Search PubMed⌕ Search

Biomedical subjects

Günter Weiler

Publications and source records attributed to Günter Weiler.

5 recordsLinked to original sources

Simultaneous screening and detection of drugs in small blood samples and bloodstains.

A gas chromatography-mass spectrometry (GC-MS) method is described for the screening and detection of morphine, codeine, cocaine, benzoylecgonine, methylecgonine, cocaethylene, delta-9-tetrahydrocannabinol (THC), 11-nor-9-carboxy-THC (THC-COOH), 11-hydroxy-THC (11-OH-THC), amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymetamphetamine (MDMA) and N-methyl-1-(3,4-methylenedioxyphenyl)-2-butanamine (MBDB) in small blood samples and bloodstains using solid phase SPE columns and a pipetting robot (Gilson Aspec XL). The detection limits are in the order of 1.62-4.10 ng/50 microl spot (amphetamines), 0.15-0.82 ng/50 microl spot (cannabinoids), 1.67-4.70 ng/50 microl spot (cocaine and derivatives) and 4.53-4.91 ng/50 microl spot (opiates) and the correlation factors are between 0.9957 and 0.9999. The method has proven useful in forensic cases with only small sample volumes or bloodstains.

Adult↗

Studies of interferences of apomorphine and its metabolites or decomposition products with immunochemical screening tests for legal and illicit drugs after therapeutic doses of apomorphine.

This study deals with the question of whether apomorphine (CAS 314-19-2; e.g. in Ixense) and its metabolites or decomposition products interfere with the specificity of immunochemical screening tests (immunoassays) for legal and illicit drugs. It was the result of the investigations that after the therapeutic use of apomorphine no relevant false-positive screening findings were observed with the CEDIA (cloned enzyme donor immuno assay) and FPIA (fluorescence polarisation immuno assay) tests, which are commonly encountered in drug-screening programs, when using recommended cut-off values for urine.

Apomorphine↗

[Cadaver mix-up--an avoidable problem?].

Depending on local conditions it may happen from time to time that no officer involved in the previous investigation is present during the forensic autopsy. In this case, the post mortem examiner often has to rely solely on written documentation concerning the identity of the deceased. The authors report a case where the body had already been mixed up with another body by the undertaker prior to the inspection by the police. In spite of clear distinguishing characteristics in the written documentation, this led to the wrong body being autopsied. For the post mortem examiner, the only safe way to identify a body seems to be the presence of persons who had known the deceased or of police officers as acknowledging witnesses. If these conditions are not given, other means of safe information on the identity are called for, for example a "police body card" similar to an evidence card.

Adult↗

[Screening and detection of amphetamine derivatives in biological stains].

A GC/MS-method is described for the screening, detection and determination of the commonly used drugs amphetamine, methamphetamine, MDA, MDMA and MBDB in small blood samples and bloodstains using solid phase SPE columns and a pipetting robot (Gilson Aspec XL). The detection limits are in the order of 0.03 to 0.08 microgram/L and the correlation factors between 0.9982 and 0.9998. Furthermore the stability was investigated covering a storage time of 64 days. The method has proven useful in forensic cases with only small sample volumes or bloodstains.

3,4-Methylenedioxyamphetamine↗

[Heteroplasmy in mtDNA in a set of dizygotic twins].

The authors report on a case of a dicygotic female twin pair, one of them containing a T/C heteroplasmy in two (heart and brain) of five analysed organs at position nt204 of the HV2 region. Results and especially the evidence of an unequal distribution of the heteroplasmy are discussed.

Adolescent↗