Search PubMed⌕ Search

Biomedical subjects

George P Anderson

Publications and source records attributed to George P Anderson.

7 recordsLinked to original sources

Analysis of aqueous 2,4,6-trinitrotoluene (TNT) using a fluorescent displacement immunoassay.

We report a rapid, simple, and sensitive assay that is potentially amenable to high throughput screening for analysis of 2,4,6-trinitrotoluene (TNT) present in aqueous solutions. The assay is based on the change in fluorescence emission intensity of a fluorescently labeled TNT analogue pre-bound to an anti-TNT antibody that occurs upon its competitive displacement by TNT. The assay can be performed in both cuvette- and 96-well plate-based formats. TNT at a level of 0.5 micro g L(-1) (0.5 ppb) was detected in phosphate buffered saline; detection improved to 0.05 micro g L(-1) (0.05 ppb) for TNT dissolved in artificial seawater.

Antibodies↗

2,4,6-Trinitrotoluene detection using recombinant antibodies.

The ability to detect low levels of 2,4,6-trinitrotoluene (TNT) in aqueous samples is important due to the toxicity of both TNT and its breakdown products. We have been characterizing recombinant anti-TNT antibodies isolated from the Griffin library of phage displayed scFvs by selection for binders to the TNT-surrogate 2,4,6-trinitrobenzene (TNB) coupled to the protein bovine serum albumin. Two candidate antibody fragments, TNB1 and TNB2, were isolated and evaluated by ELISA for their ability to bind to TNB coupled to the protein ovalbumin. Competition ELISA was then used to demonstrate antibody fragment binding to TNT in solution and to examine cross-reactivity towards several TNT-related compounds and other explosives. Both recombinant antibody fragments were incorporated into a continuous flow assay for the detection of TNT. TNB2, the best single chain antibody, showed a limit of detection of 1 ng ml(-1), comparable to a commercially available anti-TNT antibody in the same assay format.

Animals↗

Improved fluoroimmunoassays using the dye Alexa Fluor 647 with the RAPTOR, a fiber optic biosensor.

The performance of the fluorescent dye Alexa Fluor 647 (AF647) was explored as an alternative to Cy5 for immunoassays on the RAPTOR, a fiber optic biosensor. The RAPTOR performs sandwich fluoroimmunoassays on the surface of small polystyrene optical waveguides for analyte detection. Fluorescence and immunoassay data were examined at various dye-to-protein (D/P) ratios for both Cy5 and Alexa Fluor 647. Primarily, due to the self-quenching characteristics of Cy5, Alexa Fluor 647 is substantially more effective in fluoroimmunoassays, yielding over twice the signal for any given analyte concentration. Alexa Fluor 647 can be attached to antibodies at higher ratios, D/P=6, before self-quenching begins to limit the dye's effectiveness. Furthermore, while Alexa Fluor 647 becomes quenched at high dye-to-protein ratios, D/P=9, the net fluorescence yield reaches a maximum, as opposed to Cy5-labeled proteins, which become nearly nonfluorescent at high labeling ratios, D/P> or =6. The limitations of Cy5 were elucidated with an immunoassay for ricin, while the advantages of Alexa Fluor 647 were demonstrated in both direct binding assays as well as in a sandwich immunoassay for staphylococcal enterotoxin B.

Antibodies↗

Nine-analyte detection using an array-based biosensor.

A fluorescence-based multianalyte immunosensor has been developed for simultaneous analysis of multiple samples. While the standard 6 x 6 format of the array sensor has been used to analyze six samples for six different analytes, this same format has the potential to allow a single sample to be tested for 36 different agents. The method described herein demonstrates proof of principle that the number of analytes detectable using a single array can be increased simply by using complementary mixtures of capture and tracer antibodies. Mixtures were optimized to allow detection of closely related analytes without significant cross-reactivity. Following this facile modification of patterning and assay procedures, the following nine targets could be detected in a single 3 x 3 array: Staphylococcal enterotoxin B, ricin, cholera toxin, Bacillus anthracis Sterne, Bacillus globigii, Francisella tularensis LVS, Yersiniapestis F1 antigen, MS2 coliphage, and Salmonella typhimurium. This work maximizes the efficiency and utility of the described array technology, increasing only reagent usage and cost; production and fabrication costs are not affected.

Antigens↗

Detection of 2,4,6-trinitrotoluene in seawater using a reversed-displacement immunosensor.

Reported in this study are the experimental design and results of an immunosensor for the detection of the explosive, 2,4,6-trinitrotoluene (TNT) in seawater using a reversed-displacement format. This reversed-displacement immunosensor methodology has successfully measured TNT in seawater by direct injection, eliminating the need for preconcentration or pretreatment of samples. A microcolumn containing an Affi-Gel resin derivatized with a 2,4,6-trinitrobenzene (TNB) moiety and a fluorophore-labeled anti-TNT antibody composed the immunoassay reactive chamber. Fluorophore-labeled anti-TNT antibody was incubated with the modified Affi-Gel resin until binding equilibrium was reached. Under a constant flow, samples containing TNT were introduced into the flow stream displacing the fluorophore-labeled TNT antibody. Limits of detection were 2.5ng/mL or part-per-billion (ppb) for TNT in saline buffer and 25ppb in seawater with an analysis time of 10 min. Two anti-TNT antibodies with differing binding affinities were compared in the reversed-displacement assay format, and a correlation between affinity and detection limits was observed. Furthermore, we have demonstrated that the reversed-displacement format can be used to screen seawater samples containing TNT, remains effective after dozens of cycles, and provides significant fluorescence response before regeneration is required.

Antibodies, Monoclonal↗

Avidin: a natural bridge for quantum dot-antibody conjugates.

We describe the preparation and characterization of bioinorganic conjugates in which luminescent semiconductor CdSe-ZnS core-shell nanocrystal quantum dots (QDs) were coupled to antibodies through the use of an avidin bridge adsorbed to the nanocrystal surface via electrostatic self-assembly. Avidin, a highly positively charged protein, was found to adsorb tightly to QDs modified with dihydrolipoic acid, which gives their surface a homogeneous negative charge. QD conjugation to biotinylated antibodies subsequently is readily achieved. Fluoroimmunoassays utilizing these antibody conjugated QDs were successful in the detection of protein toxins (staphylococcal enterotoxin B, cholera toxin). QD-antibody conjugates formed in such a facile manner permit their use as a common immuno reagent, and in the development of multianalyte detection.

Antibodies↗

Conjugation of luminescent quantum dots with antibodies using an engineered adaptor protein to provide new reagents for fluoroimmunoassays.

We describe the preparation and characterization of bioinorganic conjugates made with highly luminescent semiconductor CdSe-ZnS core-shell quantum dots (QDs) and antibodies for use in fluoroimmunoassays. The conjugation strategy employs an engineered molecular adaptor protein, attached to the QDs via electrostatic/hydrophobic self-assembly, to link the inorganic fluorophore with antibodies. In this method, the number of antibodies conjugated to a single QD can be varied. In addition, we have developed a simple purification strategy based on mixed-composition conjugates of the molecular adaptor and a second two-domain protein that allows the use of affinity chromatography. QD-antibody conjugates were successfully used in fluoroimmunoassays for detection of both a protein toxin (staphylococcal enterotoxin B) and a small molecule (2,4,6-trinitrotoluene).

Amino Acid Sequence↗