Search PubMed⌕ Search

Biomedical subjects

Garry E Gold

Publications and source records attributed to Garry E Gold.

42 records · Page 3Linked to original sources

Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation.

OBJECTIVE: To obtain high-quality high-resolution images of articular cartilage with reduced imaging time, we combined a novel technique of generalized multipoint fat-water separation with three-dimensional (3D) steady-state free precession (SSFP) imaging. SUBJECTS AND METHODS: The cartilage of 10 knees in five healthy volunteers was imaged with 3D SSFP imaging and a multipoint fat-water separation method capable of separating fat and water with short TE increments. Fat-saturated 3D spoiled gradient-echo (SPGR) images were obtained for comparison. RESULTS: High-quality images of the knee with excellent fat-water separation were obtained with 3D SSFP imaging. Total imaging time required was 58% less than that required for 3D SPGR imaging with a comparable cartilage signal-to-noise ratio and spatial resolution. Unlike 3D SPGR images, 3D SSFP images exhibited bright synovial fluid, providing a potential arthrographic effect. CONCLUSION: High-quality high-resolution images of articular cartilage with improved fat-water separation, bright synovial fluid, and markedly reduced acquisition times can be obtained with 3D SSFP imaging combined with a fat-water separation technique.

Adult↗

MR imaging of knee cartilage with FEMR.

OBJECTIVE: Fluctuating equilibrium magnetic resonance (FEMR) is a rapid three-dimensional (3D) imaging sequence with high signal-to-noise ratio (SNR). FEMR may be useful for detecting cartilage defects in the knee. At 1.5 T, FEMR uses a TR with odd multiples of 2.2 ms for fat/water separation. With a TR of 6.6 ms, high-resolution 3D imaging of cartilage is possible. DESIGN AND PATIENTS: The knees of 10 volunteers and two patients were imaged on a GE Signa 1.5 T scanner using an extremity coil. Scans were preceded by a shimming sequence optimizing linear terms. Subjects were imaged with FEMR, proton-density fast spin-echo (PD-FSE), T2-weighted fast spin-echo (T2-FSE), and 3D fat-suppressed spoiled-gradient-recalled echo (3D-SPGR). RESULTS: SNR and contrast-to-noise efficiency measurements for cartilage using FEMR were superior to those using PD-FSE, T2-FSE, and 3D-FS-SPGR. FSE images showed bright synovial fluid with limited cartilage detail. 3D-SPGR had comparable resolution to FEMR but suboptimal cartilage/fluid contrast and longer scan times (8 min versus 2 min). Cartilage surface detail, outlined by bright synovial fluid, was best seen on the FEMR images. DISCUSSION: FEMR obtains high-resolution 3D images of the entire knee in 2 min with excellent cartilage/fluid contrast. FEMR is sensitive to field inhomogeneity and requires shimming. Surface defects are outlined by bright synovial fluid, and cartilage has higher signal-to-noise efficiency compared with PD-FSE, T2-FSE, and 3D-SPGR techniques.

Cartilage, Articular↗

Short echo time MR spectroscopic imaging of the lung parenchyma.

PURPOSE: To perform short echo time MR spectroscopic imaging of the lung parenchyma on normal volunteers. MATERIALS AND METHODS: A short echo time projection-reconstruction spectroscopic imaging sequence was implemented on a commercial 1.5T whole body MRI scanner. Images and spectra of the lung parenchyma were obtained from five normal volunteers. Breath-held spectroscopic imaging was also performed. RESULTS: Spectroscopic imaging of short-T2* species allows visualization of different anatomic structures based upon their frequency shifts. A characteristic peak from the parenchyma was seen at three ppm from water frequency. CONCLUSION: Short echo time MR spectroscopic imaging of the lung parenchyma was demonstrated in normal volunteers. This method may improve proton imaging of the lungs and add specificity to the diagnosis of pulmonary disease.

Adult↗

In vivo motion of the rectus femoris muscle after tendon transfer surgery.

Rectus femoris transfer surgery is performed to convert the rectus femoris muscle from a knee extensor to a knee flexor. In this surgery, the distal tendon of the rectus femoris is detached from the patella and reattached to one of the knee flexor tendons. The outcomes of this procedure are variable, and it is not known if the surgery successfully converts the muscle to a knee flexor. We measured the motion of muscle tissue within the rectus femoris and vastus intermedius during knee extension in 10 unimpaired control subjects (10 limbs) and 6 subjects (10 limbs) after rectus femoris transfer using cine phase-contrast magnetic resonance imaging. Displacements of the vastus intermedius during knee extension were similar between control and tendon transfer subjects. In the control subjects, the rectus femoris muscle consistently moved in the direction of the knee extensors and displaced more than the vastus intermedius. The rectus femoris also moved in the direction of the knee extensors in the tendon transfer subjects; however, the transferred rectus femoris displaced less than the vastus intermedius. These results suggest that the rectus femoris is not converted to a knee flexor after its distal tendon is transferred to the posterior side of the knee, but its capacity for knee extension is diminished by the surgery.

Adolescent↗

In vivo anatomy of the Neer and Hawkins sign positions for shoulder impingement.

The Neer and Hawkins impingement signs are commonly used to diagnose subacromial pathology, but the anatomy of these maneuvers has not been well elucidated in vivo. This 3-dimensional open magnetic resonance imaging study characterized shoulder anatomy and rotator cuff impingement in 8 normal volunteers placed in the Neer and Hawkins positions. Subacromial and intraarticular contact of the rotator cuff was graded, and minimum distances were computed between the tendon insertion sites and the glenoid, acromion, and coracoid. Both the Neer and Hawkins maneuvers significantly decreased the distance from the supraspinatus insertion to the acromion and posterior glenoid and from the subscapularis insertion to the anterior glenoid. However, the Hawkins position resulted in significantly greater subacromial space narrowing and subacromial rotator cuff contact than the Neer position. In the Hawkins position, subacromial contact of the supraspinatus and infraspinatus was observed in 7 of 8 and 5 of 8 subjects, respectively. In contrast, rotator cuff contact with the acromion did not occur in any subject in the Neer position. Intraarticular contact of the supraspinatus with the posterosuperior glenoid was observed in all subjects in both positions. Subscapularis contact with the anterior glenoid was also seen in 7 of 8 subjects in the Neer position and in all subjects in the Hawkins position. This extensive intraarticular contact suggests that internal impingement may play a role in the Neer and Hawkins signs.

Adult↗

What's new in cartilage?

Magnetic resonance (MR) imaging of articular cartilage is important in evaluation of new surgical and pharmacologic treatments for cartilage damage. Many techniques exist for MR imaging of articular cartilage. Standard techniques for morphologic imaging of cartilage include fast spin-echo and spoiled gradient-echo imaging. These methods provide high-resolution morphologic images of cartilage but are time-consuming in the clinical setting. New methods for faster or higher-resolution morphologic imaging include techniques based on steady-state free precession imaging. These fast techniques will allow detailed evaluation of cartilage in the routine clinical setting. There are also several MR imaging methods that may provide information about the structure and physiology of cartilage. Physiologic imaging may allow detailed evaluation of the glycosaminoglycan matrix or collagen network of articular cartilage and may be the most sensitive method for detection of early changes. With the development of new therapies for osteoarthritis and cartilage injury, MR imaging of articular cartilage is of increasing clinical importance. MR imaging will play an important role in evaluation of the effectiveness of these therapies.

Cartilage Diseases↗