Search PubMed⌕ Search

Biomedical subjects

Guoli Shen

Publications and source records attributed to Guoli Shen.

5 recordsLinked to original sources

A novel biosensing interfacial design produced by assembling nano-Au particles on amine-terminated plasma-polymerized films.

A novel biosensing interfacial design strategy has, for the first time, been produced by assembling nano-Au particles on amine-terminated plasma-polymerized films (PPF). A quartz-crystal microbalance (QCM) as a model transducer was deposited with PPF of n-butylamine by use of a glow discharge and then treated with nano-Au particles. The kinetic assembly process and conditions were studied using the real-time-output device and the surface topology of the resulting crystal was characterized by atomic force microscopy (AFM) imaging. Based on analysis of the experimental data, including the association constant of Au-amine interaction, the assembly mechanism is considered to be partly or even mainly chemical adsorption. Moreover, immobilization of anti-human IgM antibody (IgM Ab), as an example, on the developed PPF-Au interface was investigated. It was found that antibody molecules immobilized by the proposed procedure had higher immunological activity than those immobilized by the conventional glutaraldehyde (GLU) cross-linking procedure or the direct gold-attachment procedure. The newly developed sensor had a better response, with a detection limit of IgM concentration as low as approximately 1.00 microg mL(-1). In particular, the extremely high stability of both PPF and nano-Au monolayer formulated allows the designed biosensing interface to withstand harsh regeneration treatment, making it reusable.

Biosensing Techniques↗

A chaotic approach to maintain the population diversity of genetic algorithm in network training.

The concept of chaos being radically different from statistical randomness is introduced into chemometrics research. The chaotic system that is deterministic with underlying patterns and inherent ability in searching the space of interest has been employed to improve the performance of chemometric algorithms. In this paper, a chaotic mutation is introduced into the genetic algorithm (GA) which is used for artificial neural network (ANN) training. The chaotic algorithm is very efficient in maintaining the population diversity during the evolution process of GA. The proposed algorithm CGANN has been testified by prediction of vibrational frequencies of octahedral hexahalides from some selected molecular parameters.

Algorithms↗

Genetic training of network using chaos concept: application to QSAR studies of vibration modes of tetrahedral halides.

The chaotic dynamical system is introduced in genetic algorithm to train ANN to formulate the CGANN algorithm. Logistic mapping as one of the most important chaotic dynamic mappings provides each new generation a high chance to hold GA's population diversity. This enhances the ability to overcome overfitting in training an ANN. The proposed CGANN has been used for QSAR studies to predict the tetrahedral modes (nu(1)(A1) and nu(2)(E)) of halides [MX(4)](epsilon). The frequencies predicted by QSAR were compared with those calculated by quantum chemistry methods including PM3, AM1, and MNDO/d. The possibility of improving the predictive ability of QSAR by including quantum chemistry parameters as feature variables has been investigated using tetrahedral tetrahalide examples.

Algorithms↗

A piezoelectric immunoassay based on self-assembled monolayers of cystamine and polystyrene sulfonate for determination of Schistosoma japonicum antibodies.

A piezoelectric immunosensor based on an improved immobilization strategy combining self-assembled monolayers (SAM) of cystamine (Cys) and polystyrene sulfonate (PSS) has been developed for the determination of Schistosoma japonicum antibodies (SjAb) in rabbit serum. Cys SAM were first applied to the gold electrode surface of the crystal, serving as a positively-charged base. Schistosoma japonicum antigen (SjAg) was then electrostatically immobilized on the crystal by means of a negatively-charged PSS layer. When sealed by use of an appropriately selected blocking reagent for BSA and normal rabbit serum (NRS), non-specific adsorption could be substantially reduced. The immunosensor was used to determine SjAb in optimized buffer medium with addition of poly(ethylene glycol) (PEG), which served as an immunoreaction enhancer. It was shown experimentally that SjAg immobilized by the Cys-PSS adsorption procedure had higher immunological activity or binding efficiency than those immobilized by the glutaraldehyde (GLU) binding or direct attachment procedures. The immunosensor developed had satisfactory sensitivity and detection limit, and regeneration of the piezoelectric quartz-crystal was easy. Analytical results obtained with infected rabbit serum samples indicated that the proposed immunosensor is a promising alternative for qualitative and quantitative determination of SjAb in clinical diagnosis of infection with Schistosoma japonicum.

Adsorption↗

Renewable urea sensor based on a self-assembled polyelectrolyte layer.

A renewable urea sensor based on a carboxylic poly(vinyl chloride) (PVC-COOH) matrix pH-sensitive membrane has been proposed, in which a positively charged polyelectrolyte layer is first constructed by using a self-assembly technique on the surface of a PVC-COOH membrane, and urease, with negative charges, is then immobilized through electrostatic adsorption onto the PVC-COOH membrane, by controlling the pH of the urease solution below its isoelectric point. The response characteristics of the PVC-COOH pH-sensitive membrane and the effects of experimental conditions have been investigated in detail. Compared with conventional covalent immobilization, the urea sensor made with this self-assembly immobilization shows significant advantage in terms of sensitivity and ease of regeneration. The potential responses of the urea sensor with self-assembly immobilization increase with the urea concentration over the concentration range 10(-5) - 10(-1) mol l(-1), and the detection limit is 0.028 mmol(-1). Moreover, this type of urea sensor can be repeatedly regenerated by using a simple washing treatment with 0.01 mol l(-1) NaOH (containing 0.5 mol l(-1) NaCl) and 0.01 mol l(-1) HCl. The urease layers and the polyelectrolyte layers on the PVC-COOH membrane are removed, the potential response of the sensor to urea solutions of different concentrations returns nearly to zero, and another assembly cycle of urease and polyelectrolyte can then be carried out.

Biosensing Techniques↗