Search PubMed⌕ Search

Biomedical subjects

Giampaolo Pasquetto

Publications and source records attributed to Giampaolo Pasquetto.

8 recordsLinked to original sources

[Percutaneous coronary interventions in elderly patients: clinical indications and adjunctive medical treatment. The Italian Drug Evaluation in Angioplasty (IDEA) study].

BACKGROUND: Specific guidelines for interventional cardiology in elderly patients are not available, and it appears that aged patients are treated more conservatively. Nevertheless data on the real clinical practice are lacking. The aim of the study was to describe different therapeutic strategies in elderly patients enrolled in the Italian Drug Evaluation in Angioplasty (IDEA) study. METHODS: The IDEA study is a registry of consecutive percutaneous coronary interventions (PCI) performed from September 15 to 29, 2003, at 79 Italian cath-labs. RESULTS: Out of 1517 consecutive PCI patients, 491 (32%) were aged > or = 70 years. Compared to younger patients, those > or = 70 years old showed more frequently (p < 0.001) renal insufficiency (10.4 vs 4.4%), peripheral vasculopathy (18 vs 6.9%), history of stroke (7.3 vs 3.3%) or previous surgical coronary revascularization (15 vs 7.5%) and multivessel disease (61 vs 49%). In patients aged > or = 70 years, acute coronary syndrome was the more frequent clinical indication for PCI (54 vs 49% in patients < 70 years, p = 0.05). Globally, stent use was 89% with no differences related to the patients' age. Drug-eluting stents were used in 21% of the procedures in elderly patients and in 22% in younger patients. Use of glycoprotein IIb/IIIa receptor antagonists in acute coronary syndrome was not correlated with the patients' age; nevertheless in elderly patients with acute myocardial infarction these drugs were less used during primary angioplasty compared to younger patients (48 vs 72%, p = 0.001). In-hospital mortality was higher in patients aged > or = 70 years (2.9 vs 0.9%, p = 0.004), particularly in patients treated for acute coronary syndromes (5.5 vs 1.4%, p = 0.002). In these patients, more bleeding complications (7.1 vs 3.9%, p < 0.001) and heart failure (5.5 vs 1.6%, p = 0.004) were observed. CONCLUSIONS: Compared to younger patients, elderly patients enrolled in the IDEA study had a higher risk profile and higher in-hospital morbidity and mortality. Except for a lower use of glycoprotein IIb/IIIa receptor antagonists for acute myocardial infarction, no discriminations were observed in elderly patients in terms of clinical indications, antiplatelet therapy and drug-eluting stent use.

Age Factors↗

High-tech primary percutaneous coronary intervention.

Coronary recanalization by means of primary percutaneous coronary intervention is actually the treatment of choice in patients with ST-elevation myocardial infarction. However, conventional primary percutaneous coronary intervention still presents several limitations. In recent years sophisticated new devices and techniques have been developed to further improve the results of primary percutaneous coronary intervention: it seems to be appropriate to refer to their utilization using the definition "high-tech primary percutaneous coronary intervention". Although the study data available are controversial and clinical benefits have not clearly been shown, adjunctive devices have been used in many procedures. Patient and lesion selection appears to be crucial and the health economics as well as the safety of high-tech devices should be carefully evaluated.

Angioplasty, Balloon, Coronary↗

[Hospital epidemiology of ST-segment elevation myocardial infarction and feasibility of primary percutaneous coronary intervention in an interhospital network: data from a multicenter, prospective and observational study VENERE (VENEto acute myocardial infarction REgistry].

BACKGROUND: Primary percutaneous coronary intervention (pPCI) is the most effective reperfusion treatment of acute ST-segment elevation myocardial infarction (STEMI), but logistic- and organization-related problems affect its feasibility. The aim of this study was to investigate a) the requirements of reperfusion therapies, and b) the feasibility of pPCI as suggested by the current guidelines, in the Veneto Region. METHODS: With the aim to treat with pPCI most of the patients with high-risk STEMI regardless of the type of admitting hospital, a single treatment protocol was developed and shared by the majority of Cardiology Departments in the Veneto Region. Data of all consecutive patients with STEMI were prospectively recorded and subsequently and independently compared with administrative data. RESULTS: In 28 participating hospitals, 1160 consecutive patients with STEMI were enrolled during a 6-month period: in 999 symptom onset was < 12 hours. Based on the registry data, it is possible to estimate that 697 patients/million of inhabitants/year are admitted in Cardiology Departments with the initial diagnosis of STEMI: 86% are admitted < 12 hours from symptom onset and 58% of them have at least one characteristic of high risk. The strategy of immediate coronary angiography and possible PCI was carried out in 52.3% of eligible patients: in 55.8 and 47.5% of high- and low-risk STEMI and from 17.1 to 75.1% based on the type of admitting hospital. Recanalization with pPCI was obtained < 90 min from the diagnosis in 70 and 32% of patients treated on site and transferred, respectively. CONCLUSIONS: The absolute number of patients with STEMI eligible for reperfusion therapies is lower than previously reported. The reperfusion strategy based on pPCI was much more related to the type of admitting hospital than to the clinical characteristics of the patients. pPCI performed as suggested by the current guidelines is feasible in patients admitted in hospitals with interventional facilities available 24 hours/day, but in those who need to be transferred it is necessary to modify the existing pathways and/or treatment protocols.

Angioplasty, Balloon, Coronary↗

Intracoronary thrombectomy improves myocardial reperfusion in patients undergoing direct angioplasty for acute myocardial infarction.

OBJECTIVES: We sought to evaluate the effects of mechanical thrombectomy on myocardial reperfusion during direct angioplasty for acute myocardial infarction (AMI). BACKGROUND: Embolization of thrombus and plaque debris may occur during direct angioplasty for AMI. This may lead to distal vessel or side branch occlusion and to obstructions in the microvascular system, resulting in impaired myocardial reperfusion. Mechanical thrombectomy is used to reduce distal embolization. METHODS: Ninety-two patients with AMI and angiographic evidence of intraluminal thrombus were randomized to either intracoronary thrombectomy followed by stenting or to a conventional strategy of stenting. Thrombectomy was performed using the X-Sizer catheter (EndiCOR Inc., San Clemente, California). Myocardial reperfusion was assessed by myocardial blush and ST resolution. RESULTS: Postprocedure Thrombolysis in Myocardial Infarction-3 flow was not different between groups (93.5% vs. 95.7%, p = 0.39). Myocardial blush-3 was observed in 71.7% of patients undergoing thrombectomy and in 36.9% of patients undergoing conventional strategy (p = 0.006). ST-segment resolution >or=50% occurred more often in patients undergoing thrombectomy (82.6% vs. 52.2%, p = 0.001). By multivariate analysis, adjunctive thrombectomy was an independent predictor of blush-3 (odds ratio, 3.27; 95% confidence interval, 1.06 to 10.05; p = 0.039). CONCLUSIONS: Intracoronary thrombectomy as adjunct to stenting during direct angioplasty for AMI improves myocardial reperfusion as assessed by myocardial blush and ST resolution.

Angioplasty, Balloon, Coronary↗

Distal filter protection during percutaneous coronary intervention in native coronary arteries and saphenous vein grafts in patients with acute coronary syndromes.

BACKGROUND: Percutaneous coronary interventions on saphenous vein grafts (SVG) and in patients with acute coronary syndromes (ACS) have been associated with the distal embolization of the thrombus and plaque and to the no-reflow phenomenon. We report on the safety and feasibility of a new distal emboli protection filter. METHODS: Angioplasty using distal filter protection (Angioguard, Cordis, Warren, NJ, USA) was attempted in 38 patients (mean age 65 +/- 11 years, 79% males) affected by ACS. A percutaneous coronary intervention was performed in 27 native coronary arteries, in 10 SVG and in one arterial graft (mean diameter stenosis 88 +/- 9%). Patients with vessels presenting severe proximal tortuosity, more than mild calcification, a diameter < 3.0 mm and a lesion length > 15 mm were excluded. RESULTS: It was possible to position the device in all patients (100%); in 7 patients (18%) the lesion could be crossed with the filter only after balloon predilation. Procedural success with final TIMI flow 3 was obtained in all patients and the mean residual diameter stenosis after stent implantation was 5 +/- 8%. Transient procedural complications without clinical sequelae included the no-reflow phenomenon (2 patients, 5%) and vessel perforation (1 patient, 2.5%). In no case was distal embolization observed. As regards the device-related complications, one occlusive dissection (2.5%) occurred and was successfully treated with stent implantation. In-hospital and 30-day major adverse cardiac events consisted of two non-Q wave myocardial infarctions (5%), both occurring during SVG interventions. CONCLUSIONS: The use of the Angioguard filter for preselected lesions in patients with ACS had a high technical success and carried a low rate of device-related complications. The clinical efficacy of the device needs further evaluation.

Acute Disease↗

Carotid artery stenting with cerebral protection in 100 consecutive patients: immediate and two-year follow-up results.

BACKGROUND: Carotid artery stenting is emerging as an alternative to surgical endarterectomy for the treatment of extracranial carotid artery disease. However, few data are available on the long-term clinical efficacy of carotid artery stenting and on the incidence of restenosis. METHODS: Stent implantation with the routine use of cerebral protection devices was attempted in a single center experience including 100 consecutive patients (104 lesions) with significant stenosis of the internal carotid artery (mean stenosis 82.8 +/- 9%). The mean age of the patients was 70.8 +/- 14 years, 27 lesions were symptomatic (26.0%) with a lesion related to a previous stroke or transient ischemic attack. RESULTS: Procedural success was achieved in 103 lesions (99%) and the cerebral protection was successfully applied in 102 procedures (98%). The 30-day incidence of stroke and death was 4% (4 patients). Complications consisted of one major stroke (1%) with persistent ipsilateral amaurosis, two minor strokes (2%), and one (1%) fatal myocardial infarction occurring 4 days after the stent procedure. During follow-up (minimum 24 months; mean 31 +/- 6 months) no further neurological events occurred, 6 patients died of non-neurological causes (6%) and 2 (2%) presented with a non-fatal myocardial infarction. Echo color Doppler scan control (minimum 24 months) was carried out in all surviving patients showing a restenosis classified as moderate (50-69%) in 2 cases and as critical (> or = 70%) in another 2 cases (1.8%). Both critical restenotic lesions were successfully treated by repeating balloon angioplasty. CONCLUSIONS: The present study demonstrates that carotid artery stenting with routine cerebral protection can be performed with an acceptable procedural complication rate. At the 2-year follow-up carotid artery stenting appeared effective in stroke prevention and durable with a low incidence of restenosis.

Aged↗

Cerebral protection during carotid artery stenting: collection and histopathologic analysis of embolized debris.

BACKGROUND AND PURPOSE: Histopathologic analysis was performed to better understand quantity, particle size, and composition of embolized debris collected in protection filters during carotid artery stent implantation. METHODS: Elective carotid stent implantation with the use of a distal filter protection was attempted in 38 consecutive lesions (36 patients) of the internal carotid artery presenting >70% diameter stenosis (mean, 82.1+/-11.1%). Mean age of the patients was 70.7+/-7.7 years; 75% were men, and 50% of patients had previous neurological symptoms. RESULTS: In 37 lesions (97.4%) it was possible to position the filter device, and in all lesions a stent was successfully implanted. The only complication occurring in the hospital and during the 30-day follow-up was 1 death due to acute myocardial infarction. Neurological sequelae did not occur. Histomorphometric analysis was performed on the filters. Presence of debris was detected in 83.7% of filters. The mean surface area of the polyurethane membrane filter covered with material was 53.2+/-19.8%. Particle size ranged from 1.08 to 5043.5 microm (mean, 289.5+/-512 microm) in the major axis and 0.7 to 1175.3 microm (mean, 119.7+/-186.7 microm) in the minor axis. Collected debris consisted predominantly of thrombotic material, foam cells, and cholesterol clefts. CONCLUSIONS: By the use of distal protection filters during carotid artery stenting, it was possible to collect particulate debris potentially leading to distal vessel occlusion in a high percentage of cases. Qualitative analysis of embolized material showed debris dislocated during the percutaneous intervention from atheromatous plaques.

Aged↗

Percutaneous endovascular stent-graft placement for the treatment of acute rupture of an aneurysm of the thoracic aorta.

A 68-year-old male patient presented with massive hematemesis following the acute rupture of an aneurysm of the descending thoracic aorta into the esophagus. In view of the important cardiac and pulmonary comorbidities, surgical treatment was excluded and successful percutaneous implantation of an endovascular stent-graft in the descending aorta was performed. In selected patients endovascular treatment may constitute an alternative to the surgical repair of ruptured aortic aneurysms.

Aged↗