Search PubMed⌕ Search

Biomedical subjects

Guang-Ming Xu

Publications and source records attributed to Guang-Ming Xu.

2 recordsLinked to original sources

[Microsurgical treatment of proximal anterior cerebral artery aneurysms].

OBJECTIVE: To explore clinic characteristics of proximal anterior cerebral artery aneurysms and analyzed operative techniques. METHODS: A review was performed of a total of 362 patients whose aneurysms were surgically treated from June 1995 to December 2003, the morbidity of A(1) aneurysms was 2.2%. To reviewed clinical data of 8 proximal anterior cerebral artery aneurysms patients. RESULTS: All of the aneurysms developed at the takeoff point of perforating arteries, the recurrent artery of Heubner in three cases, the medial proximal lenticulostriate artery in five cases. Six cases aneurysms projected posteriorly, two cases projected inferiorly in the surgical field. The shape of the aneurysms was saccular in all cases and diameter no larger than 5 mm in six cases. Patients were clipped satisfactorily, excellent condition in 7 patient, good condition in one. CONCLUSION: It is important to preserve the perforating arteries and use suitable clip by avoiding cerebral ischemia.

Adult↗

A high-throughput continuous sample introduction interface for microfluidic chip-based capillary electrophoresis systems.

The development of efficient sample introduction and pretreatment systems for microfluidic chip-based analytical systems is important for their application to real-life samples. In this work, world-to-chip interfacing was achieved by a novel flow-through sampling reservoir featuring a guided overflow design. The flow-through reservoir was fabricated on a 30 x 60 x 3 mm planar glass chip of crossed-channel design used for capillary electrophoresis separations. The 20-microL sample reservoir was produced from a section of plastic pipet tip and fixed at one end of the sampling channel. Sample change was performed by pumping 80-microL samples sandwiched between air segments at approximately 0.48 mL/min flow rate through the flow-through reservoir, introduced from an access hole on the bottom side of the chip. A filter paper collar wrapped tightly around the reservoir guided the overflowing sample solution into a plastic trough surrounding the reservoir and then to waste. The performance of the system was demonstrated in the separation and determination of FITC-labeled arginine, glycine, phenylalanine, and glutamic acid with LIF detection, by continuously introducing a train of different samples through the system without electrical interruption. Employing a separation channel of 4 cm (2-cm effective separation length) and 1.4-kV separation voltage, maximum throughputs of 80/h were achieved with <4.1% carryover and precisions ranging from 1.5% for arginine to 2.6% RSD (n = 11) for glycine. The sampling system was tested in the continuous monitoring of the derivatizing process of amino acids by FITC over a period of 4 h, involving 166 analytical cycles. An outstanding overall precision of 4.8% RSD (n = 166) was achieved for the fluorescein internal standard.

Journal Article↗