Search PubMed⌕ Search

Biomedical subjects

Guenter Gauglitz

Publications and source records attributed to Guenter Gauglitz.

11 recordsLinked to original sources

Development of a TIRF-based biosensor for sensitive detection of progesterone in bovine milk.

A total internal reflectance fluorescence (TIRF)-based biosensor for progesterone in bovine milk was developed and tested by measuring the progesterone level in daily milk samples for 25 days, covering a whole estrus cycle. The detection is based on total internal reflectance fluorescence. The assay has been designed as a binding-inhibition test with a progesterone derivative covalently immobilized on the sensor surface and a monoclonal anti-progesterone antibody as biological recognition element. First an existing progesterone assay was optimized by reducing the assay time per measurement, resulting in an assay time of about 5 min and reaching a limit of detection (LOD) of 0.04 ng mL(-1) and a quantification limit (LOQ) of 0.34 ng mL(-1). After calibration the assay was tested by measuring the progesterone level in daily milk samples over several weeks. An estrus cycle of a cow could be measured. As results become available within minutes without any preparation or pre-concentration of the milk samples the fully automated TIRF-based biosensor for progesterone can be used in-line in the milking parlor and thus could be an important tool for reproductive management of dairy cattle detecting heat and predicting pregnancy, which are critical parameters in milk production.

Animals↗

Improved strategy for biosensor-based monitoring of water bodies with diverse organic carbon levels.

To protect water resources and to control the water quality it is necessary to develop fast, sensitive, cost-effective, and easy-to-use analytical systems, which are able to measure a variety of contaminants in water. Monitoring water bodies with various matrices can be very difficult. The diverse organic carbon level in water samples (e.g. river water or seawater) causes problems at common analysis and in particular at immunological methods. Here, we demonstrate a new method to overcome the partly occurring matrix problems at quasi-continuous real-world biosensor monitoring. Therefore, we developed an easy matrix referencing method for our fully automated immunoassays that could be adapted to other applications depending on a similar test-format. The method was developed using a synthetic organic carbon standard, and validated using a diluted turf extract. Results for the ultra-sensitive immunoassay for estrone quantification are shown as example. The developed method was verified using immunoassays for testosterone, progesterone, ethinylestradiol, estradiol, and estriol.

Algorithms↗

TIRF-based biosensor for sensitive detection of progesterone in milk based on ultra-sensitive progesterone detection in water.

We report on recent advances of our immunoassay for the hormone progesterone in cow's milk. Detection is based on total internal reflectance fluorescence (TIRF), the binding-inhibition assay with an immobilized progesterone derivative, and a commercially available monoclonal antibody to progesterone as biological recognition element. The fully automated River Analyzer (RIANA) biosensor for unattended, cost-effective, and continuous monitoring of environmental pollution therefore was adapted for sensitive determination of progesterone in milk. First, the sensitivity and robustness of the existing progesterone assay for water analysis were improved, resulting in a detection limit (LOD) of only 0.2 pg mL(-1) and a quantification limit (LOQ) of only 2.0 pg mL(-1). These extraordinary results are the lowest detection and quantification limits for progesterone determination using biosensors yet reported in the literature. Second, the accurate indicator of ovulation was calibrated and detected in three different types of milk (UHT milk, fresh milk, and raw milk). For commercial milk and randomly procured raw milk nominal levels of progesterone are typically in the range 5-15 ng mL(-1). Limits of detection (LOD) achieved for added progesterone (i.e. spiked samples) were between 45.5 and 56.1 pg mL(-1) depending on milk type. Having in mind the 1:10 dilution factor, these results are still a success. For the first time a commercially available antibody was incorporated into an immunoassay for progesterone detection in bovine milk, giving a detection limit below 1 ng mL(-1) for a fully automated biosensor. Thus the outstanding progress made with this biosensor in environmental monitoring and water analysis has now been successfully adapted to milk analysis for use in the field of reproduction management.

Animals↗

Automated water analyser computer supported system (AWACSS) Part I: Project objectives, basic technology, immunoassay development, software design and networking.

A novel analytical system AWACSS (automated water analyser computer-supported system) based on immunochemical technology has been developed that can measure several organic pollutants at low nanogram per litre level in a single few-minutes analysis without any prior sample pre-concentration nor pre-treatment steps. Having in mind actual needs of water-sector managers related to the implementation of the Drinking Water Directive (DWD) (98/83/EC, 1998) and Water Framework Directive WFD (2000/60/EC, 2000), drinking, ground, surface, and waste waters were major media used for the evaluation of the system performance. The instrument was equipped with remote control and surveillance facilities. The system's software allows for the internet-based networking between the measurement and control stations, global management, trend analysis, and early-warning applications. The experience of water laboratories has been utilised at the design of the instrument's hardware and software in order to make the system rugged and user-friendly. Several market surveys were conducted during the project to assess the applicability of the final system. A web-based AWACSS database was created for automated evaluation and storage of the obtained data in a format compatible with major databases of environmental organic pollutants in Europe. This first part article gives the reader an overview of the aims and scope of the AWACSS project as well as details about basic technology, immunoassays, software, and networking developed and utilised within the research project. The second part article reports on the system performance, first real sample measurements, and an international collaborative trial (inter-laboratory tests) to compare the biosensor with conventional anayltical methods.

Algorithms↗

Automated Water Analyser Computer Supported System (AWACSS) Part II: Intelligent, remote-controlled, cost-effective, on-line, water-monitoring measurement system.

A novel analytical system AWACSS (Automated Water Analyser Computer Supported System) based on immunochemical technology has been evaluated that can measure several organic pollutants at low nanogram per litre level in a single few-minutes analysis without any prior sample pre-concentration or pre-treatment steps. Having in mind actual needs of water-sector managers related to the implementation of the Drinking Water Directive (DWD) [98/83/EC, 1998. Council Directive (98/83/EC) of 3 November 1998 relating to the quality of water intended for human consumption. Off. J. Eur. Commun. L330, 32-54] and Water Framework Directive (WFD) [2000/60/EC, 2000. Directive 2000/60/EC of the European Parliament and of the Council of 23 October 2000 establishing a framework for Community action in the field of water policy. Off. J. Eur. Commun. L327, 1-72], drinking, ground, surface, and waste waters were major media used for the evaluation of the system performance. The first part article gave the reader an overview of the aims and scope of the AWACSS project as well as details about basic technology, immunoassays, software, and networking developed and utilised within the research project. The second part reports on the system performance, first real sample measurements, and an international collaborative trial (inter-laboratory tests) to compare the biosensor with conventional anayltical methods. The systems' capability for analysing a wide range of environmental organic micro-pollutants, such as modern pesticides, endocrine disrupting compounds and pharmaceuticals in surface, ground, drinking and waste water is shown. In addition, a protocol using reconstitution of extracts of solid samples, developed and applied for analysis of river sediments and food samples, is presented. Finally, the overall performance of the AWACSS system in comparison to the conventional analytical techniques, which included liquid and gas chromatographic systems with diode-array UV and mass spectrometric detectors, was successfully tested in an inter-laboratory collaborative trial among six project partners.

Algorithms↗

Direct optical sensors: principles and selected applications.

In the field of bio and chemosensors a large number of detection principles has been published within the last decade. These detection principles are based either on the observation of fluorescence-labelled systems or on direct optical detection in the heterogeneous phase. Direct optical detection can be measured by remission (absorption of reflected radiation, opt(r)odes), by measuring micro-refractivity, or measuring interference. In the last case either Mach-Zehnder interferometers or measurement of changes in the physical thickness of the layer (measuring micro-reflectivity) caused, e.g., by swelling effects in polymers (due to interaction with analytes) or in bioassays (due to affinity reactions) also play an important role. Here, an overview of methods of microrefractometric and microreflectometric principles is given and benefits and drawbacks of the various approaches are demonstrated using samples from the chemo and biosensor field. The quality of sensors does not just depend on transduction principles but on the total sensor system defined by this transduction, the sensitive layer, data acquisition electronics, and evaluation software. The intention of this article is, therefore, to demonstrate the essentials of the interaction of these parts within the system, and the focus is on optical sensing using planar transducers, because fibre optical sensors have been reviewed in this journal only recently. Lack of selectivity of chemosensors can be compensated either by the use of sensor arrays or by evaluating time-resolved measurements of analyte/sensitive layer interaction. In both cases chemometrics enables the quantification of analyte mixtures. These data-processing methods have also been successfully applied to antibody/antigen interactions even using cross-reactive antibodies. Because miniaturisation and parallelisation are essential approaches in recent years, some aspects and current trends, especially for bio-applications, will be discussed. Miniaturisation is especially well covered in the literature.

Journal Article↗

Verification of performance with the automated direct optical TIRF immunosensor (River Analyser) in single and multi-analyte assays with real water samples.

In order to verify the reproducibility, precision, and robustness of the optical immunosensor River Analyser (RIANA), we investigated two common statistical methods to evaluate the limit of detection (LOD) and the limit of quantification (LOQ). Therefore, we performed a simultaneous multi-analyte calibration with atrazine, bisphenol A, and estrone in Milli-Q water. Using an automated biosensor, it was possible for the first time to achieve a LOD below 0.020 microg L(-1) using a common statistically based method without sample pre-treatment and pre-concentration for each of the analytes in a simultaneous multi-analyte calibration. This biosensor setup shows values comparable to those obtained by more classical analytical methods. Based on this calibration, we measured spiked and un-spiked real water samples with complex matrices (samples from different water bodies, from ground water sources, and tap water samples). The comparison between our River Analyser and common analytical methods (like GC-MS and HPLC-DAD) shows overall comparable values for all three analytes. Furthermore, a calibration of isoproturon (IPU) (in single analyte mode) resulted in a LOD of 0.016 microg L(-1), and a LOQ of 0.091 microg L(-1). In compliance with guidelines of the Association of Analytical Communities International (AOAC), six out of nine recovery rates (recovery rate: measured concentration divided by real concentration in percent) for three surface water samples with different matrices (spiked and un-spiked) could be obtained between 70 and 120% (recovery rates between 70 and 120%, as demanded by the guidelines of the AOAC International). The reproducibility was checked by measuring replica of each sample within independent repetitions. Robustness could be demonstrated by long-term stability tests of the biosensor surface. These studies show that the biosensor used offers the necessary reproducibility, precision, and robustness required for an analytical method.

Atrazine↗

Ultra-sensitive fully automated immunoassay for detection of propanil in aqueous samples: steps of progress toward sub-nanogram per liter detection.

The widely-used pesticide propanil is a selective post-emergent general-use acetanilide herbicide registered for control of broadleaf and grass weeds in rice, small grain, and turf. Because broad application and quite heavy use of this herbicide lead to contaminated sites and, consequently, contaminated water, immunoanalytical methods with very low limits of detection (LOD) and low limits of quantification (LOQ) are becoming increasingly important for environmental analysis and, especially, for monitoring drinking-water quality. Environmental monitoring of pesticides, hormones, endocrine-disrupting chemicals, and antibiotics in aqueous samples (e.g. surface, ground, waste, or drinking water) with quite difficult matrices places large demands on chemical analysis. Biosensors have suitable characteristics such as efficiency in enabling very fast, sensitive, and cost-effective detection. Here we describe the steps of progress toward sub-nanogram per liter detection of propanil with a fully automated immunoassay. In contrast with common analytical methods such as GC-MS or HPLC-MS the biosensor used requires no sample pre-treatment and pre-concentration. The basis of our sensitive assay is an antibody with a high affinity constant toward propanil. During the optimization process, we compared different surface modifications (four different immobilized derivatives) and reduced the amount of antibody per sample. In fact, optimization of the assay resulted in an LOD of 0.6 ng L(-1) and an LOQ of 4.5 ng L(-1) without any sample pre-treatment and without pre-concentration. These results for propanil with the RIANA instrument, and its improved sensitivity for detection of a single pesticide at the low nanogram per liter range, show that biosensors can compete with common analytical methods in the field of water analysis.

Autoanalysis↗

Immunosensor for estrone with an equal limit of detection as common analytical methods.

Immunoanalytical methods at a very low limit of detection (LOD) and a low limit of quantification (LOQ) are becoming more and more important for environmental analysis and especially for monitoring drinking water quality. Biosensors have suitable characteristics such as efficiency in allowing very fast, sensitive, and cost-effective detection. Here we describe a fully automated immunoassay for estrone with a LOD below 0.20 ng L(-1) and a LOQ below 1.40 ng L(-1). In contrast to common analytical methods such as GC-MS or HPLC-MS, the biosensor used requires no sample pre-treatment and pre-concentration. The basis of our sensitive assay is the antibody with a high affinity constant towards estrone. The very low amount of antibody per sample results in low validation parameters (LOD, LOQ, and IC50), but this assay for estrone represents the current device-related limitation of the River Analyser (RIANA).

Automation↗

Optical multiple-analyte immunosensor for water pollution control.

A prototype of a portable optical immunosensor (called river analyser) has been developed. It can be applied for the monitoring of surface water quality. Antibodies carrying a fluorescent label are used for the specific recognition of pollutants, such as frequently applied pesticides. The transduction principle is based on total internal reflection fluorescence (TIRF). The outstanding advantage of the river analyser is, that at least three analytes can be detected simultaneously in one sample. Test cycles and fluid handling are automated and enable unattended measuring.

Calibration↗