In vivo characterization of coronary atherosclerotic plaque by use of optical coherence tomography.

BACKGROUND: The current understanding of the pathophysiology of coronary artery disease is based largely on postmortem studies. Optical coherence tomography (OCT) is a high-resolution ( approximately 10 microm), catheter-based imaging modality capable of investigating detailed coronary plaque morphology in vivo. METHODS AND RESULTS: Patients undergoing cardiac catheterization were enrolled and categorized according to their clinical presentation: recent acute myocardial infarction (AMI), acute coronary syndromes (ACS) constituting non-ST-segment elevation AMI and unstable angina, or stable angina pectoris (SAP). OCT imaging was performed with a 3.2F catheter. Two observers independently analyzed the images using the previously validated criteria for plaque characterization. Of 69 patients enrolled, 57 patients (20 with AMI, 20 with ACS, and 17 with SAP) had analyzable images. In the AMI, ACS, and SAP groups, lipid-rich plaque (defined by lipid occupying > or =2 quadrants of the cross-sectional area) was observed in 90%, 75%, and 59%, respectively (P=0.09). The median value of the minimum thickness of the fibrous cap was 47.0, 53.8, and 102.6 microm, respectively (P=0.034). The frequency of thin-cap fibroatheroma (defined by lipid-rich plaque with cap thickness < or =65 microm) was 72% in the AMI group, 50% in the ACS group, and 20% in the SAP group (P=0.012). No procedure-related complications occurred. CONCLUSIONS: OCT is a safe and effective modality for characterizing coronary atherosclerotic plaques in vivo. Thin-cap fibroatheroma was more frequently observed in patients with AMI or ACS than SAP. This is the first study to compare detailed in vivo plaque morphology in patients with different clinical presentations.

Aged↗

Focal and multi-focal plaque macrophage distributions in patients with acute and stable presentations of coronary artery disease.

OBJECTIVES: This study was designed to utilize optical coherence tomography (OCT) images of coronary atherosclerotic plaque macrophages to investigate the relationship between macrophage distributions and clinical syndrome. BACKGROUND: The relative significance of focal macrophage infiltration and generalized coronary inflammation for predicting acute coronary events is a currently a source of considerable controversy in cardiology. Lack of a high-resolution cross-sectional imaging modality has limited macrophage evaluation in vivo. METHODS: Intracoronary OCT imaging was performed at culprit and non-culprit plaques in patients presenting with stable angina pectoris, unstable angina pectoris,and ST-segment elevation myocardial infarction. Macrophage densities were quantified from these images and analyzed with respect to the clinical presentations of the patients under investigation. RESULTS: A significantly greater macrophage density was found in unstable patients, both for fibrous and lipid-rich plaques (p = 0.025 and p = 0.002, respectively). Within each patient, the macrophage densities at culprit and non-culprit lesions correlated significantly (r = 0.66, y = 0.88x + 0.43, p = 0.01). Sites of plaque rupture demonstrated a greater macrophage density than non-ruptured sites (6.95 +/- 1.60%, 5.29 +/- 1.17%; p = 0.002). Surface macrophage infiltration was a stronger predictor of unstable clinical presentation than subsurface infiltration for culprit lesions (p = 0.035) but not for remote lesions (p = 0.80). CONCLUSIONS: Our results demonstrate that increases in both multi-focal and focal macrophage densities are highly correlated with symptom severity. By providing a means of detecting increases in plaque macrophage content before an acute event, this technique may aid in determining prognosis and guiding preventive therapy.

Aged↗

Generating an adjustable three-dimensional dark focus.

Conditions for generating a dark focus surrounded by light in all three dimensions are presented. A simple technique for generating such a dark region is demonstrated experimentally. The method is compared with previous attempts at creating a three-dimensional dark focus.

Journal Article↗

In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography.

An ultrahigh-speed spectral domain optical coherence tomography (SD-OCT) system is presented that achieves acquisition rates of 29,300 depth profiles/s. The sensitivity of SD-OCT and time domain OCT (TD-OCT) are experimentally compared, demonstrating a 21.7-dB improvement of SD-OCT over TD-OCT. In vivo images of the human retina are presented, demonstrating the ability to acquire high-quality structural images with an axial resolution of 6 microm at ultrahigh speed and with an ocular exposure level of less than 600 microW.

Humans↗

Mechanical analysis of atherosclerotic plaques based on optical coherence tomography.

Finite element analysis is a powerful tool for investigating the biomechanics of atherosclerosis and has thereby provided an improved understanding of acute myocardial infarction. Structural analysis of arterial walls is traditionally performed using geometry contours derived from histology. In this paper we demonstrate the first use of a new imaging technique, optical coherence tomography (OCT), as a basis for finite element analysis. There are two primary benefits of OCT relative to histology: 1) imaging is performed without excessive tissue handling, providing a more realistic geometry than histology and avoiding structural artifacts common to histologic processing, and 2) OCT imaging can be performed in vivo, making it possible to study disease progression and the effect of therapeutic treatments in animal models and living patients. Patterns of mechanical stress and strain distributions computed from finite element analysis based on OCT were compared with those from modeling based on "gold standard" histology. Our results indicate that vascular structure and composition determined by OCT provides an adequate basis for investigating the biomechanical factors relevant to atherosclerosis and acute myocardial infarction.

Coronary Artery Disease↗

Quantification of macrophage content in atherosclerotic plaques by optical coherence tomography.

BACKGROUND: Macrophage degradation of fibrous cap matrix is an important contributor to atherosclerotic plaque instability. An imaging technology capable of identifying macrophages in patients could provide valuable information for assessing plaque vulnerability. Optical coherence tomography (OCT) is a new intravascular imaging modality that allows cross-sectional imaging of tissue with a resolution of approximately 10 micro m. The aim of this study was to investigate the use of OCT for identifying macrophages in fibrous caps. METHODS AND RESULTS: OCT images of 26 lipid-rich atherosclerotic arterial segments obtained at autopsy were correlated with histology. Cap macrophage density was quantified morphometrically by immunoperoxidase staining with CD68 and smooth muscle actin and compared with the standard deviation of the OCT signal intensity at corresponding locations. There was a high degree of positive correlation between OCT and histological measurements of fibrous cap macrophage density (r=0.84, P<0.0001) and a negative correlation between OCT and histological measurements of smooth muscle actin density (r=-0.56, P<0.005). A range of OCT signal standard deviation thresholds (6.15% to 6.35%) yielded 100% sensitivity and specificity for identifying caps containing >10% CD68 staining. CONCLUSIONS: The high contrast and resolution of OCT enables the quantification of macrophages within fibrous caps. The unique capabilities of OCT for fibrous cap characterization suggest that this technology may be well suited for identifying vulnerable plaques in patients.

Actins↗

Characterization of human atherosclerosis by optical coherence tomography.

BACKGROUND: High-resolution visualization of atherosclerotic plaque morphology may be essential for identifying coronary plaques that cause acute coronary events. Optical coherence tomography (OCT) is an intravascular imaging modality capable of providing cross-sectional images of tissue with a resolution of 10 micro m. To date, OCT imaging has not been investigated in sufficient detail to assess its accuracy for characterizing atherosclerotic plaques. The aim of this study was to establish objective OCT image criteria for atherosclerotic plaque characterization in vitro. METHODS AND RESULTS: OCT images of 357 (diseased) atherosclerotic arterial segments obtained at autopsy were correlated with histology. OCT image criteria for 3 types of plaque were formulated by analysis of a subset (n=50) of arterial segments. OCT images of fibrous plaques were characterized by homogeneous, signal-rich regions; fibrocalcific plaques by well-delineated, signal-poor regions with sharp borders; and lipid-rich plaques by signal-poor regions with diffuse borders. Independent validation of these criteria by 2 OCT readers for the remaining segments (n=307) demonstrated a sensitivity and specificity ranging from 71% to 79% and 97% to 98% for fibrous plaques, 95% to 96% and 97% for fibrocalcific plaques, and 90% to 94% and 90% to 92% for lipid-rich plaques, respectively (overall agreement, kappa=0.83 to 0.84). The interobserver and intraobserver reliabilities of OCT assessment were high (kappa values of 0.88 and 0.91, respectively). CONCLUSIONS: Objective OCT criteria are highly sensitive and specific for characterizing different types of atherosclerotic plaques. These results represent an important step in validating this new intravascular imaging modality and will provide a basis for the interpretation of intracoronary OCT images obtained from patients.

Aged↗

Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound.

OBJECTIVES: The aim of this study was to evaluate the feasibility and the ability of intravascular optical coherence tomography (OCT) to visualize the components of coronary plaques in living patients. BACKGROUND: Disruption of a vulnerable coronary plaque with subsequent thrombosis is currently recognized as the primary mechanism for acute myocardial infarction. Although such plaques are considered to have a thin fibrous cap overlying a lipid pool, imaging modalities in current clinical practice do not have sufficient resolution to identify thin (< 65 microm) fibrous caps. Optical coherence tomography is a new imaging modality capable of obtaining cross-sectional images of coronary vessels at a resolution of approximately 10 microm. METHODS: The OCT images and corresponding histology of 42 coronary plaques were compared to establish OCT criteria for different types of plaques. Atherosclerotic lesions with mild to moderate stenosis were identified on angiograms in 10 patients undergoing cardiac catheterization. Optical coherence tomography and intravascular ultrasound (IVUS) images of these sites were obtained in all patients without complication. RESULTS: Comparison between OCT and histology demonstrated that lipid-rich plaques and fibrous plaques have distinct OCT characteristics. A total of 17 IVUS and OCT image pairs obtained from patients were compared. Axial resolution measured 13 +/- 3 microm with OCT and 98 +/- 19 microm with IVUS. All fibrous plaques, macrocalcifications and echolucent regions identified by IVUS were visualized in corresponding OCT images. Intimal hyperplasia and echolucent regions, which may correspond to lipid pools, were identified more frequently by OCT than by IVUS. CONCLUSIONS: Intracoronary OCT appears to be feasible and safe. Optical coherence tomography identified most architectural features detected by IVUS and may provide additional detailed structural information.

Cardiac Catheterization↗

Optical coherence tomography of the biliary tree during ERCP.

BACKGROUND: Optical coherence tomography (OCT) is a high-resolution imaging technique that produces cross-sectional images in vivo. This is a report of the first use of OCT to acquire images of the biliary tree during ERCP. METHODS: A 2.6-mm diameter OCT catheter delivered through the accessory channel of a duodenoscope was used to acquire images of the intrahepatic and extrahepatic bile ducts in 5 patients. Histology-correlated OCT images of 5 cadaveric livers, each imaged at 3 sites, were used to guide interpretation of the in vivo images. RESULTS: Biliary ductal epithelium and subepithelial structures, including peribiliary glands, vasculature, and hepatic parenchyma, were visualized in vivo. The papillary architecture of cholangiocarcinoma was identified by OCT. There were no OCT-related complications. CONCLUSIONS: High-resolution OCT imaging of the biliary tree is feasible and may provide useful diagnostic information during ERCP.