Search PubMed⌕ Search

Biomedical subjects

Gunther Seckmeyer

Publications and source records attributed to Gunther Seckmeyer.

3 recordsLinked to original sources

Portable device for characterizing the angular response of UV spectroradiometers.

This paper introduces a device that was developed to measure the angular response of UV spectroradiometers in the field. This device is designed to be used at the operating position of spectroradiometers; thus the derived angular response also includes any effects from imperfect leveling of the diffuser and corresponds to the actual operational angular response. The design and characterization of the device and the results from its application on 11 different spectroradiometers that operate at different European UV stations are presented. Various sources of uncertainties that were identified result in a combined uncertainty in determining the angular response, which ranges between approximately 1.5% and 10%, depending on the incidence angle and the characteristics of the diffuser. For the 11 instruments, the error in reporting the diffuse irradiance ranges between 2% and - 13%, assuming isotropic distribution of the downwelling radiances.

Journal Article↗

Traveling reference spectroradiometer for routine quality assurance of spectral solar ultraviolet irradiance measurements.

A transportable reference spectroradiometer for measuring spectral solar ultraviolet irradiance has been developed and validated. The expanded uncertainty of solar irradiance measurements with this reference spectroradiometer, based on the described methodology, is 8.8% to 4.6%, depending on the wavelength and the solar zenith angle. The accuracy of the spectroradiometer was validated by repeated site visits to two European UV monitoring sites as well as by regular comparisons with the reference spectroradiometer of the European Reference Centre for UV radiation measurements in Ispra, Italy. The spectral solar irradiance measurements of the Quality Assurance of Spectral Ultraviolet Measurements in Europe through the Development of a Transportable Unit (QASUME) spectroradiometer and these three spectroradiometers have agreed to better than 6% during the ten intercomparison campaigns held from 2002 to 2004. If the differences in irradiance scales of as much as 2% are taken into account, the agreement is of the order of 4% over the wavelength range of 300-400 nm.

Journal Article↗

An improved algorithm for satellite-derived UV radiations.

The improved algorithm surface irradiance derived from a range of satellite-based sensors (SIDES) is presented in this article. It calculates various types of surface UV intensities, such as biologically weighted or unweighted UV spectra, integrated doses or irradiance at specific wavelengths, using data from satellite instruments. These surface UV data are mainly useful for environmental impact or process studies where high accuracy or a high temporal resolution is required. In contrast to several previous studies, SIDES has been validated with spectral measurements. By this method an averaging of positive or negative deviations over the complete wavelength range is avoided. This is especially important for UV wavelengths around 300 nm where biological effectiveness is highest. The results of SIDES deviate less than 7% from ground-based observations for wavelengths between 295 and 400 nm. In contrast, the corresponding deviations of the joint research center algorithm escalate for shorter wavelengths, reaching 35% at 295 nm. This large deviation is due to an inaccurate interpolation procedure that has been detected by spectral analysis. Thus, spectral validation is demonstrated to be an appropriate tool to detect weaknesses in such an algorithm and provides information essential for improvement.

Algorithms↗