Preliminary investigation of the feasibility of magnetic propulsion for future microdevices in blood vessels.

The Magnetic Resonance Submarine (MR-Sub) project is a first attempt to validate a new propulsion method for future small magnetically controlled microdevices suited for minimally invasive applications in blood vessels. A Magnetic Resonance Imaging (MRI) system provides the driving force in three dimensions to a ferromagnetic core that could be embedded onto a specialised microdevice. The paper describes preliminary tests made to match the magnetic force induced by an MRI system on a ferromagnetic sphere with the drag force it encompasses in a cylindrical tube. These tests provide a proof of concept demonstrating that this new method of propulsion is very promising within the constraints of such types of operations. This conclusion is based on specific measurements showing that 1010/1020 carbon steel spheres (3.175 mm and 2.381 mm in diameter) can withstand a maximum flow of 0.370 +/- 0.0064 l/min (19.5 cm/s) and 0.311 +/- 0.01209 l/min (16.4 cm/s) respectively when placed inside a 6.35 mm diameter PMMA tube and subjected to a 18 mT/m magnetic field gradient.

Blood Vessel Prosthesis↗

CT and MR imaging of nitinol stents with radiopaque distal markers.

PURPOSE: To evaluate imaging characteristics and artifacts of a nitinol stent with distal tantalum markers with computed tomography (CT) angiography and magnetic resonance (MR) angiography. MATERIALS AND METHODS: A vascular phantom was built to simulate in-stent restenosis. A nitinol stent with tantalum markers (Luminexx stent) was evaluated with CT angiography in different orientations relative to the z-axis and with MR angiography in different positions relative to both B0 and the readout gradient. Stenosis measurements were compared with conventional digital subtraction angiography for both modalities. In-stent signal intensity obtained with different flip angles was assessed in two nitinol stents with distal markers (Luminexx stent and SMART stent) and one without markers (Memotherm-FLEXX stent). RESULTS: Stenosis detection was not possible with CT angiography when the stent was perpendicular to the z-axis because of streak-like artifacts induced by tantalum markers. Stenosis evaluation with multiplanar reformation was accurate when the stent was in parallel and oblique orientations relative to the table axis. With MR angiography, metallic artifacts were mostly related to the stent orientation with B0, whereas orientation of the readout gradient had little influence. The mean error (overestimation) for stenosis measurements varied between 0.1% and 7.4% for CT imaging in parallel and oblique positions and 3.6% and 9.5% for MR imaging. Higher flip angles did not improve signal intensity inside the three stents tested. CONCLUSION: CT and MR angiography can be used for evaluating the patency of stents with distal markers that are parallel or oblique relative to the table axis (iliac, carotid, or femoral stents). MR angiography is preferred if the stent is perpendicular to the table axis (renal stent).

Alloys↗

Endovascular aortic aneurysm repair with stent-grafts: experimental models can reproduce endoleaks.

PURPOSE: To develop canine aneurysm models that can reproduce type II endoleaks after endovascular aneurysm repair (EVAR) with stent-grafts. MATERIALS AND METHODS: A fusiform infrarenal abdominal aortic aneurysm model (AAA) was surgically created with a jugular vein patch, while preserving collateral vessels (n = 3). To allow comparative studies within the same animal, a bilateral iliac aneurysm model was also constructed with venous patches and surgical re-implantation of the sacroiliac trunk (n = 3). Stent-grafts were implanted by femoral approach at least 2 months later in both aortic and iliac models. Follow-up imaging was performed by Doppler ultrasound (US) and angiography until animals were killed 3 months after EVAR. RESULTS: Angiography revealed immediate type II leaks in all cases. Leaks were still present at autopsy 3 months after EVAR in all cases, and were revealed at pre-death angiography in all but one case. At autopsy, leaks were characterized by the presence of large endothelialized channels that formed within the thrombus between the stent-graft and the aneurysmal wall. CONCLUSION: As shown in this pilot study, persistent type II leaks after EVAR can be reproduced in aortic and iliac animal models. The iliac model can be created bilaterally in the same animal, thus allowing for comparative evaluation of different therapies. These models could be used to better understand the mechanisms of endoleak, and to assess future developments aimed to improve the outcomes after EVAR.

Aneurysm↗

Noninvasive vascular elastography: theoretical framework.

Changes in vessel wall elasticity may be indicative of vessel pathologies. It is known, for example, that the presence of plaque stiffens the vascular wall, and that the heterogeneity of its composition may lead to plaque rupture and thrombosis. Another domain of application where ultrasound elastography may be of interest is the study of vascular wall elasticity to predict the risk of aneurysmal tissue rupture. In this paper, this technology is introduced as an approach to noninvasively characterize superficial arteries. In such a case, a linear array ultrasound transducer is applied on the skin over the region of interest, and the arterial tissue is dilated by the normal cardiac pulsation. The elastograms, the equivalent elasticity images, are computed from the assessment of the vascular tissue motion. Investigating the forward problem, it is shown that motion parameters might be difficult to interpret; that is because tissue motion occurs radially within the vessel wall while the ultrasound beam propagates axially. As a consequence of that, the elastograms are subjected to hardening and softening artefacts, which are to be counteracted. In this paper, the Von Mises (VM) coefficient is proposed as a new parameter to circumvent such mechanical artefacts and to appropriately characterize the vessel wall. Regarding the motion assessment, the Lagrangian estimator was used; that is because it provides the full two-dimensional strain tensor necessary to compute the VM coefficient. The theoretical model was validated with biomechanical simulations of the vascular wall properties. The results allow believing in the potential of the method to differentiate hard plaques and lipid pools from normal vascular tissue. Potential in vivo implementation of noninvasive vascular elastography to characterize abdominal aneurysms and superficial arteries such as the femoral and the carotid is discussed.

Algorithms↗

A multimodality vascular imaging phantom with fiducial markers visible in DSA, CTA, MRA, and ultrasound.

The objective was to design a vascular phantom compatible with digital subtraction angiography, computerized tomography angiography, ultrasound and magnetic resonance angiography (MRA). Fiducial markers were implanted at precise known locations in the phantom to facilitate identification and orientation of plane views from three-dimensional (3-D) reconstructed images. A vascular conduit connected to tubing at the extremities of the phantom ran through an agar-based gel filling it. A vessel wall in latex was included around the conduit to avoid diffusion of contrast agents. Using a lost-material casting technique based on a low melting point metal, geometries of pathological vessels were modeled. During the experimental testing, fiducial markers were detectable in all modalities without distortion. No leak of gadolinium through the vascular wall was observed on MRA after 5 hours. Moreover, no significant deformation of the vascular conduit was noted during the fabrication process (confirmed by microtome slicing along the vessel). The potential use of the phantom for calibration, rescaling, and fusion of 3-D images obtained from the different modalities as well as its use for the evaluation of intra- and inter-modality comparative studies of imaging systems are discussed. In conclusion, the vascular phantom can allow accurate calibration of radiological imaging devices based on x-ray, magnetic resonance and ultrasound and quantitative comparisons of the geometric accuracy of the vessel lumen obtained with each of these methods on a given well defined 3-D geometry.

Agar↗

Geometrical accuracy and fusion of multimodal vascular images: a phantom study.

The aim of this work was to compare the geometrical accuracy of x-ray angiography, magnetic resonance imaging (MRI), x-ray computed tomography (XCT), and ultrasound imaging (B-mode and IVUS, or intravascular ultrasound) for measuring the lumen diameters of blood vessels. An image fusion method was also developed to improve these measurements. The images were acquired from a phantom that mimic vessels of known diameters. After acquisition, the multimodal images were coregistered by manual alignment of fiducial markers, and then by maximization of mutual information. The fusion method was performed by means of a fuzzy logic modeling approach followed by a combination process based on a possibilistic theory. The results showed (i) the better geometrical accuracy of XCT and IVUS compared to the other modalities, and (ii) the better accuracy and smaller variability of fused images compared to single modalities, with respect to most diameters investigated. For XCT, the error varied from 0.4% to 5.4%, depending on the vessel diameter that ranged from 0.93 to 6.24 mm. For IVUS, the error ranged from -0.3% to 1.7% but the smallest vessel (0.93 mm) could not be investigated because of the probe size. Compared to others fusion schemes, the XCT-MRI fused images provided the best results for both accuracy (from -1.6% to 0.2% for the three largest vessels) and robustness (mean relative error of 1.9%). To conclude, this work underlined both the usefulness of the multimodality vascular phantom as a validation tool and the utility of image fusion in the vascular context.

Angiography↗

Aortoduodenal fistula occurring after type II endoleak treatment with coil embolization of the aortic sac.

A bifurcated stent graft device was successfully deployed to exclude an asymptomatic abdominal aortic aneurysm (AAA) with adequate proximal aortic neck morphology. At 6 months, a type II endoleak was successfully embolized through a proximal perigraft channel with metallic coils. The patient was seen with upper gastrointestinal bleeding and a pulsatile abdominal mass 11 months later. Surgical exploration revealed an aortoduodenal fistula in the vicinity of the previous embolization. We discuss the possible causes of this complication and review the literature on the subject. We conclude that aortoduodenal fistula can occur after endovascular AAA repair despite the absence of endoleak or AAA diameter increase on follow-up computed tomographic scan.

Aged↗

Prediction of clinical response after renal angioplasty: respective value of renal Doppler sonography and scintigraphy.

OBJECTIVE: The goal of our study was to compare Doppler sonography and renal scintigraphy as tools for predicting the therapeutic response in patients after undergoing renal angioplasty. SUBJECTS AND METHODS. Seventy-four hypertensive patients underwent clinical examination, Doppler sonography, and renal scintigraphy before and after receiving captopril in preparation for renal revascularization. The patients were evaluated for the status of hypertension 3 months after the procedure. The predictive values of the findings of clinical examination, Doppler sonography, renal scintigraphy, and angiography were assessed. RESULTS: For prediction of a favorable therapeutic outcome, abnormal results from renal scintigraphy before and after captopril administration had a sensitivity of 58% and specificity of 57%. Findings of Doppler sonography had a sensitivity of 68% and specificity of 50% before captopril administration and a sensitivity of 81% and specificity of 32% after captopril administration. Significant predictors of a cure or reduction of hypertension after revascularization were low unilateral (p = 0.014) and bilateral resistive (p = 0.016) indexes on Doppler sonography before (p = 0.009) and after (p = 0.028) captopril administration. On multivariate analysis, the best predictors were a unilateral resistive index of less than 0.65 (odds ratio [OR] = 3.7) after captopril administration and a kidney longer than 93 mm (OR = 7.8). The two best combined criteria to predict the favorable therapeutic outcome were a bilateral resistive index of less than 0.75 before captopril administration combined with a unilateral resistive index of less than 0.70 after captopril administration (sensitivity, 76%; specificity, 58%) or a bilateral resistive index of less than 0.75 before captopril administration and a kidney measuring longer than 90 mm (sensitivity, 81%; specificity, 50%). CONCLUSION: Measurements of kidney length and unilateral and bilateral resistive indexes before and after captopril administration were useful in predicting the outcome after renal angioplasty. Renal scintigraphy had no significant predictive value.

Aged↗

Gadolinium-enhanced pulmonary magnetic resonance angiography in the diagnosis of acute pulmonary embolism: a prospective study on 48 patients.

OBJECTIVE: Gadolinium-enhanced pulmonary magnetic resonance angiography (MRA) can be an option in patients with a history of previous adverse reaction to iodinated contrast material and renal insufficiency. Radiation is also avoided. The aim of this study is to prospectively compare the diagnostic value of MRA with that of a diagnostic strategy, taking into account catheter angiography, computed tomography angiography (CTA), and lung scintigraphy [ventilation-perfusion (VQ)]. MATERIAL AND METHODS: Magnetic resonance angiography was done in 48 patients with clinically suspected pulmonary embolism (PE) using fast gradient echo coronal acquisition with gadolinium. Interpretation was done with native coronal images and multiplanar maximum intensity projection reconstructions. Results were compared to catheter angiography (n=15), CTA (n=34), VQ (n=45), as well as 6-12 months clinical follow-ups, according to a sequenced reference tree. RESULTS: The final diagnosis of PE was retained in 11 patients (23%). There were two false negatives and no false positive results with MRA. Computed tomography angiography resulted in no false negatives or false positives. Magnetic resonance angiography had a sensitivity of 82% and a specificity of 100%. CONCLUSION: In our study, pulmonary MRA had a sensitivity of 82% and a specificity of 100% for the diagnosis of PE, with slightly less sensitivity than CTA. In the diagnostic algorithm of PE, pulmonary MRA should be considered as an alternative to CTA when iodine contrast injection or radiation is a significant matter.

Acute Disease↗

Balloon dilation and stent placement for esophageal lesions: indications, methods, and results.

Esophageal balloon dilation and expandable stent placement are safe, minimally invasive, effective treatments for esophageal strictures and fistulas. These procedures have brought the management of dysphagia due to esophageal strictures into the field of interventional radiology. Esophageal dilation is usually indicated for benign stenoses and is technically successful in more than 90% of cases. Most patients with esophageal carcinoma are not candidates for resection; thus, the main focus of treatment is palliation of malignant dysphagia and esophagorespiratory fistulas. Esophageal stent placement, which is approved only for malignant strictures, is one of the main therapeutic options in affected patients and relieves dysphagia in approximately 90% of cases. Dedicated commercially available devices continue to evolve, each with its own advantages and limitations. Stent placement is subject to technical pitfalls, and adverse events occur following esophageal procedures in a minority of cases. Although chest pain is common and self-limited, reflux esophagitis, stent migration, tracheal compression, and esophageal perforation and obstruction require specific interventions. In many cases, these complications can be recognized and treated by the interventional radiologist with minimally invasive techniques.

Catheterization↗

Stent-graft placement for the treatment of thoracic aortic diseases.

The recent development of aortic stent-grafts has brought the management of thoracic aortic diseases into the realm of interventional radiology. Stent-graft placement is now an alternative to surgery for the treatment of descending thoracic aortic aneurysms, ulcers, and fistulas and is sometimes indicated in cases of mycotic aneurysm, posttraumatic aortic rupture, or thoracic descending aortic dissection. Pretreatment imaging is crucial for evaluating patient eligibility, selecting the appropriate stent-graft, and planning the intervention. Stent-graft treatment of long atherosclerotic aneurysms, lesions close to aortic branch vessels, and aortic dissections is subject to technical pitfalls, and adverse events such as endoleaks, stent migration or misplacement, aortic perforation, and vascular trauma will require specific interventions, although they occur in only a minority of patients. Thoracic stent-graft placement in good surgical candidates remains controversial because long-term results are unknown. However, short-term morbidity and mortality rates from endovascular treatment compare favorably with those from surgery, and stent-graft placement is proving to be a safe, minimally invasive, and effective treatment for thoracic aortic diseases and is already the best option in many affected patients who are poor surgical candidates.

Aorta, Thoracic↗