Search PubMed⌕ Search

Biomedical subjects

Gordon S Kino

Publications and source records attributed to Gordon S Kino.

9 recordsLinked to original sources

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Exploring the chemical enhancement for surface-enhanced Raman scattering with Au bowtie nanoantennas.

Single metallic bowtie nanoantennas provide a controllable environment for surface-enhanced Raman scattering (SERS) of adsorbed molecules. Bowties have experimentally measured electromagnetic enhancements, enabling estimation of chemical enhancement for both the bulk and the few-molecule regime. Strong fluctuations of selected Raman lines imply that a small number of p-mercaptoaniline molecules on a single bowtie show chemical enhancement >10(7), much larger than previously believed, likely due to charge transfer between the Au surface and the molecule. This chemical sensitivity of SERS has significant implications for ultra-sensitive detection of single molecules.

Absorption↗

Toward nanometer-scale optical photolithography: utilizing the near-field of bowtie optical nanoantennas.

Optically resonant metallic bowtie nanoantennas are utilized as fabrication tools for the first time, resulting in the production of polymer resist nanostructures <30 nm in diameter at record low incident multiphoton energy densities. The nanofabrication is accomplished via nonlinear photopolymerization, which is initiated by the enhanced, confined optical fields surrounding the nanoantenna. The position, size, and shape of the resist nanostructures directly correlate with rigorous finite-difference time-domain computations of the field distribution, providing a nanometer-scale measurement of the actual field confinement offered by single optical nanoantennas. In addition, the size of the photoresist regions yields strong upper bounds on photoacid diffusion and resist resolution in SU-8, demonstrating a technique that can be generalized to the study of many current and yet-to-be-developed photoresist systems.

Color↗

Minimum-phase-function-based processing in frequency-domain optical coherence tomography systems.

We present a simple processing technique that uses the concept of minimum-phase functions to improve frequency-domain optical coherence tomography systems. Our approach removes the autocorrelation noise and therefore increases both the accessible depth range and the recovery accuracy. To our knowledge, this is the first time that the concept of minimum-phase functions has been applied to improve optical coherence tomography.

Algorithms↗

Demonstration of a folded Sagnac sensor array immune to polarization-induced signal fading.

We demonstrate a new folded Sagnac sensor array design that combines a Faraday rotator mirror and a polarization beam splitter to eliminate the optical noise pulses otherwise generated in a folded Sagnac sensor array. A depolarization scheme compatible with this configuration is also proposed and demonstrated experimentally. It is shown that this new configuration passively eliminates polarization-induced signal fading on every sensor in the array. The minimum detectable phase was measured to be approximately 1.1 microrad/square root of Hz, in agreement with theory.

Journal Article↗

Dual-axes confocal microscopy with post-objective scanning and low-coherence heterodyne detection.

We present a dual-axes confocal microscope that employs postobjective scanning and low-coherence heterodyne detection to collect vertical cross-sectional images from biological tissue with high axial resolution, reduced noise from scattered light, deep tissue penetration, and a large dynamic range. This architecture can be scaled down to millimeter dimensions with microelectromechanical systems technology for performance of in vivo optical biopsy.

Biopsy↗

Dual-axis confocal microscope for high-resolution in vivo imaging.

We describe a novel confocal microscope that uses separate low-numerical-aperture objectives with the illumination and collection axes crossed at angle theta from the midline. This architecture collects images in scattering media with high transverse and axial resolution, long working distance, large field of view, and reduced noise from scattered light. We measured transverse and axial (FWHM) resolution of 1.3 and 2.1 microm, respectively, in free space, and confirm subcellular resolution in excised esophageal mucosa. The optics may be scaled to millimeter dimensions and fiber coupled for collection of high-resolution images in vivo.

Humans↗

Confocal fluorescence microscope with dual-axis architecture and biaxial postobjective scanning.

We present a novel confocal microscope that has dual-axis architecture and biaxial postobjective scanning for the collection of fluorescence images from biological specimens. This design uses two low-numerical-aperture lenses to achieve high axial resolution and long working distance, and the scanning mirror located distal to the lenses rotates along the orthogonal axes to produce arc-surface images over a large field of view (FOV). With fiber optic coupling, this microscope can potentially be scaled down to millimeter dimensions via microelectromechanical systems (MEMS) technology. We demonstrate a benchtop prototype with a spatial resolution < or =4.4 microm that collects fluorescence images with a high SNR and a good contrast ratio from specimens expressing GFP. Furthermore, the scanning mechanism produces only small differences in aberrations over the image FOV. These results demonstrate proof of concept of the dual-axis confocal architecture for in vivo molecular and cellular imaging.

Animals↗

Dual-axes confocal reflectance microscope for distinguishing colonic neoplasia.

A dual-axes confocal reflectance microscope has been developed that utilizes a narrowband laser at 1310 nm to achieve high axial resolution, image contrast, field of view, and tissue penetration for distinguishing among normal, hyperplastic, and dysplastic colonic mucosa ex vivo. Light is collected off-axis using a low numerical aperture objective to obtain vertical image sections, with 4- to 5-microm resolution, at tissue depths up to 610 microm. Post-objective scanning enables a large field of view (610 x 640 microm), and balanced-heterodyne detection provides sensitivity to collect vertical sections at one frame per second. System optics are optimized to effectively reject out-of-focus scattered light without use of a low-coherence gate. This design is scalable to millimeter dimensions, and the results demonstrate the potential for a miniature instrument to detect precancerous tissues, and hence to perform in vivo histopathology.

Anatomy, Cross-Sectional↗