Evaluation of cardiac involvement following major orthopedic surgery.

BACKGROUND: Cardiovascular morbidity is frequent after non-cardiac surgery and the early recognition of cardiac involvement is an essential tool for clinical risk stratification and management. The aim of this study was to investigate the behavior of traditional and emerging cardiac markers, including NT-prohormone-brain natriuretic peptide (NT-proBNP) and ischemia-modified albumin (IMA), in the perioperative period in patients undergoing major uncomplicated orthopedic surgery. METHODS: A total of 37 patients undergoing major orthopedic surgery were longitudinally evaluated for NT-proBNP, IMA, cardiac troponin T (cTnT), creatine kinase isoenzyme MB and myoglobin 3 h before surgery and 4 and 72 h thereafter. RESULTS: NT-proBNP values were significantly increased at 72 h postoperative compared to both 3 h preoperative and 4 h postoperative (NT-proBNP: 20 vs. 4.5 pmol/L, p<0.001 and 20 vs. 5.9 pmol/L, p<0.001). IMA levels were significantly increased at 4 and 72 h postoperative vs. 3 h preoperative (132 vs. 113 kU/L, p=0.02 and 151 vs. 113 kU/L, p<0.001). In a stepwise regression model, the perioperative liquid amount and degree of modification in postoperative creatinine levels (delta-creatinine) were independently related to the NT-proBNP increase. CONCLUSIONS: The significant increase observed in NT-proBNP suggests that patients undergoing major uncomplicated orthopedic surgery may develop subclinical cardiac stress, presumably attributable to the considerable infusion of liquids. The clinical significance of this finding deserves further investigation, especially in patients at higher risk of heart failure.

Adolescent↗

Blood transfusions in athletes. Old dogmas, new tricks.

Blood doping consists of any illicit means used to increase and optimize oxygen delivery to the muscles and includes blood transfusions, administration of erythropoiesis-stimulating substances, blood substitutes, natural or artificial altitude facilities, and innovative gene therapies. The use of blood transfusion, an extremely straightforward, practical and effective means of increasing an athlete's red blood-cell supply in advance of competition, became rather popular in the 1970s, but it has suddenly declined following the widespread use of recombinant human erythropoietin among elite endurance athletes. Most recently, following implementation of reliable tests to screen for erythropoiesis-stimulating substances, blood transfusions have made a strong resurgence, as attested by several positive doping tests. Doping by blood transfusion can be classified as homologous, where the blood is infused into someone other than the donor, and autologous, where the blood donor and transfusion recipient are the same. The former case produces more clinically relevant side effects, but is easily detectable using current antidoping protocols based on erythrocyte phenotyping by flow cytometry and, eventually, erythrocyte genotyping by DNA testing. Since the donor and recipient blood are identical in autologous blood doping, this is less risky, though much more challenging to detect. Indirect strategies, relying on significant deviations from individual hematological profiles following autologous blood donation and reinfusion, are currently being investigated. For the time being, the storage of athletes' blood samples to allow testing and sanctioning of guilty athletes once a definitive test has been introduced may represent a reliable deterrent policy.

Blood Group Antigens↗

National survey on the pre-analytical variability in a representative cohort of Italian laboratories.

BACKGROUND: Owing to remarkable advances in automation, laboratory technology and informatics, the pre-analytical phase has become the major source of variability in laboratory testing. The present survey investigated the development of several pre-analytical processes within a representative cohort of Italian clinical laboratories. METHODS: A seven-point questionnaire was designed to investigate the following issues: 1a) the mean outpatient waiting time before check-in and 1b) the mean time from check-in to sample collection; 2) the mean time from sample collection to analysis; 3) the type of specimen collected for clinical chemistry testing; 4) the degree of pre-analytical automation; 5a) the number of samples shipped to other laboratories and 5b) the availability of standardised protocols for transportation; 6) the conditions for specimen storage; and 7) the availability and type of guidelines for management of unsuitable specimens. The questionnaire was administered to 150 laboratory specialists attending the SIMEL (Italian Society of Laboratory Medicine) National Meeting in June 2006. RESULTS: 107 questionnaires (71.3%) were returned. Data analysis revealed a high degree of variability among laboratories for the time required for check-in, outpatient sampling, sample transportation to the referral laboratory and analysis upon the arrival. Only 31% of laboratories have automated some pre-analytical steps. Of the 87% of laboratories that ship specimens to other facilities without sample preparation, 19% have no standardised protocol for transportation. For conventional clinical chemistry testing, 74% of the laboratories use serum evacuated tubes (59% with and 15% without serum separator), whereas the remaining 26% use lithium-heparin evacuated tubes (11% with and 15% without plasma separator). The storage period and conditions for rerun/retest vary widely. Only 63% of laboratories have a codified procedure for the management of unsuitable specimens, which are recognised by visual inspection (69%) or automatic detection (29%). Only 56% of the laboratories have standardised procedures for the management of unsuitable specimens, which vary widely on a local basis. CONCLUSIONS: The survey highlights broad heterogeneity in several pre-analytical processes among Italian laboratories. The lack of reliable guidelines encompassing evidence-based practice is a major problem for the standardisation of this crucial part of the testing process and represents a major challenge for laboratory medicine in the 2000s.

Automation↗

Interference of blood cell lysis on routine coagulation testing.

CONTEXT: Preanalytical factors influencing the reliability of laboratory testing are commonplace. It is traditionally accepted that hemolytic samples are unsuitable for coagulation assays because of the release of hemoglobin, intracellular components, and thromboplastic substances from damaged blood cells. OBJECTIVE: To evaluate the influence of blood cell lysis on routine coagulation testing. DESIGN: Twelve aliquots prepared by serial dilutions of homologous lysated samples collected from 10 different subjects, and displaying a final percentage of lysis ranging from 0% to 9.1%, were tested for prothrombin time, activated partial thromboplastin time, fibrinogen, and dimerized plasmin fragment D. Lysis was achieved by subjecting citrated whole blood to a freeze-thaw cycle. OUTCOME MEASURES: Interference from blood cell lysis on routine coagulation testing. RESULTS: Statistically significant increases in prothrombin time and dimerized plasmin fragment D were observed in samples containing final lysate concentrations of 0.5% and 2.7% respectively, whereas significant decreases were observed in activated partial thromboplastin time and fibrinogen in samples containing a final lysate concentration of 0.9%. The current analytical quality specifications for desirable bias are +/-2.0% for prothrombin time, +/-2.3% for activated partial thromboplastin time, and +/-4.8% for fibrinogen. Percent variations from the baseline values exceeding the current analytical quality specifications for desirable bias were achieved for lysate concentrations of 0.9% (prothrombin time and activated partial thromboplastin time) and 1.8% (fibrinogen), corresponding to average free plasma hemoglobin concentrations of 1.7 and 3.4 g/L, respectively. CONCLUSION: Our results confirm that, although slightly hemolyzed specimens might still be analyzable, a moderate blood cell lysis, as low as 0.9%, influences the reliability of routine coagulation testing. Because the interference in coagulation assays has a wide interindividual bias, we do not recommend lysis correction and we suggest that the most appropriate corrective measure should be free hemoglobin quantification and sample recollection.

Artifacts↗

Phlebotomy issues and quality improvement in results of laboratory testing.

Laboratory testing is an integral part of the decision-making process, and results of laboratory testing often strongly influence medical diagnoses and therapies. There is a long history of quality requirements in laboratory medicine, which have mainly concerned the analytic phase of this process. Owing to the substantial advances in technology, laboratory automation and analytic quality, there is increasing evidence that further quality improvements should be targeted to extra-analytic phases of laboratory testing. Objective difficulties to monitor most of the preanalytic variables which lie outside the direct control or supervision of the laboratory personnel, such as phlebotomy, call for effective educational and preventive policies. Owing to high personnel turnover rates, lack of understanding about good laboratory practices, and inadequate training, there are several opportunities for making errors during phlebotomy, which mainly concern patient misidentification and collection of unsuitable specimens for testing due to unsuited venous accesses, venous stasis, inappropriate collection devices and containers. Improved standardization of phlebotomy techniques, along with operative guidelines dissemination, continuous education, certification, and training of health care professionals involved in blood drawing responsibilities would enhance the chance of obtaining specimens of consistent quality, with favorable revenues for the health care system and the patient's outcome.

Bloodletting↗

Inhibitors in mild/moderate haemophilia A: an update.

The development of inhibitors in patients with mild/moderate hemophilia A is an increasingly recognized occurrence and is manifested by the patients' bleeding pattern becoming more severe. Inherited (hemophilia genetic mutations) and acquired (type and delivery of factor VIII replacement therapy) factors have been associated with an increased likelihood of developing factor VIII inhibitors. Although the use of bypassing agents (i.e. activated prothrombin complex concentrates and recombinant factor VII activated) has been demonstrated to be effective in controlling bleeding episodes in patients who develop factor VIII inhibitors, the limited data available in the literature are insufficient to determine the optimal approach to the eradication of inhibitors (i.e. immune tolerance induction, immunosuppression or both) for this group. Particular attention should be directed to the prevention of this complication in those patients with mild/moderate hemophilia recognized to be at increased risk of developing a factor VIII inhibitor. In conclusion, large prospective trials are warranted in order to elucidate the many still unclear pathogenic and therapeutic aspects of the development of inhibitors in patients with mild/moderate hemophilia A.

Blood Coagulation Factors↗

The efficacy of rituximab in the treatment of inhibitor-associated hemostatic disorders.

Rituximab is a chimeric anti-CD20 monoclonal antibody active against normal and malignant B cells which has proven to be effective in the therapy of CD-20 positive lymphomas. Its B-cell cytotoxic action has also been exploited in many non-malignant autoimmune disorders in which it has been used with the aim of interfering with the production of pathologic antibodies. The present knowledge regarding the use of rituximab in antibody-associated disorders of hemostasis (i.e. idiopathic thrombocytopenic purpura, thrombotic thrombocytopenic purpura, acquired hemophilia A, congenital hemophilia with inhibitors, acquired inhibitors against coagulation factors) is presented briefly in this review. The results suggest that rituximab can be useful in the treatment of disorders of hemostasis associated with inhibitor formation. Although collectively the number of patients treated is now quite substantial, most of the data are drawn from isolated case reports or descriptions of small, uncontrolled series. Large, prospective, randomized trials are, therefore, needed to confirm the positive, preliminary results.

Adolescent↗

Preanalytic indicators of laboratory performances and quality improvement of laboratory testing.

Laboratory diagnosis is traditionally a three-part process that develops within the preanalytic, analytic and post-analytic phases. There is consolidated evidence that lack of standardization and monitoring of preanalytic variables, including procedures for patient identification, sample collection, handling and processing has an adverse influence on the reliability of test results, consuming valuable healthcare resources and compromising the patient's outcome. The preanalytic phase enfolds the greatest potential for quality improvement, once reliable strategies are identified and applied. A comprehensive quality program should outstrip the traditional confines of clinical laboratories, encompassing reliable monitoring policies of the state of quality across the entire process. Such an approach requires the adoption of a reliable global quality monitoring system based on a core set of broad, evidence-based preanalytic performance measures. The present article synthesizes current evidence on this topic, defining a tentative approach for implementation of a preanalytic quality monitoring system in clinical laboratories.

Clinical Laboratory Information Systems↗

Lipoprotein[a] and the lipid profile in patients with systemic sclerosis.

BACKGROUND: Systemic sclerosis (SSc) is an autoimmune disorder of the connective tissue characterized by widespread vascular lesions and fibrosis, associated with endothelial dysfunction, that might finally promote occlusive vascular complications. Little is known so far on the lipid profile of these patients. METHODS: To investigate the potential contribution of lipid abnormalities in genesis and progression of vascular occlusive complications, an extensive lipid profile, including total cholesterol, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, triglycerides, total cholesterol to HDL-C ratio, the atherogenic index of plasma, lipoprotein[a] (Lp[a]) and high-sensitive C Reactive Protein (Hs-CRP), was assessed in 31 consecutive female SSc patients and 33 matched healthy controls. RESULTS: When compared to healthy matched controls, SSc patients displayed statistically significant differences in median and 25-75th percentile distribution of Lp[a] (110 mg/l, 51-389 mg/l vs. 79 mg/l, 29-149 mg/l; P =0.005) and in the mean concentration of Hs-CRP (4.49 +/- 5.06 mg/l vs. 1.36 +/- 1.19 mg/l; P =0.001), but not in the other lipid parameters. When compared to the current NCEP or AHA/ACC goals, the values distributions and the relative percentage of patients with undesirable or abnormal vales were statistically different for Lp[a] (29% versus 3%) and Hs-CRP (42% vs. 12%) (both P <0.001). CONCLUSIONS: If further studies will strengthen these preliminary findings, owing to the growing evidence that Lp[a] might act in synergy with other defined prothrombotic conditions in the pathogenesis of a variety of vascular disorders, we hypothesize that Lp[a] measurement might be useful in SSc to identify and eventually treat subsets of patients more predisposed to develop thrombotic complications.

C-Reactive Protein↗

Stability of blood cell counts, hematologic parameters and reticulocytes indexes on the Advia A120 hematologic analyzer.

Delayed sample analysis is not a rare circumstance in clinical and laboratory practice, especially when blood samples are shipped to distant centralized laboratories, when the analysis can not be readily performed, or when retesting is appropriate. In this study we sought to evaluate the stability of conventional and new hematologic parameters in blood specimens stored for as long as 24 hours at 4 degrees C. Of the 21 hematologic parameters tested with the use of the Advia 120 hematologic analyzer (Bayer Diagnostics), means for paired samples of specimens differed significantly over the 24-hour storage period for hematocrit, main corpuscular volume, percentage of macrocytes, platelet count, main platelet volume, reticulocyte count and percentage, and reticulocyte hemoglobin content (all P < .01). We noted no significant changes in the other parameters tested or in the white blood cell differential. The overall distribution of the immature reticulocytes fractions remained substantially unchanged, though the high staining-intensity fraction showed a considerable shift from the baseline measure. Bland-Altman plots and limits-of-agreement analysis showed mean biases between -4.8% and 37.2% and relative coefficients of variations ranging from 0.4% to 32.7%. The 95% agreement interval in the set of differences was satisfactory and almost within the current analytic-quality specifications for desirable bias. The results of this investigation suggest that, within certain limitations for parameters derived or calculated from cellular volumes, blood specimens stored for as long as 24 hours at 4 degrees C may be suitable for hematologic testing.

Automation↗

Serum ferritin as a marker of potential biochemical iron overload in athletes.

OBJECTIVES: Beyond hematological manipulation, iron supplementation therapy is commonplace in athletes to counterbalance physiological or pathologic anemia and to prevent physiologic dysfunction. However, misuse of iron therapy, occasionally resulting in iron overload, is not free from metabolic risks. DESIGN: We planned to measure baseline serum ferritin concentration in sedentary individual and athletes. SETTING: The Institute of Clinical Biochemistry of the Verona University. PARTICIPANTS Serum ferritin was measured in 60 male healthy sedentary controls, 80 amateur road cyclists, 42 male professional cross-country skiers, and 88 professional male road cyclists. ASSESSMENT OF RISK FACTORS: The biochemical iron overload was ascertained by measuring baseline serum ferritin concentration as a reliable approach that mirrors the total body iron content. MAIN OUTCOME MEASUREMENTS: The concentration of serum ferritin in healthy controls was 112 +/- 78 ng/mL, whereas that of amateur cyclists, professional skiers, and professional cyclists was 127 +/- 76 ng/mL (P = 0.185), 183 +/- 130 ng/mL (P = 0.001), and 332 +/- 218 ng/mL (P < 0.001), respectively. RESULTS: Both categories of professional athletes showed significantly increased concentrations of serum ferritin, whereas the concentration of amateur cyclists was comparable to that of healthy sedentary controls. CONCLUSIONS: Professional endurance athletes have serum ferritin concentrations that are 2-fold to 3-fold higher than those of matched sedentary individuals and amateur athletes, exceeding the threshold for the diagnosis of biochemical iron overload and unveiling potential metabolic risks.

Bicycling↗

Short-term venous stasis influences routine coagulation testing.

Preanalytical variability is a common source of errors in coagulation testing, as clotting assays are particularly susceptible to poor standardization of the whole analytical process. To investigate the effect of a short-term venous stasis on routine coagulation testing, we measured activated partial thromboplastin time, prothrombin time, fibrinogen and D-dimer in plasma specimens collected either without venous stasis or following the application of a 60 mmHg constant, standardized external pressure by a sphygmomanometer, for 1 (1-min stasis) and 3 min (3-min stasis). When compared with blood specimens collected without stasis, the Pearson's correlation coefficients and the corresponding slopes of the Passing and Bablok regression line of samples collected following 1 and 3-min stasis were acceptable. However, statistically significant differences by paired Student's t-test could be observed for all parameters tests following 3-min stasis, and for all but the activated partial thromboplastin time after 1-min stasis. Significant difference between specimens collected after 1- and 3-min stasis was also achieved for prothrombin time (P < 0.01), fibrinogen (P < 0.01) and D-dimer (P < 0.05). The agreement between measurements was yet acceptable after 1-min stasis, but achieved clinical significance for prothrombin time, fibrinogen and D-dimer after 3-min stasis. Taken together, results of the present investigation confirm that the effects of venous stasis during venipuncture are clinically meaningful. As hematocrit values and activities of clotting factors VII, VIII and XII significantly increased, whereas that of activated factor VII remained unchanged, we hypothesize that a short-term venous stasis, as induced by up to 3-min tourniquet placing, might not be sufficient to produce additional procoagulant responses besides hemoconcentration.

Blood Coagulation Factors↗