Search PubMed⌕ Search

Biomedical subjects

Gultekin Gulsen

Publications and source records attributed to Gultekin Gulsen.

8 recordsLinked to original sources

Combined diffuse optical tomography (DOT) and MRI system for cancer imaging in small animals.

Recently, there has been a great amount of interest in developing multi-modality imaging techniques for oncologic research and clinical studies with the aim of obtaining complementary information and, thus, improving the detection and characterization of tumors. In this present work, the details of a combined MR-diffuse optical imaging system for dual-modality imaging of small animals are given. As a part of this effort, a multi-spectral frequency domain diffuse optical tomography system is integrated with an MRI system. Here, a network analyzer provides the rf modulation signal for the laser diodes and measures the amplitude and the phase of the detected signals. Photomultiplier tubes are utilized to measure low-level signals. The integration of this optical imaging system with the 4T MRI system is realized by incorporating a fiber adaptive interface inside the MR magnet. Coregistration is achieved by a special probe design utilizing fiducial markers. A finite element algorithm is used to solve the diffusion equation and an inverse solver based on this forward solver is implemented to calculate the absorption and scattering maps from the acquired data. The MR a priori information is used to guide the optical reconstruction algorithm. Phantom studies show that the absorption coefficient of a 7 mm inclusion in an irregular object located in 64 mm phantom is recovered with 11% error when MR a priori information is used. ENU induced tumor model is used to test the performance of the system in vivo.

Algorithms↗

In vivo quantification of optical contrast agent dynamics in rat tumors by use of diffuse optical spectroscopy with magnetic resonance imaging coregistration.

We present a study of the dynamics of optical contrast agents indocyanine green (ICG) and methylene blue (MB) in an adenocarcinoma rat tumor model. Measurements are conducted with a combined frequency-domain and steady-state optical technique that facilitates rapid measurement of tissue absorption in the 650-1000-nm spectral region. Tumors were also imaged by use of contrast-enhanced magnetic resonance imaging (MRI) and coregistered with the location of the optical probe. The absolute concentrations of contrast agent, oxyhemoglobin, deoxyhemoglobin, and water are measured simultaneously each second for approximately 10 min. The differing tissue uptake kinetics of ICG and MB in these late-stage tumors arise from differences in their effective molecular weights. ICG, because of its binding to plasma proteins, behaves as a macromolecular contrast agent with a low vascular permeability. A compartmental model describing ICG dynamics is used to quantify physiologic parameters related to capillary permeability. In contrast, MB behaves as a small-molecular-weight contrast agent that leaks rapidly from the vasculature into the extravascular, extracellular space, and is sensitive to blood flow and the arterial input function.

Adenocarcinoma↗

Coregistration of diffuse optical spectroscopy and magnetic resonance imaging in a rat tumor model.

We report coregistration of near-infrared diffuse optical spectroscopy (DOS) and magnetic resonance imaging (MRI) for the study of animal model tumors. A combined broadband steady-state and frequency-domain apparatus was used to determine tissue oxyhemoglobin, deoxyhemoglobin, and water concentration locally in tumors. Simultaneous MRI coregistration provided structural (T2-weighted) and contrast-enhanced images of the tumor that were correlated with the optical measurements. By use of Monte Carlo simulations, the optically sampled volume was superimposed on the MR images, showing precisely which tissue structure was probed optically. DOS and MRI coregistration measurements were performed on seven rats over 20 days and were separated into three tumor tissue classifications: viable, edematous, and necrotic. A ratio of water concentration to total hemoglobin concentration, as measured optically, was performed for each tissue type and showed values for edematous tissue to be greater than viable tissue (1.2 +/- 0.49 M/microM versus 0.48 +/- 0.15 M/microM). Tissue hemoglobin oxygen saturation (StO2) also showed a large variation between tissue types: viable tissue had an optically measured StO2 value of 61 +/- 5%, whereas StO2 determined for necrotic tissue was 43 +/- 6%.

Adenocarcinoma↗

Automatic tuned MRI RF coil for multinuclear imaging of small animals at 3T.

We have developed an MRI RF coil whose tuning can be adjusted automatically between 120 and 128 MHz for sequential spectroscopic imaging of hydrogen and fluorine nuclei at field strength 3 T. Variable capacitance (varactor) diodes were placed on each rung of an eight-leg low-pass birdcage coil to change the tuning frequency of the coil. The diode junction capacitance can be controlled by the amount of applied reverse bias voltage. Impedance matching was also done automatically by another pair of varactor diodes to obtain the maximum SNR at each frequency. The same bias voltage was applied to the tuning varactors on all rungs to avoid perturbations in the coil. A network analyzer was used to monitor matching and tuning of the coil. A Pentium PC controlled the analyzer through the GPIB bus. A code written in LABVIEW was used to communicate with the network analyzer and adjust the bias voltages of the varactors via D/A converters. Serially programmed D/A converter devices were used to apply the bias voltages to the varactors. Isolation amplifiers were used together with RF choke inductors to provide isolation between the RF coil and the DC bias lines. We acquired proton and fluorine images sequentially from a multicompartment phantom using the designed coil. Good matching and tuning were obtained at both resonance frequencies. The tuning and matching of the coil were changed from one resonance frequency to the other within 60 s.

Animals↗

A double end-cap birdcage RF coil for small animal whole body imaging.

Proper design of a birdcage coil plays a very important role in obtaining high-resolution small animal magnetic resonance imaging. The RF field homogeneity and the coil filling factor directly affect the signal-to-noise ratio (S/N) and therefore limit the resolution. It has been shown that a conductive end-cap placed on one side of the coil can improve the RF field inhomogeneity near this area. This also contributes to an increase in the S/N by reducing the length of the RF coil. While this is true near the end-cap, the distal half of the coil still suffers from poor homogeneity and S/N. Consequently, such a shortfall may hinder small animal whole body imaging. In order to improve the coil performance for a larger imaging volume, we designed a new small animal birdcage RF coil by adding a detachable second end-cap to the open end. The performance of single end and double end RF coils was compared experimentally. The results indicate that the double end-cap can provide superior uniformity along the long axis of the coil. Furthermore, if one wishes to obtain the same homogeneity within a given volume, a double end-cap would have less than half of the length of the single end-cap coil leading to a superior S/N performance.

Animals↗

Congruent MRI and near-infrared spectroscopy for functional and structural imaging of tumors.

We present a combined near-infrared diffuse optical spectroscopy (DOS) and Magnetic Resonance Imaging (MRI) system for the study of animal model tumors. A combined broadband steady-state and frequency domain optical spectroscopy apparatus was integrated with the MRI. The physiological properties of tissue rendered by MRI, including vascular volume fraction and water, were compared with chromophore concentrations as determined from the parameters obtained by optical measurements. DOS measurements provided oxy-hemoglobin, deoxy-hemoglobin, and water concentration locally in tumors. A method for co-registration of the information obtained by both modalities was developed. Using Monte Carlo simulations, the optically sampled volume was superimposed on the MR images, illustrating which tissue structure was probed optically. Finally, two optical contrast agents, indocyanine green (ICG) and methylene blue (MB), were employed and their kinetics were measured by DOS system from different locations on the tumor and compared with Gd-DTPA enhancement maps obtained from MRI.

Animals↗

Design and implementation of a multifrequency near-infrared diffuse optical tomography system.

The design and implementation of a multifrequency and multispectral diffuse optical tomography system is described. Four wavelengths are utilized: 665, 785, 808, and 830 nm. The system is based on a network analyzer, which provides rf modulation signals for the laser diodes, as well as measures the amplitude and the phase of the detected signals. Six different modulation frequencies ranging from 110 to 280 MHz are used. The details of instrumentation, calibration, data acquisition, and performance of the system are given. A finite element algorithm is used to solve the diffusion equation, and an inverse solver based on this forward solver is implemented to calculate the absorption and scattering maps from the acquired data. Data acquisition for one wavelength is completed in less than 2.5 min for a single modulation frequency. The measurement repeatability is 0.5% in ac intensity and 0.2 deg in phase. The performance of the system is evaluated with phantom studies. A multifrequency reconstruction algorithm is used, in which a single absorption and scattering image pair is obtained using the whole dataset obtained at different modulation frequencies. It is shown that the multifrequency reconstruction approach provides superior image quality compared to the single frequency counterpart.

Equipment Design↗

Diffuse optical tomographic reconstruction using multifrequency data.

We investigated the use of multifrequency diffuse optical tomography (MF-DOT) data for the reconstruction of the optical parameters. The experiments were performed in a 63 mm diameter cylindrical phantom containing a 15 mm diameter cylindrical object. Modulation frequencies ranging from 110 MHz to 280 MHz were used in the phantom experiments changing the contrast in absorption of the object with respect to the phantom while keeping the scattering value the same. The diffusion equation was solved using the finite element method. The sensitivity information from each frequency was combined to form a single Jacobian. The inverse problem was solved iteratively by minimizing the difference between the measurements and forward problem using single and multiple modulation frequency data. A multiparameter Tikhonov scheme was used for regularization. The phantom results show that the peak absorption coefficient in a region of interest was obtained with an error less then 5% using two-frequency reconstruction for absorption contrast values up to 2.2 times higher than background and 10% for the absorption contrast values larger than 2.2. The use of two-frequency data is sufficient to improve the quantitative accuracy compared with the single frequency reconstruction with appropriate selection of these frequencies.

Algorithms↗