Search PubMed⌕ Search

Biomedical subjects

Greg Mills

Publications and source records attributed to Greg Mills.

4 recordsLinked to original sources

Minimum-error method for scattering problems in quantum mechanics: Two stable and efficient implementations.

We examine here, by using a simple example, two implementations of the minimum error method (MEM), a least-squares minimization for scattering problems in quantum mechanics, and show that they provide an efficient, numerically stable alternative to Kohn variational principle. MEM defines an error-functional consisting of the sum of the values of (HPsi - EPsi)2 at a set of grid points. The wave function Psi, is forced to satisfy the scattering boundary conditions and is determined by minimizing the least-squares error. We study two implementations of this idea. In one, we represent the wave function as a linear combination of Chebyshev polynomials and minimize the error by varying the coefficients of the expansion and the R-matrix (present in the asymptotic form of Psi). This leads to a linear equation for the coefficients and the R-matrix, which we solve by matrix inversion. In the other implementation, we use a conjugate-gradient procedure to minimize the error with respect to the values of Psi at the grid points and the R-matrix. The use of the Chebyshev polynomials allows an efficient and accurate calculation of the derivative of the wave function, by using Fast Chebyshev Transforms. We find that, unlike KVP, MEM is numerically stable when we use the R-matrix asymptotic condition and gives accurate wave functions in the interaction region.

Journal Article↗

Electronic states of linear Au clusters supported on metal surfaces: why are they like those of a particle in a box?

Scanning tunneling spectroscopy and microscopy show that the empty states of linear Au clusters supported on a metal surface behave as if they are the states of an electron in an empty one-dimensional box. We show here that certain difficulties of this description are removed by a particle-in-a-cylinder model. This interpretation is supported by density functional calculations.

Journal Article↗

A study of the reactions of molecular hydrogen with small gold clusters.

This work presents a study of reactions between neutral and negatively charged Au(n) clusters (n=2,3) and molecular hydrogen. The binding energies of the first and second hydrogen molecule to the gold clusters were determined using density functional theory (DFT), second order perturbation theory (MP2) and coupled cluster (CCSD(T)) methods. It is found that molecular hydrogen easily binds to neutral Au(2) and Au(3) clusters with binding energies of 0.55 eV and 0.71 eV, respectively. The barriers to H(2) dissociation on these clusters with respect to Au(n)H(2) complexes are 1.10 eV and 0.59 eV for n=2 and 3. Although negatively charged Au(n) (-) clusters do not bind molecular hydrogen, H(2) dissociation can occur with energy barriers of 0.93 eV for Au(2) (-) and 1.39 eV for Au(3) (-). The energies of the Au(2)H(2) (-) and Au(3)H(2) (-) complexes with dissociated hydrogen molecules are lower than the energies of Au(2) (-)+H(2) and Au(3) (-)+H(2) by 0.49 eV and 0.96 eV, respectively. There is satisfactory agreement between the DFT and CCSD(T) results for binding energies, but the agreement is not as good for barrier heights.

Journal Article↗

A pulsating coronary vessel phantom for two- and three-dimensional intravascular ultrasound studies.

The evaluation of new techniques for 2-D and 3-D intravascular ultrasound (US) imaging (IVUS) often requires the use of a pulsating coronary phantom. This study describes the design, construction and evaluation of a phantom simulating the pulsation of a human coronary artery for IVUS studies. Polyvinyl alcohol (PVA) cryogel was used as a tissue mimic for the coronary vessel, which was incorporated in a custom-built assembly. The phantom was programmed to pulsate under servomotor control, to model the pulsation of a normal coronary artery and 2-D IVUS images were obtained using an IVUS imaging catheter. To evaluate the performance of the phantom, the lumen area variation of the phantom was determined and compared with the programmed pulsation waveforms. Our results showed that phantom pulsation correlated well with the programmed pulsation waveform (r = 0.97). The deviation of the least squares line from the line of identity was calculated to be < 4%.

Coronary Vessels↗