Search PubMed⌕ Search

Biomedical subjects

Guoyan Zheng

Publications and source records attributed to Guoyan Zheng.

11 recordsLinked to original sources

Zero-dose fluoroscopy-based close reduction and osteosynthesis of diaphyseal fracture of femurs.

This paper presents a novel technique to create a computerized fluoroscopy with zero-dose image updates for computer-assisted fluoroscopy-based close reduction and osteosynthesis of diaphyseal fracture of femurs. With the novel technique, repositioning of bone fragments during close fracture reduction will lead to image updates in each acquired imaging plane, which is equivalent to using several fluoroscopes simultaneously from different directions but without any X-ray radiation. Its application facilitates the whole fracture reduction and osteosynthesis procedure when combining with the existing leg length and antetorsion restoration methods and may result in great reduction of the X-ray radiation to the patient and to the surgical team. In this paper, we present the approach for achieving such a technique and the experimental results with plastic bones.

Algorithms↗

Navigated intraoperative analysis of lower limb alignment.

INTRODUCTION: Accurate intraoperative assessment of lower limb alignment is crucial for the treatment of long bone fractures, implantation of knee arthroplasties and correction of deformities. During orthopaedic surgery, exact real time control of the mechanical axis is strongly desirable. The aim of this study was to compare conventional intraoperative analysis of the mechanical axis by the cable method with continuous, 3-dimensional imaging with a navigation system. MATERIALS AND METHODS: Twenty legs of fresh human cadaver were randomly assigned to conventional analysis with the cable method (n = 10) or navigated analysis with a fluoroscopy based navigation system (n = 10). The intersection of the mechanical axis with the tibia plateau was presented as percentage of the tibia plateau (beginning with 0% at the medial border and ending with 100% laterally). CT-scans were performed for all legs and the CT-values of the mechanical axis were compared to the measurements after cable method and navigation. Furthermore, the radiation time and dose area product of both groups for single analysis of the mechanical axis was compared. RESULTS: Conventional evaluation of the mechanical axis by the cable method showed 6.0+/-3.1% difference compared to the analysis by CT. In the navigated group the difference was 2.6+/-1.8% (P = 0.008). Radiation time and dose area product were highly significantly lower after conventional measurement. CONCLUSIONS: Navigated intraoperative evaluation of the mechanical axis offers increased accuracy compared to conventional intraoperative analysis. Furthermore, navigation provides continuous control not only of the mechanical axis, but also of the sagittal and transverse plane. Using the cable method, radiation exposure depends on the number of measurements and is lower compared to the navigation system for single intraoperative analysis of the mechanical axis, but may be higher in case of repeated intraoperative measurements.

Arthroplasty, Replacement, Knee↗

Implementation, accuracy evaluation, and preliminary clinical trial of a CT-free navigation system for high tibial opening wedge osteotomy.

OBJECTIVE: The objectives of this study are to design and evaluate a CT-free intra-operative planning and navigation system for high tibial opening wedge osteotomy. This is a widely accepted treatment for medial compartment osteoarthritis and other lower extremity deformities, particularly in young and active patients for whom total knee replacement is not advised. However, it is a technically demanding procedure. Conventional preoperative planning and surgical techniques have so far been inaccurate, and often resulting in postoperative malalignment representing either under- or over-correction, which is the main reason for poor long-term results. In addition, conventional techniques have the potential to damage the lateral hinge cortex and tibial neurovascular structures, which may cause fixation failure, loss of correction, or peroneal nerve paralysis. All these common problems can be addressed by the use of a surgical navigation system. MATERIALS AND METHODS: Surgical instruments are tracked optically with the SurgiGATE((R)) navigation system (PRAXIM MediVision, La Tronche, France). Following exposure, dynamical reference bases are attached to the femur, tibia, and proximal fragment of the tibia. A patient-specific coordinate system is then established, on the basis of registered anatomical landmarks. After intra-operative deformity measurement and correction planning, the osteotomy is performed under navigational guidance. The deformities are corrected by realigning the mechanical axis of the affected limb from the diseased medial compartment to the healthy lateral side. The wedge size, joint line orientation, and tibial plateau slope are monitored during correction. Besides correcting uni-planar varus deformities, the system provides the functionality to correct complex multi-planar deformities with a single cut. Furthermore, with on-the-fly visualization of surgical instruments on multiple fluoroscopic images, penetration of the hinge cortex and damage to the neurovascular structures due to an inappropriate osteotomy can be avoided. RESULTS: The laboratory evaluation with a plastic bone model (Synbone AG, Davos, Switzerland) shows that the error of deformity correction is <1.7 degrees (95% confidence interval) in the frontal plane and <2.3 degrees (95% confidence interval) in the sagittal plane. The preliminary clinical trial confirms these results. CONCLUSION: A novel CT-free navigation system for high tibial osteotomy has been developed and evaluated, which holds the promise of improved accuracy, reliability, and safety of this procedure.

Arthroscopy↗

Computer-assisted LISS plate osteosynthesis of proximal tibia fractures: feasibility study and first clinical results.

Fluoroscopy is the most common tool for the intraoperative control of long-bone fracture reduction. Limitations of this technology include high radiation exposure for the patient and the surgical team, limited visual field, distorted images, and cumbersome verification of image updating. Fluoroscopy-based navigation systems partially address these limitations by allowing fluoroscopic images to be used for real-time surgical localization and instrument tracking. Existing fluoroscopy-based navigation systems are still limited as far as the virtual representation of true surgical reality is concerned. This article, for the first time, presents a reality-enhanced virtual fluoroscopy with radiation-free updates of in situ surgical fluoroscopic images to control metaphyseal fracture reduction. A virtual fluoroscopy is created using the projection properties of the fluoroscope; it allows the display of detailed three-dimensional (3D) geometric models of surgical tools and implants superimposed on the X-ray images. Starting from multiple registered fluoroscopy images, a virtual 3D cylinder model for each principal bone fragment is constructed. This spatial cylinder model not only supplies a 3D image of the fracture, but also allows effective fragment projection recovery from the fluoroscopic images and enables radiation-free updates of in situ surgical fluoroscopic images by non-linear interpolation and warping algorithms. Initial clinical experience was gained during four tibia fracture fixations that were treated by LISS (Less Invasive Stabilization System) osteosynthesis. In the cases operated on, after primary image acquisition, the image intensifier was replaced by the virtual reality system. In all cases, the procedure including fracture reduction and LISS osteosynthesis was performed entirely in virtual reality. A significant disadvantage was the unfamiliar operation of this prototype software and the need for an additional operator for the navigation system.

Adult↗

A fluoroscopy-based surgical navigation system for high tibial osteotomy.

High tibial osteotomy is a widely accepted treatment for unicompartmental osteoarthritis of the knee and other lower extremity deformities, particularly in young and active patients. However, it is generally recognized as a technically demanding procedure. The lack of intraoperative control of the mechanical axis of the affected limb often results in postoperative malalignments, which is one of the main reasons for poor long-term results. Moreover, inaccurate osteotomies, such as insufficient or excessive bone cut, or incorrect orientation of the chisel or saw blade, have been observed. A computer assisted intraoperative planning and navigation system is therefore proposed in order to address these technical problems. During operation, fluoroscopic images are acquired and anatomical landmarks are digitized; a patient-specific coordinate system is established accordingly. After the three-dimensional measurement of the deformity and interactive planning of the osteotomy plane, the deformity is corrected under navigational guidance. The proposed system has been successfully introduced into the clinical practice of surgery after encouraging laboratory evaluations, with results affirming that it is safe and accurate.

Fluoroscopy↗

Computer aided high tibial open wedge osteotomy.

High tibial osteotomy is a widely accepted treatment of medial compartment osteoarthritis as well as other lower extremity deformities. However, it is a technically demanding procedure. The lack of exact intraoperative real time control of the mechanical axis often results in postoperative malalignments, which is one reason for poor long term results. These problems can be addressed with the use of a surgical navigation system. Following exposure, dynamic reference bases (DRBs) are attached to the femur, and the proximal and the distal part of the tibia. After intraoperative measurement of the deformities and correction planning, the osteotomy is performed under navigational guidance. The wedge size, joint line orientation, and tibial plateau slope are monitored during correction. The in vitro evaluation with a plastic bone model suggests that the error of deformity correction is less than 1.7 degrees (95% confidence limits) in the frontal, and less than 2.3 degrees (95% confidence limits) in the sagittal plane, respectively. On a cadaver study of 13 legs, the mechanical axis intersected the Fujisawa line in 80.7% (range 77.5-85.8%). The preliminary clinical experience confirms these results. A novel computer tomography free navigation system for high tibial osteotomy has been developed that holds the promise of improving the accuracy, reliability, and safety of this kind of approach.

Adult↗

C-arm based navigation in total hip arthroplasty-background and clinical experience.

After experimental and preclinical evaluation of a CT-free image guided surgical navigation system for acetabular cup placement, the system was introduced into clinical routine. The computation of the angular orientation of the cup is based on reference coordinates from the anterior pelvic plane concept. A hybrid strategy for pelvic landmark acquisition has been introduced, involving percutaneous pointer-based digitization with the noninvasive bi-planar landmark reconstruction using multiple registered fluoroscopy images. From January 2001 to October 2003, a total of 236 consecutive patients (mean age 66 years, 144 male, 92 female, 124 left and 112 right hip joints) were operated on with the hybrid CT-free navigation system. During each operation, the angular orientation of the inserted implant was recorded. To determine the placement accuracy of the acetabular components, the first 50 consecutive patients underwent a CT scan 7-10 days postoperatively to analyze the cup position relative to the anterior pelvic plane. This procedure was done blinded and with commercial planning software. There was no significant learning curve observed for the use of the system. Mean values for postoperative inclination read 42 degrees (SD 3.6, range (37-49)) and anteversion 21 degrees (SD 3.9, range (10-28)). The resulting system accuracy, ie, the difference between intraoperatively calculated cup orientation and postoperatively measured implant position shows a maximum error of 5 degrees for the inclination (mean 1.5 degrees, SD 1.1) and 6 degrees for the anteversion (mean 2.4 degrees, SD 1.3). An accuracy of better than 5 degrees inclination and 6 degrees anteversion was achieved under clinical conditions, which implies that there is no significant difference in performance from the established CT-based navigation methods. Image-guided CT-free cup navigation provides a reliable solution for future total hip arthroplasty (THA).

Aged↗

Computer aided reduction and imaging.

Reduction is one of the key procedures in orthopedic trauma surgery and has been acknowledged as one of the conditions for a good outcome in intraarticular and extra-articular fractures. The information available to the surgeon during the reduction maneuver can be divided into visual and tactile information. The optimal implementation of these parameters, combined with the surgeon's individual experience, will significantly affect the results of the operation. Anatomical regions where a limited direct view through the approach is supported by intraoperative imaging are intra-articular fractures of the elbow, forearm, acetabulum, proximal tibia, pilon, and hindfoot, and extra-articular fractures of the spine, pelvis, femur, and tibial shaft. Surgery in these regions is demanding since the approaches limit the visual control of the axes and also the anatomical reduction within the joint. Computer aided orthopedic surgery (CAOS) was introduced to increase the accuracy of selected procedures in orthopedic surgery. One of the most frequently applied applications is pedicle screw insertion in posterior spinal surgery. The current working group has identified computer aided reduction and implant positioning as an unresolved area of CAOS that would be highly relevant to the operative treatment of fractures. The development of tools for computer aided reduction is of major importance and is much desired by the orthopedic community. Such a reduction tool would be a significant step forward in the development of orthopedic trauma care. It would facilitate new procedures and new operations and also help to attain a completely new level with regard to what we can achieve in terms of minimal invasiveness and increased precision. The synergies of the expert group are deployed to develop the required software modules and hardware. Other areas of computer aided orthopedic surgery will certainly benefit from the integration of this technology as well.

Bone Screws↗

Image-based hip navigation.

After experimental and preclinical evaluation (HAP Paul Award 2001) of a CT-free image-guided surgical navigation system for acetabular cup placement, the system was introduced into clinical routine. The computation of the angular orientation of the cup is based on reference coordinates from the anterior pelvic plane (APP) concept. A hybrid strategy for pelvic landmark acquisition has been introduced involving percutaneous pointer-based digitization with the noninvasive biplanar landmark reconstruction using multiple registered fluoroscopy images. From January 2001 to May 2002, 118 consecutive patients (mean age 68 years, 82 male, 36 female, and 62 left and 56 right hip joints) were operated on with the hybrid CT-free navigation system. During each operation, the angular orientation of the inserted implant was recorded. To determine the placement accuracy of the acetabular components, the first 50 consecutive patients underwent a CT scan 7-10 days postoperatively to analyze the cup position relative to the APP. This was done blinded with commercial planning software. There was no significant learning curve observed for the use of the system. Mean values for postoperative inclination read 43 degrees (SD 3.0, range 37-49) and anteversion 19 degrees (SD 3.9, range 10-28). The resulting system accuracy, i.e., the difference between intraoperatively calculated cup orientation and postoperatively measured implant position, shows a maximum error of 5 degrees for the inclination (mean 1.5 degrees, SD 1.1) and 6 degrees for the anteversion (mean 2.4 degrees, SD 1.3). An accuracy of better than 5 degrees inclination and 6 degrees anteversion was achieved under clinical conditions, which implies that there is no significant difference in performance from the established CT-based navigation methods. Image-guided CT-free cup navigation provides a reliable solution for future total hip arthroplasty (THA).

Acetabulum↗

A hybrid CT-free navigation system for total hip arthroplasty.

OBJECTIVE: To design and evaluate a novel CT-free image-guided surgical navigation system for assisting placement of both acetabular and femoral components in total hip arthroplasty (THA). MATERIALS AND METHODS: The methodology in this paper is conceptually based on our previous work on CT-free cup placement. For femoral component placement, two patient-specific reference coordinate systems are first defined: One for the pelvis, based on the so-called anterior pelvic plane (APP) concept, and one for the femur, using the center of the femoral head, the posterior condylar tangential line, and the medullary canal axis of the proximal femur. A hybrid method is used for the associated landmark acquisition, which involves percutaneous point-based digitization and bi-planar landmark reconstruction using multiple registered fluoroscopy images. The following clinical parameters are computed in real time: cup inclination and anteversion, antetorsion and varus/valgus of the stem, lateralization, and change in leg length for complete THA. In addition, instrument actions such as reaming, impaction, and rasping are visualized for the surgeon by superimposing virtual instrument representations onto the fluoroscopic images. RESULTS: A laboratory study of computer-assisted measurement of antetorsion and varus/valgus, change in leg length, and lateralization for femoral stem placement demonstrated the high precision of the proposed navigation system. Compared with CT-based measurement, mean deviations of 1.0 degrees, 0.6 degrees, 0.7 mm, and 1.7 mm were found for antetorsion, varus/valgus, change in leg length, and lateralization, respectively, with standard deviations of 0.5 degrees, 0.5 degrees, 0.6 mm, and 0.7 mm, respectively. A pilot clinical evaluation showed that THA could benefit from this newly developed CT-free hybrid system. CONCLUSIONS: The proposed CT-free hybrid system promises to increase the accuracy and reliability of THA surgery.

Aged↗

Endoscope-based hybrid navigation system for minimally invasive ventral spine surgeries.

The availability of high-resolution, magnified, and relatively noise-free endoscopic images in a small workspace, 4-10 cm from the endoscope tip, opens up the possibility of using the endoscope as a tracking tool. We are developing a hybrid navigation system in which image-analysis-based 2D-3D tracking is combined with optoelectronic tracking (Optotrak) for computer-assisted navigation in laparoscopic ventral spine surgeries. Initial results are encouraging and confirm the ability of the endoscope to serve as a tracking tool in surgical navigation where sub-millimetric accuracy is mandatory.

Endoscopes↗