Search PubMed⌕ Search

Biomedical subjects

Giovanni Simonetti

Publications and source records attributed to Giovanni Simonetti.

At least 19 recordsLinked to original sources

Single-photon emission computed tomography/computed tomography in abdominal diseases.

Single-photon emission computed tomography (SPECT) studies of the abdominal region are established in conventional nuclear medicine because of their easy and large availability, even in the most peripheral hospitals. It is well known that SPECT imaging demonstrates function, rather than anatomy. It is useful in the diagnosis of various disorders because of its ability to detect changes caused by disease before identifiable anatomic correlates and clinical manifestations exist. However, SPECT data frequently need anatomic landmarks to precisely depict the site of a focus of abnormal tracer uptake and the structures containing normal activity; the fusion with morphological studies can furnish an anatomical map to scintigraphic findings. In the past, software-based fusion of independently performed SPECT and CT or magnetic resonance images have been demonstrated to be time consuming and not useful for routine clinical employment. The recent development of dual-modality integrated imaging systems, which provide SPECT and CT images in the same scanning session, with the acquired images co-registered by means of the hardware, has created a new scenario. The first data have been mainly reported in oncology patients and indicate that SPECT/CT is very useful because it is able to provide further information of clinical value in several cases. In SPECT studies of abdominal diseases, hybrid SPECT/CT can play a role in the differential diagnosis of hepatic hemangiomas located near vascular structures, in precisely detecting and localizing active splenic tissue caused by splenosis in splenectomy patients, in providing important information for therapy optimization in patients submitted to hepatic arterial perfusion scintigraphy, in accurately identifying the involved bowel segments in patients with inflammatory bowel diseases, and in correctly localizing the bleeding sites in patients with gastrointestinal bleeding.

Abdomen↗

Whole body 16-row multislice CT in emergency room: effects of different protocols on scanning time, image quality and radiation exposure.

The objective of this study was to compare two different scanning protocols in patients suspected to have multiple trauma using multidetector 16-row computed tomography (CT) to better define scanning time, imaging quality and radiation exposure. Forty-six patients, between March 2004 and March 2005, with suspected multiple trauma (cerebral, spine, chest, abdominal and pelvis) were evaluated with two different protocols: Protocol "A" 26 patients; Protocol "B" 20 patients. Protocol A consists of a single-pass continuous whole-body acquisition (from vertex to pubic symphysis), whereas Protocol B of conventional segmented acquisition with scanning of body segments individually. Both protocols were performed using a multidetector 16-rows CT (Light-Speed 16, General Electric Medical System, Milwaukee, WI, USA) with the same technical factors. Radiation dose was evaluated in two ways: computer tomography dose index (CTDI) = dose measured in central and peripheral region of the subjects as a direct result of a CT section acquisition of T millimeters thick (independent from the two protocols) and dose length product (DLP) = total dose deposited over the length of the acquisition (dependent from the two protocols). Image quality was rated according to the following scores: 1, excellent; 2, good; 3, satisfactory; 4, moderate and 5, poor. The results were compared using Wilcoxon's test to identify significant difference in terms of image quality, scanning time, radiation exposure and presence of artifacts, assuming significance at a p value of <0.05. In the single-pass scanning, DLP was 2.671 mGy x cm and a total scan time of 35 s. In whole-body protocols, we have seen artifacts due to arm adduction in thorax and less image quality in brain. In the conventional segmented study, DLP was 3.217 mGy x cm and a total scan time of 65 s; this protocol offered less extraction capabilities of off-axial on focused images of the entire spine, aorta, facial bones or hip without rescanning. Protocol A revealed a significant decrease in scan time (35 vs 65 min, p < 0.05), time in the CT examination room (21.7 vs 31.6 min.; p < 0.05), and final image analysis (83.7 vs 102.9 min; p < 0.05) and radiation dose compared to protocol B (p < 0.05). No significant difference was found for patient transport time, image reconstruction time and imaging quality. Reconstruction and isotropic reformation of axial image acquired by whole-body, single-pass protocols due to entire spine evaluation, aortic and splanchnic CT angiography eliminate additional studies. The whole-body, single-pass protocols, compared with segmented acquisitions protocols, resulted in a reduced total radiation dose without relevant loss of diagnostic image information.

Adolescent↗

Sacroplasty and iliac osteoplasty under combined CT and fluoroscopic guidance.

STUDY DESIGN: We postulate that osteoplasty of osteolytic metastases of the pelvic region performed by computed tomography (CT)-guided insertion of Kirschner wires into the lesions is effective and more feasible. OBJECTIVE: To determine whether osteoplasty of osteolytic metastases of the pelvic region can be performed by a more feasible lesion access, increasing patient compliance and reducing patient radiation exposure. SUMMARY OF BACKGROUND DATA: Treatment of osteolytic bone metastases is palliative and relies mainly on the elimination of pain. When pain is medically intractable, this can be effectively treated by osteoplasty. MATERIALS AND METHODS: A 61-year-old man with medically intractable pain from osteolytic lesions of the sacral ala and left iliac alum from pulmonary adenocarcinoma underwent osteoplasty. The lesions were accessed using Kirschner wires under CT guidance. Subsequently, under high-resolution fluoroscopic guidance, 13-G biopsy needles were advanced coaxially over the Kirschner wires and polymethyl methacrylate (PMMA) was injected into the lesions. RESULTS: No peri-procedural complications were observed. The patient experienced an immediate and substantial pain relief that was persistent during a 4-month follow-up. CONCLUSIONS: This technique is safe and effective and requires fewer CT scans, thus reducing the patient's radiation exposure. The shorter procedure correlates to a better patient tolerance.

Adenocarcinoma↗

Transjugular intrahepatic portosystemic shunt patency and clinical outcome in patients with Budd-Chiari syndrome: covered versus uncovered stents.

PURPOSE: To retrospectively compare primary patency and reintervention rates, clinical outcome, and improvement in hepatic dysfunction (Child-Pugh score) in patients with Budd-Chiari syndrome treated with transjugular intrahepatic portosystemic shunt (TIPS) using bare stents or expanded polytetrafluoroethylene (PTFE)-covered stents. MATERIALS AND METHODS: Approval of study and treatment protocol and waiver of informed consent for the retrospective study were obtained from institutional review board. Informed consent was obtained from each patient before procedure. Four male and nine female consecutive patients (mean age, 35.7 years) with Budd-Chiari syndrome treated with TIPS from January 1994 to November 2003 were included. In six patients, TIPS creation was performed with bare stents (group A). After April 2001, TIPS creation was performed in seven patients with expanded PTFE-covered stent-grafts (group B). Follow-up (group A mean, 22.7 months +/- 10.53 [standard deviation]; group B mean, 23.1 months +/- 7.81) was performed at 7 days, 30 days, and 3 months and subsequently every 3 months. Liver function was evaluated every 3 months. Primary end points were 6- and 12-month TIPS patency rates. Secondary end points were reintervention rate and clinical outcome. Patency rates were estimated (Kaplan-Meier method) and compared (log-rank test). Continuous (Mann-Whitney U test) and categoric (chi(2) test) data were compared. Significant differences before and after treatment were determined (Wilcoxon test). RESULTS: Mean primary patency duration was 4.46 months +/- 3.40 in group A and 22.29 months +/- 8.15 in group B. In group B, a significant increase in primary patency rate (100% and 85.7% vs 16.7% and 0% at 6 and 12 months; P < .001, log-rank test) and a decrease in reintervention rate (0.29 +/- 0.49 vs 6.17 +/- 1.72, P < .001) were observed. Both groups had a significantly decreased Child-Pugh score; group B had a more persistent and significantly higher reduction. CONCLUSION: Expanded PTFE-covered stent-grafts significantly increased primary patency rate of TIPS in patients with Budd-Chiari syndrome, with reduced reintervention rate and prolonged clinical improvement.

Adolescent↗

Usefulness of lung perfusion scintigraphy before lung cancer resection in patients with ventilatory obstruction.

BACKGROUND: The study was conducted to evaluate the efficacy of preoperative lung perfusion scintigraphy performed by planar acquisition and single-photon emission computed tomography (SPECT) in predicting postoperative pulmonary function of patients with resectable lung cancer and obstructive ventilatory defect. METHODS: The study enrolled 39 patients (mean age, 67 +/- 2.1 years). All patients underwent preoperative and postoperative pulmonary function tests. Cut-off values for postoperative forced expiratory volume in 1 second (FEV1) were 65% of the predicted value for pneumonectomy and 45% for lobectomy. A semiquantitative analysis of planar and SPECT lung perfusion scintigraphy images was performed preoperatively to estimate postoperative predicted FEV1 (FEV1ppo). Relationships between FEV1ppo and measured postoperative FEV1 were tested by the Pearson correlation and Bland Altman agreement tests. RESULTS: Twenty-eight lobectomies and 11 pneumonectomies were performed. The FEV1ppo estimated by mean planar lung scintigraphy was 1.85 +/- 0.38 L, with a Pearson correlation coefficient to the measured FEV1 of 0.8632 (p < 0.001). The mean FEV1ppo estimated by SPECT was 1.78 +/- 0.31 L, with a Pearson coefficient to the measured FEV1 of 0.8527 (p < 0.001). Both values showed a more significant correlation with postoperative measured FEV1 after lobectomy (p < 0.001) than after pneumonectomy (p = 0.045). The Bland Altman test confirmed satisfactory agreement of FEV1ppo estimated by both planar lung scintigraphy and SPECT with FEV1 measured by spirometry. CONCLUSIONS: Both planar lung scintigraphy and SPECT can accurately predict postoperative FEV1 and can therefore be considered reliable tools in establishing operability of patients with lung cancer and ventilatory obstruction.

Aged↗

Usefulness of SPECT/CT with a hybrid camera for the functional anatomical mapping of primary brain tumors by [Tc99m] tetrofosmin.

The aims of this study were to assess the clinical usefulness of [Tc-99m] tetrofosmin (TF) single photon emission computed tomography (SPECT) and X-ray transmission computed tomography (CT), performed simultaneously with a hybrid imaging device for the functional anatomical mapping of brain tumors and to evaluate the additional information of SPECT/CT when compared to SPECT alone. Thirty (30) patients were studied: 20 were evaluated before undergoing surgery and 10 after surgery and before radiotherapy planning. The acquisition of both functional (SPECT) and morphologic (CT) images were obtained in a single session. SPECT images were firstly evaluated alone and then reinterpreted by adding the anatomical (CT) planes. Fusion imaging was successfully obtained in all patients with precise correspondence between SPECT and CT slices. SPECT/CT had a significant clinical impact in 13 (43.3%) of 30 cases; in particular, SPECT/CT accurately characterized eight lesions near sites of physiological uptake (i.e., four near ventricles/choroids plexus, three near venous sinuses, one near the skull) and localized viable tumor tissue in 5 patients evaluated after surgery. SPECT/CT with TF using this hybrid device represents a useful clinical tool in brain tumor imaging, both correctly categorizing focal areas near sites of physiological uptake and localizing viable tumor tissue after surgery.

Adult↗

Carotid artery stenting with filter protection in high-risk patients showing severe electroencephalographic alterations during carotid endarterectomy.

PURPOSE: To describe the results and efficacy of stent treatment in patients with carotid stenosis who had aborted carotid endarterectomy procedures due to the appearance of severe electroencephalographic (EEG) alterations. METHODS: A retrospective study was conducted of 18 patients (11 men; mean age 72 years, range 62-84) with symptomatic high-grade carotid artery stenoses (> or = 70%) who experienced severe EEG alterations during carotid endarterectomy, causing the procedure to be aborted. Twelve patients had shown no hemodynamic alterations during preoperative transcranial Doppler evaluation after external compression of the common carotid artery; the remaining 6 could not be evaluated. The patients were referred for carotid artery stenting (CAS); 7 had contralateral internal carotid artery stenosis and 5 had contralateral occlusion. Endovascular intervention was carried out using standard techniques under filter protection. Follow-up was scheduled at 3, 6, and 12 months. RESULTS: All patients were successfully treated without immediate complications. The EEG did not display any significant alterations during the endovascular procedure. Mean follow-up was 43 months. Magnetic resonance imaging at 6 months showed no signs of cerebral ischemia. Color Doppler ultrasound imaging documented normal stent patency in all patients. CONCLUSION: Patients with symptomatic severe carotid stenosis (> or = 70%) who are considered at risk due to the appearance of severe EEG alterations during surgical treatment may benefit from CAS with respect to both major and minor complications. Larger studies are needed to confirm these findings.

Aged↗

Contrast-enhanced breast MRI in patients with suspicious microcalcifications on mammography: results of a multicenter trial.

OBJECTIVE: The objective of our study was to test dynamic MRI in evaluating mammographically detected suspicious microcalcifications. MATERIALS AND METHODS: One hundred twelve patients with mammographically detected microcalcifications with BI-RADS category 5 (n = 78) or 4 (n = 34) lesions were studied at 17 centers a using 3D gradient-echo dynamic coronal technique (< or = 3 mm thickness) and 0.1 mmol/kg of gadoteridol. A pathologic sample was obtained in all cases. Agreement between the major diameter measured on mammography, MRI, or both and the major diameter measured at pathologic examination was calculated in 62 cases. RESULTS: Of the 112 lesions, pathologic examination revealed 37 benign lesions, 33 ductal carcinoma in situ (DCIS), and 42 invasive carcinomas. The specificity of MRI for benign lesions was 68%. Considering the subgroups of calcifications alone and calcifications associated with masses, the specificity values became 79% and 33%, respectively. The sensitivity of MRI for DCIS was 79%. Analysis of the two subgroups showed sensitivity values of 68% for calcifications alone and of 1% for calcifications associated with masses. The sensitivity for invasive carcinomas was 93%. Analysis of the two subgroups showed sensitivity values to be 92% for calcifications alone and 94% for calcifications associated with masses. Considering the overall results, the sensitivity of MRI was 87%; specificity, 68%; positive predictive value, 84%; negative predictive value, 71%; and accuracy, 80%. Considering the subgroups of calcifications alone and calcifications associated with masses, the sensitivity values became 80% and 97%; the positive predictive values, 86% and 82%; the negative predictive values, 71% and 75% (95% confidence interval [CI], 0.19-0.99); and the accuracy values, 80% and 82% (95% CI, 0.66-0.92), respectively. An odds ratio (OR) of 13.54 (95% CI, 5.20-35.28) showed a raised risk of malignant breast tumor in subjects with positive MR examination of mammographically detected suspicious clusters of microcalcifications. The statistical analysis on each subgroup showed an OR of 15.07 (95% CI, 4.73-48.08) for calcifications alone and an OR of 14.00 (95% CI, 1.23-158.84) for calcifications associated with masses. Any significant improvement in the predictive ability of dynamic MRI depending on the extent of calcifications on mammography was not proved. Considering the 62 cases of proved malignancy with measured maximal diameter at pathologic examination, both mammography and MR examination seem to overestimate tumor extent. CONCLUSION: The not-perfect sensitivity of MRI (87%), when applying our interpretation criteria and imaging sequences, is a crucial point that prevents us from clinical use of MRI in the diagnosis of mammographically detected microcalcifications.

Adult↗

The effect of levodopa therapy on dopamine transporter SPECT imaging with( 123)I-FP-CIT in patients with Parkinson's disease.

PURPOSE: The aim of this study was to evaluate, by means of (123)I-FP-CIT SPECT, the effect of chronic treatment with levodopa on striatal dopamine transporter (DAT) in patients with Parkinson's disease. METHODS: Fifteen patients under stable levodopa/carbidopa monotherapy were imaged twice: at baseline on medication and after at least 20 days of treatment wash-out. DAT levels were assessed from SPECT imaging for the entire striatum, the right and left striatum, the right and left putamen and the right and left caudate, as a ratio of regional brain activities using the formula: (striatal region of interest-occipital)/occipital. RESULTS: During levodopa wash-out, despite a worsening in patients' clinical disability (H&Y mean stage 2.53+/-0.58 versus 1.73+/-0.45 on therapy, p<0.001), striatal( 123)I-FP-CIT levels were not significantly different from those at baseline in any of the brain regions examined. CONCLUSION: The results of this study suggest that levodopa does not affect( 123)I-FP-CIT brain imaging and confirm that it is not necessary to withdraw this medication to measure DAT levels with SPECT.

Aged↗

Percutaneous uterine artery embolization for the treatment of symptomatic fibroids: current status.

Uterine artery embolization (UAE) is increasingly being used as an alternative treatment to hysterectomy for symptomatic fibroids. Symptoms of pelvic pressure, urinary frequency and menorrhagia are controlled in 73-98% of patients who undergo UAE. At the 1-year follow-up, the uterus may shrink by up to 55% but re-growth of fibroid may however occur. The rate of major complications and amenorrhoea following this procedure is low, ranging in most series from 1 to 3.5% and 1 to 7%, respectively. Nevertheless, the rate of amenorrhoea in women over 45 seems to be higher. In order to completely block the arterial supply to the fibroid, UAE is typically performed in both uterine arteries. Different embolic agents are used such as polyvinyl alcohol, gelfoam and more recently gelatine tris-acryl microspheres. After UAE, perfusion of the uterus is maintained. Uterine function is therefore conserved and although women who become pregnant after UAE seem to be at risk for malpresentation, pre-term birth, cesarean delivery and postpartum hemorrhage, successful pregnancies after UAE have been reported in some series. A major technical problem with UAE remains the possible presence of fibroid blood supply from other sources, such as the ovarian arteries or other pelvic branches, which can lead to failure of the procedure. In conclusion, although randomized trials are still underway, UAE appears a good option for those patients who whish to conserve their fertility or when surgery is contra-indicated. However, to evaluate the long-term effects of UAE longer follow up is required.

Diagnostic Imaging↗

Scintimammography for the detection of breast cancer.

Scintimammography is a functional imaging technique whereby radionuclide tracers in the patient's breasts are observed with a radiation-detection camera (gamma-camera). Tracers are designed to accumulate in tumors more than in healthy tissue; the most common tracers used to date are Tc-99m sestamibi and Tc-99m tetrofosmin. Scintimammography is useful in some clinical indications as an adjunct to mammography and to reduce the rates of negative biopsies, and it is recommended for lesions where additional information is required to reach a definitive diagnosis. Patients with equivocal mammograms may benefit from this test, as well as women with dense breasts and those with implants, since scintigraphy is not affected by breast density and the photons arising from the radiotracer are not overly attenuated by implants. Scintimammography is also of value in patients with locally advanced breast cancer, for monitoring and predicting the response to neoadjuvant chemotherapy. The near availability of high-resolution breast-dedicated cameras will allow the suboptimal sensitivity in detecting cancers of less than 1 cm to be improved; this is currently the main limitation of scintimammography. These new devices also have the potential to increase the number of breast scintigraphies performed and the role of nuclear medicine in breast cancer imaging.

Breast Neoplasms↗

Increased brain apparent diffusion coefficient in tuberous sclerosis.

PURPOSE: To evaluate the water diffusivity of normal-appearing white matter (NAWM) in patients with tuberous sclerosis complex compared with that in control subjects. MATERIALS AND METHODS: Diffusion and conventional magnetic resonance (MR) imaging examinations were performed in 18 patients with clinically established tuberous sclerosis complex (10 male and eight female patients; mean age, 20.1 years; range, 12-30 years), as well as in 18 age-matched control subjects (nine male and nine female; mean age, 20.2 years; range, 11-28 years). Apparent diffusion coefficients (ADCs) were generated, and small elliptic regions of interest were manually placed both in perilesional NAWM and in six anatomic locations of NAWM remote from hamartomatous lesions. Perilesional ADCs were compared with those at the same anatomic site on the contralateral side of the brain (generalized linear regression analysis). ADCs from the predetermined sites in patients were compared with those in control subjects (generalized linear regression analysis). RESULTS: Supratentorial ADCs were higher in patients with tuberous sclerosis complex than in control subjects, and statistically significant differences were observed in the occipital white matter, frontal white matter, centrum semiovale, parietal white matter, and corona radiata (for each location, P <.001). Significant increases were also seen in the perilesional NAWM compared with NAWM at the same anatomic locations on the contralateral side (P <.001). Infratentorial ADCs were normal. CONCLUSION: Significant ADC increases were measured in the supratentorial NAWM.

Adolescent↗

Superselective embolization in posttraumatic priapism with glubran 2 acrylic glue.

Two patients with posttraumatic priapism underwent transcatheter embolization using microcoils, resulting in temporary penile detumescence and an apparent resolution of the artero-venous fistula. In both cases, priapism recurred 24 hours after the procedure and was successfully treated through selective transcatheter embolization of the nidus using acrylic glue (Glubran 2). The patients showed complete recovery of sexual activity within 30 days from the procedure and persistent exclusion of the artero-venous fistula after a 12-month follow-up.

Adhesives↗

Evaluation of anterior pituitary gland volume in childhood using three-dimensional MRI.

BACKGROUND: Three-dimensional MRI (3D-MRI) is a reliable tool for the evaluation of anatomical volumes. Volumetric measurement of the normal anterior pituitary gland in childhood has been performed in the past by 2D-MRI calculations, but has inherent inaccuracies. OBJECTIVE: To obtain accurate normal anterior pituitary gland volume in childhood using 3D-MRI coronal sections. MATERIALS AND METHODS: The anterior pituitary gland was measured using coronal T1-weighted 3D-gradient-echo sequences (section thickness 0.75 mm). The study group was composed of 95 prepubertal children (age range 2 months-10 years) with clinically normal pituitary function and no pituitary or brain abnormalities. RESULTS: A measurement error of 0.2-0.4% was assessed by using a phantom study. Volumetric evaluation of the anterior pituitary gland showed progressive growth of the gland from a mean 131+/-24 mm(3) at 2-12 months, to 249+/-25 mm(3) at 1-4 years and 271+/-29 mm(3) at 5-10 years. CONCLUSIONS: These data may be useful for paediatricians in the evaluation of patients with neuroendocrine diseases, in particular growth hormone deficiency.

Analysis of Variance↗

Technetium-99m-labelled red blood cell imaging in the diagnosis of hepatic haemangiomas: the role of SPECT/CT with a hybrid camera.

Delayed liver single-photon emission computed tomography (SPECT) after (99m)Tc red blood cell (RBC) labelling is helpful in detecting hepatic haemangiomas; however, diagnosis can be difficult when lesions are situated adjacent to structures like the inferior vena cava, the heart or hepatic vessels, where blood activity persists. The aims of this study were to evaluate the usefulness of RBC SPECT and transmission computed tomography (RBC SPECT/CT) performed simultaneously with a hybrid imaging system for correct characterisation of hepatic lesions in patients with suspected haemangioma, and to assess the additional value of fused images compared with SPECT alone. Twelve patients with 24 liver lesions were studied. The acquisitions of both anatomical (CT) and functional (SPECT) data were performed during a single session. SPECT images were first interpreted alone and then re-evaluated after adding the transmission anatomical maps. Image fusion was successful in all patients, with perfect correspondence between SPECT and CT data, allowing the precise anatomical localisation of sites of increased blood pool activity. SPECT/CT had a significant impact on results in four patients (33.3%) with four lesions defined as indeterminate on SPECT images, accurately characterising the hot spot foci located near vascular structures. In conclusion, RBC SPECT/CT imaging using this hybrid SPECT/CT system is feasible and useful in the identification or exclusion of suspected hepatic haemangiomas located near regions with high vascular activity.

Adult↗

Accuracy of thin-slice computed tomography in the detection of coronary stenoses.

AIM: Our aim was to investigate the accuracy of multislice spiral computed tomography (MSCT) in the detection of significant (>50%) coronary stenosis using a scanner equipped for 16 x 0.625 mm collimation. METHODS: In 64 patients (59 male, mean age 58 +/- 5 years) with suspected coronary artery disease, MSCT (GE Light Speed-16, collimation: 16 x 0.625 mm) was performed 20 +/- 5 days before coronary angiography (CAG). Only angiographic segments >1.5 mm were considered for analysis. RESULTS: In all patients, MSCT was carried out without complications. Three patients were excluded from the analysis. Of 729 angiographic segments, 613 (84%) were judged evaluable by MSCT. Considering only the segments judged evaluable, the sensitivity was 89%, specificity 98%, positive predictive value 90%, and negative predictive value 98%. Including all segments in the analysis (evaluable and nonevaluable), sensitivity was 78%. CONCLUSIONS: Using a scanner with a collimation of 16 x 0.625 mm, our study confirms the potential role of MSCT in the detection of significant coronary stenosis with a sensitivity of 89% and a very high specificity (98%). Exclusion criteria and less than full evaluability of the coronary arteries must still be considered limitations of the method.

Coronary Stenosis↗

Fusion imaging in nuclear medicine--applications of dual-modality systems in oncology.

Medical imaging has become of the utmost importance in evaluating patients with cancer. Single-photon emission computed tomography (SPECT) and positron emission tomography (PET) are accurate methods for detecting cancer and related metabolic abnormalities, but they often do not provide the anatomical landmarks needed to precisely localize lesions. Magnetic resonance imaging (MRI) and computed tomography (CT) scan, on the other hand, offer excellent anatomic detail but are less sensitive because they do not provide functional detail. Fusion imaging combines functional studies with morphological ones, so overcoming the drawbacks of both modalities. Software-based fusion of independently performed scintigraphic and radiological images has proven time consuming and impractical for routine use. Recently, dual-modality integrated imaging systems (SPECT/CT and PET/CT) have been developed: the acquired images are coregistered by means of the hardware in the same session. These new devices can be particularly useful for tumour imaging. The anatomical images provide precise localization and allow the exclusion of disease in sites of physiologic tracers' accumulation for SPECT and PET findings. Hybrid imaging in oncological applications has been very encouraging, indicating that these systems are suited for routine use in clinical practice. In fact, fused images provide additional information that improves diagnostic accuracy and impacts on patient management.

Diagnostic Imaging↗