Search PubMed⌕ Search

Biomedical subjects

George David

Publications and source records attributed to George David.

2 recordsLinked to original sources

Mammographic x-ray unit kilovoltage test tool based on k-edge absorption effect.

A simple tool to determine the peak kilovoltage (kVp) of a mammographic x-ray unit has been designed. Tool design is based on comparing the effect of k-edge discontinuity of the attenuation coefficient for a series of element filters. Compatibility with the mammography accreditation phantom (MAP) to obtain a single quality control film is a second design objective. When the attenuation of a series of sequential elements is studied simultaneously, differences in the absorption characteristics due to the k-edge discontinuities are more evident. Specifically, when the incident photon energy is higher than the k-edge energy of a number of the elements and lower than the remainder, an inflection may be seen in the resulting attenuation data. The maximum energy of the incident photon spectra may be determined based on this inflection point for a series of element filters. Monte Carlo photon transport analysis was used to estimate the photon transmission probabilities for each of the sequential k-edge filter elements. The photon transmission corresponds directly to optical density recorded on mammographic x-ray film. To observe the inflection, the element filters chosen must have k-edge energies that span a range greater than the expected range of the end point energies to be determined. For the design, incident x-ray spectra ranging from 25 to 40 kVp were assumed to be from a molybdenum target. Over this range, the k-edge energy changes by approximately 1.5 keV between sequential elements. For this design 21 elements spanning an energy range from 20 to 50 keV were chosen. Optimum filter element thicknesses were calculated to maximize attenuation differences at the k-edge while maintaining optical densities between 0.10 and 3.00. Calculated relative transmission data show that the kVp could be determined to within +/-1 kV. To obtain experimental data, a phantom was constructed containing 21 different elements placed in an acrylic holder. MAP images were used to determine appropriate exposure techniques for a series of end point energies from 25 to 35 kVp. The average difference between the kVp determination and the calibrated dial setting was 0.8 and 1.0 kV for a Senographe 600 T and a Senographe DMR, respectively. Since the k-edge absorption energies of the filter materials are well known, independent calibration or a series of calibration curves is not required.

Absorption↗

Web-based X-ray quality control documentation.

The department of radiology at the Medical College of Georgia Hospital and Clinics has developed an equipment quality control web site. Our goal is to provide immediate access to virtually all medical physics survey data. The web site is designed to assist equipment engineers, department management and technologists. By improving communications and access to equipment documentation, we believe productivity is enhanced. The creation of the quality control web site was accomplished in three distinct steps. First, survey data had to be placed in a computer format. The second step was to convert these various computer files to a format supported by commercial web browsers. Third, a comprehensive home page had to be designed to provide convenient access to the multitude of surveys done in the various x-ray rooms. Because we had spent years previously fine-tuning the computerization of the medical physics quality control program, most survey documentation was already in spreadsheet or database format. A major technical decision was the method of conversion of survey spreadsheet and database files into documentation appropriate for the web. After an unsatisfactory experience with a HyperText Markup Language (HTML) converter (packaged with spreadsheet and database software), we tried creating Portable Document Format (PDF) files using Adobe Acrobat software. This process preserves the original formatting of the document and takes no longer than conventional printing; therefore, it has been very successful. Although the PDF file generated by Adobe Acrobat is a proprietary format, it can be displayed through a conventional web browser using the freely distributed Adobe Acrobat Reader program that is available for virtually all platforms. Once a user installs the software, it is automatically invoked by the web browser whenever the user follows a link to a file with a PDF extension. Although no confidential patient information is available on the web site, our legal department recommended that we secure the site in order to keep out those wishing to make mischief. Our interim solution has not been to password protect the page, which we feared would hinder access for occasional legitimate users, but also not to provide links to it from other hospital and department pages. Utility and productivity were improved and time and money were saved by making radiological equipment quality control documentation instantly available on-line.

Computer Security↗