/C ratio was 19.0 +/- 0.6 dB, and 72.0 +/- 4.5 atoms were required to reach this performance. For the transient clutter signal, ten atoms were required and the maximum improvement in S/C ratio was 5.5 +/- 0.5 dB. The performance of the MP method was also tested on real data recorded over the common carotid artery of a normal subject. Removing 15 atoms significantly improved the appearance of the Doppler sonogram contaminated with low-frequency clutter. Many more atoms (over 200) were required to remove transient clutter components. These results suggest the possibility of using this signal processing approach to implement clutter rejection filters on ultrasound commercial instruments.

Algorithms↗

Modeling the frequency dependence (5-120 MHz) of ultrasound backscattering by red cell aggregates in shear flow at a normal hematocrit.

The frequency dependence of the ultrasound signal backscattered by blood in shear flow was studied using a simulation model. The ultrasound backscattered signal was computed with a linear model that considers the characteristics of the ultrasound system and tissue acoustic properties. The tissue scattering properties were related to the position and shape of the red blood cells (RBCs). A 2D microrheological model simulated the RBC dynamics in a Couette shear flow system. This iterative model, described earlier [Biophys. J. 82, 1696-1710 (2002)], integrates the hydrodynamic effect of the flow, as well as adhesive and repulsive forces between RBCs. RBC aggregation was simulated at 40% hematocrit and shear rates of 0.05-2 s(-1). The RBC aggregate sizes ranged, on average, from 3.3 RBCs at 2 s(-1) to 33.5 cells at 0.05 s(-1). The ultrasound backscattered power was studied at frequencies between 5-120 MHz and insonification angles between 0-180 degrees. At frequencies below approximately 30 MHz, the ultrasound backscattered power increased as the shear rate was decreased and the size of the aggregates was raised. A totally different scattering behavior was noted above 30 MHz. Typical spectral slopes of the backscattered power (log-log scale) between 5-25 MHz equaled 3.8, whereas slopes down to 0.6 were measured at 0.05 s(-1), between 40-60 MHz. The ultrasound backscattered power was shown to be angle dependent at low frequencies (5-25 MHz). The anisotropy persisted at high frequencies (>25 MHz) for small aggregates (at 2 s(-1)). In conclusion, this study sheds some light on the blood backscattering behavior with an emphasis on the non-Rayleigh regime. Additional experimental studies may be necessary to validate the simulation results, and to fully understand the relation between the ultrasound backscattered power, level of RBC aggregation, shear rate, frequency, and insonification angle.

Acoustics↗

Simulation of ultrasound backscattering by red cell aggregates: effect of shear rate and anisotropy.

Tissue characterization using ultrasound (US) scattering allows extraction of relevant cellular biophysical information noninvasively. Characterization of the level of red blood cell (RBC) aggregation is one of the proposed application. In the current paper, it is hypothesized that the microstructure of the RBCs is a main determinant of the US backscattered power. A simulation model was developed to study the effect of various RBC configurations on the backscattered power. It is an iterative dynamical model that considers the effect of the adhesive and repulsive forces between RBCs, and the effect of the flow. The method is shown to be efficient to model polydispersity in size, shape, and orientation of the aggregates due to the flow, and to relate these variations to the US backscattering properties. Three levels of aggregability at shear rates varying between 0.05 and 10 s(-1) were modeled at 40% hematocrit. The simulated backscattered power increased with a decrease in the shear rate or an increase in the RBC aggregability. Angular dependence of the backscattered power was observed. It is the first attempt to model the US power backscattered by RBC aggregates polydisperse in size and shape due to the shearing of the flow.

Animals↗