Search PubMed⌕ Search

Biomedical subjects

George Starkschall

Publications and source records attributed to George Starkschall.

At least 19 recordsLinked to original sources

Semi-automated CT segmentation using optic flow and Fourier interpolation techniques.

In radiotherapy treatment planning, tumor volumes and anatomical structures are manually contoured for dose calculation, which takes time for clinicians. This study examines the use of semi-automated segmentation of CT images. A few high curvature points are manually drawn on a CT slice. Then Fourier interpolation is used to complete the contour. Consequently, optical flow, a deformable image registration method, is used to map the original contour to other slices. This technique has been applied successfully to contour anatomical structures and tumors. The maximum difference between the mapped contours and manually drawn contours was 6 pixels, which is similar in magnitude to difference one would see in manually drawn contours by different clinicians. The technique fails when the region to contour is topologically different between two slices. A solution is recommended to manually delineate contours on a sparse subset of slices and then map in both directions to fill the remaining slices.

Algorithms↗

The potential for dose escalation in lung cancer as a result of systematically reducing margins used to generate planning target volume.

PURPOSE: To determine how much the radiation dose to lung tumors could be increased as the margins used to generate planning target volume (PTV) are reduced. METHODS AND MATERIALS: Treatment plans for 18 patients with non-small-cell lung carcinoma were retrospectively generated. Dose escalation was performed in two phases: The dose was increased as long as healthy tissue dose-volume constraints did not exceed (1) the values from the treatment plan originally used for the patients and (2) clinically acceptable values. RESULTS: No correlation of dose escalation was observed with tumor location, tumor stage, tumor motion, and tumor volume. An increase in dose was observed for many of the patients with as little as 2-mm uniform reduction in PTV margin, with increases in mean PTV dose exceeding 15 Gy for 5 patients. Sixteen of 18 patients experienced a decrease in mean heart, esophagus, and lung dose when margins were reduced and prescription doses were increased. CONCLUSIONS: Reduced margins allowed an increased dose to the tumors. However, a much larger dose escalation was possible for some patients but not for others, demonstrating that each patient is different, so individual treatment plans must be tailored for maximum tumor coverage and minimum exposure of healthy tissue.

Aged↗

Displacement-based binning of time-dependent computed tomography image data sets.

Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment have recently used a technique developed for cardiac CT imaging to track respiratory-induced anatomical motion and to sort images according to the phase of the respiratory cycle they represent. Here we propose a method of generating CT images that accounts for respiratory-induced anatomical motion on the basis of displacement, i.e., displacement-binned CT image sets. This technique has shown great promise, however, it is not fully supported by currently used CT image reconstruction software. As an interim solution, we have developed a method for extracting displacement-binned CT image data sets from data sets assembled on the basis of a prospectively determined breathing phase acquired on a multislice helical CT scanner. First, the projection data set acquired from the CT scanner was binned at small phase intervals before reconstruction. The manufacturer's software then generated image sets identified as belonging to particular phases of the respiratory cycle. All images were then individually correlated to the displacement of an external fiducial marker. Next, CT image data sets were resorted on the basis of the displacement and assigned an appropriate phase. Finally, displacement-binned image data sets were transferred to a treatment-planning system for analysis. Although the technique is currently limited by the phase intervals allowed by the CT software, some improvement in image reconstruction was seen, indicating that this technique is useful at least as an interim measure.

Algorithms↗

Application of the electron pencil beam redefinition algorithm to electron arc therapy.

This project investigated the potential of summing fixed-beam dose distributions calculated using the pencil-beam redefinition algorithm (PBRA) at small angular steps (1 degree) to model an electron arc therapy beam. The PRBA, previously modified to model skin collimation, was modified further by incorporating two correction factors. One correction factor that is energy, SSD (source-to-surface distance), and field-width dependent constrained the calculated dose output to be the same as the measured dose output for fixed-beam geometries within the range of field widths and SSDs encountered in arc therapy. Another correction factor (single field-width correction factor for each energy) compensated for large-angle scattering not being modeled, allowing a more accurate calculation of dose output at mid arc. The PBRA was commissioned to accurately calculate dose in a water phantom for fixed-beam geometries typical of electron arc therapy. Calculated central-axis depth doses agreed with measured doses to within 2% in the low-dose gradient regions and within 1-mm in the high-dose gradient regions. Off-axis doses agreed to within 2 mm in the high-dose gradient regions and within 3% in the low-dose gradient regions. Arced-beam calculations of dose output and depth dose at mid arc were evaluated by comparing to data measured using two cylindrical water phantoms with radii of 12 and 15 cm at 10 and 15 MeV. Dose output was measured for all combinations of phantom radii of curvature, collimator widths (4, 5, and 6 cm), and arc angles (0 degrees, 20 degrees, 40 degrees, 60 degrees, 80 degrees, and 90 degrees) for both beam energies. Results showed the calculated mid-arc dose output to agree within 2% of measurement for all combinations. For a 90 degree arc angle and 5 x 20 cm2 field size, the calculated mid-arc depth dose in the low-dose gradient region agreed to within 2% of measurement for all depths at 10 MeV and for depths greater than depth of dose maximum R100 at 15 MeV. For depths in the buildup region at 15 MeV the calculations overestimated the measured dose by as much as 3.4%. Mid-arc depth dose in the high-dose gradient region agreed to within 2.2 mm of measured dose. Calculated two-dimensional relative dose distributions in the plane of rotation were compared to dose measurements using film in a cylindrical polystyrene phantom for a 90 degree arc angle and field widths of 4, 5, and 6 cm at 10 and 15 MeV. Results showed that off-axis dose at the ends of arc (without skin collimation) agreed to within 2% in the low-dose gradient region and to within 1.2 mm in the high-dose gradient region. This work showed that the accuracy of the PBRA arced-beam dose model met the criteria specified by Van Dyk et al. [Int. J. Radiat. Oncol. Biol. Phys. 26, 261-273 (1993)] with the exception of the buildup region of the 15 MeV beam. Based on the present results, results of a previous study showing acceptable accuracy in the presence of skin collimation, and results of a previous study showing acceptable accuracy in the presence of internal heterogeneities, it is concluded that the PBRA arced-beam dose model should be adequate for planning electron arc therapy.

Algorithms↗

A novel platform simulating irregular motion to enhance assessment of respiration-correlated radiation therapy procedures.

Respiratory motion continues to present challenges in the delivery of radiation therapy to tumors in the thorax and abdomen by causing movement of structures within those areas. Several approaches to account for this movement in the planning and delivery of treatment have been developed over the past several years. To assist in the development and assessment of various techniques for respiration-correlated radiation therapy, a platform capable of programmable irregular longitudinal motion has been designed and fabricated to simulate intrafractional respiratory motion. A sliding platform and the base on which it was mounted were constructed from polycarbonate plastic, and a stepper motor provided platform motion. Respiratory motion data, either artificially generated on a spreadsheet or extracted from respiratory monitoring files, were converted to a format appropriate for driving the stepper motor. Various phantoms were placed on top of the platform and used in studies related to respiration-correlated radiation therapy. Several applications of the platform were demonstrated, such as improving the quality of acquisition of time-dependent computed tomography image datasets, comparing various methods of acquiring such datasets, and implementing feedback-guided breath hold treatment delivery procedures. This study showed that a platform capable of programmable irregular motion is a useful tool for the development and assessment of procedures related to the effects of respiratory motion in radiation therapy.

Artifacts↗

Respiration-correlated treatment delivery using feedback-guided breath hold: a technical study.

Respiratory motion causes movement of internal structures in the thorax and abdomen, making accurate delivery of radiation therapy to tumors in those areas a challenge. To reduce the uncertainties caused by this motion, we have developed feedback-guided breath hold (FGBH), a novel delivery technique in which radiation is delivered only during a voluntary breath hold that is sustained for as long as the patient feels comfortable. Here we present the technical aspects of FGBH, which involve (1) fabricating the hardware so the respiratory trace can be displayed to the patient, (2) assembling a delay box to be used as a breath-hold detector, and (3) performing quality control tests to ensure that FGBH can be delivered accurately and safely. A commercial respiratory tracking system that uses an external fiducial to monitor abdominal wall motion generates and displays the breathing trace and specific positions in the breathing cycle where a breath hold needs to occur. Hardware was developed to present this display to the patient in the treatment position. Patients view the presentation either on a liquid crystal display or through a pair of virtual reality goggles. Using the respiratory trace as a visual aid, the patient performs a breath hold so that the position representing the location of a fiducial is held within a specified gating window. A delay box was fabricated to differentiate between gating signals received during free breathing and those received during breath hold, allowing radiation delivery only when the fiducial was within the breath-hold gating window. A quality control analysis of the gating delay box and the integrated system was performed to ensure that all of the hardware and components were ready for clinical use.

Abdomen↗

Semiautomated four-dimensional computed tomography segmentation using deformable models.

The purpose of this work is to demonstrate a proof of feasibility of the application of a commercial prototype deformable model algorithm to the problem of delineation of anatomic structures on four-dimensional (4D) computed tomography (CT) image data sets. We acquired a 4D CT image data set of a patient's thorax that consisted of three-dimensional (3D) image data sets from eight phases in the respiratory cycle. The contours of the right and left lungs, cord, heart, and esophagus were manually delineated on the end inspiration data set. An interactive deformable model algorithm, originally intended for deforming an atlas-based model surface to a 3D CT image data set, was applied in an automated fashion. Triangulations based on the contours generated on each phase were deformed to the CT data set on the succeeding phase to generate the contours on that phase. Deformation was propagated through the eight phases, and the contours obtained on the end inspiration data set were compared with the original manually delineated contours. Structures defined by high-density gradients, such as lungs, cord, and heart, were accurately reproduced, except in regions where other gradient boundaries may have confused the algorithm, such as near bronchi. The algorithm failed to accurately contour the esophagus, a soft-tissue structure completely surrounded by tissue of similar density, without manual interaction. This technique has the potential to facilitate contour delineation in 4D CT image data sets; and future evolution of the software is expected to improve the process.

Algorithms↗

Modeling skin collimation using the electron pencil beam redefinition algorithm.

Skin collimation is an important tool for electron beam therapy that is used to minimize the penumbra when treating near critical structures, at extended treatment distances, with bolus, or using arc therapy. It is usually made of lead or lead alloy material that conforms to and is placed on patient surface. Presently, commercially available treatment-planning systems lack the ability to model skin collimation and to accurately calculate dose in its presence. The purpose of the present work was to evaluate the use of the pencil beam redefinition algorithm (PBRA) in calculating dose in the presence of skin collimation. Skin collimation was incorporated into the PBRA by terminating the transport of electrons once they enter the skin collimator. Both fixed- and arced-beam dose calculations for arced-beam geometries were evaluated by comparing them with measured dose distributions for 10- and 15-MeV beams. Fixed-beam dose distributions were measured in water at 88-cm source-to-surface distance with an air gap of 32 cm. The 6 x 20-cm2 field (dimensions projected to isocenter) had a 10-mm thick lead collimator placed on the surface of the water with its edge 5 cm inside the field's edge located at +10 cm. Arced-beam dose distributions were measured in a 13.5-cm radius polystyrene circular phantom. The beam was arced 90 degrees (-45 degrees to +45 degrees), and 10-mm thick lead collimation was placed at +/- 30 degrees. For the fixed beam at 10 MeV, the PBRA- calculated dose agreed with measured dose to within 2.0-mm distance to agreement (DTA) in the regions of high-dose gradient and 2.0% in regions of low dose gradient. At 15 MeV, the PBRA agreed to within a 2.0-mm DTA in the regions of high-dose gradient; however, the PBRA underestimated the dose by as much as 5.3% over small regions at depths less than 2 cm because it did not model electrons scattered from the edge of the skin collimation. For arced beams at 10 MeV, the agreement was 1-mm DTA in the high-dose gradient regions, and 2% in the low-dose gradient regions. For arced beams at 15 MeV, the agreement was 1 mm in the high-dose gradient regions, and in the low-dose gradient region at depth less than 2 cm, as much as 5% dose difference was observed. This study demonstrated the ease with which skin collimation can be incorporated into the PBRA. The good agreement of PBRA calculated with measured dose shows that the PBRA is likely sufficiently accurate for clinical use in the presence of skin collimation for electron arc therapy. To further improve the accuracy of the PBRA in regions having significant electrons scattered from the edge of the skin collimation would require transporting the electrons through the lead skin collimation near its edges.

Algorithms↗

Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part II-margin reduction of internal target volume.

PURPOSE: To analyze the relationship between lung motion and skin surface motion during respiration, determine the uncertainties and variability of such a relationship, and assess the potential of reducing internal target margin for gated radiotherapy. METHODS AND MATERIALS: Three healthy volunteers and four lung cancer patients were recruited in a prospective imaging study using MRI to track the internal lung and external skin motion during breathing. The relationship between the lung and skin motion was modeled using linear regression analysis. The slope of the linear fit and its confidence interval were analyzed for different lung locations, skin surface locations, and breathing patterns from separate imaging sessions. The margins of the internal target volume were calculated based on the residual lung motion during gating and its uncertainties from multiple treatment fractions for the gated treatment. RESULTS: The slope and confidence interval of the linear regression from the motion analysis were uniquely defined by the locations of the lung, skin surface, and breathing patterns. Statistically significant differences were observed among individuals and between different times of measurement. The normal free-breathing motion averaged from all volunteer and patient data was 13.4 +/- 7.4 mm along the superior-inferior (SI) direction and 6.9 +/- 2.6 mm along the anterior-posterior (AP) direction. With simulated respiratory gating, the average margin reduction was 5.5 +/- 4.8 mm and 1.6 +/- 1.0 mm, respectively, along the SI and AP directions (or 36% +/- 15% and 25% +/- 14%, respectively, relative to free-breathing motion). CONCLUSION: Because respiratory movement is rather complex, the relationship between the lung and skin surface motion is affected by many anatomic and physiologic factors. The reduction of internal target margin and efficacy of the free-breathing gating technique should be assessed for individual cases.

Adult↗

Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part I--correlating internal lung motion with skin fiducial motion.

PURPOSE: To measure the internal lung motion due to respiration using magnetic resonance images (MRIs); to evaluate the correlation between lung motion and skin surface motion and the reliability of tracking lung motion with external fiducials. METHODS AND MATERIALS: An MRI protocol using fast gradient-echo sequences was developed to acquire dynamic cine images of the thoracoabdominal region along the axial, sagittal, and coronal planes. The subjects (3 healthy volunteers and 4 lung cancer patients) were instructed to perform normal or altered breathing during MRI. Lung vessels identified on MRI were used as anatomic landmarks for internal lung structures. From sagittal cine MRI scans, the positions of the lung vessels and skin surface were tracked and their movements measured. Correlation between the movements of the external markers and internal structures was then calculated and analyzed. RESULTS: Lung vessel motion in the superior-inferior (SI) direction correlated best with mid-upper abdominal skin surface movement (correlation coefficient, 0.89 +/- 0.09 and 0.87 +/- 0.23 for volunteers and patients, respectively). The anterior-posterior (AP) vessel motion generally correlated poorly with the skin surface movement, with marker placement on the upper chest yielding the strongest results (correlation coefficient, 0.72 +/- 0.23 and 0.44 +/- 0.27 for volunteers and patients, respectively). The strength of the correlation depended on the locations of the tracked vessels, locations of the skin surface, and subjects' breathing patterns. The best correlation was seen between the motion of an abdominal fiducial and SI lung motion. Significant intersubject variability was also observed. CONCLUSION: Movement of an external fiducial may not correlate fully with, or predict, internal lung motion. Effective monitoring of respiration may have to rely on a combination of multiple fiducials and other physiologic parameters, such as lung volume and/or air flow.

Adult↗

Correlation of gross tumor volume excursion with potential benefits of respiratory gating.

PURPOSE: To test the hypothesis that the magnitude of thoracic tumor motion can be used to determine the desirability of respiratory gating. METHODS AND MATERIALS: Twenty patients to be treated for lung tumors had computed tomography image data sets acquired under assisted breath hold at normal inspiration (100% tidal volume), at full expiration (0% tidal volume), and under free breathing. A radiation oncologist outlined gross tumor volumes (GTVs) on the breath-hold computed tomographic images. These data sets were registered to the free-breathing image data set. Two sets of treatment plans were generated: one based on an internal target volume explicitly formed from assessment of the excursion of the clinical target volume (CTV) through the respiratory cycle, representing an ungated treatment, and the other based on the 0% tidal volume CTV, representing a gated treatment with little margin for residual motion. Dose-volume statistics were correlated to the magnitude of the motion of the center of the GTV during respiration. RESULTS: Patients whose GTVs were >100 cm(3) showed little decrease in lung dose under gating. The other patients showed a correlation between the excursion of the center of the GTV and a reduction in potential lung toxicity. As residual motion increased, the benefits of respiratory gating increased. CONCLUSION: Gating seems to be advantageous for patients whose GTVs are <100 cm(3) and for whom the center of the GTV exhibits significant motion, provided residual motion under gating is kept small.

Humans↗

Dosimetric uncertainties of three-dimensional dose reconstruction from two-dimensional data in a multi-institutional study.

Inconsistencies in the treatment planning process leading to dosimetric uncertainties may affect conclusions drawn from interinstitutional radiation oncology clinical trials. The purpose of this study was to assess the dosimetric uncertainties resulting from the process of reconstructing three-dimensional dose distributions from two-dimensional treatment plan information provided by participating institutions in a randomized clinical trial. This study was based on American College of Radiology Protocol #427, Locally Advanced Multi-Modality Protocol; a multi-institutional phase II randomized study involving radiation therapy for patients with inoperable non-small cell lung cancer. Several sources of dosimetric uncertainty were identified and analyzed, including image quality of hard-copy computed tomography (CT) images, slice spacing of CT scans, treatment position, interpretations of target volumes by radiation oncologists, the contouring of normal anatomic structures, and the use of common beam models for all dose calculations. Each source of uncertainty was investigated using a set of plans, with the ideal characteristics of digital images with 3-mm axial slice spacing and a flat couch, consisting of eight cases from Vanderbilt University Medical Center with electronically transferred CT data. The target volume DVH values were dependent on the additional uncertainty introduced by differences in delineation of the target volumes by the participating radiation oncologists. The DVH values for the lungs and heart were dependent on image quality and treatment position. Esophagus DVH values were not dependent on any of the sources of uncertainty. None of the structure DVH values were dependent on slice thickness or variations in the contouring of normal anatomic structures. Reconstruction of three-dimensional dose distributions from two-dimensional treatment plan information may be useful in cases for which digital CT data is not available or for historical data review. However, dosimetric accuracy will depend on image quality of the treatment planning CT data and consistency in the delineation of tumor volumes.

Body Burden↗

Quality assurance evaluation of delivery of respiratory-gated treatments.

We describe a method for evaluating the quality of respiratory-gated radiation delivery using a commercially available device. During irradiation, gating traces for one field for each treatment were extracted from the system for each of 14 patients. The data were then transferred to a spreadsheet. Software was developed to evaluate the following parameters: duty cycle, amplitude of fiducial motion, fraction of amplitude of motion during gated delivery, and respiratory cycle time. Criteria were established for acceptability of gating traces. In our sample, over 85% of the traces indicated acceptability. An example of results for one patient extracted from analyzed gating traces is as follows: mean duty cycle, 57%, average amplitude of motion, 0.89 cm, average fraction of motion during gated delivery, 0.45; mean respiratory cycle time, 4.5 s. This technique can be used to evaluate delivery of respiratory-gated radiation therapy for quality assurance purposes and to assess various techniques for improving delivery of gated therapy. A hardcopy of the gating traces can be used to document gated treatment delivery for potential billing of the gated delivery process.

Artifacts↗

Dosimetric benefits of respiratory gating: a preliminary study.

In this study, we compared the amount of lung tissue irradiated when respiratory gating was imposed during expiration with the amount of lung tissue irradiated when gating was imposed during inspiration. Our hypothesis was that the amount of lung tissue spared increased as inspiration increased. Computed tomography (CT) image data sets were acquired for 10 patients who had been diagnosed with primary bronchogenic carcinoma. Data sets were acquired during free breathing and during breath-holds at 0% tidal volume and 100% tidal volume, and, when possible, at deep inspiration, corresponding to approximately 60% vital capacity. Two treatment plans were developed on the basis of each of the gated data sets: one in which the treatment portals were those of the free-breathing plan, and the other in which the treatment portals were based on the gated planning target volumes. Dose-mass histograms of the lungs calculated at 0% tidal volume were compared to those calculated at deep inspiration and at 100% tidal volume. Data extracted from the dose-mass histograms were used to determine the most dosimetrically beneficial point to gate, the reduction in the amount of irradiated lung tissue that resulted from gating, and any disease characteristics that might predict a greater need for gating. The data showed a reduction in the mass of normal tissue irradiated when treatment portals based on the gated planning target volume were used. More normal lung tissue was spared at deep inspiration than at the other two gating points for all patients, but normal lung tissue was spared at every point in the respiratory cycle. No significant differences in the amount of irradiated tissue by disease characteristic were identified. Respiratory gating of thoracic radiation treatments can often improve the quality of the treatment plan, but it may not be possible to determine which patients may benefit from gating prior to performing the actual treatment planning.

Artifacts↗

Heterogeneous planning for homogeneous protocols.

Clinical trials often require homogeneous treatment plans. Many institutions, however, have begun using heterogeneous plans. Is it possible to satisfy the requirements of such a protocol while achieving the superior accuracy of heterogeneous treatment planning? At the University of Texas M. D. Anderson Cancer Center, we currently use conformal treatment planning with heterogeneities for thoracic cancers. This paper describes a procedure that has been developed to satisfy the requirements of a homogeneous protocol, such as RTOG 98-01 (A Phase III Study of Amifostine mucosal protection), while maintaining accuracy in treatment planning.

Amifostine↗

Hazards of dose escalation in prostate cancer radiotherapy.

PURPOSE: To assess the benefit of escalating the dose in definitive prostate cancer radiotherapy vs. the associated risk of complications. MATERIALS AND METHODS: Between 1987 and 1999, 1087 patients with clinical Stage T1b-T3 adenocarcinoma of the prostate were definitively irradiated without hormonal therapy and had a pretreatment serum prostate-specific antigen (PSA) and Gleason score recorded. The median follow-up was 65 months. Doses ranged from 64 to 78 Gy, with the treatment techniques corresponding to the year of therapy and the prescribed dose. A total of 301 patients were treated on a randomized protocol to either 70 or 78 Gy. Also, 163 patients were treated with three-dimensional conformal therapy and had dose-volume histograms available for review. RESULTS: Tumor stage, grade, pretreatment PSA level, and radiation dose were all independent predictors of PSA disease-free survival (PSA-DFS) in multivariate analysis. The hazard rate for biochemical failure peaked at 1.5-3 years after radiotherapy. Although a statistically significant dose effect on PSA-DFS was found in the pretreatment PSA levels of those with both < or =10 ng/mL and >10 ng/mL, in those with a pretreatment PSA < or =10 ng/mL, the improvement in outcome was only seen going from a dose level of 64-66 Gy to 68-70 Gy with a 5-year PSA-DFS rate of 66% vs. 81% (p <0.0001). This was also confirmed by the data from the randomized patients who showed no difference in outcome whether treated to 70 Gy or 78 Gy. In patients with a pretreatment PSA level >10 ng/mL, a statistically significant improvement was found in disease-free outcome among the 64-66-Gy, 68-70-Gy, and 78-Gy levels. PSA-DFS was approximately 50% better at each higher dose level at 5 and 8 years after treatment. The dose had a statistically significant impact in both intermediate- and high-risk groups. Rectal morbidity was both dose and volume related. Although at 5 years after therapy, the Grade 2-3 rectal complication rate was twice as high for patients treated to 78 Gy than to 70 Gy, 26% vs. 12%, this risk could be markedly diminished by adhering to dose-volume constraints. CONCLUSIONS: In intermediate- and high-risk prostate cancer patients, although it appears that radiation-dose escalation may improve PSA-DF outcome, the price paid in treatment morbidity can be high without adequate attention to dose-volume constraints of normal tissue. Care must be taken to consider not only the hazard of tumor recurrence but also that of complications.

Adenocarcinoma↗

Treatment planning for lung cancer: traditional homogeneous point-dose prescription compared with heterogeneity-corrected dose-volume prescription.

PURPOSE: To quantify the differences in doses to target volumes and critical thoracic structures calculated by traditional homogeneous point-dose prescription and heterogeneity-corrected volume-dose prescription. METHODS AND MATERIALS: Between 1998 and 2001, 30 patients with inoperable Stage I/II non-small-cell lung cancer underwent radiation treatment planning at our institution. A commercially available convolution/superposition- based algorithm was used. Three treatment plans were calculated for each patient using identical beam geometries: one plan was generated by traditional homogeneous point-dose prescription, a second by the traditional method with heterogeneity correction, and a third by heterogeneity-corrected volume-dose prescription that would cover 95% of the planned target volume (PTV). Target volume coverage, isocenter dose, and dose uniformity in the second and third plans were compared. RESULTS: The PTV, clinical target volume (CTV), and isocenter calculated by the heterogeneity-corrected volume-dose method were equivalent to those calculated by the traditional homogeneous point-dose method with heterogeneity correction. The fraction of the PTV covered by heterogeneity-corrected volume-dose prescription was significantly greater than the fraction covered by traditional homogeneous point-dose prescription with heterogeneity correction (p = 0.05). The dose prescribed using the traditional method would have been delivered to less than 90% of the PTV in 14 of 30 patients. There was no significant difference in the maximum and minimum doses to the PTV, the CTV, or the isocenter calculated by the traditional homogeneous method with heterogeneity correction and the heterogeneity-corrected volume-dose method. There was also no significant difference in the planned volume of lung receiving greater than 20 Gy as calculated by these two methods. CONCLUSION: When compared with traditional homogeneous radiation treatment planning, heterogeneity-corrected methods produce equivalent PTV, CTV, and isocenter doses while providing superior PTV coverage.

Carcinoma, Non-Small-Cell Lung↗

Effects of radiotherapy and chemotherapy on lung function in patients with non-small-cell lung cancer.

PURPOSE: To evaluate the effects of chemoradiation on objective tests of pulmonary function. MATERIALS AND METHODS: One hundred lung cancer patients treated in five protocols between 1992 and 2000 with combinations of thoracic radiotherapy (RT) and chemotherapy were evaluated with pre- and post-RT pulmonary function tests. The pulmonary function tests were analyzed for changes in measures of obstruction (forced expiratory volume in 1 s per unit of vital capacity [FEV(1)/VC]), restriction (total lung capacity [TLC]), and diffusing capacity (diffusing capacity for carbon monoxide [DLCO]). The use and timing of chemotherapy and RT, as well as patient, tumor, and treatment factors, were evaluated using univariate and multivariate analyses. RESULTS: No treatment or patient factors were significantly associated with changes in FEV(1)/VC. Chemotherapy with RT, compared with RT alone, was associated with a lower post-RT TLC (92% vs. 107%, p = 0.002). Nodal status (N2-N3 vs. N1), tumor location (central vs. peripheral), use of >/=6 treatment fields, and tumor volume >/=100 cm(3) were also associated with a significantly lower post-RT TLC. On univariate analysis, the use of any chemotherapy (p = 0.029) and the use of concurrent vs. sequential chemotherapy (p = 0.028) were predictive of a lower post-RT DLCO. Patient age >/=60 years, nodal status (N2-N3 vs. N0-N1), tumor volume >/=100 cm(3), tumor location (central vs. peripheral), and use of >/=6 treatment fields were also associated with a significantly lower post-RT DLCO. The fractional volume of irradiated normal lung correlated with the decrease in DLCO (p <0.001), with a 1.3% DLCO decline for each 1% of total lung volume that received >20 Gy. CONCLUSIONS: The addition of chemotherapy to RT significantly exacerbates the post-RT decrease in TLC and DLCO. The greatest decrease in DLCO occurs in patients treated with concurrent chemoradiation.

Adult↗