Search PubMed⌕ Search

Biomedical subjects

Ger van den Engh

Publications and source records attributed to Ger van den Engh.

9 recordsLinked to original sources

A dual-fluorescence reporter system for high-throughput clone characterization and selection by cell sorting.

Molecular biology critically depends upon the isolation of desired DNA sequences. Flow cytometry, with its capacity to interrogate and sort more than 50,000 cells/s, shows great potential to expedite clone characterization and isolation. Intrinsic heterogeneity of protein expression levels in cells limits the utility of single fluorescent reporters for cell-sorting. Here, we report a novel dual-fluorescence strategy that overcomes the inherent limitations of single reporter systems by controlling for expression variability. We demonstrate a dual-reporter system using the green fluorescent protein (GFP) gene fused to the Discosoma red fluorescent protein (DsRed) gene. The system reports the successful insertion of foreign DNA with the loss of DsRed fluorescence and the maintenance of GFP fluorescence. Single cells containing inserts are readily recognized by their altered ratios of green to red fluorescence and separated using a high-speed cell-sorter for further processing. This novel reporter system and vector were successfully validated by shotgun library construction, cloned sequence isolation, PCR amplification and DNA sequencing of cloned inserts from bacteria after cell-sorting. This simple, robust system can also be adapted for diverse biosensor assays and is amenable to miniaturization. We demonstrated that dual-fluorescence reporting coupled with high-speed cell-sorting provides a more efficient alternative to traditional methods of clone isolation.

Cell Separation↗

Chromatic shifts in the fluorescence emitted by murine thymocytes stained with Hoechst 33342.

BACKGROUND: Many methods in flow cytometry rely on staining DNA with a fluorescent dye to gauge DNA content. From the relative intensity of the fluorescence signature, one can then infer position in cell cycle, amount of DNA (i.e., for sperm selection), or, as in the case of flow karyotyping, to distinguish individual chromosomes. This work examines the staining of murine thymocytes with a common DNA dye, Hoechst 33342, to investigate nonlinearities in the florescence intensity as well as chromatic shifts. METHODS: Murine thymocytes were stained with Hoechst 33342 and measured in a flow cytometer at two fluorescence emission bands. In other measurements, cells were stained at different dye concentrations, and then centrifuged. The supernatant was then used for a second round of staining to test the amount of dye uptake. Finally, to test for resonant energy transfer, we measured fluorescence anisotropy at two different wavelengths. RESULTS: The fluorescence of cells stained with Hoechst 33342 is a nonlinear process that shows an overall decrease in intensity with increased dye uptake, and spectral shift to the red. Along with the spectral shift of the fluorescence to the longer wavelengths, we document decreases in the fluorescence anisotropy that may indicate resonant energy transfer. CONCLUSIONS: At low concentrations, Hoechst 33342 binds to the minor groove of DNA and shows an increase in fluorescence and a blue shift upon binding. At higher concentrations, at which the dye molecules can no longer bind without overlapping, the blue fluorescence decreases and the red fluorescence increases until there is approximately one dye molecule per DNA base pair. The ratio of the blue fluorescence to the red fluorescence is an accurate indicator of the cellular dye concentration.

Animals↗

The polarization of fluorescence of DNA stains depends on the incorporation density of the dye molecules.

BACKGROUND: The fluorescence induced by polarized light sources, such as the lasers that are used in flow cytometry, is often polarized and anisotropic. In addition, most optical detector systems are sensitive to the direction of polarization. These two factors influence the accuracy of fluorescence intensity measurements. The intensity of two light sources can be compared only if all details of the direction and degree of polarization are known. In a previous study, we observed that fluorescence polarization might be modified by dye-dye interactions. This report further investigates the role of dye density in fluorescence polarization anisotropy. METHODS: We measured the polarization distribution of samples stained with commonly used DNA dyes. To determine the role of fluorophore proximity, we compared the monomeric and a dimeric form of the DNA dyes ethidium bromide (EB), thiazole orange (TO), and oxazole yellow (YO). RESULTS: In all dyes sampled, fluorescence polarization is less at high dye concentrations than at low concentrations. The monomeric dyes exhibit a higher degree of polarization than the dimeric dyes of the same species. CONCLUSIONS: The polarization of fluorescence from DNA dyes is related to the density of incorporation into the DNA helix. Energy transfer between molecules that are in close proximity loosens the linkage between the excitation and emission dipoles, thereby reducing the degree of polarization of the emission.

Animals↗

High-speed chromosome sorting.

Structural and genetic characterization of chromosomes is necessary to understand both normal and pathologic physiology in any species. Flow cytometry and cell sorting technologies provide a means for precise measurement of chromosomal makeup as well as for the isolation of specific chromosomes for further study. Advancements in molecular biology protocols and pressures from large-scale sequencing endeavors placed increased demand on the developers of these instruments for enhanced throughput and quality of results. The ensuing improvements in sorting performance led to the development of a new generation of cytometers known as high-speed cell sorters. These machines provide superior results in less time and are cheaper and simpler to operate than their predecessors. Robust chromosome sorting can now be performed in the laboratories of individual investigators for a variety of gene- and sequence-specific studies. Resolution of the flow karyotype with increased refinement, and the development of new applications for this technology will assure that cell sorting continues to play an important role in cytogenetics, our understanding of molecular processes such as evolution and disease etiology, and ultimately serve as a launching point for predictive medicine.

Animals↗

Stability of the breakoff point in a high-speed cell sorter.

BACKGROUND: High-speed jet-in-air cytometric sorting requires knowledge of the time it takes a particle to travel from the laser to the point where the jet breaks into droplets. Variations in this breakoff time will result in poorer yields and poorer sort purities. METHODS: This work examined the physical mechanisms that lead to the break up of the jet into droplets and calculated the stability of the droplet breakoff time relative to physical parameters, which govern the behavior of the jet. RESULTS: We derived the variations in the breakoff time and found that small variations in the drive frequency, temperature, pressure, and drive amplitude can lead to correspondingly large changes in the breakoff time. We found explicitly that the time it takes the jet to break up is not necessarily correlated with the distance to the breakoff point. CONCLUSIONS: Many high-speed cell sorters use active means to control the breakoff time. A common method to monitor the breakoff time is to visually monitor the breakoff point. This technique in fact may decrease the sorting purity and efficiency by inadvertently correcting for breakoff time variations. We show explicitly the breakoff time's dependence on a number of physical parameters that can be monitored to increase the stability of the breakoff time.

Cell Separation↗

High-speed cell sorting: fundamentals and recent advances.

Cell sorters have undergone dramatic technological improvements in recent years. Driven by the increased ability to differentiate between cell types, modern advances have yielded a new generation of cytometers, known as high-speed cell sorters. These instruments are capable of higher throughput than traditional sorters and can distinguish subtler differences between particles by measuring and processing more optical parameters in parallel. These advances have expanded their use to facilitate genomic and proteomic discovery, and as vehicles for many emerging cell-based therapies. High-speed cell sorting is becoming established as an essential research tool across a broad range of scientific fields and is poised to play a pivotal role in the latest therapeutic modalities.

Cell Separation↗

Use of fluorescent sequence-specific polyamides to discriminate human chromosomes by microscopy and flow cytometry.

In this paper, we demonstrate the use of synthetic polyamide probes to fluorescently label heterochromatic regions on human chromosomes for discrimination in cytogenetic preparations and by flow cytometry. Polyamides bind to the minor groove of DNA in a sequence-specific manner. Unlike conventional sequence-specific DNA or RNA probes, polyamides can recognize their target sequence without the need to subject chromosomes to harsh denaturing conditions. For this study, we designed and synthesized a polyamide to target the TTCCA-motif repeated in the heterochromatic regions of chromosome 9, Y and 1. We demonstrate that the fluorescently labeled polyamide binds to its target sequence in both conventional cytogenetic preparations of metaphase chromosomes and suspended chromosomes without denaturation. Chromosomes 9 and Y can be discriminated and purified by flow sorting on the basis of polyamide binding and Hoechst 33258 staining. We generate chromosome 9- and Y-specific 'paints' from the sorted fractions. We demonstrate the utility of this technology by characterizing the sequence of an olfactory receptor gene that is duplicated on multiple chromosomes. By separating chromosome 9 from chromosomes 10-12 on the basis of polyamide fluorescence, we determine and differentiate the haplotypes of the highly similar copies of this gene on chromosomes 9 and 11.

Base Sequence↗

Human prostate epithelial cell-type cDNA libraries and prostate expression patterns.

BACKGROUND: Transcriptome analysis is a powerful approach to uncovering genes responsible for diseases such as prostate cancer. Ideally, one would like to compare the transcriptomes of a cancer cell and its normal counterpart for differences. METHODS: Prostate luminal and basal epithelial cell types were isolated and cell-type-specific cDNA libraries were constructed. Sequence analysis of cDNA clones generated 505 luminal cell genes and 560 basal cell genes. These sequences were deposited in a public database for expression analysis. RESULTS: From these sequences, 119 unique luminal expressed sequence tags (ESTs) were extracted and assembled into a luminal-cell transcriptome set, while 154 basal ESTs were extracted and assembled into a basal-cell set. Interlibrary comparison was performed to determine representation of these sequences in cDNA libraries constructed from prostate tumors, PIN, cell lines. CONCLUSIONS: Our analysis showed that a significant number of epithelial cell genes were not represented in the various transcriptomes of prostate tissues, suggesting that they might be underrepresented in libraries generated from tissue containing multiple cell types. Although both luminal and basal cell types are epithelial, their transcriptomes are more divergent from each other than expected, underscoring their functional difference (secretory vs. nonsecretory). Tumor tissues show different expression of luminal and basal genes, with perhaps a trend towards expression of basal genes in advanced diseases.

DNA, Complementary↗

Trapping of DNA by dielectrophoresis.

Under suitable conditions, a DNA molecule in solution will develop a strong electric dipole moment. This induced dipole allows the molecule to be manipulated with field gradients, in a phenomenon known as dielectrophoresis (DEP). Pure dielectrophoretic motion of DNA requires alternate current (AC) electric fields to suppress the electrophoretic effect of the molecules net charge. In this paper, we present two methods for measuring the efficiency of DEP for trapping DNA molecules as well as a set of quantitative measurements of the effects of strand length, buffer composition, and frequency of the applied electric field. A simple configuration of electrodes in combination with a microfluidic flow chamber is shown to increase the concentration of DNA in solution by at least 60-fold. These results should prove useful in designing practical microfluidic devices employing this phenomenon either for separation or concentration of DNA.

Bacteriophage lambda↗