Search PubMed⌕ Search

Biomedical subjects

G-A Hansson

Publications and source records attributed to G-A Hansson.

8 recordsLinked to original sources

Musculoskeletal disorders among female and male air traffic controllers performing identical and demanding computer work.

Operators with identical, demanding computer work (90 female and 97 male air traffic controllers) were found to have high prevalences of disorders (assessed by questionnaire and physical examination) in neck, shoulders and upper back. In spite of the identical work, the women displayed higher prevalences than the men (e.g. neck diagnoses 21% vs. 4%). Disorders in elbows, wrists and hands were less common, with similar rates in both genders. Generally, the psychosocial work environment (assessed by questionnaire) was found to be good, but with large inter-individual variation. Women experienced lower decision latitude than men, particularly regarding influence and freedom at work, but perceived higher social support. Physically, the work was characterized by relatively low angular velocities of upper arms (measured by inclinometry) and wrists (right: < 1 degrees/s during 19% of time, measuring by goniometry), dynamic muscular activities and high time fractions of rest in the trapezius and forearm extensor muscles (measuring by electromyography). There were only minor differences between the genders.

Accidents, Aviation↗

Precision of measurements of physical workload during standardised manual handling. Part II: Inclinometry of head, upper back, neck and upper arms.

For measuring the physical exposure/workload in studies of work-related musculoskeletal disorders, direct measurements are valuable. However, the between-days and between-subjects variability, as well as the precision of the method per se, are not well known. In a laboratory, six women performed three standardised assembly tasks, all of them repeated on three different days. Triaxial inclinometers were applied to the head, upper back and upper arms. Between-days (within subjects) and between-subjects (within tasks) variance components were derived for the 10th, 50th and 90th percentiles of the angular and the angular velocity distributions, and for the proportion of time spent in predefined angular sectors. For percentiles of the angular distributions, the average between-days variability was 3.4 degrees , and the between-subjects variability 4.0 degrees . For proportion of time spent in angular sectors, the variability depended on the percentage of time spent in the sector; the relative variability was scattered and large, on average 103% between days and 56% between subjects. For the angular velocity percentiles, the average between-days variability was 7.9%, and the average between-subjects variability was 22%. The contribution of the measurement procedure per se to the between-days variability, i.e., the imprecision of the method, was small: less than 2 degrees for angles and 3% for angular velocity.

Acceleration↗

Self-assessed and directly measured occupational physical activities--influence of musculoskeletal complaints, age and gender.

This study compares questionnaire assessed physical activity with direct technical measurements among cleaners and office workers, stratified regarding age, gender and self-reported neck/shoulder complaints. During two full working days number of steps was recorded by a pedometer, sitting/standing positions by a posimeter and heart rate by a Sport-Tester. In addition the subjects kept a work task diary for 10 days. There were high intra-individual variations in exposure between the days. Subjects with complaints rated their exposure higher than those without, although they in fact showed lower direct measured exposure. This may imply underestimation of exposure-effect relationships. Rate of perceived exertion showed low correlation with heart rate ratio within the two occupational groups, but high, 0.64 when the two groups were combined. Age and complaints explained 31% of the variance for the cleaners.

Adult↗

Measurements of wrist and forearm positions and movements: effect of, and compensation for, goniometer crosstalk.

Flexible biaxial goniometers are extensively used for measuring wrist positions and movements. However, they display an inherent crosstalk error. The aim was to evaluate the effect, of this error, on summary measures used for characterizing manual work. A goniometer and a torsiometer were combined into one device. An algorithm that effectively compensated for crosstalk was developed. Recordings from 25 women, performing five worktasks, were analyzed, both with and without compensation for crosstalk. The errors in the 10th, 50th and 90th percentiles of the flexion/extension distributions were small, on average <1 degrees. The ulnar/radial deviation distributions were weakly dependent on forearm position. The flexion/extension velocity measures were, for the 50th and 90th percentiles, as well as the mean velocity, consistently underestimated by, on average, 3.9%. For ulnar/radial deviation, the velocity errors were less consistent. Mean power frequency, which is a measure of repetitiveness, was insensitive (error <1%) to crosstalk. The forearm supination/pronation angular distributions were wider, and the velocities higher, than for the wrists. Considering wrist/hand exposure in epidemiologic studies, as well as for establishing and surveillance of exposure limits for prevention of work-related upper extremity musculoskeletal disorders, the crosstalk error can, when considering other errors and sources to variation, be disregarded.

Algorithms↗

Precision of measurements of physical workload during standardised manual handling. Part I: surface electromyography of m. trapezius, m. infraspinatus and the forearm extensors.

Though surface electromyography (EMG) has been widely used in studies of occupational exposure, its precision in terms of the variance between-days and between-subjects has seldom been evaluated. This study aimed at such an evaluation. Six women performed three different work tasks: 'materials picking', 'light assembly', and 'heavy assembly', repeated on 3 different days. EMG was recorded from m. trapezius, m. infraspinatus and the forearm extensors. Normalisation was made to a maximal (MVE), and a submaximal (RVE), reference contraction. Variance components between days (within subjects) and between subjects were derived for the 10th, 50th and 90th percentiles, as well as for muscular rest parameters. For the task 'heavy assembly', the coefficient of variation between days (CV(BD)) was 8% for m. trapezius (right side, 50th percentile, MVE normalised values). Larger variabilities were found for m. infraspinatus (CV(BD) 15%), and the forearm extensors (CV(BD) 33%). Between-subjects variability (CV(BS)) was greater, 16% for m. trapezius and 57% for m. infraspinatus, 29% for the forearm extensors. RVE normalisation resulted in larger CV(BD), while reducing CV(BS). The between-days and between-subjects variability may be used to optimise sampling strategy, and to assess the bias in epidemiological studies. The bias caused by measurement procedures per se is acceptable.

Adult↗

The impact of working technique on physical loads - an exposure profile among newspaper editors.

The aim of this study was to investigate the possible associations between working technique, sex, symptoms and level of physical load in VDU-work. A study group of 32 employees in the editing department of a daily newspaper answered a questionnaire, about physical working conditions and symptoms from the neck and the upper extremities. Muscular load, wrist positions and computer mouse forces were measured. Working technique was assessed from an observation protocol for computer work. In addition ratings of perceived exertion and overall comfort were collected. The results showed that subjects classified as having a good working technique worked with less muscular load in the forearm (extensor carpi ulnaris p=0.03) and in the trapezius muscle on the mouse operating side (p=0.02) compared to subjects classified as having a poor working technique. Moreover there were no differences in gap frequency (number of episodes when muscle activity is below 2.5% of a reference contraction) or muscular rest (total duration of gaps) between the two working technique groups. Women in this study used more force (mean force p=0.006, peak force p=0.02) expressed as % MVC than the men when operating the computer mouse. No major differences were shown in muscular load, wrist postures, perceived exertion or perceived comfort between men and women or between cases and symptom free subjects. In conclusion a good working technique was associated with reduced muscular load in the forearm muscles and in the trapezius muscle on the mouse operating side. Moreover women used more force (mean force and peak force) than men when operating the click button (left button) of the computer mouse.

Adult↗

Influence of the subcutaneous fat layer, as measured by ultrasound, skinfold calipers and BMI, on the EMG amplitude.

Surface electromyography (sEMG) is an important tool to estimate muscular activity at work. There is, however, a great inter-individual variation, even in carefully standardized work tasks. The sEMG signal is attenuated in the subcutaneous tissues, differently for each subject, which requires normalization. This is commonly made in relation to a reference contraction, which by itself, however, introduces a variance. A normalization method that is independent of individual motivation, motor control and pain inhibition would be desirable. The aim of the study was to explore the influence of the subcutaneous tissue thickness on sEMG amplitude. Ultrasound measurements of the muscle to skin surface distance were made bilaterally over the trapezius muscle in 12 females. Skinfold caliper measurements from these sites, as well as from four other sites, were made, body mass index (BMI) was recorded, and sEMG was recorded at maximal and submaximal contractions. The muscle-electrode distance, as measured by ultrasound, explained 33% and 31% (on the dominant and non-dominant sides respectively) of the variance of the sEMG activity at a standardized submaximal contraction (average between the sides, 46%); for maximal contractions the explained variance was 21%. Trapezius skinfold measurements showed poor correlations with sEMG. Instead, the mean of skinfold measurements from other sites explained as much as 68% (submaximal contraction). The corresponding figure for BMI was 67%. In conclusion, skinfold thickness explains a major part of the inter-individual variance in sEMG amplitude, and normalization to this measure is a possibility worth further evaluation.

Adipose Tissue↗

Modular data logger system for physical workload measurements.

Direct technical measurements of physical workload have advantages in studies of work-related musculoskeletal disorders. A data logger has been developed, based on 20 and 40 Mbyte PCMCIA (Personal Computer Memory Card International Association) flash memory cards, for electromyography (EMG), inclinometry and goniometry. They are provided with an input for marking of events that can be used for synchronization with other loggers and with video recordings. To make the data easier to access by the preceeding analysis software, application software has also been developed that reorganizes the data. The loggers are easy to operate and enable whole-day ambulatory field recordings without any need for reduction or compression of the data.

Electronic Data Processing↗