Automation and optimization of liquid-phase microextraction by gas chromatography.

Several fully automated liquid-phase microextraction (LPME) techniques, including static headspace LPME (HS-LPME) (a drop of solvent is suspended at the tip of a microsyringe needle and exposed to the headspace of the sample solution), exposed dynamic HS-LPME (the solvent is exposed in the headspace of sample vial for different time, and then withdrawn into the barrel of the syringe. This procedure is repeated a number of times), unexposed dynamic HS-LPME (the solvent is moved inside the needle and the barrel of a syringe, and the gaseous sample is withdrawn into the barrel and then ejected), static direct-immersed LPME (DI-LPME) (a drop of solvent is suspended at the tip of a microsyringe needle and directly immersed into the sample solution), dynamic DI-LPME (the solvent is moved inside the needle and the barrel of a syringe, and the sample solution is withdrawn and ejected), and two phase hollow fiber-protected LPME (HF-LPME) (a hollow fiber is used to stabilize and protect the solvent), auto-performed with a commercial CTC CombiPal autosampler, are described in this paper. Critical experimental factors, including temperature, choice of extraction solvent, solvent volume, plunger movement rate, and extraction time were investigated. Among the three HS-LPME techniques that were evaluated, the exposed dynamic HS-LPME technique provided the best performance, compared to the unexposed dynamic HS-LPME and static HS-LPME approaches. For DI-LPME, the dynamic process can enhance the extraction efficiency and the achieved method precision is comparable with the static DI-LPME technique. The precision of the fully automated HF-LPME is quite acceptable (RSD values below 6.8%), and the concentration enrichment factors are better than the DI-LPME approaches. The fully automated LPME techniques are more accurate and more convenient, and the reproducibility achieved eliminates the need for an internal standard to improve the method precision.

Chemistry Techniques, Analytical↗

Time-weighted average water sampling with a diffusion-based solid-phase microextraction device.

A new diffusion-based solid-phase microextraction (SPME) time-weighted average (TWA) field water sampling device was developed and investigated by field trial. The sampler is constructed with copper tube and caps and a commercial SPME fiber assembly. The device possesses all advantages of SPME; it is solvent-free, reusable, combines sampling, isolation and enrichment into one step, and the fiber can be directly injected into a gas chromatograph for analysis with a commercial SPME fiber holder, without further treatment. Field trials in Laurel Creek (Waterloo, Ont., Canada) and Hamilton Harbour (Hamilton, Ont., Canada) illustrated that the device is durable, easy to deploy, and the mass uptake of the device is independent of the face velocity. The device provides good precision [relative standard deviations (RSDs) are less than 20%] and the data obtained with this device are quite comparable to those obtained with the spot sampling method, which demonstrates that the newly developed SPME water sampling device is suitable for long-term monitoring of organic pollutants in water.

Diffusion↗

Kinetic calibration for automated hollow fiber-protected liquid-phase microextraction.

Recently, a kinetic calibration method was developed for the quantification of microextraction. In this study, we proved that the sample volume and sampling time do not affect the feasibility of the calibration method, theoretically. The new theoretical considerations of the kinetic calibration method were validated through the investigation of the kinetics of the absorption and desorption processes of hollow fiber-protected liquid-phase microextractrion (HF-LPME). The kinetic calibration method for HF-LPME was successfully used to correct the matrix effects in the carbaryl analysis of a red wine sample. This research extends the kinetic calibration approach to fast sampling and some in-vial analyses, whereby the sample volume is not much larger than the product of the distribution coefficient and the volume of the extraction phase. HF-LPME technique was successfully automated with a CTC CombiPal autosampler, and a new device was designed for the automation of HF-LPME in this study. All steps of the HF-LPME technique, including the filling of the extraction solvent, sample transfer and agitation, withdrawing the solvent to a syringe, and introducing the extraction phase into the injector, were automated by a CTC autosampler. The fully automated HF-LPME technique is more convenient and more accurate. The good reproducibility of the fully automated HF-LPME technique eliminates the need for an internal standard to improve the analytical precision. The automated HF-LPME technique can be also used to obtain the distribution coefficient between the sample matrix and the extraction phase. The distribution coefficients of carbaryl and (13)C-carbaryl between 1-octanol and red wine, at 25 degrees C, were obtained with this technique.

Journal Article↗

On-rod standardization technique for time-weighted average water sampling with a polydimethylsiloxane rod.

In this study, a polydimethylsiloxane (PDMS) rod was developed as a passive sampler, based on the solid-phase microextraction (SPME) technique. The on-rod standardization technique was applied to the PDMS rod passive sampler. Using the desorption of the pre-loaded standard on the PDMS rod to calibrate the absorption of the target analytes allows for the determination of the time-weighted average (TWA) concentrations of pollutants in the aqueous media. The PDMS rod passive sampler with the on-rod standardization technique was tested in the laboratory with a flow-through system and was subsequently applied to measure TWA concentrations of polycyclic aromatic hydrocarbons (PAHs) in the field (Hamilton Harbour, Hamilton, Ont., Canada). Both the laboratory and field experiments demonstrated that, with the on-rod standardization technique, the PDMS rod can be successfully used as a passive sampler for TWA water sampling in the field. The PDMS rod passive sampler benefits from the inherent advantages of the SPME approach: it incorporates sampling, isolation and enrichment into one step. The design of this system also addressed the additional needs for passive sampling techniques, providing an economical approach to field sampling that is also easy to deploy. Rather, with this approach, TWA concentrations of target analytes can be obtained by one sampler, and can be analyzed directly, with no further sample preparation treatment required.

Chromatography, Liquid↗

SPME in environmental analysis.

Recent advances in the use of solid-phase microextraction (SPME) in environmental analysis, including fiber coatings, derivatization techniques, and in-tube SPME, are reviewed in this article. Several calibration methods for SPME, including traditional calibration methods, the equilibrium extraction method, the exhaustive extraction method, and several diffusion-based calibration methods, are presented. Recent developed SPME devices for on-site sampling and several applications of SPME in environmental analysis are also introduced.

Journal Article↗

Kinetic calibration for automated headspace liquid-phase microextraction.

The kinetics of the absorption and desorption of analytes for headspace liquid-phase microextraction (HS-LPME) were studied. It was found that the desorption of analytes from the extraction phase into the sample matrix is isotropic to the absorption of the analytes from the sample matrix into the extraction phase under the same conditions. This therefore allows for the calibration of absorption using desorption. Calibration was accomplished by exposing the extraction phase, which contained a standard, to the sample matrix. The information from the desorption of the standard, such as time constant a, could be directly used to estimate the concentration of the target analyte in the sample matrix. This new kinetic calibration method for headspace LPME was successfully used to correct the matrix effects in the BTEX analysis of an orange juice sample. In this study, the headspace LPME techniques were successfully fully automated, for both static and dynamic methods, with the CTC CombiPal autosampler. All operations of headspace LPME, including sample transfer and agitation, filling of extraction solvent, exposing the solvent in the headspace, withdrawing the solvent to syringe and introducing the extraction phase into injector, were autoperformed by the CTC autosampler. The fully automated headspace LPME technique is more convenient and improved the precision and sensitivity of the method. This automated dynamic headspace LPME technique can be also used to obtain the distribution coefficient between the sample matrix (aqueous or another solution) and the extraction phase (1-octanol or another solvent). The distribution coefficient between 1-octanol and orange juice, at 25 degrees C, was obtained with this technique.

Adsorption↗

Time-weighted average water sampling with a solid-phase microextraction device.

A fiber-in-needle SPME device was developed and investigated for time-weighted average water sampling. The device was designed so that the overall mass-transfer resistance is contained within the static water inside the needle, which ensures that mass uptake could be predicted with Fick's first law of diffusion and the sampling rate is less affected by water turbulence. The device possesses all of the advantages of commercialized devices, in addition to needle filling and replacement ease. Laboratory calibration with deployment of the device to a flow-through system demonstrated that there was a linear mass uptake for up to 12 days, and the linear range could be longer. PDMS coating is assumed to be a perfect zero sink for most polycyclic aromatic hydrocarbons, except naphthalene. The effect of water temperature was also investigated. Under normal field conditions, the change of mass uptake rate with temperature was negligible. To facilitate the convenience for long-term water sampling, a new standard aqueous generator was introduced. This study extended the application of SPME technology for long-term water sampling.

Journal Article↗

Flow-through system for the generation of standard aqueous solution of polycyclic aromatic hydrocarbons.

Standard aqueous solution of organic pollutants is used for the development of analysis methods and novel water sampling devices. The use of solid-phase microextraction (SPME) and other novel technologies for research in water sampling and analysis requires systems for the reliable generation of standard aqueous solution. In this communication, a new flow-through system based on permeation is introduced for the generation of standard aqueous solution of polycyclic aromatic hydrocarbons (PAHs). The main difference between the new developed system and typical system is that the syringe pump was changed with a permeation generator. The generator-based permeation offers many advantages, including convenient, inexpensive, solvent-free, long lifetime and production of high concentrations of the target analytes. The observed change in the concentration of the six PAH compounds was less than 20% over 3 months.

Dialysis↗

Calibration of solid-phase micro-extraction for quantitative analysis by gas chromatography.

Calibration of SPME by the injection of liquid standard solution is a common method for SPME quantitative analysis by gas chromatography. The feasibility of this calibration method relies on the assumption that sample transfer efficiencies are the same for both the liquid injection and the SPME fiber injection. Sample transfer efficiencies for liquid injection and SPME fiber injection were studied in this paper. The results showed that the sample transfer efficiency for liquid injection was affected by several factors, such as the dimensions of the liner, the presence of the wool, and the temperature of the injector. The sample transfer efficiency for SPME fiber injection was affected by the cross-sectional area of the space between the column and the liner, the carrier gas flow rate, and the length of the column inside the liner. An equation was proposed to estimate the sample loss rate for SPME injection. It was found that the use of a direct injection (DI) liner and program temperature vaporizing provides high sample transfer efficiencies, for both liquid injection and SPME fiber injection. When a common SPME straight liner is used, large outer diameter (o.d.) pre-column will help to achieve high sample transfer efficiency.

Acenaphthenes↗