Search PubMed⌕ Search

Biomedical subjects

Guenter Martin

Publications and source records attributed to Guenter Martin.

2 recordsLinked to original sources

New SPUDT cell structures.

The present paper describes single-phase unidirectional transducers (SPUDT) cells with all fingers wider than lambda/8 while maintaining the unidirectional effect. The first solution is related to a SPUDT consisting of lambda/4 and lambda/2 wide fingers arranged in two tracks. Each track has no significant unidirectional effect. Both tracks form a waveguide, and the waveguide coupling generates the interaction of the tracks. As a result of that interaction, a unidirectional effect arises as verified by experiment. This transducer type is called double-track (DT) SPUDT. A second solution is suggested that includes, in contrast to distributed acoustic reflection transducer (DART), electrode width control (EWC), and Hunsinger cells, SPUDT cell fingers with one and the same width only. Cell types with lambda/6, lambda/5, and lambda/3 wide fingers called uniform width electrode (UWE) cells are considered. One of these cell types, including exclusively lambda/5 wide fingers, is experimentally investigated and a unidirectional effect is found. Moreover, a filter example using the lambda/5 cell type has been designed for reducing SPUDT reflections. The echo suppression expected could be verified experimentally. No waveguide coupling is required for this cell type.

Journal Article↗

SAW filters including one-focus slanted finger interdigital transducers.

The present paper describes a new filter type, slanted finger interdigital transducer (SFIT) that allows fast analysis as a precondition for fast optimization. Therefore, filter structure and analysis are especially suitable for optimizing unidirectional SFIT (USFIT) filters. For analysis, a SFIT filter is usually divided into many narrow channels. Every channel is considered to be a subfilter and is analyzed separately. Therefore, the total filter analysis is very time consuming. For reducing computing time, we suggest a one-focus structure. In contrast to conventional SFIT filters, not only the finger and gap widths but also the spaces between transducers of different channels differ by one and the same scaling factor. As a consequence, all prolonged finger edges of both transducers intersect in one point called focus. As a result, the parameters of all subfilters can be calculated from the parameters of only one subfilter by simple frequency scaling. Consequently, the total time for analysis is essentially reduced. However, one-focus SFIT filters with continuous finger edges show a deep minimum within the passband. This problem can be overcome by using stepped one-focus structures.

Letter↗