Search PubMed⌕ Search

Biomedical subjects

Giuseppe Boriani

Publications and source records attributed to Giuseppe Boriani.

At least 19 recordsLinked to original sources

Neurohormones and inflammatory mediators in patients with heart failure undergoing cardiac resynchronization therapy: time courses and prediction of response.

Despite interest in neurohormonal activation as a determinant of prognosis in chronic heart failure (CHF) and as a target for pharmacological treatments, data are lacking on the time-related effects of electrical cardiac resynchronization therapy (CRT) on a broad spectrum of neurohormones and cytokines. The aim of this study was to assess time-courses and extents of changes within the neurohormonal profile of CHF patients treated with CRT. We performed a prospective follow-up study in 32 patients with NYHA class III-IV CHF to investigate the effects of CRT on a broad panel of neurohormones proposed for characterization of CHF patients. Levels of atrial and brain natriuretic peptides (ANP, BNP), epinephrine, norepinephrine, aldosterone, plasma renin activity, IL-6, TNF, soluble receptors sTNFR1 and 2, and chromogranin A were assessed before implantation and after 3 months of CRT; when feasible, measurements were also performed at 1 week, 1 month and 12 months (clinical evaluation, echocardiography and ECG were also performed at each time-point). The results showed that at 3 months improvement in NYHA class and echographically assessed left ventricular (LV) reverse structural remodeling were accompanied by significant reductions versus baseline in ANP and BNP, but not in other neurohormones. Moreover a baseline ANP concentration < or = 150 pg/ml was a good predictor of response to CRT in terms of NYHA class reduction and reverse LV remodeling. In conclusion 3 months of CRT significantly reduce natriuretic peptides concentrations, while values of other neurohormones and inflammatory cytokines are relatively unvaried. A baseline ANP concentration < or = 150 pg/ml might be a clinically useful predictor of medium-term response to CRT.

Aged↗

Role of ventricular Autocapture function in increasing longevity of DDDR pacemakers: a prospective study.

AIMS: Autocapture is an algorithm for automatic adaptation of ventricular output to capture threshold. The aim of this prospective study was to estimate the effects of ventricular Autocapture algorithm on DDD-DDDR pacemaker longevity. METHODS AND RESULTS: Eighty-three patients implanted with a DDD-DDDR pacemaker (Affinity or Entity; St Jude Medical, USA) were enrolled and the Autocapture function was activated pre-discharge. Ventricular pulse duration was randomly programmed at 0.3 or 0.4 ms, with a cross-over at 8-12 weeks and again at 13-14 months. Diagnostic data were retrieved from device memory and by calculating battery current drain from long-term threshold recordings; device longevity was estimated at the following settings: Autocapture with a pulse duration of 0.3 and 0.4 ms, respectively, standard output (3.5 V, 0.4 ms) and conventional low output programming (2.5 V, 0.4 ms). According to a series of assumptions, Autocapture was associated with a 55-60% increase in estimated device longevity compared with standard output programming and a 6-7% increase in longevity compared with low output programming. No significant differences were found between Autocapture programmed with a pulse duration of 0.3 or 0.4 ms. In projections to a 10-year follow-up, use of the Autocapture function resulted in a 42% reduction in pacing-related estimated costs compared with standard output programming at 3.5 V, 0.4 ms. CONCLUSION: Pacing with constant adaptation of ventricular output in dual-chamber devices has the potential to increase generator longevity and to reduce sizeably pacing-related costs compared with standard programming.

Adult↗

Randomized comparison of simultaneous biventricular stimulation versus optimized interventricular delay in cardiac resynchronization therapy. The Resynchronization for the HemodYnamic Treatment for Heart Failure Management II implantable cardioverter defibrillator (RHYTHM II ICD) study.

BACKGROUND: The clinical value of interventricular (V-V) delay optimization in patients with chronic congestive heart failure (CHF) undergoing implantation of a device for cardiac resynchronization therapy (CRT) has not been clearly demonstrated. METHODS: RHYTHM II was a single-blind randomized trial including 121 recipients of a device for CRT with cardioverter/defibrillator capabilities (CRT-D) randomly assigned in a 1:3 ratio to simultaneous (n = 30) versus optimized (OPT) (n = 91) biventricular pacing. V-V delay was optimized by echocardiography. The study end points were (1) freedom from CRT-D system-related complications and (2) changes between preimplant and 6 months of follow-up in (a) New York Heart Association CHF functional class, (b) distance covered during a 6-minute hall walk, and (c) quality of life (QOL). RESULTS: In the OPT group, the V-V delay ranged from 0 to 80 milliseconds, with 28.4% of patients stimulated at an OPT V-V delay of 0 milliseconds. The overall 6-month survival free of adverse events requiring invasive interventions was 81.8%. In the whole cohort, 6 months of CRT-D was associated with a significant decrease in New York Heart Association class, increase in the distance covered during the 6-minute hall walk, and improvement in QOL (each P < .0001). The effects of CRT-D on these end points were similar in both study groups. CONCLUSIONS: Cardioverter-defibrillator capabilities was associated with a significant alleviation of CHF symptoms, increase in functional capacity, and improvement in QOL. The optimization of the V-V delay conferred no additional benefit compared with simultaneous biventricular stimulation.

Aged↗

Characteristics of ventricular tachyarrhythmias occurring in ischemic versus nonischemic patients implanted with a biventricular cardioverter-defibrillator for primary or secondary prevention of sudden death.

OBJECTIVES: The InSync ICD Registry evaluated patients indicated for cardiac resynchronization therapy with defibrillation. BACKGROUND: Cardiac resynchronization therapy with defibrillation systems are prescribed for both primary and secondary prevention of sudden cardiac death in patients with heart failure with both ischemic and nonischemic etiology. The characterization of ventricular tachyarrhythmias detected by the ICD is not well known in these subpopulations. METHODS: We enrolled 421 patients with symptomatic heart failure despite optimized medical treatment, ventricular dyssynchrony, and primary or secondary ICD indications. An electrophysiologist reviewed all spontaneous episodes. Patients were grouped by etiology and ICD indications. RESULTS: The 421 patients included 292 ischemic (159 primary prevention) and 129 nonischemic (68 primary prevention) patients. In 19 +/- 11 months of follow-up, 110 patients (63 ischemic, 30 primary prevention and 47 nonischemic, 21 primary prevention) presented ventricular tachyarrhythmias, occurring in a ventricular tachycardia (VT) or a ventricular fibrillation zone (1382 and 456 events, respectively). The incidence of overall ventricular tachyarrhythmias in nonischemic patients in secondary prevention (35.7% at 1 year) was higher than in ischemic patients implanted for either indication (16.5% and 22.9% at 1 year, respectively). The incidence of self-terminating ventricular tachyarrhythmias was greater in patients with nonischemic heart disease, regardless of indication. Patients with ischemic heart disease in primary prevention had a lower occurrence of VTs, whereas nonischemic patients in primary prevention had faster VTs. CONCLUSIONS: Both rate of occurrence and characteristics of detected ventricular tachyarrhythmias vary according to underlying etiology and indication. Therefore, different device programming according to patient's profile is advisable to improve ventricular tachyarrhythmias management.

Adult↗

Biventricular vs. left univentricular pacing in heart failure: rationale, design, and endpoints of the B-LEFT HF study.

AIMS: Cardiac resynchronization therapy (CRT) confers sustained therapeutic benefits to patients suffering from congestive heart failure (CHF) due to systolic dysfunction associated with ventricular dyssynchrony. Biventricular (BiV) pacing has, thus far, been the preferred method, as it corrects both electrical and mechanical dyssynchrony. Left ventricular (LV) only pacing, which has conferred similar benefits in pilot studies, may be an alternative treatment method. 'Biventricular vs. left univentricular pacing with ICD back-up in heart failure patients' (B-LEFT HF) is an international, prospective, randomized, parallel-design, double-blind, clinical trial to examine whether LV only pacing is as safe and effective as BiV pacing in patients suffering from CHF. METHODS AND RESULTS: The trial will randomly assign 172 patients to either LV only or BiV pacing. The study has prospectively defined efficacy endpoints to be evaluated at 6 months, which are (i) changes in functional capacity and degree of reverse remodelling (primary) and (ii) changes in the heart failure clinical composite response (secondary). CONCLUSION: Because LV only pacing in CRT is likely to be technically less challenging and costly than BiV, a specifically designed study is needed to compare the safety and effectiveness of the two configurations. B-LEFT HF has been designed to settle this critical issue.

Adult↗

Randomized comparison between Ramp and Burst+ atrial antitachycardia pacing therapies in patients suffering from sinus node disease and atrial fibrillation and implanted with a DDDRP device.

AIMS: Atrial tachycardia and flutter frequently occur in association with atrial fibrillation and may be treated by overdrive pacing in patients who receive pacemakers with antitachycardia pacing (ATP) capabilities. The PITAGORA trial was a multi-centre, randomized, cross-over study aimed at comparing two different ATP modes for atrial tachyarrhythmia (AT) termination in patients suffering from sinus node disease (SND). METHODS AND RESULTS: One hundred and seventy-six patients (72 M, age 71+/-9 years) received a Medtronic AT500 pacemaker. All patients were on class IC or III antiarrhythmic drugs. After a 5-month observation period, 170 patients were randomized to either Ramp or Burst+ ATP therapy; 4 months later they crossed over. One hundred and fifty-seven patients completed the 13 months of follow-up; 114 (72.6%) suffered 6088 AT episodes. In 75 patients, 1904 AT episodes were treated and 934 (49.1%) successfully terminated. The median value of individual patients' ATP efficacy was 60%. Burst+ terminated 387 out of 873 AT episodes (44%) in 58 patients. Ramp terminated 547 out of 1031 AT episodes (53%, P<0.001) in 56 patients. Ramp efficacy was significantly (P<0.01) and directly correlated with AT cycle length (ATCL), whereas Burst+ efficacy was not. Ramp showed higher (P<0.001) termination efficacy than Burst+ for ATCL >240 ms. Quality of life, as measured by the EuroQoL questionnaire, and number of symptoms significantly improved in the overall population. This improvement was significantly higher in patients with ATP efficacy >60%. CONCLUSION: In patients suffering from SND and AT, Ramp therapy shows higher termination efficacy than Burst+ therapy in AT episodes with ATCL >240 ms. Further studies are required to show the impact of ATP on clinical outcomes.

Aged↗

Reducing unnecessary right ventricular pacing with the managed ventricular pacing mode in patients with sinus node disease and AV block.

BACKGROUND: Frequent and unnecessary right ventricular apical pacing increases the risk of atrial fibrillation or congestive heart failure. We evaluated a new pacing algorithm, managed ventricular pacing (MVP) which automatically changes modes between AAI/R and DDD/R in patients receiving pacemakers for symptomatic bradycardia. METHODS: Patients were randomized to the MVP mode or DDD/R mode for 1 month and then crossed over to the alternate pacing modality for an additional month. On completion of the crossover phase, the pacing mode selected was individualized and patients were followed for an additional 4 months. RESULTS: Of the 129 patients who successfully completed the crossover study, the cumulative percent ventricular pacing was significantly reduced in the MVP mode (median 1.4%) compared to the DDD/R mode (median 89.6%, 94.0% relative reduction; 95% CI 89.3-98.8%, P < 0.001). Patients with sinus node disease (SND, n = 51) when compared to patients with AV block (AVB) (n = 68) experienced a greater reduction in ventricular pacing with the MVP mode compared to the DDD/R mode (median relative reduction 99.1%; 95% CI 97.5-99.9% vs median relative reduction 60.1%; 95% CI 16.7-93.9% P < 0.001). The reduced percent ventricular pacing during MVP was sustained over longer term follow-up. CONCLUSIONS: The majority of patients with a bradycardia indication for cardiac pacing do not require ventricular pacing most of the time. The MVP mode significantly reduces unnecessary right ventricular pacing. This mode benefits even patients with intermittent AVB and is sustained over longer term follow-up.

Aged↗

Optimization of pacing algorithms to prevent and treat supraventricular tachyarrhythmias.

Preventive atrial pacing and antitachycardia pacing have been proposed for the treatment of atrial fibrillation and associated arrhythmias in patients with indications for device implantation. Preventive algorithms provide overdrive atrial pacing, reduction of atrial premature beats, and prevent short-long atrial cycles with good patient tolerance. However, clinical trials testing preventive algorithms have shown contradictory results, possibly because of different trial designs, end points and patient populations. Factors probably responsible for neutral results include an already high atrial pacing percentage with the conventional DDDR mode, suboptimal atrial pacing site, and the deleterious effects of high percentages of right ventricular apical pacing. Atrial antitachycardia pacing therapies are effective in treating organized atrial tachyarrhythmias (that precede atrial fibrillation), mainly when delivered early after the onset particularly if the tachycardia is relatively slow. Antitachycardia pacing therapies might influence atrial fibrillation burden, but clinical studies have shown conflicting results about this issue. Consistent monitoring of atrial and ventricular rhythm including progression to persistent forms of atrial arrhythmias, variability of atrial arrhythmia recurrence patterns and onset mechanisms as well as antitachycardia pacing efficacy should be recorded in the stored device memory and used for optimal individual programming of these new functions.

Algorithms↗

Primary prevention of sudden cardiac death: can we afford the cost of cardioverter-defibrillators? Data from the Search-MI Registry-Italian sub-study.

BACKGROUND: Large randomized trials show that in appropriately selected patients with left ventricular dysfunction, implantable cardioverter-defibrillators (ICDs) can improve overall survival at 2-5 years. Since direct implementation of the criteria used in the MADIT II and SCD-HeFT will lead to a marked rise in ICD implants, there is a growing fear that increased use of ICDs may cause a dramatic burden to health care systems. The ICD has traditionally been seen as an expensive form of treatment, which is difficult to accept at the first look. This is mainly due to the nonlinear character of the ICD investment, characterized by high initial expenditure, followed by a deferred pay-off in terms of clinical benefits. Cost-effectiveness analysis may help provide a different perspective on the problem of ICD cost, as may estimation of the daily cost of ICD treatment, assuming a time horizon of 5-7 years--a particularly interesting subject for further registry studies. METHODS AND RESULTS: Based on real expenditure data from 2002 to 2005, as recorded in the Search-MI Registry-Italian Sub-study of patients implanted on MADIT II indications, we estimated the daily costs associated with the device and leads. Over a 5-7 year time horizon, the average daily cost was estimated to be euro 4.60-euro 6.70. Translation of these figures into U.S. market conditions suggests a daily cost of around $7.90-$11.40. CONCLUSIONS: These findings appear useful to help evaluate the affordability of ICD in comparison with other therapeutic options in a context of limited available economic resources.

Aged↗

Role of severe functional mitral regurgitation in predicting electrical remodeling in idiopathic dilated cardiomyopathy.

OBJECTIVE: To investigate incidence and predictors of clinically relevant QRS widening (predefined as > or = 10% with respect to baseline) in idiopathic dilated cardiomyopathy (IDC) and particularly the prognostic role of functional mitral regurgitation (MR). Although QRS widening in left ventricular systolic dysfunction carries relevant prognostic and therapeutic implications, its incidence and predictors in patients with IDC remain unknown. METHODS: We analyzed 114 patients with IDC receiving optimized medical treatment (age 52 +/- 10 years; 44% males; 36% New York Heart Association class III-IV) who underwent clinical, echocardiographic, hemodynamic, and laboratory evaluations and at least two electrocardiograms > or = 6 months after the index evaluation. RESULTS: During follow-up (median 20 months), 19 (17%) patients developed clinically relevant QRS widening, corresponding to an incidence of 8% per year. At multivariable analysis, the presence of echocardiographically detected severe MR (P = 0.029) and mean right atrial pressure (RAP) by right heart catheterization (P = 0.021) independently predicted clinically relevant QRS widening. CONCLUSIONS: Clinically relevant QRS widening is relatively frequent in IDC despite optimized medical treatment, and is independently predicted by MR severity and high RAP. IDC patients presenting either of these risk-factors might benefit from strict follow-up, which could also allow timely detection of the onset of indications for cardiac resynchronization therapy.

Adult↗

Monitored atrial fibrillation duration predicts arterial embolic events in patients suffering from bradycardia and atrial fibrillation implanted with antitachycardia pacemakers.

OBJECTIVES: The aim of our study was to evaluate arterial embolism (AE) occurrence rates and predictors in patients suffering from bradycardia and wearing a pacemaker with antitachycardia pacing therapies. BACKGROUND: Atrial fibrillation (AF) is associated with a high incidence of AE. METHODS: A total of 725 patients (360 men, age 71 +/- 11 years) were implanted with a DDDRP pacemaker (Medtronic AT500, Medtronic Inc., Minneapolis, Minnesota). At baseline 225 (31.0%) patients received antiplatelet therapy and 264 (36.4%) patients received anticoagulation agents. RESULTS: Over a median 22-month follow-up (25th to 75th interquartile range 16 to 30 months), AE occurred in 14 (1.9%) patients: 7 patients suffered a nonfatal ischemic stroke (0.6% per year), 4 patients had transient ischemic attack (0.34% per year), and 3 patients had embolic complications. Among baseline patients' characteristics, multivariate logistic analysis showed that embolic events are independently associated to ischemic heart disease (7.0 odds ratio [OR], 95% confidence interval [CI] 2.3 to 21.3, p = 0.001), prior embolic event (7.3 OR, 95% CI 1.2 to 43.9, p = 0.029), diabetes (5.0 OR, 95% CI 1.2 to 15.7, p = 0.032), and hypertension (4.1 OR, 95% CI 1.1 to 15.6, p = 0.036). The risk of embolism, adjusted for known risk factors, was 3.1 times increased (95% CI 1.1 to 10.5, p = 0.044) in patients with device-detected atrial fibrillation episodes longer than one day during follow-up. CONCLUSIONS: In a cohort of patients with bradycardia and AF, arterial embolism was common in patients with ischemic cardiopathy, hypertension, diabetes mellitus, and in patients with known stroke risk factors. Atrial fibrillation occurrences longer than one day were independently associated with embolic events.

Aged↗

Heart failure after myocardial revascularization: risk markers.

We investigated the prognostic weight of several risk factors for heart failure in patients undergoing CABG. We followed 351 consecutive patients for 18+/-12 months after surgery to assess clinical outcome, presence and degree of heart failure. The risk of developing heart failure >class 2 at 1 year was investigated by logistic regression on the following preoperative variables: sex, age, left ventricular EF, QRS duration, previous MI, history of heart failure, atrial fibrillation (AF), hypertension, hypercholesterolemia, diabetes, previous stroke. Age was 70+/-8 years and EF was 54+/-12% at the time of surgery. Heart failure >class 2 occurred in 95/351 patients (27%) at follow up. Logistic regression identified QRS duration (OR=1.02), a history of stroke (OR=3.94), and diabetes (OR=1.98) as predictors of CHF at follow up. All the other variables were not risk markers for heart failure at logistic regression. Thirty five patients (10%) had QRS> or =140 ms before surgery; 51% of them had CHF at follow up compared to 24% of patients with QRS<140 ms (p<0.05). In the current surgical era, candidates to CABG (50% of patients older than 70 years) have a relevant likelihood of heart failure at follow up, despite myocardial revascularization. Risk stratification may rely upon inexpensive variables as previous stroke, diabetes, and QRS duration. A minority of patients (5%) could benefit from LV-based pacing, which should be considered at the same surgical time via an epicardial implantation.

Adult↗

Acute and chronic haemodynamic effects of biventricular pacing and of switching to different pacing modalities in heart failure patients.

BACKGROUND: In patients with severe heart failure, sinus rhythm and wide QRS complex biventricular (BiV) pacing leads to clinical and haemodynamic improvement, but the immediate reversibility of these changes is not known. METHODS: We assessed the acute and medium-term (3-month) haemodynamic effects of BiV pacing and of switching to other pacing modalities in 21 patients with severe heart failure, sinus rhythm and QRS>or=130 ms. Haemodynamic studies were performed: 1) at the time of implantation of a BiV pacing device, during AAI pacing, atrial synchronous right ventricular (RV) pacing, atrial synchronous left ventricular (LV) pacing and atrial synchronous BiV pacing (all at 100 bpm); 2) after 3 months of continuous BiV pacing--with evaluations being made by switching to RV and the other pacing modalities. RESULTS: At both the acute and medium-term evaluations, BiV pacing provided the greatest improvement in cardiac index. Switching from BiV to RV pacing led to a more marked decrease in the cardiac index at 3 months. No strict correlation was evident between acute and medium-term effects of BiV pacing on cardiac index. CONCLUSION: Cardiac resynchronization by BiV pacing provides acute/medium-term improvements in cardiac index. Sudden, medium-term failure of LV stimulation can lead to an even more pronounced haemodynamic derangement than that inducible by RV pacing at baseline. Acute haemodynamic evaluations do not seem to provide a powerful way for identifying medium-term responders.

Acute Disease↗

Dilated-hypokinetic evolution of hypertrophic cardiomyopathy: prevalence, incidence, risk factors, and prognostic implications in pediatric and adult patients.

OBJECTIVES: This study sought to investigate the incidence, risk factors, and prognosis of dilated-hypokinetic evolution in a large cohort of patients with hypertrophic cardiomyopathy (HCM) followed up at a cardiology center serving both the pediatric and the adult population. BACKGROUND: The available data on this evolution of HCM mainly regards prevalence (rather than incidence) in adults, with very little being known about the pediatric population. METHODS: A total of 222 consecutive HCM patients (65% men, 19% < or =18 years old) were prospectively evaluated for a mean follow-up of 11 +/- 9 years. RESULTS: A diagnosis of dilated-hypokinetic HCM was made in 12 patients at first evaluation (11 without previous septal myectomy surgery; prevalence, 4.9%). Twelve of the 210 patients with classic HCM at first evaluation underwent dilated-hypokinetic evolution (incidence, 5.3/1,000 patient-years). Patients with prevalent/incident dilated-hypokinetic evolution were younger at first evaluation (32 +/- 14 years vs. 41 +/- 21 years, p = 0.04) and more often had a family history of HCM (61% vs. 26%, p = 0.002) or sudden death (43% vs. 19%, p = 0.01) with respect to patients who maintained classic HCM. Moreover, they showed greater interventricular septum (23 +/- 3 mm vs. 19 +/- 6 mm, p = 0.004) and posterior wall (15 +/- 3 mm vs. 13 +/- 4 mm, p = 0.006) thickness. Cardiovascular death-free survival was lower among patients with dilated-hypokinetic HCM (p < 0.04). Cox proportional hazards regression analysis identified left ventricular wall thickness (hazard ratio [HR] = 1.07; 95% confidence interval [CI], 1.01 to 1.14; p = 0.03) and end-diastolic diameter (HR = 1.08; 95% CI 1.04 to 1.11; p = 0.0001) as independent predictors of cardiovascular death. CONCLUSIONS: Dilated-hypokinetic evolution is rare but not exceptional in HCM. Young age at diagnosis, family history of HCM, and greater wall thickness are incremental risk factors for dilated-hypokinetic HCM, which carries an ominous prognosis.

Adolescent↗

A controlled study on the effect of verapamil on atrial tachycaarrhythmias in patients with brady-tachy syndrome implanted with a DDDR pacemaker.

While verapamil has been proposed as a treatment for reducing electrophysiological remodeling due to atrial fibrillation and atrial tachyarrhythmias, no previous study has tested its effects in brady-tachy patients implanted with a dual-chamber pacemaker. Fourteen patients with frequent episodes of atrial fibrillation (> or =2 episodes/month) in the setting of brady-tachy syndrome, implanted with a DDDR pacing system with extensive monitor function (Selection 900, Vitatron) were enrolled. Four months after implantation, they were randomly allocated to a 2-month period of treatment with verapamil (240 mg/day) or to no treatment, followed by a crossover. The burden of atrial tachyarrhythmias, the total number of hours spent in atrial tachyarrhythmia and the mean number of hours per day spent in atrial tachyarrhythmia were retrieved from diagnostic devices. The accuracy of atrial tachyarrhythmias detection was confirmed independently by two observers. The main results showed that treatment with verapamil was associated with a trend towards an higher percentage of atrial pacing in comparison with control (mean value+/-S.D.=63.2+/-29.9% vs. 57.3+/-30.6%, median value 53% vs. 49%, P value at Wilcoxon signed rank test=0.069), but without any significant reduction in atrial tachyarrhythmia burden (4.5+/-11.8 vs. 3.3+/-9.1%) or total hours spent in atrial tachyarrhythmia (65+/-161 vs. 48+/-131 h). Palpitation episodes were not significantly reduced by verapamil treatment in comparison with control (10.3+/-7.8 vs. 6.1+/-6.5). In conclusion, verapamil does not exert any beneficial effect on documented episodes of atrial tachyarrhythmia in patients with brady-tachy syndrome implanted with a DDDR device. Moreover, this drug was ineffective in reducing the number of palpitation episodes reported by the patient.

Aged↗

P wave dispersion and short-term vs. late atrial fibrillation recurrences after cardioversion.

BACKGROUND: P wave dispersion has been previously suggested as a potential tool for predicting the risk of recurrence of atrial fibrillation after electrical cardioversion. We investigated whether different P wave dispersion values are associated with recurrence of atrial fibrillation in the short (< or =1 month after cardioversion) and longer term. METHODS: In 37 patients with long-lasting persistent atrial fibrillation (mean duration 21 +/- 36 months) with (n = 19) or without (n = 18) amiodarone pretreatment as antiarrhythmic prophylaxis, maximum and minimum P wave duration and P wave dispersion were measured 1 min after internal cardioversion. RESULTS: P wave dispersion was lower in patients with amiodarone pretreatment (28.3 +/- 9.5 vs. 21.9 +/- 7.3 ms, P = 0.029). The subgroups of patients with recurrence of atrial fibrillation at 1 month or in the long-term did not differ from the rest of the study sample regarding age, sex, atrial fibrillation duration, left atrial dimensions or ejection fraction. P wave dispersion was significantly higher in patients with short-term atrial fibrillation recurrence (< or = 1 month) than in the rest of the population. Furthermore, P wave dispersion values >25 ms were associated with a higher short-term relapse rate. No significant relation was present in the long-term. CONCLUSIONS: Our results suggest that P wave dispersion analysis immediately after internal cardioversion may help predict short-term recurrences of atrial fibrillation. These findings may be related to different mechanisms and predisposing factors for short-term and late recurrences. The long-term predictive value of serial evaluations of P wave dispersion during follow-up deserves investigation.

Aged↗