Search PubMed⌕ Search

Biomedical subjects

Gareth Jenkins

Publications and source records attributed to Gareth Jenkins.

3 recordsLinked to original sources

Shear-driven pumping and Fourier transform detection for on chip circular chromatography applications.

A circular, shear-driven pumping system combined with Fourier Transform detection has been developed for the application of chip based cyclic chromatography. Using this system, it is possible to perform an injection of a sample plug into a circular micro-channel and then drive the sample through the channel, using shear flow induced by a rotation stage. High pumping rates at uniform speeds are attainable with this system with very little heat production. Typical pumping rates of up to 1.423 mm s(-1) +/- 2 microm s(-1) were used in experiments although much higher rates >14 mm s(-1) are also possible with this system. Fluorescence detection was used to detect a sample plug of Coumarin dyes, flowing around the channel. A coating of porous polymethacrylate was used to immobilise RP-HPLC beads onto the glass surface and was applied to the glass micro-channel by selective photopolymerisation. This coating acted as a stationary phase and differences in retention time were observed for an injection of Coumarin dyes for different methanol-water, mobile phase ratios. Full sample retention occurred for 30 : 70 (v/v) methanol-water whereas no retention occurred for 92 : 8 (v/v) methanol-water which can be expected for such a reverse phase, open tubular system. Fourier transform detection applied to the fully retained and non-retained cases showed frequency domain data from a single detection point corresponding to that which may be expected from shear flow theory.

Journal Article↗

Direct optical emission spectroscopy of liquid analytes using an electrolyte as a cathode discharge source (ELCAD) integrated on a micro-fluidic chip.

Atomic emission detection of metallic species in aqueous solutions has been performed using a miniaturised plasma created within a planar, glass micro-fluidic chip. Detection was achieved using an Electrolyte as a Cathode Discharge source (ELCAD) in which the sample solution itself is used as the cathode for the discharge. To realise the ELCAD technique within a micro-fluidic device, a parallel liquid-gas flow was set up in a micro-channel and a glow discharge ignited between the flowing liquid sample surface and a metal wire anode. The detection of copper and sodium was achieved, using atmospheric pressure air as a carrier gas, by observation of atomic emission lines of copper at 324 nm, 327 nm, 511 nm, 515 nm and 522 nm and an atomic emission line of sodium at 589 nm using a commercially available miniaturised spectrometer. A total electrical power of less than 70 mW was required to sustain the discharge. A semi-quantitative, absolute detection limit of 17 nmol s(-1) was obtained for sodium with a sample flow rate of 100 microL min(-1) and an integration time of 100 ms in air at atmospheric pressure. The volume required for such detection is approximately 170 nL. Further analysis was performed with an Echelle spectrometer using both argon and air as a carrier gas. The geometry and flow rates used demonstrate the feasibility of integrating such micro-plasmas into other micro-fluidic devices, such as miniaturised CE devices, as a method of detection. The potential for using such micro-plasmas within highly portable miniaturised systems and mu-TAS devices is presented and discussed.

Journal Article↗

Implant failure.

Explore the source record for details and available documents.

Dental Implantation, Endosseous↗